SECTION TESTING, ADJUSTING, AND BALANCING CONTRACT NO SECTION TESTING, ADJUSTING, AND BALANCING

Similar documents
SECTION TESTING ADJUSTING AND BALANCING FOR HVAC

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

GM Series Dual-Block Multi-Function Gas Control Valves

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

FXT. FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS

APPENDIX A SAMPLE FHT SPECIFICATION (This recommended FHT specification is available from

FMU4X, FMC4X FMU4P, FMC4P

MANAGEMENT PROCEDURE FOR LABORATORY VENTILATION

Cover Page for Lab Report Group Portion. Pump Performance

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

M-06 Nitrogen Generator (Nitrogen Making Machine)

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, operating and maintenance Instructions for Seemag bypass level indicator

LENNOX SLP98UHV DIAGNOSTIC CODES

Gerald D. Anderson. Education Technical Specialist

Installation Operation Maintenance

BACK PRESSURE / SUSTAINING

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

BACK PRESSURE / SUSTAINING

WaterSource Heat Pump Hose Kit Performance Specification-Summary

Fisher DVI Desuperheater Venturi Inline

CASED HORIZONTAL FURNACE COIL. Model CK3B. Form No. SS-CK3B-01 FEATURES

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Reset Volume Controller 2 Reversing Relay 3 Air Valve Actuator 4 Lower-of-Two-Pressures Relay 4 Diverting Relay 5 Higher-of-Two-Pressures Relay 5

Ventam 85 Installation & Commissioning Instructions

acculink platinum zv zoning system

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios

KKT Training Series: ECO Series, Preventative Maintenance

GAS FUEL VALVE FORM AGV5 OM 8-03

E2.14 Control of Hazardous Energy. Effective Date: 03/01/2018

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Kansas State University Fume Hood Operation

Technical vs. Process Commissioning Final Exam: Functional Performance Testing

Vehicle-mounted meters, pump supplied

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

SDX Submersible Depth Transmitter User Manual

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Vehicle- or rack-mounted liquefied gas meters, pump supplied

VTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS

Evaporator (DX) Freon Applications 1 12 Tons MHF

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Model PDT Dewpoint Transmitter

SDX Submersible Depth Transmitter User Manual

553 Series.

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

LABORATORY FUME HOOD SPECIFICATION AND MAINTENANCE PROGRAM

The routine maintenance and inspection of local exhaust ventilation (LEV)

HYDROSTATIC LEAK TEST PROCEDURE

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

MIL-STD-883G METHOD

PRESCOTT SCHOOL DISTRICT NO South A Street Prescott, WA The Control of Hazardous Energy (Lockout/Tagout)

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Spirax Compact FREME Flash Recovery Energy Management Equipment

Float Operated Level Controllers

ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN

TExT Thorough Examination & Test of LEV Local Exhaust Ventilation Systems

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

SPECIFICATIONS ATTENTION

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

This test shall be carried out on all vehicles equipped with open type traction batteries.

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

CTG Certification Protocol -- Version 3.0 SUMMARY

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

Design DSA Steam-Atomized Desuperheater

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

BS Series Basket Strainer

Lockout/Tagout Training Overview. Safety Fest 2013

Level MEASUREMENT 1/2016

Piped Air SCBA Refilling System Standard

LPG DRIVER ATTENDED TRANSPORT LOADING

Part IV: Troubleshooting

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Section GAS CHLORINATION SYSTEM

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

Scald Protection 3-Way Thermostatic Mixing Valve

MECHANICAL EQUIPMENTS: COMPRESSORS, PUMPS, SEALS, SPEED DRIVES, CONTROL VALVES & ACTUATORS & SAFETY RELIEF VALVES

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

Tradition & Technology

LOCKOUT/TAGOUT PROGRAM

The Discussion of this exercise covers the following points:

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

CLARKES ERO FEEDER MANUAL

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100

SERIES 100 PACKAGED ROOFTOP UNIT WITH IPU CONTROL

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Propane Conversion Kit Instruction

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Product Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)

SINGLE VALVE WITH LOW-FLOW BYPASS

Transcription:

SECTION 15990 TESTING, ADJUSTING, AND BALANCING PART 1 -GENERAL 1.01 GENERAL A. This section of the Specifications covers testing and balancing of environmental systems, including, but not limited to distribution systems and the connected equipment and apparatus. The testing and balancing of all environmental systems shall be the responsibility of a single Testing, Adjusting, and Balancing (TAB) firm. B. Related Work Specified Elsewhere: General Requirements of Division One and Section 15010 "Basic Mechanical Requirements," pertain to and are hereby made part of the Work of this section of the Specifications. 1.02 SECTION INCLUDES A. Testing, adjustment, and balancing of air systems (supply, exhaust and ventilation). B. Testing, adjustment, and balancing of hydronic systems. C. Measurement of final operating condition of environmental systems. D. Space pressurization testing and adjusting. E. Vibration measuring. F. Verifying that automatic control devices are functioning properly. G. Reporting results of activities and procedures specified in this Section. 1.03 RELATED SECTIONS A. Section 01650 System Startup, Testing, and Training. B. Section 15010 - Basic Mechanical Requirements. C. Section 15995 Mechanical System Commissioning 1.04 ALLOWANCES A. Allowance includes testing, adjusting, and balancing of mechanical systems. Work is included in this section and is part of the Contract Sum/Price. 1.05 DEFINITIONS A. Adjust: To regulate fluid flow rate and air patterns at the terminal equipment, such as to reduce fan speed or adjust a damper. B. AABC: Associated Air Balance Council. C. Balance: To proportion flows within the distribution system, including submains, branches, and terminals, according to indicated quantities. 15990-1

D. Barrier or Boundary: Construction, either vertical or horizontal, such as walls, floors, and ceilings that are designed and constructed to restrict the movement of airflow, smoke, odors, and other pollutants. E. Draft: A current of air, when referring to localized effect caused by one or more factors of high air velocity, low ambient temperature, or direction of airflow, whereby more heat is withdrawn from a person's skin than is normally dissipated. F. NC: Noise criteria. G. NEBB: National Environmental Balancing Bureau. H. Procedure: An approach to and execution of a sequence of work operations to yield repeatable results. I. RC: Room criteria. J. Report Forms: Test data sheets for recording test data in logical order. K. Smoke-Control System: An engineered system that uses fans to produce airflow and pressure differences across barriers to limit smoke movement. L. Smoke-Control Zone: A space within a building that is enclosed by smoke barriers and is a part of a zoned smoke-control system. M. Stair Pressurization System: A type of smoke-control system that is intended to positively pressurize stair towers with outdoor air by using fans to keep smoke from contaminating the stair towers during an alarm condition. N. Static Head: The pressure due to the weight of the fluid above the point of measurement. In a closed system, static head is equal on both sides of the pump. O. Suction Head: The height of fluid surface above the centerline of the pump on the suction side. P. System Effect: A phenomenon that can create undesired or unpredicted conditions that cause reduced capacities in all or part of a system. Q. System Effect Factors: Allowances used to calculate a reduction of the performance ratings of a fan when installed under conditions different from those presented when the fan was performance tested. R. TAB: Testing, adjusting, and balancing. S. TABB: Testing, Adjusting, and Balancing Bureau. T. Terminal: A point where the controlled medium, such as fluid or energy, enters or leaves the distribution system. U. Test: A procedure to determine quantitative performance of systems or equipment. V. Testing, Adjusting, and Balancing (TAB) Firm: The entity responsible for performing and reporting TAB procedures. 1.06 REFERENCES 15990-2

A. Materials and workmanship shall conform to the latest issue of all industry standards, publications, or regulations referenced in this section and with the following references as applicable. Refer to Section 15010 for listing of issuing organizations or agencies. B. Applicable Standards: 1.07 SUBMITTALS 1. Associated Air Balance Council (AABC): a. National Standards for Total System Balance. 2. Air Diffusion Council (ADC): a. Test Code for Grilles, Registers, and Diffusers. 3. American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) a. ASHRAE 111 - Practices for Measurement, Testing, Adjusting, and Balancing of Building Heating, Ventilation, Air-conditioning, and Refrigeration Systems. 4. International Building Code (IBC) with the Denver Amendments 5. International Fire Code (IFC) with the Denver Amendments 6. National Environmental Balancing Bureau (NEBB): a. Procedural Standards for Testing, Adjusting, and Balancing of Environmental Systems. 7. Sheet Metal and Air Conditioning Contractor's National Association (SMACNA): a. HVAC Systems Testing, Adjusting, and Balancing. A. Submit name of adjusting and balancing agency for approval within thirty (30) days after award of Contract to ensure that the TAB firm has met the requirements this section of the Specifications and is on the project from the outset of construction. B. All TAB submittals shall be electronically submitted in PDF format to the DIA Project Manager and directly to the DIA Mechanical Engineer Lee Walinchus, lee.walinchus@diadenever.net. C. LEED Submittal: 1. Air-Balance Report for LEED Prerequisite EQ 1: Documentation of work performed for ASHRAE 62.1, Section 7.2.2, "Air Balancing." D. Field Reports: Submit under provisions of Section 15010. E. Field Reports: Indicate deficiencies in systems that would prevent proper testing, adjusting, and balancing of systems and equipment to achieve specified performance. F. Prior to commencing work, submit report forms or outlines indicating adjusting, balancing, and equipment data required. G. Submit draft copies of report for review prior to final acceptance of Project. Provide final copies for DIA Project Manager and for inclusion in operating and maintenance manuals. H. Include detailed procedures, agenda, sample report forms and copy of AABC National Project Performance Guaranty prior to commencing system balance. I. Test Reports: Indicate data on AABC National Standards for Total System Balance forms, or forms prepared following ASHRAE 111, NEBB or TABB forms. When necessary, supplement with forms containing information indicated in Schedules. 15990-3

J. Final Report: At least fifteen (15) days prior to Contractor's request for final inspection, submit in letter size, a single PDF file of the final test report on applicable reporting forms for review. Each individual final reporting form must bear the signature of the person who recorded data and that of the reporting organization. Identify instruments of all types which were used and last date of calibration of each. Report shall include all items listed in PART 3- Execution. 1. A statement outlining all abnormal or notable conditions not covered in above data. 2. Proposed resolutions to equipment that is performing outside of the specified performance ranges. K. As Built Plans shall be 24x36 and provided in the same electronic format and manner as described above. 1.08 PROJECT RECORD DOCUMENTS A. Record actual locations of flow measuring stations. 1.09 QUALITY ASSURANCE A. Perform total system balance in accordance with AABC National Standards for Field Measurement and Instrumentation, Total System Balance, or ASHRAE 111, or NEBB Procedural Standards for Testing, Balancing and Adjusting of Environmental Systems. 1.10 QUALIFICATIONS A. TAB Contractor Qualifications: Engage a TAB entity with minimum of three years documented experience and certified by AABC, NEBB, or TABB. 1.11 COORDINATION 1. TAB Field Supervisor: Employee of the TAB contractor and certified by AABC, NEBB, or TABB or registered Colorado Professional Engineer experienced in performance of this Work. 2. TAB Technician: Employee of the TAB contractor and who is certified by AABC, NEBB, or TABB as a TAB technician. A. Coordinate the efforts of factory-authorized service representatives for systems and equipment, HVAC controls installers, and other mechanics to operate HVAC systems and equipment to support and assist TAB activities. B. Notice: Notify the DIA Project Manager, DIA Mechanical Inspector and DIA Mechanical Engineer in writing a minimum of 72 hours prior to testing of any equipment and/or systems. Include scheduled test dates and times. C. Perform TAB after leakage and pressure tests on air and water distribution systems have been satisfactorily completed. 1.12 PRE-BALANCING CONFERENCE A. Convene a conference one week prior to commencing work of this section. B. Attendance shall include representatives of all systems and equipment Installers having performed, or in the process of performing, project work subject to testing, balancing, and adjustment by the TAB firm. 15990-4

C. Conference agenda shall include review of status of installation and completion of each system requiring testing balancing and adjusting, for the purpose of confirming that the schedule of work to be performed will be planned so as to ensure readiness of systems. 1.13 SEQUENCING AND SCHEDULING A. Sequence work to commence after completion of systems and schedule completion of work before Substantial Completion of Project. B. Schedule and provide assistance in final adjustment and test of life safety system with Fire Authority. 1.14 WARRANTY A. Warranty of all equipment described in this Section shall meet warranty requirements of Section 15010 - Basic Mechanical Requirements. B. National Project Performance Guarantee: Provide a guarantee on AABC's "National Standards for Testing and Balancing Heating, Ventilating, and Air Conditioning Systems" forms stating that AABC will assist in completing requirements of the Contract Documents if TAB firm fails to comply with the Contract Documents. Duration of Guarantee shall be 180 days. Guarantee includes the following provisions: C. Special Guarantee: Provide a guarantee on NEBB forms stating that NEBB will assist in completing requirements of the Contract Documents if TAB firm fails to comply with the Contract Documents. Duration of Guarantee shall be 180 days. Guarantee shall include the following provisions: 1. The certified TAB firm has tested and balanced systems according to the Contract Documents. 2. Systems are balanced to optimum performance capabilities within design and installation limits. PART 2 - PRODUCTS - NOT USED. PART 3 - EXECUTION 3.01 AGENCIES A. Subject to conformance with specified requirements, the following agencies are acceptable: 3.02 EXAMINATION 1. Able Balance Corp. 2. Griffith Engineering Service. 3. Jedi Balancing, Inc. 4. JPG Engineering, Inc. 5. TAB Services, Inc. 6. Substitutions: Under provisions of Section 15010. A. Verify that systems are complete and operable before commencing work. Ensure the following conditions: 1. Systems are started and operating in a safe and normal condition. 15990-5

2. Temperature control systems are installed complete and operable. 3. Proper thermal overload protection is in place for electrical equipment. 4. Final filters are clean and in place. If required, install temporary media in addition to final filters. 5. Duct systems are clean of debris. 6. Fans are rotating correctly. 7. Fire, smoke and volume dampers are in place and open. 8. Air coil fins are cleaned and combed. 9. Access doors are closed and duct end caps are in place. 10. Air outlets are installed and connected. 11. Duct system leakage is minimized. 12. Return air paths are not obstructed (i.e. walls to structure). 13. Hydronic systems are flushed, filled, and vented. 14. Pumps are rotating correctly. 15. Proper strainer baskets are clean and in place. 16. Service and balance valves are open. B. Submit field reports. Report defects and deficiencies noted during performance of services, which prevent system balance. C. Beginning of work means acceptance of existing conditions. 3.03 PREPARATION A. Provide instruments required for testing, adjusting, and balancing operations. Make instruments available to DIA Project Manager to facilitate spot checks during testing. B. Provide additional balancing devices as required. 3.04 INSTALLATION TOLERANCES A. Set HVAC system airflow and water flow rates within the following tolerances: 1. Supply, Return, and Exhaust Fans and Equipment with Fans: minus 5 to plus 10%. 2. Air Outlets and Inlets: 0 to plus 10%. 3. Heating-Water Flow Rate: 0 to plus 10%. 4. Cooling-Water Flow Rate: 0 to plus 5%. B. Supply, return and exhaust air flow rate tolerances shall be identical for each system. (IE: If an AHU is balanced to 97% of design air flow rate, the corresponding exhaust fan should match this 97% tolerance.) 3.05 ADJUSTING A. Ensure recorded data represents actual measured or observed conditions. B. Permanently mark settings of valves, dampers, and other adjustment devices allowing settings to be restored. Set and lock memory stops. 15990-6

C. After adjustment, take measurements to verify balance has not been disrupted or that such disruption has been rectified. D. Leave systems in proper working order, replacing belt guards, closing access doors, closing doors to electrical switch boxes, and restoring thermostats to specified settings. E. Check and adjust systems approximately six months after final acceptance and submit report. 3.06 TEMPERATURE CONTROLS A. Verify that controllers are calibrated and commissioned. B. Check transmitter and controller locations and note conditions that would adversely affect control functions. C. Record controller settings and note variances between set points and actual measurements. D. Check the operation of limiting controllers (i.e., high- and low-temperature controllers). E. Check free travel and proper operation of control devices such as damper and valve operators. F. Check the sequence of operation of control devices. Note air pressures and device positions and correlate with airflow and water flow measurements. Note the speed of response to input changes. G. Check the interaction of electrically operated switch transducers. H. Check the interaction of interlock and lockout systems. I. Check main control supply-air pressure and observe compressor and dryer operations. J. Record voltages of power supply and controller output. Determine whether the system operates on a grounded or non-grounded power supply. K. Note operation of electric actuators using spring return for proper fail-safe operations. L. VAV Boxes: Verify the following and report any discrepancies to the responsible installer: 1. Velocity pressure sensor is receiving the proper signal and is then sending that signal to the regulator. 2. Primary air damper will allow design flows without going to end point settings. 3. Thermostats are calibrated. 4. Control pressure is compatible with the primary damper motor range, dead band range and heating electric P.E. or valve motor range. 5. Direct acting or reverse acting controls are properly installed. 6. Primary fan static pressure controls are receiving the proper signal in their installed location and transmitting this signal to the fan controller. M. Include a written certificate (include in balance report) that the above items are functioning properly. 15990-7

3.07 GENERAL PROCEDURES FOR TESTING AND BALANCING: A. Perform testing and balancing procedures on each system according to the procedures contained in NEBB's "Procedural Standards for Testing, Adjusting, and Balancing of Environmental Systems" and this Section. B. Cut insulation, ducts, pipes, and equipment cabinets for installation of test probes to the minimum extent necessary to allow adequate performance of procedures. After testing and balancing, close probe holes and patch insulation with new materials identical to those removed. Restore vapor barrier and finish according to insulation Specifications for this Project. C. Mark equipment and balancing device settings with paint or other suitable, permanent identification material, including damper-control positions, valve position indicators, fanspeed-control levers, and similar controls and devices, to show final settings. D. Take and report testing and balancing measurements in inch-pound (IP) units. 3.08 GENERAL PROCEDURES FOR BALANCING AIR SYSTEMS A. Prepare test reports for both fans and outlets. Obtain manufacturer's outlet factors and recommended testing procedures. Crosscheck the summation of required outlet volumes with required fan volumes. B. Prepare schematic diagrams of systems' "as-built" duct layouts. C. For variable-air-volume systems, develop a plan to simulate diversity. D. Determine the best locations in main and branch ducts for accurate duct airflow measurements. E. Check airflow patterns from the outside-air louvers and dampers and the return- and exhaust-air dampers, through the supply-fan discharge and mixing dampers. F. Locate start-stop and disconnect switches, electrical interlocks, and motor starters. G. Verify that motor starters are equipped with properly sized thermal protection. H. Check dampers for proper position to achieve desired airflow path. I. Check for airflow blockages. J. Check condensate drains for proper connections and functioning. K. Check for proper sealing of air-handling unit components. L. Check for proper sealing of air duct system. 3.09 PROCEDURES FOR CONSTANT-VOLUME AIR SYSTEMS A. Adjust fans to deliver total indicated airflows within the maximum allowable fan speed listed by fan manufacturer. 1. Measure fan static pressures to determine actual static pressure as follows: a. Measure outlet static pressure as far downstream from the fan as practicable and upstream from restrictions in ducts such as elbows and transitions. 15990-8

b. Measure static pressure directly at the fan outlet or through the flexible connection. c. Measure inlet static pressure of single-inlet fans in the inlet duct as near the fan as possible, upstream from flexible connection and downstream from duct restrictions. d. Measure inlet static pressure of double-inlet fans through the wall of the plenum that houses the fan. 2. Measure static pressure across each component that makes up an air-handling unit, rooftop unit, and other air-handling and -treating equipment. a. Simulate dirty filter operation and record the point at which maintenance personnel must change filters. 3. Measure static pressures entering and leaving other devices such as sound traps, heat recovery equipment, and air washers, under final balanced conditions. 4. Compare design data with installed conditions to determine variations in design static pressures versus actual static pressures. Compare actual system effect factors with calculated system effect factors to identify where variations occur. Recommend corrective action to align design and actual conditions. 5. Obtain approval from Engineer for adjustment of fan speed higher or lower than indicated speed. Make required adjustments to pulley sizes, motor sizes, and electrical connections to accommodate fan-speed changes. 6. Do not make fan-speed adjustments that result in motor overload. Consult equipment manufacturers about fan-speed safety factors. Modulate dampers and measure fanmotor amperage to ensure that no overload will occur. Measure amperage in full cooling, full heating, economizer, and any other operating modes to determine the maximum required brake horsepower. B. Adjust volume dampers for main duct, sub-main ducts, and major branch ducts to indicated airflows within specified tolerances. 1. Measure static pressure at a point downstream from the balancing damper and adjust volume dampers until the proper static pressure is achieved. a. Where sufficient space in sub-main and branch ducts is unavailable for Pitot-tube traverse measurements, measure airflow at terminal outlets and inlets and calculate the total airflow for that zone. 2. Remeasure each sub-main and branch duct after all have been adjusted. Continue to adjust sub-main and branch ducts to indicated airflows within specified tolerances. C. Measure terminal outlets and inlets without making adjustments. 1. Measure terminal outlets using a direct-reading hood or outlet manufacturer's written instructions and calculating factors. D. Adjust terminal outlets and inlets for each space to indicated airflows within specified tolerances of indicated values. Make adjustments using volume dampers rather than extractors and the dampers at air terminals. 1. Adjust each outlet in same room or space to within specified tolerances of indicated quantities without generating noise levels above the limitations prescribed by the Contract Documents. 2. Adjust patterns of adjustable outlets for proper distribution without drafts. 3.10 PROCEDURES FOR VARIABLE-AIR-VOLUME SYSTEMS A. Pressure-Dependent, Variable-Air-Volume Systems: After the fan systems have been 15990-9

adjusted, adjust the variable-air-volume systems as follows: 1. Balance systems similar to constant-volume air systems. 2. Set terminal units and supply fan at full-airflow condition. 3. Adjust inlet dampers of each terminal unit to indicated airflow and verify operation of the static-pressure controller. When total airflow is correct, balance the air outlets downstream from terminal units as described for constant-volume air systems. 4. Readjust fan airflow for final maximum readings. 5. Measure operating static pressure at the sensor that controls the supply fan, if one is installed, and verify operation of the static-pressure controller. 6. Set supply fan at minimum airflow if minimum airflow is indicated. Measure static pressure to verify that it is being maintained by the controller. 7. Set terminal units at minimum airflow and adjust controller or regulator to deliver the designed minimum airflow. Check air outlets for a proportional reduction in airflow as described for constant-volume air systems. a. If air outlets are out of balance at minimum airflow, report the condition but leave the outlets balanced for maximum airflow. 8. Measure the return airflow to the fan while operating at maximum return airflow and minimum outside airflow. Adjust the fan and balance the return-air ducts and inlets as described for constant-volume air systems. 3.11 GENERAL PROCEDURES FOR HYDRONIC SYSTEMS A. Prepare test reports with pertinent design data and number in sequence starting at pump to end of system. Check the sum of branch-circuit flows against approved pump flow rate. Correct variations that exceed plus or minus 5%. B. Prepare schematic diagrams of systems' "as-constructed" piping layouts. C. Prepare hydronic systems for testing and balancing according to the following, in addition to the general preparation procedures specified above: 1. Open all manual valves for maximum flow. 2. Check expansion tank liquid level. 3. Check makeup-water-station pressure gage for adequate pressure for highest vent. 4. Check flow-control valves for specified sequence of operation and set at indicated flow. 5. Set differential-pressure control valves at the specified differential pressure. Do not set at fully closed position when pump is positive-displacement type unless several terminal valves are kept open. 6. Set system controls so automatic valves are wide open to heat exchangers. 7. Check pump-motor load. If motor is overloaded, throttle main flow-balancing device so motor nameplate rating is not exceeded. 8. Check air vents for a forceful liquid flow exiting from vents when manually operated. 3.12 PROCEDURES FOR HYDRONIC SYSTEMS A. Measure water flow at pumps. Use the following procedures, except for positivedisplacement pumps: 1. Verify impeller size by operating the pump with the discharge valve closed. Read 15990-10

pressure differential across the pump. Convert pressure to head and correct for differences in gage heights. Note the point on manufacturer's pump curve at zero flow and verify that the pump has the intended impeller size. 2. Check system resistance. With all valves open, read pressure differential across the pump and mark pump manufacturer's head-capacity curve. Adjust pump discharge valve until indicated water flow is achieved. 3. Verify pump-motor brake horsepower. Calculate the intended brake horsepower for the system based on pump manufacturer's performance data. Compare calculated brake horsepower with nameplate data on the pump motor. Report conditions where actual amperage exceeds motor nameplate amperage. 4. Report flow rates that are not within plus or minus 5% of design. B. Set calibrated balancing valves, if installed, at calculated presettings. C. Measure flow at all stations and adjust, where necessary, to obtain first balance. 1. System components that have Cv rating or an accurately cataloged flow-pressuredrop relationship may be used as a flow-indicating device. D. Measure flow at main balancing station and set main balancing device to achieve flow that is 5% greater than indicated flow. E. Adjust balancing stations to within specified tolerances of indicated flow rate as follows: 1. Determine the balancing station with the highest percentage over indicated flow. 2. Adjust each station in turn, beginning with the station with the highest percentage over indicated flow and proceeding to the station with the lowest percentage over indicated flow. 3. Record settings and mark balancing devices. F. Measure pump flow rate and make final measurements of pump amperage, voltage, rpm, pump heads, and systems' pressures and temperatures including outdoor-air temperature. G. Measure the differential-pressure control valve settings existing at the conclusions of balancing. 3.13 PROCEDURES FOR HEAT EXCHANGERS A. Measure water flow through all circuits. B. Adjust water flow to within specified tolerances. C. Measure inlet and outlet water temperatures. D. Check the setting and operation of safety and relief valves. Record settings. 3.14 PROCEDURES FOR MOTORS A. Motors, 1/2 HP and Larger: Test at final balanced conditions and record the following data: 1. Manufacturer, model, and serial numbers. 2. Motor horsepower rating. 3. Motor rpm. 4. Efficiency rating. 15990-11

5. Nameplate and measured voltage, each phase. 6. Nameplate and measured amperage, each phase. 7. Starter thermal-protection-element rating. B. Motors Driven by Variable-Frequency Controllers: Test for proper operation at speeds varying from minimum to maximum. Test the manual bypass for the controller to prove proper operation. Record observations, including controller manufacturer, model and serial numbers, and nameplate data. 3.15 PROCEDURES FOR CHILLERS A. Balance water flow through each evaporator and condenser to within specified tolerances of indicated flow with all pumps operating. With only one chiller operating in a multiple chiller installation, do not exceed the flow for the maximum tube velocity recommended by the chiller manufacturer. Measure and record the following data with each chiller operating at design conditions: 1. Evaporator-water entering and leaving temperatures, pressure drop, and water flow. 2. If water-cooled chillers, condenser-water entering and leaving temperatures, pressure drop, and water flow. 3. Evaporator and condenser refrigerant temperatures and pressures, using instruments furnished by chiller manufacturer. 4. Power factor if factory-installed instrumentation is furnished for measuring kilowatt. 5. Kilowatt input if factory-installed instrumentation is furnished for measuring kilowatt. 6. Capacity: Calculate in tons of cooling. 7. If air-cooled chillers, verify condenser-fan rotation and record fan and motor data including number of fans and entering- and leaving-air temperatures. 3.16 PROCEDURES FOR COOLING TOWERS A. Shut off makeup water for the duration of the test, and verify that makeup and blow-down systems are fully operational after tests and before leaving the equipment. Perform the following tests and record the results: 1. Measure condenser-water flow to each cell of the cooling tower. 2. Measure entering- and leaving-water temperatures. 3. Measure wet- and dry-bulb temperatures of entering air. 4. Measure wet- and dry-bulb temperatures of leaving air. 5. Measure condenser-water flow rate recirculating through the cooling tower. 6. Measure cooling tower pump discharge pressure. 7. Adjust water level and feed rate of makeup-water system. 3.17 PROCEDURES FOR BOILERS A. Measure entering- and leaving-water temperatures and water flow. 3.18 PROCEDURES FOR HEAT-TRANSFER COILS A. Water Coils: Measure the following data for each coil: 1. Entering- and leaving-water temperature. 15990-12

2. Water flow rate. 3. Water pressure drop. 4. Dry-bulb temperature of entering and leaving air. 5. Wet-bulb temperature of entering and leaving air for cooling coils. 6. Airflow. 7. Air pressure drop. 3.19 PROCEDURES FOR SPACE PRESSURIZATION MEASUREMENTS AND ADJUSTMENTS A. Before testing for space pressurization, observe the space to verify the integrity of the space boundaries. Report deficiencies and postpone testing until after the reported deficiencies are corrected. B. Measure, adjust, and record the pressurization of each room, each zone, and each building by adjusting the supply, return, and exhaust airflows to achieve the indicated conditions. C. Measure space pressure differential where pressure is used as the design criteria, and measure airflow differential where differential airflow is used as the design criteria for space pressurization. 1. For pressure measurements, measure and record the pressure difference between the intended spaces at the door with all doors in the space closed. Record the highpressure side, low-pressure side, and pressure difference between each adjacent space. 2. Test room pressurization first, then zones, and finish with building pressurization. D. To achieve indicated pressurization, set the supply airflow to the indicated conditions and adjust the exhaust and return airflow to achieve the indicated pressure or airflow difference. E. For spaces with pressurization being monitored and controlled automatically, observe and adjust the controls to achieve the desired set point. 1. Compare the values of the measurements taken to the measured values of the control system instruments and report findings. 2. Check the repeatability of the controls by successive tests designed to temporarily alter the ability to achieve space pressurization. Test over pressurization and under pressurization, and observe and report on the system's ability to revert to the set point. 3. For spaces served by variable-air-volume supply and exhaust systems, measure space pressurization at indicated airflow and minimum airflow conditions. F. In spaces that employ multiple modes of operation, such as normal mode and emergency mode or occupied mode and unoccupied mode, measure, adjust, and record data for each operating mode. G. Record indicated conditions and corresponding initial and final measurements. Report deficiencies. 3.20 WATER SYSTEM PROCEDURE A. Adjust water systems to provide required or design quantities. 15990-13

B. Hydronic Systems with Meters: Use calibrated Venturi tubes, orifices, or other metered fittings and pressure gages to determine flow rates for system balance. On completion of the balance, the following information shall be recorded in the report: Flow meter or calibrated valve size and brand, required flow rate and pressure drop, valve settings on meters or valves with a readable scale, flow rate in both full coil flow and full bypass modes. C. Hydronic Systems Without Meters: Where flow metering devices are not installed, base flow balance on temperature difference across various heat transfer elements in the system. On completion of the balance the following information shall be recorded in the report: Design entering and leaving water temperature/pressure drop, final balance entering and leaving water temperature/pressure drop. D. The hydronic system(s) shall be balanced being certain that the path to one terminal is fully open. Total system flow shall be adjusted at pump by restricting the discharge balance valve. Indicate final valve position on report. E. Adjust systems to provide specified pressure drops and flows through heat transfer elements prior to thermal testing. Perform balancing by measurement of temperature differential in conjunction with air balancing. F. Effect system balance with automatic control valves fully open to heat transfer elements. Control valve bypass loops shall be set with the balancing valve to provide equal flow in either mode. Confirm in writing. G. Effect adjustment of water distribution systems by means of balancing cocks, valves, and fittings. Do not use service or shut-off valves for balancing unless indexed for balance point. H. Where available pump capacity is less than total flow requirements or individual system parts, full flow in one part may be simulated by temporary restriction of flow to other parts. 3.21 PROCEDURES FOR VIBRATION MEASUREMENTS A. Use a vibration meter meeting the following criteria: 1. Solid-state circuitry with a piezoelectric accelerometer. 2. Velocity range of 0.1 to 10 inches per second. 3. Displacement range of 1 to 100 mils. 4. Frequency range of at least 0 to 1000 Hz. 5. Capable of filtering unwanted frequencies. B. Calibrate the vibration meter before each day of testing. 1. Use a calibrator provided with the vibration meter. 2. Follow vibration meter and calibrator manufacturer's calibration procedures. C. Perform vibration measurements when other building and outdoor vibration sources are at a minimum level and will not influence measurements of equipment being tested. D. Perform vibration measurements after air and water balancing and equipment testing is complete. E. Clean equipment surfaces in contact with the vibration transducer. F. Position the vibration transducer according to manufacturer's written instructions and to avoid interference with the operation of the equipment being tested. 15990-14

G. Measure and record vibration on rotating equipment over 3 hp. H. Measure and record equipment vibration, bearing vibration, equipment base vibration, and building structure vibration. Record velocity and displacement readings in the horizontal, vertical, and axial planes. 1. Pumps: a. Pump Bearing: Drive end and opposite end. b. Motor Bearing: Drive end and opposite end. c. Pump Base: Top and side. d. Building: Floor. e. Piping: To and from the pump after flexible connections. 2. Fans and HVAC Equipment with Fans: a. Fan Bearing: Drive end and opposite end. b. Motor Bearing: Drive end and opposite end. c. Equipment Casing: Top and side. d. Equipment Base: Top and side. e. Building: Floor. f. Ductwork: To and from equipment after flexible connections. g. Piping: To and from equipment after flexible connections. 3. Chillers and HVAC Equipment with Compressors: a. Compressor Bearing: Drive end and opposite end. b. Motor Bearing: Drive end and opposite end. c. Equipment Casing: Top and side. d. Equipment Base: Top and side. e. Building: Floor. f. Piping: To and from equipment after flexible connections. I. For equipment with vibration isolation, take floor measurements with the vibration isolation blocked solid to the floor and with the vibration isolation floating. Calculate and report the differences. J. Inspect, measure, and record vibration isolation. 3.22 SCHEDULES 1. Verify that vibration isolation is installed in the required locations. 2. Verify that installation is level and plumb. 3. Verify that isolators are properly anchored. 4. For spring isolators, measure the compressed spring height, the spring OD, and the travel-to-solid distance. 5. Measure the operating clearance between each inertia base and the floor or concrete base below. Verify that there is unobstructed clearance between the bottom of the inertia base and the floor. A. Equipment Requiring Testing, Adjusting, and Balancing: 1. HVAC Pumps 2. Water Tube Boilers 3. Centrifugal Water Chillers 15990-15

4. Induced Draft Cooling Tower 5. Air Coils 6. Air Handling Units 7. Fans 8. Air Filters 9. Air Terminal Units 10. Air Inlets and Outlets 11. Controls Compressor 3.23 MOTOR STARTERS AND THERMAL HEATERS A. Coordinate the requirement for the exchange of thermal overloads as required for proper motor protection on magnetic and manual starters. Check for correct sizing and notify Installers responsible for supply of proper devices of corrections or replacements needed. 3.24 REPORT OF WORK A. General: Typewritten, or computer printout in letter-quality font, on standard bond paper, in three-ring binder, tabulated and divided into sections by tested and balanced systems. B. Include a certification sheet in front of binder signed and sealed by the certified testing and balancing engineer. 1. Include a list of instruments used for procedures, along with proof of calibration. C. Final Report Contents: In addition to certified field report data, include the following: 1. Pump curves. 2. Fan curves. 3. Manufacturers' test data. 4. Field test reports prepared by system and equipment installers. 5. Other information relative to equipment performance, but do not include Shop Drawings and Product Data. D. General Report Data: In addition to form titles and entries, include the following data in the final report, as applicable: 1. Title page. 2. Name and address of TAB firm. 3. Project name. 4. Project location. 5. Architect and Engineer's name and address. 6. Contractor's name and address. 7. Report date. 8. Signature of TAB firm who certifies the report. 9. Table of Contents with the total number of pages defined for each section of the report. Number each page in the report. 10. Summary of contents including the following: 15990-16

a. Indicated versus final performance. b. Final performance percentage of design performance. c. Equipment system or zone service d. Notable characteristics of systems. e. Description of system operation sequence if it varies from the Contract Documents. 11. Nomenclature sheets for each item of equipment. 12. A set of contract document drawings indicating 'as-built' conditions shall be included in the report with all terminals (VAV boxes, outlets, inlets, coils, unit heaters, etc.) and thermostat locations clearly marked and all equipment designated. Locations of all tests shall be clearly indicated. 13. Data for terminal units, including manufacturer, type size, and fittings. 14. Notes to explain why certain final data in the body of reports varies from indicated values and proposed resolutions for equipment measured outside of the acceptable specified ranges. 15. Test conditions for fans and pump performance forms including the following: a. Settings for outside-, return-, and exhaust-air dampers. b. Conditions of filters. c. Cooling coil, wet- and dry-bulb conditions. d. Fan drive settings including settings and percentage of maximum pitch diameter. e. Inlet vane settings for variable-air-volume systems. f. Settings for supply-air, static-pressure controller. g. Other system operating conditions that affect performance. E. System Diagrams: Include schematic layouts of air and hydronic distribution systems. Present each system with single-line diagram and include the following: 1. Quantities of outside, supply, return, and exhaust airflows. 2. Water flow rates. 3. Duct, outlet, and inlet sizes. 4. Pipe and valve sizes and locations. 5. Terminal units. 6. Balancing stations, locations, size, velocity and flow. 7. Position of balancing devices. F. Equipment measurements shall include the following information. 1. Instrument list including instrument, manufacturer, model, serial number, range, calibration date. 2. Data to be submitted for systems having electric motor drives, except as otherwise indicated, shall in all cases include the following to the extent applicable: a. Electric Motor data including manufacturer, HP, Voltage, phase, amperage (name plate, actual (in all operating modes), no load), service factor, efficiency, power factor, starter size (brand, model, enclosure type, installed thermal heaters and the rating of the heaters, required thermal heaters and the rating of the heaters if different than installed). b. For motors controlled by variable frequency controllers, test data shall include amperage at one-third, two-thirds, and full speed motor RPM. 15990-17

c. V-Belt Drive data including identification/location, required driven RPM; driven sheave (diameter and RPM), belt (size and quality), motor sheave (diameter and RPM), center to center distance (maximum, minimum and final). 3. Air Moving Equipment data including location, manufacturer, model, supply air flow (specified and actual), return air flow (specified and actual), outside air flow (specified and actual), total static pressure (specified and actual), inlet pressure, discharge pressure, fan RPM, motor and V-belt drive data. Include Manufacturer's fan curves. 4. Static pressure across each individual component of the system and the total system. 5. Exhaust Fan data including location, manufacturer, model, air flow (specified and actual), total static pressure (specified and actual), inlet pressure, discharge pressure (specified and actual), inlet pressure, discharge pressure, fan RPM, motor and V-belt drive data. Include Manufacturer's fan curves. 6. Outside/Return Air data including identification/ location, supply air flow (specified and actual), return air flow (specified and actual), outside air flow (specified and actual), return air temperature, outside air temperature, mixed air temperature (specified and actual). 7. Air Terminal Device data including air terminal number, room number/location, terminal type, terminal size, area factor, design velocity, design air flow, test (final) velocity, test (final) air flow, percent of design air flow. 8. Terminal Unit data including manufacturer, type (constant, variable, dual duct, reheat, fan powered parallel, fan powered-series), identification/number, location, model, size, minimum static pressure, minimum air flow (specified and actual), maximum air flow (specified and actual), inlet static pressure, fan air quantity (specified and actual) on fan powered terminal units. Include discharge air temperature for maximum cooling air flow, and for maximum heating air flow for units equipped with heating coils. 9. Duct Traverse data including system zone/branch, duct size, area, design velocity, design air flow, test velocity, test air flow, duct static pressure, air temperature, air correction factor. 10. Air Monitoring Station data including identification/ location, system, size, area, design velocity, design air flow, test (final) velocity, test (final) air flow. 11. Total CFM (required and final) for each fan system, including cabinet heaters, fan coils, etc. 12. Pump data including identification/number, manufacturer, size/model, impeller, service, flow rate (specified and actual), pressure drop (specified and actual), discharge pressure, suction pressure, total operating head pressure, shut-off (discharge and suction pressures), shut-off (total head pressure), and motor data. Include manufacturer's pump curves. 13. Chiller data including identification/number, manufacturer, capacity, model, evaporator leaving water temperature (specified and actual), evaporator pressure drop (specified and actual), evaporator water flow rate (specified and actual), condenser entering water temperature (specified and actual), condenser leaving water temperature (specified and actual), condenser pressure drop (specified and actual), condenser water flow rate (specified and actual), motor amperage. 14. Cooling Tower data including tower identification number, manufacturer, model, rated capacity, entering air WB temperature (specified and actual), leaving air WB temperature (specified and actual), ambient air DB temperature, condenser water entering temperature, condenser water leaving temperature, condenser water flow rate, fan RPM, motor data, wind velocity and direction. 15. Heat Exchanger data including identification/number, location, service, manufacturer, model, primary water entering temperature (specified and actual), primary water 15990-18

leaving temperature (specified and actual), primary water flow (specified and actual), primary water pressure drop (specified and actual), secondary water entering temperature (specified and actual), secondary water flow (specified and actual), secondary water pressure drop (specified and actual). 16. Boiler data including entering and leaving water temperature, gas flow rate, flue gas analysis (copy of manufacturer's analysis report), entering and leaving water pressures, and motor data (if applicable). 17. Cooling Coil data including identification/number, location, service, manufacturer, air flow (specified and actual), entering air DB and WB temperatures (specified and actual), leaving air DB and WB temperatures (specified and actual), water flow (specified and actual), water pressure drop (specified and actual), entering water temperature (specified and actual), leaving water temperature (specified and actual), air pressure drop (specified and actual). 18. Heating Coil data including identification/number, location, service, manufacturer, air flow (specified and actual), water flow (specified and actual), water pressure drop (specified and actual), entering and leaving water temperatures (specified and actual), entering and leaving air temperatures (specified and actual), air pressure drop (specified and actual). 19. Flow Measuring Station and Calibrated Balancing Valve data including identification, location, size, manufacturer, model, flow rate (specified and actual), pressure drop (specified and actual), station or valve calibrated setting. 20. Gas flow and pressure to each piece of mechanical equipment and gas pressure at meter under full flow. 21. Measurement of existing equipment data prior to new work start. a. Date of test on original equipment b. Equipment tag c. Inlet static pressure (inches WC) d. Outlet static pressure (inches WC) e. Outlet airflow (CFM) f. Coil entering air and water temperatures (F). g. Coil leaving air and water temperatures (F). h. Motor electrical data, HP, voltage and amperage at test time. 22. Measurement of existing equipment data upon completion of new work. a. Date of test on original equipment b. Equipment tag c. Inlet static pressure (inches WC) d. Outlet static pressure (inches WC) e. Outlet airflow (CFM) f. Coil entering air and water temperatures (F). g. Coil leaving air and water temperatures (F). h. Motor electrical data, HP, voltage and amperage at test time. 23. Vibration Test: Where vibration limitations are specified or shown on the drawings, work shall include measurement and reporting of as-installed systems performance, including the following data: a. Location of points: 1) Fan bearing, drive end 2) Fan bearing, opposite end 3) Motor bearing, center (if applicable) 4) Motor bearing, drive end 15990-19

5) Motor bearing, opposite end 6) Casing (bottom or top) 7) Casing (side) 8) Duct after flexible connection (discharge) 9) Duct after flexible connection (suction) b. Test readings: 1) Horizontal, velocity and displacement 2) Vertical, velocity and displacement 3) Axial, velocity and displacement c. Normally acceptable readings, velocity and acceleration d. Unusual conditions at time of test e. Vibration source (if non-complying) 3.25 INSPECTIONS 24. Indoor-Air Quality Measurement Reports for Each HVAC System: a. HVAC system designation. b. Date and time of test. c. Outdoor temperature, relative humidity, wind speed, and wind direction at start of test. d. Room number or similar description for each location. e. Measurements at each location. f. Observed deficiencies. 25. Instrument Calibration Reports: a. Report Data: 1) Instrument type and make. 2) Serial number. 3) Application. 4) Dates of use. 5) Dates of calibration. 26. Measurements outside of tolerance: If the final measurements differ from the design measurements in the final report by more than the tolerances allowed, the measurements shall be noted as "FAILED." TAB firm shall provide recommendations and/or solutions for resolving all FAILED measurements. A. Initial Inspection: 1. After testing and balancing are complete, operate each system and randomly check measurements to verify that the system is operating according to the final test and balance readings documented in the Final Report. 2. Randomly check the following for each system: a. Measure airflow of at least 10% of air outlets. b. Measure water flow of at least 5% of terminals. c. Measure room temperature at each thermostat/temperature sensor. Compare the reading to the set point. d. Measure sound levels at two locations. e. Measure space pressure of at least 10% of locations. f. Verify that balancing devices are marked with final balance position. g. Note deviations to the Contract Documents in the Final Report. B. Final Inspection: 1. After initial inspection is complete and evidence by random checks verifies that testing 15990-20

and balancing are complete and accurately documented in the final report, request that a final inspection be made by DIA Project Manager, DIA Mechanical Engineer or their designated representative(s). 2. TAB firm test and balance engineer shall conduct the inspection in the presence of DIA Project Manager, DIA Mechanical Engineer or their designated representative(s). 3. DIA Project Manager, DIA Mechanical Engineer or their designated representative(s) shall randomly select measurements documented in the final report to be rechecked. The rechecking shall be limited to either 10% of the total measurements recorded, or the extent of measurements that can be accomplished in a normal 8-hour business day. 4. If the rechecks yield measurements that differ from the measurements documented in the final report by more than the tolerances allowed, the measurements shall be noted as "FAILED." 5. If the number of "FAILED" measurements is greater than 10% of the total measurements checked during the final inspection, the testing and balancing shall be considered incomplete and shall be rejected. 6. TAB firm shall recheck all measurements and make adjustments. Revise the final report and balancing device settings to include all changes and resubmit the final report. 7. Request a second final inspection. If the second final inspection also fails, Owner shall contract the services of another TAB firm to complete the testing and balancing in accordance with the Contract Documents and deduct the cost of the services from the final payment. 3.26 ADDITIONAL TESTS A. Within 90 days of completing TAB, perform additional testing and balancing to verify that balanced conditions are being maintained throughout and to correct unusual conditions. B. Seasonal Periods: If initial TAB procedures were not performed during near-peak summer and winter conditions, perform additional testing, inspecting, and adjusting during near-peak summer and winter conditions. PART 4 - MEASUREMENT 4.01 METHOD OF MEASUREMENT A. No separate measurement will be made for work under this Section. PART 5 - PAYMENT 5.01 PAYMENT A. No separate payment will be made for work under this section. The cost of the work described in this section shall be included in the Lump Sum Contract price. END OF SECTION 15990 15990-21