OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

Similar documents
TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Hazardous Materials Management. Presented by. James E. Roughton, MS, CSP, CRSP, CHMM.

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

INDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Instructions for Completing the UW-Madison Laboratory Chemical Hygiene Plan Template

STANDARD OPERATING PROCEDURES (SOP) FOR REPRODUCTIVE HAZARDS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Hazard Communication Program

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

PURPOSE OF THE POLICY

Laboratory Standard Operating Procedure: Carcinogens

HAZARDOUS INCIDENT SITE SAFETY PLAN

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

HAZARDOUS WASTE OPERATIONS AND EMERGENCY RESPONSE

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities.

POTENTIAL HEALTH & SAFETY HAZARDS

Compressed Gases and Cryogens

Northern Kentucky University Issue Date: 11/02/2018 Revised Date: Title: PERSONAL PROTECTIVE EQUIPMENT PROCEDURE OBJECTIVE AND PURPOSE

CONTRACTOR WHS HAZARD STANDARD HAZARDOUS CHEMICALS EXTERNAL USE ONLY

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

Laboratory Standard Operating Procedure: Reproductive Toxins

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures

Western Sydney University Safety Inspection Checklist - Laboratory Environments

LABORATORY ANIMAL ALLERGEN PREVENTION PROGRAM

Key Technology, Inc. Confined Space Entry Program. July, 2017

Research Laboratory Safety Self-Inspection: Chemical & Physical Safety Checklists

Laboratory Inspection Checklist

EMA, Inc. SITE SAFETY PLAN

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

LABORATORY FUME HOOD SPECIFICATION AND MAINTENANCE PROGRAM

Northeast Biomanufacturing Center and Collaborative. Hazard Communication Program (HCP) NBC-HCP-000

Effective Date: 24-April-2017 Version: 6 Page: 1 of 8 TITLE: SAF-370, PERSONAL PROTECTIVE EQUIPMENT GUIDELINES. Table of Contents

Safety Manual Section 6 Confined Space

A. Evaluation of the written program

1.2.7 Hazard Communication

Hazardous Materials Management Guidelines

Selection, Care and Use of Chemical Protective Clothing. Jason Cole Director of R&D Kappler, Inc.

TOWN OF LINCOLN ARENA FACILITIES OPERATIONAL SAFETY POLICY

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

Safe Work Practices / Procedures / Instruction CONFINED SPACE

TABLE OF CONTENTS PART 2 - CONFINED SPACES

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist

Title: Hexavalent Chromium Compliance. Preparer: Owner: Approver: Texas EHS EHS Team Member

HAZARD COMMUNICATION SELF INSPECTION CHECKLIST

Health, Safety, Security and Environment

OFFICE OF STATE HUMAN RESOURCES

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre

Lockout/Tagout Safety Policy

Equipment Decommissioning and Removal

B&B Gas Well Services, LLC HEALTH, SAFETY AND ENVRONMENTAL MANUAL HAZARD COMMUNICATION PROGRAM

1 Purpose. 2 Responsibilities. 3 Policy Content ENVIRONMENTAL, HEALTH AND SAFETY STANDARDS. TITLE: CONFINED SPACE ENTRY Document Number: *

Laboratory Self Inspection Checklist LAB01

Vision Painting Inc Safety Management System

Recommended Facilitator Notes: (read the following text out-loud to participants while showing this slide)

The primary purpose of laboratory fume hoods is to keep toxic or irritating vapors out of the general laboratory working area.

SECTION LEAD-PAINT REMOVAL

Laboratory Standard Operating Procedure: Cryogenic Liquids

Laboratory Standard Operating Procedure: Sensitizers

Compressed Gas Cylinders - Guideline

Environmental Health & Safety Policy Manual

SAFETY DATA SHEET PRODUCT NAME Sulfur hexafluoride 1.2 RELEVANT IDENTIFIED USES OF THE SUBSTANCE OR MIXTURE AND USES ADVISED AGAINST :

CONFINED SPACE PROGRAM

1.0 Scope and Application. 2.0 Definitions. Cal Poly Risk Management Confined Space Program Page 1

! Subpart D - Contingency Plans and Emergency Procedures (40 CFR to ) (EPA regulations adopted by NJDEP); and

Hazard Communication Program

MANAGEMENT PROCEDURE FOR LABORATORY VENTILATION

HAZARD COMMUNICATION PROGRAM

PERSONAL PROTECTIVE EQUIPMENT FOR CHEMICAL EXPOSURES

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

Chapter 4: Implementing Effective Exposure Controls

University of Vermont Department of Physical Plant Personal Protective Equipment Program

PERSONAL PROTECTIVE EQUIPMENT

GUIDELINES FOR SLUG DISCHARGE MANAGEMENT PLAN (Abstract from EPA Guidance Manual)

SAFETY POLICY AND PROCEDURE MANUAL QUESTIONNAIRE

BODY OF KNOWLEDGE API TES TANK ENTRY SUPERVISOR

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

Confined Space Program

Health & Safety Policy and Procedures Manual SECTION 34 HYDROGEN SULFIDE (H2S) PROGRAM

Personal Protective Equipment

STANDARD OPERATING PROCEDURE (SOP): URETHANE

SECTION 7 HAZARD COMMUNICATION PROGRAM

Personal Protective Equipment

CONFINED SPACE PROGRAM

Asbestos Operations and Maintenance Plan

Carnegie Mellon University. Toxic and Highly Toxic Gas Handling Program

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300

WEBINARS. Hazard Communication

Environmental Health & Safety Policy & Procedure #35

HEALTH AND SAFETY MANUAL

Isoflurane: Safe Use Guidelines. (2-chloro-2-(difluoromethoxy)-1,1,1- trifluoro-ethane) is a halogenated ether used for inhalational anesthesia.

ANSI Z Compliance Checklist

BIOSAFETY SELF AUDIT PRINCIPAL INVESTIGATOR/PERMIT HOLDER: CONTAINMENT LEVEL: 1 2 (Shaded) RISK GROUP: 1 2 AUDIT TO BE COMPLETED BY (DATE):

NUS Safety & Health Guidelines Procedure No: OSHE/SOP/GL/08

Emergency Response Code CODE BROWN HAZARDOUS SPILLS. Purpose & Authority. Definitions

LABORATORY SAFETY. A general overview

Hydrogen Cyanide (HCN)

HAZARD COMMUNICATION & THE GLOBAL HARMONIZING SYSTEM EMPLOYEE TRAINING. Leader s Guide. ERI Safety Videos

CONFINED SPACE WRITTEN PROGRAM

Transcription:

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE Subject: Installation, Use and Maintenance of Gas Source Semiconductor Tools Date: 5/28/03 Revision: 00 SUMMARY: Individuals working with gas source semiconductor tools must be aware of potential hazards associated with them, and must be trained and proficient in methods to work with the tools and associated apparatus in a safe manner. Each lab must conduct a risk assessment identifying potential hazards and the precautions necessary to protect individuals from hazards. This is essential to safeguard both the individuals as well as surrounding facility areas. A release of the gas can easily impact on the entire facility as it is carried through the ventilation system. SCOPE: This Guideline applies to all UM researchers and employees who own or operate equipment used to manufacture, measure, assemble and test semiconductor products using a hazardous production material (HPM) gas source. OSEH management may grant exemptions to small-scale operations or low concentrations of HPM gas. Contact OSEH for an evaluation. REFERENCE REGULATIONS: Control of Hazardous Energy (Lockout/Tagout) (MIOSHA Part 85) Hazard Communication (MIOSHA Part 430) Inorganic Arsenic (MIOSHA Part 308) Hazardous Work in Laboratories (MIOSHA Part 431) Personal Protective Equipment (MIOSHA Part 433) International Building Code International Fire Code NFPA 45 Standard on Fire Protection for Laboratories Using Chemicals NFPA 50A Standard for Gaseous Hydrogen Systems at Consumer Sites Factory Mutual 7-7, 17-12 (Semiconductor Fabrication Facilities) Extremely Hazardous Substances List and Threshold Planning (EPA 40 CFR Part 355) DEFINITIONS: Buddy system an administrative control requiring the presence of two trained persons when work of a potentially hazardous nature is being performed. All gas systems work is considered potentially hazardous. Continuous gas monitoring system (GMS) uninterrupted monitoring, occurring in real-time, with associated alarms. Decontamination the removal of materials in or on equipment, people, or personal protective equipment.

EMO emergency off button. Exhaust treatment devices systems designed to remove specific toxic particles and gases from an exhaust stream. These include but are not limited to scrubbers, charcoal traps and burn boxes. Flammable gas a gas is considered flammable when either a mixture of 13 percent or less (by volume) with air forms a flammable mixture, or the flammable range with air is wider than 12 percent regardless of the lower limit. The limits shall be determined at atmospheric temperature and pressure. Gas cabinet cabinet used to house and contain gas cylinders, and connected to gas distribution piping or to equipment using the gas. Gas delivery system the system made up of a gas source, gas panel, piping and all associated valves and safeguards. Gas panel an arrangement of gas handling components (e.g., valves, filters, mass flow controllers) that regulates the flow of gas into the process. Gas panel enclosure an enclosure designed to contain leaks from gas panel(s) within itself. Hazardous Production Material (HPM) a solid, liquid, or gas that has a degree of hazard rating in health, flammability, or reactivity of class 3 or 4 as ranked by NFPA 704 and which is used directly in research, laboratory, or production processes that have as their end product materials that are not hazardous. High Efficiency Particulate Air (HEPA) refers to an air filter that must be 99.97% efficient (i.e. a maximum of three particles of 0.3 micron aerodynamic diameter can pass for every ten thousand particles fed to the filter). Just in time delivery (JIT) refers to the practice of having gases delivered as they are needed rather than storing gases on site. Local exhaust ventilation (LEV) a ventilation system that captures air contaminants at their point of origin and moves the air to the external environment. Personal protective equipment (PPE) devices worn by workers to protect against hazards in the environment. Examples include gloves, safety glasses, face shields, respirators, hard hats, steel-toed shoes and hearing protection.

Pyrophoric material a chemical that will spontaneously ignite in air at or below a temperature of 54.4 C (130 F). Restrictive flow orifice a flow-limiting device inserted in the cylinder valve by the gas vendor to control excess flow in an unrestricted gas release. Standard operating procedure (SOP) the technical requirements necessary to complete laboratory procedures and actions safely. Once developed, SOPs are documented and implemented in the workplace and used for training purposes. Threshold Limit Value (TLV ) - TLVs refer to airborne concentrations of substances and represent conditions under which it is believed that nearly all workers may be repeatedly exposed day after day without adverse health effects. TLV-TWA Threshold limit value as an 8-hour time-weighted average. RESPONSIBILITY:Deans, Directors, and Department Heads Ensure compliance with this Guideline by supporting the proper design, purchase, and installation of equipment, ongoing maintenance, and training of staff. Principal Investigators Ensure that a comprehensive plan for the design, installation and maintenance of the tool, gas delivery and GMS systems is drawn up prior to bringing the tool on site. Assume the responsibility for installation, operation, maintenance and training for the tool (including vacuum pumps, chillers and other support equipment), gas delivery and GMS systems, and for any specialized exhaust treatment systems. Identify proper storage locations for gas bottles unless using a just in time delivery system. Develop a risk assessment to clearly define the source and nature of all potential hazards and people who may be affected by them. This assessment must be performed and significant findings recorded by a person or persons who are adequately trained and competent to perform such duties by virtue of their professional qualifications and experience with semiconductor tools and processes. Develop SOPs for routine tasks, maintenance and decontamination procedures on each gas source tool, gas delivery and GMS systems, and for any specialized exhaust treatment systems. This includes incorporating

emergency response procedures to address the potential for fire and release or generation of toxic gases. Ensure that their research staff are trained on the SOPs and able to safely operate each gas source tool owned or operated by the lab. Ensure written records of training are maintained for review by OSEH or other investigators following an adverse event. Ensure that all engineering controls are in place and operational prior to commencing research operations involving use of the tool (OSEH prior approval contingency). Maintain as built drawings of the tool and associated gas delivery, GMS and exhaust treatment equipment installation for future reference and updating as modifications occur. Research Staff Be knowledgeable and familiar with each gas source tool used in the lab. Perform only those functions for which they have been trained. Be able to implement emergency response procedures associated with the use of the gas source tool. Properly use all safety equipment and follow safety procedures. OSEH Review and revise this Guideline as necessary. Assist in reviewing the design and installation of the tool and in the development and review of SOPs. Advise Principal Investigator in matters of safety including precautions to be taken when handling chemicals associated with use of the gas source tool, requirements for safety equipment and monitoring. Provide inspections and exposure monitoring as needed. This includes initial start up and periodically thereafter as dictated by findings and available industrial hygiene evaluations of the equipment or processes. PROCEDURES: I. Design & Installation OSEH requires all gas source tools brought into a University of Michigan laboratory be in conformance with the guidelines specified in SEMI S2-0200, Environmental, Health and Safety Guideline for Semiconductor Manufacturing Equipment. This guideline requires the supplier to provide all evaluation reports pertaining to the operation, maintenance, safety systems and any industrial hygiene, fire protection, and environmental

information. It also requires the supplier to provide equipment manuals and any other useful information to enable safe operation, maintenance and service of the equipment. This information will be invaluable to the University in the design, installation, operation, safety and development of SOPs. If the tool has been developed in a research environment, the laboratory should attempt to gain as much information as possible pertaining to the construction of the tool. Contact the appropriate University departments (departmental facilities management, Plant Extension, OSEH, DPS Fire Marshal, Risk Management) early in the planning and design phase to ensure tie in to building utilities and other construction and installation aspects are carried out in accordance with University standards. At a minimum, design of safety systems and tool installation must comply with the International Building Code (IBC) and International Fire Code (IFC), which have been adopted by the University. For additional guidance on safety systems, the Semiconductor Equipment and Materials International standards should be consulted, as well as Factory Mutual 7-7, 17-12, Semiconductor Fabrication Facilities. II. Safety Systems All researchers with gas source semiconductor tools must address the following safety features during design and installation: A. Quantity of HPM HPM in use or in storage must not exceed the quantities listed in IBC and IFC. Quantities must also stay below 10% of the Threshold Planning Quantities as listed by the Environmental Protection Agency, 40 CFR Part 355. Quantities must be kept to the minimum necessary for normal operation of the lab. This will usually mean one cylinder of an appropriate size in use to allow for change out of the cylinder once or twice per year (change out is a high risk task, requiring use of the buddy system). Just in time (JIT) delivery is preferred over storage of a back up cylinder on site. B. Containment and delivery of HPM gas All HPM gases must be delivered through continuous, orbitally welded, coaxial tubing that is of a material compatible with the gas. Only employees who are specifically trained and qualified to perform orbital welding on coaxial tubing may do so. Hydrogen, methane and fluorine, though HPM gases, can be delivered in single wall stainless steel tubing provided all mechanical connections are inside exhausted enclosures equipped with GMS. No mechanical connections exposed to the process gas stream are to be outside of exhausted enclosures equipped with GMS.

All HPM gases in use and in storage must be kept in locally exhausted gas cabinets or in suitable gas storage bunkers. Each of the storage locations must also have provisions for actively monitoring the ambient environment and exhaust to detect for the gases stored. This provision must provide for both local and remote annunciation in the event there is a gas leak. This annunciation may also be required to be tied into a building type alarm (facility dependent). Restrictive flow orifices, where appropriate, must be used to preclude massive releases in the event of a catastrophic release. Follow all requirements of the IBC and IFC pertaining to gas delivery systems. C. Continuous gas monitoring system (GMS) Tools utilizing HPM gases must be equipped with continuous GMS applicable to the material in use with remote readout capability. The GMS must be designed according to IBC and IFC. D. Fire Detection & Suppression The fire detection system that includes detectors, alarms and their associated controls should be installed and certified in accordance with all applicable fire and University standards. The system should be capable of interfacing with the facility s alarm system and the University s MOSCAD system at the Department of Public Safety. All aspects of the fire detection and suppression system must meet the requirements of the IFC. E. Ventilation Local exhaust ventilation must be available in the lab to capture and remove contaminants at the source. This includes but is not limited to gas cabinets for cylinders, gas panel enclosures and snorkel exhaust for chamber openings and pump exhaust, and exhaust treatment devices for pyrophoric and corrosive gases. Ventilation systems must meet all University standards and the IBC, IFC and the International Mechanical Code and must be reviewed by departmental facilities management and the University Plant Extension. A dedicated HEPA vacuum must be available for use in the lab. Nilfisk is one manufacturer that offers a vacuum with a combination of HEPA and charcoal filters. The exhaust system for removal of any HPM must be a dedicated system. Prior to installation, contact OSEH Environmental Management Program for review of all effluent waste treatment

systems and other environmental compliance issues. F. Emergency Safeguards and Procedures The tool, gas delivery system, and other high hazard processes that could potentially produce an uncontrolled emergency release of HPM must be capable of automatic and remotely activated emergency shutdown, as per IBC and IFC. The EMO actuator should be readily accessible along the emergency egress path from the room or facility, and its activation should place the equipment in a safe mode. Activation of the EMO should not affect fire, gas monitoring or safety systems. See IBC and IFC for further details. All safety systems including ventilation, GMS, fire protection, EMOs, and suppression must have emergency back up power capable of supporting the system for 24 hours or be integrated into an Uninterrupted Power Supply system. The EMO system, GMS and fire detection should be tied into the facilities emergency notification system. A written Emergency Response Plan specific to the lab must be developed. The Plan must be integrated with the University of Michigan s Contingency Plans and coordinate with other University emergency response units such as DPS and OSEH as well as outside response agencies where appropriate. The department or PI will coordinate with OSEH and DPS in ensuring that adequate staff for emergencies are trained, equipped and available to assist in emergency response operations in the lab. OSEH will assist in the development, review and maintenance of this plan. III. Standard Operating Procedures All researchers with gas source tools must develop and implement standard operating procedures (SOPs) for normal operation and maintenance procedures. This includes incorporation of emergency procedures to address personal exposure as well as the potential for fire and release or generation of toxic gases. The SOPs need to be reviewed and/or updated at least annually. SOPs must include the following information on routine tasks, as well as appropriate maintenance and decontamination methods to enable safe operation and maintenance of the tool and gas delivery, containment and detection systems, and any specialized exhaust treatment systems: 1. A list of all personnel authorized to perform gas bottle changes, and a description of the access requirements to the gas storage/delivery area. 2. A description of any safety measures provided in and associated with the tool (i.e., safety interlocks, restrictive flow orifices on gas bottles, emergency off (EMO) circuits, local exhaust ventilation, HEPA

vacuum for particulate capture). 3. An explanation of any hazard alerts including but not limited to visual alerts, auditory alarms, status indicators, and hazard alert systems integral with the equipment s operating system. 4. A summary of hazards inherent in the tool and associated equipment, including their location and any safety controls and recommendations to prevent injury from the hazards. This summary must include protocols to address equipment failure in the event of power interruption. 5. Specific instructions for routine operation of the tool and gas delivery, containment and GMS systems. 6. Hazardous energy control procedures for any source of electrical, chemical, thermal or mechanical energy, radiation and compressed air or liquid energy that exists in the tool. Refer to the OSEH Guideline on Lockout/Tagout (http://www.oseh.umich.edu/pdf/guideline/ loto_guideline.pdf). 7. A listing of all chemical substances that will be used in and with the tool. Attaching the Material Safety Data Sheets for each chemical to the SOP is ideal. However, in the event that numerous chemicals will be used, a reference to where the MSDS(s) are maintained in the lab is acceptable. 8. The hazards associated with each chemical, the personal protective equipment required to prevent exposure, and emergency procedures to follow in the event of exposure or release of a chemical. When listing necessary PPE, be as specific as possible (i.e., butyl rubber gloves as opposed to gloves ). A risk assessment matrix to assist in the evaluation of hazards is provided in Appendix A. 9. Waste handling procedures as applicable. 10. Procedures for ordering, receiving, inspecting, transporting, storing and changing the gas bottles. Procedures for when and how DPS will be notified. A description of when and how leak check procedures will be performed must also be included. A gas cylinder change checklist and use of the buddy system for cylinder change outs are highly recommended. Laboratories should arrange for JIT delivery of gases to minimize the quantities stored on site. 11. Emergency and decontamination procedures in the event of toxic or flammable/pyrophoric gas release, fire, or personal exposure. 12. A description of the training and qualification requirements for each person who will use or work on the tool and gas delivery and GMS systems.

13. Maintenance and calibration procedures for GMS equipment. 14. Maintenance procedures for any specialized exhaust treatment systems. IV. Routine Tasks, Maintenance and Decontamination procedures 1. If applicable, ensure the lockout/tagout procedure has been followed. 2. Prior to beginning work, ensure that all necessary PPE is available, and then used as necessary during the work. 3. Pumping and purging of gas lines may not always remove all toxic material. Use local exhaust ventilation (LEV) to capture and remove any airborne particulate or gas released upon opening the chamber ports and vacuum pumps (when applicable). LEV must remain in operation during maintenance and decontamination procedures unless alternate exhaust provisions have been arranged. If it is not possible to use LEV, respiratory protection must be used. 4. While disconnecting equipment or removing components, gas monitoring at the source for toxic gases must be performed. 5. If the chamber is to be vacuumed, a dedicated vacuum with HEPA filter must be used. All users must be knowledgeable in the maintenance requirements of the vacuum and procedures for changing and disposing the filter. 6. Any surface potentially contaminated with toxic solids must be thoroughly wiped down with water. Specify how this waste will be collected for eventual disposal by OSEH Hazardous Materials. V. Training Training will include: 1. Information on the physical and chemical hazards associated with use and maintenance of the tool. 2. A review of all established SOPs pertaining to use and maintenance of the tool and gas delivery, containment and GMS systems and any specialized exhaust treatment systems. 3. Access requirements for those personnel authorized to change the gas bottles. 4. A review of emergency procedures.

RELATED DOCUMENTS: SEMI SEMI S10-1296 Safety Guideline for Risk Assessment S12-0298 Guidelines for Equipment Decontamination SEMI S2-200 Environmental, Health & Safety Guideline for Semiconductor Manufacturing Equipment Hazard Communication Program Personal Protective Equipment, General Lock-out/Tag-out Control of Hazardous Energy Sources TECHNICAL SUPPORT: All referenced guidelines and regulations are available through OSEH (7-1142). APPENDICES: Appendix A Risk Assessment Matrix