Roofing Adhesive PRODUCT DESCRIPTION PRODUCT DATA. Spray Applied Insulation Adhesive for Sarnafil Roofing Systems

Similar documents
Roofing Primer. Primer 610 Spray PRODUCT DESCRIPTION PRODUCT DATA. Spray Applied Primer for use with S-Vap 7000 E DP & Decostik SP

Cylinder Spray Adhesive - User s Guide

1. CONDITIONS FOR USE 2. SAFETY

Facade External Wall Insulation Accessories. Sto-Turbofix Application Guide

PRESSURISED PAINT CONTAINER

NS Cylinder Spray Adhesive - User s Guide

3M Scotch-Weld Specialty Cylinder Spray Adhesives

Solids Content of Adhesive propellant removed (by wt.): Solids Content aerosol (by wt.): 27.4% Volatile Organic Compounds (VOC):

Material Safety Data Sheet

Scotch-Weld Super 77 Cylinder Spray Adhesives

air/hydraulic nut riveter heavy-duty vacuum system

Hodge Clemco Ltd. SG-300 Suction Gun. Owner s Manual. Hodge Clemco Ltd

MANUAL. Sesame. Thermoplastic Tank Technologies

Technical Data Sheet PART A & PART B

Cylinder Adhesive for Geotextile Seaming

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Installation and commissioning instructions 255 series and 256 series

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Technical Data Sheet Effective: 04/05/2017 Supersedes: 01/01/2000

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

TEMPERATURE GRADIENT PLATE MFFT 10 / MFFT 20 VF9700 / VF9600

FLANGED TWO-PIECE BALL VALVES

OPERATING INSTRUCTIONS

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

INSTRUCTION MANUAL FOR POLYKEG DISPOSABLE KEG

Two-stage valve type NE

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

PREPARATION & APPLICATION OF S1125 ADHESIVES

EVOSTONE Solid Surface - Material Safety Data Sheet (MSDS) EVOSTONE PROPERTIES

Compact Ball Valves ASAHI AV VALVES. Contents. User s Manual. (Page) (1) Be sure to read the following warranty clauses of our product 1

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

1. Identification of the substance/preparation and of the company/undertaking

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Assembly and Installation Procedures

Wet Lamination of Dry Film Photoresist for the Hobbyist

Flexi-pro Aerosol Delivery System (FADS) Manual

abc INSTALLATION, OPERATING & MAINTENANCE MANUAL FOR HYDRAULIC EXTRACTOR

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

118 - Quick-Start Processing

Declaration of Conformity as per Directive 97/23/EC

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

ICYNENE INSTALLATION INSTRUCTIONS

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A

BS ml Bottle Sampling Unit

Pressure relief valve

TWO POST RAM PACKAGE 55 GALLON

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

INSTRUCTION MANUAL. Slavia 630/631

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Installation & Operation Manual Proven Quality since 1892

Pressure Relief Valve DHV 718

OPERATION MANUAL NTF-60 Plus

METHOD STATEMENT SikaFuko VT System

ALTERNATIVE INSTALLATION PROCEDURES FOR 90 AND 45 KTKK MOULDED PART AND ADAPTOR ASSEMBLIES

Introduction to Ecoseal

Product instruction manual Easymount Sign Laminators EM-S1400C, EM-S1600C, EM-S1400H, EM-S1600H

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

EC SAFETY DATA SHEET Trade Name : BOMBAY AL Status : 05/01/2011 Product Code : BW5020 Page : 1

3/8" KEYLESS REVERSIBLE AIR DRILL CT1086

FLANGED TWO-PIECE BALL VALVES

Pipettor. User Manual

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Siphon vessel / Priming aid

Operating Manual. 3S-R AirElite Full Face Mask Advantage AirElite Full Face Mask Advantage 4000 AirElite Full Face Mask. AirElite - Full Face Masks

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

RayPette Plus Autoclavable Pipette. User Manual

Pressure relief valve

ambiente Installation Guide AmbiScreedboard system more than underfloor Customer: Project: Project Reference: Date:

Damage Control/Luminous Shipboard Markings

ST 18 Aluminium Gas Model

GAS BBQ 4 burner. instructions for. model no: BBQ10

Yoke Block Instruction Manual

ASSEMBLY INSTRUCTIONS S-Dome system

ST 18 Aluminium Gas Model

APPLICATION GUIDE ECOSPEED FOR ALUMINIUM SURFACES

Advanced Fluid Handling Cart Owner s Manual

Patients Guide for Self Administering Intravenous Antibiotics General points

Parallel Reactor Standard Operating Procedure THIS SOP IS NOT MEANT TO REPLACE HANDS-ON TRAINING FROM QUALIFIED PERSONNEL!

two component solvent free amine cured phenolic epoxy coating (1 g/cm³ = 8.25 lb/us gal; 1 m²/l = 40.7 ft²/us gal) (data for mixed product)

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

Adjustment of SF6 pressure

Endura AZ40 Sensor assembly High temperature filter assembly kit

Type BBS-03, BBS-05, BBS-06, BBS-25

MODEL 1329 Tank Gauge

Presence PR, PRC & PRE

GENO -Flushing Compressor Product Data Sheet F 02

Operation Manual. PEGAS NovoTap, PEGAS NovoTap+

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

The pipettes cover a volume range from 0.1µl to 10ml.

Solvent System Walkthrough

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

Transcription:

Roofing Adhesive Spray Applied Insulation Adhesive for Sarnafil Roofing Systems PRODUCT DESCRIPTION TESTS PRODUCT DATA FORM Moisture curing PU based spray insulation adhesive in a pressurized canister system. USES Sika C 250 is a sprayable adhesive to bond suitable thermal insulation boards to specific substrates. CHARACTERISTICS / ADVANTAGES Quick and professional adhesive application Adheres to solid, rough and clean surfaces SUITABLE INSULATIONS SarnaTherm G/PIR insulation boards with lamination (glass or mineral fibre fleece) Mineral fibre boards with sufficient compressive strength and appropriate surface bonding SUITABLE SUBSTRATES Sarnavap 5000E SA vapour control layer Mineral or sand surfaced/aged bitumen Sika Primer 610 may be required on certain substrates APPROVAL / STANDARDS Quality management system EN ISO 9001/14001 CONSISTENCY / COLOUR Foaming liquid Colour Green PACKAGING One way canister: 24.5 kg (Adhesive 18.4 kg) Packaging unit: Single canister Packaging dimension: Cardboard box 320 mm x 320 mm x 460 mm Sep 2017, V1 1/5

STORAGE STORAGE CONDITIONS Store in dry conditions at temperatures between +5 C to +25 C SHELF LIFE 12 months from date of production if stored properly in original, unopened and undamaged sealed container. Expiry date on container. The adhesive will have a limited life once the container is opened. TECHNICAL DATA CHEMICAL BASIS Moisture curing PU based adhesive. APPLICATION FIGURES Open time (20 C) 1 4 minutes Curing time (20 C) 15 minutes SYSTEM INFORMATION APPLICATION DETAILS CONSUMPTION Consumption depends on the roughness and absorbency of the substrate and ranges approximately from 130 g/m 2 260 g/m 2. Beads width approx. 30 mm with a distance of 250mm in the central zone and 30 mm with a distance of 166mm in the perimeter zone. One single canister can cover approximately up to 140m 2 of central zone. SUBSTRATE QUALITY The substrate must offer sufficient strength and adhesion to resist the forces generated by wind suction. SUBSTRATE PREPARATION The substrate must be resistant to solvent, firm, clean, dry, free of stripping agents and free of oil and grease. 2/5

INSTALLATION INSTRUCTIONS APPLICATION GUIDLINE Based on the valid installation instructions of the relevant roof waterproofing membrane. In central zones apply 4 continuous beads of adhesive per meter (250mm centres) in parallel straight lines with a foam bead width of approx. 30 mm (130g/m2). In perimeter zones apply 6 continuous beads of adhesive per meter (166mm centres) with a liquid bead width of approx. 30 mm (195g/m2). Do not apply more adhesive than can be covered in 5 minutes. The insulation boards or vapour control layer must be laid and pressed into the adhesive immediately after spray application. The pressure and flow of the adhesive should be controlled by the black valve on the spray gun see fig 6. The distance of the spray gun from the substrate will need to be adjusted accordingly. Please note that the spray tip used with other Sika spray products is not used with! The end of the spray gun will require cleaning in between spraying. When bonding insulation boards it is recommended that periodic checks are carried out to check that the adhesive ridges have been squeezed flat. Do this by gently lifting the insulation material at the leading edge. This is especially important on very uneven substrates. APPLICATION METHOD GENERAL INFORMATION Based on the valid installation instructions of the relevant roof waterproofing membrane. The canister and gun will remain usable for 2 weeks after opening. If you do not intend to use the system within this time the adhesive in the hose and gun should be renewed by purging approx. 250ml of adhesive through the system every 2 weeks. If the system is not going to be used for longer than 2 weeks we recommend flushing the gun and hose with the Sika Canister Flushing System. Once canister is use is empty, the gun/hose can be transferred to a new canister. CANISTER SET UP It is important to set up your Canister Adhesive correctly before use to ensure the best possible performance and to avoid leakage or system failure. 01. Remove the black cap form the canister valve. 02. Attach the braided hose to the canister valve (using the small nut) and attach the other end of the braided hose to the spray gun (using the large nut). Tighten with a spanner. 03. Attach the other end of the braided hose to the spray gun (using the large nut). Tighten with a spanner. If there is a spray tip fitted remove this as it is not used with. 3/5

04. Fully open the valve on the canister. 05. Pull the trigger on the spray gun to apply adhesive. 06. Adjust the flow and pressure by turning the black valve on the spraygun anti clockwise until you have a spray of approximately 30mm in width. CANISTER MAINTENANCE GUIDE Once work has been completed, ensure the valve on the canister remains open. Failure to do this may cause the adhesive to block the hose. 01. Turn the spray gun off by turning the black valve clockwise until it is fully closed. CANISTER FLUSHING SYSTEM 01. Ensure the valve on the canister is completely turned off before attaching the assembly. 02. Unscrew the hose from the canister valve. 03. Attach the assembly to the valve. Ensure the assembly remains upright whilst you tighten the nut on it. Attach the hose to the assembly. Ensure the assembly remains upright whilst you tighten the hose. 03. Check the tap on the assembly is off before applying the Sika Spray Cleaner. Screw the Sika Spray Cleaner into the hose and open the red valve. 04. Aiming the gun into a waste container, apply pressure to the trigger on the gun to push Sika Spray Cleaner trough the hose and gun until the adhesive starts to dispense. Keep pressure on the trigger until the hose and gun are thoroughly cleaned. CANISTER DISPOSAL SYSTEM 01. The canister contains compressed gas. It should be emptied by carefully opening the valve, which will release any excess adhesive and/or pressure. Allow any excess adhesive and/or pressure to fully escape into a suitable container. Leave the valve open. Once the canister is empty and completely depressurized, the circular disk can be pierced using a non ferrous bar/rod. Allow any remaining adhesive to cure. The empty depressurized canister should be disposed/recycled in accordance to site regulation. 4/5

TOOL CLEANING INSTALLATION VALUE BASE LOCAL RESTRICTIONS HEALTH AND SAFETY INFORMATION LEGAL NOTES Tools and equipment must be cleaned with Sika Spray Cleaner or Sarna Cleaner immediately after use. The hose and application gun can be cleaned with the flush adaptor and Sika Spray Cleaner. Installation works to be carried out only by Registered Sika Sarnafil Roofing Contractors. Temperature limits for the installation of the adhesive: Substrate temperature: At least +5 C Ambient temperature: At least +5 C Installation of some ancillary products, e.g. contact adhesives / cleaners is limited to temperatures above +5 C. Please observe information given by s. Special measures may be compulsory for installation below +5 C ambient temperature due to safety requirements in accordance with national regulations. All technical data stated in this are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Please note that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local for the exact description of the application fields. For information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Material Safety Data Sheet containing physical, ecological, toxicological and other safety related data. The information, and, in particular, the recommendations relating to the application and end use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local for the product concerned, copies of which will be supplied on request. It may be necessary to adapt the above disclaimer to specific local laws and regulations. Version given by Phone: Fax: Mail: 5/5