Fio 2.2 Smart add-on for gas pressure Regulators

Similar documents
FIO > Five In One The SMART regulator

SonoMeter 30 Energy Meters

ASX 176 Axial Pressure regulator

Electronic Volume Correctors

CCT-7320/ROC-2313 Reverse Osmosis Controller

SVEA II GSM Connector User Manual

Connect with Confidence NO POWER NO PROBLEM

TH-1800-T TRX-700-CNG Converter

Pneumatic high-pressure controller Model CPC7000

TANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box

Tightness controls TC 1 3 and TC 4

ACV-10 Automatic Control Valve

Aperval Pressure Regulators

REASONS FOR THE DEVELOPMENT

BUBBLER CONTROL SYSTEM

Electronic gas volume corrector model DGVC-04

Supplementary Operator s Manual 42/24-14 EN Rev. 3

C-Flow Coriolis Mass Flow Meters

Pneumatic high-pressure controller Model CPC7000

Code Basic module and level control complete with optionals code

Ultrasonic level transmitter and indicator

Tightness control TC. Product brochure GB 3 Edition AGA

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Automatic Isokinetic Sampler. ST5 Evo

Norval Pressure regulator

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

SPECIFICATIONS ATTENTION

Intrinsically safe solenoid valves on/off controls - ATEX certification

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Dival 500 Pressure Regulators

Flowatch Multiphase Flow Meter

G4S G4A1KY RESIDENTIAL CONVERSION KIT LOW PRESSURE CONVERSION KIT MEDIUM PRESSURE CONVERSION KIT HIGH PRESSURE CONVERSION KIT ULTRASONIC GAS METER

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

SonoSelect 10 and SonoSafe 10 energy meters

EasySas. The most advanced airlock electronics on the market. Recyclable product. Eco-design. Energy savings

Glass tube flowmeters Series 2000

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

SINGLE VALVE WITH LOW-FLOW BYPASS

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

Stand-Alone Bubble Detection System

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

Aquavar SOLO 2 Frequently Asked Questions

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Manual Weighingblock VB2 series and Uniscale

Technical Information Conducal CLY421

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

High-performance submersible pressure transmitter For level measurement Model LH-20

Surge suppressor To perform its intended functions, an AEI site must have the components listed above and shown in Fig. 4.1.

Programmable Submersible Level Transmitters

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

HumiSys HF High Flow RH Generator

EPP4 Pressure Regulator Basic G 1/4"

Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands)

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

OC Panel High Limit Aquastat Kit, Manual Reset p/n

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

UNIVERSAL MASK TEST SYSTEM

Columbus Instruments

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ERZ 2000-NG Flow Computer

BUBBLER CONTROL SYSTEM

SCIENCE LAB UTILITY CONTROLS

Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS

The Ins and Outs of I/P Transducers

I/P Transducer Positioner Module

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

RAM 4021-DPX Operation Manual

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Installing a Probe. Typical Installation

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Manifolds & pressure reducing sets

780S Ultra High Purity Series

Mass Flow Controller (MFC) for Gases

Reverse Osmosis System Installation Guide and Operation Manual.

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Oxymax COS61/COS61D. Technical Information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

COSMO INSTRUMENTS CO., LTD.

AUTOMATIC HOSE TEST UNIT, TYPE SPU

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Automatic Valve Proving Control

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

AutoChanger Installation & User Guide Issue 2

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

High-performance submersible pressure transmitter For level measurement Model LH-20

GasSense NDIR User Manual

Pressure regulators. Introduction. TR Head. 3 ways body Dival

Transcription:

Fio 2.2 Smart add-on for gas pressure Regulators

Fio 2.2 Classification and Field of Application Fio 2.2 is a modular system that allows to remotely control a pressure reduction station of a natural gas distribution network. The system Fio 2.2 is composed by a battery-operated Electronic Control Unit with 2G modem and antenna including two pressure sensors and one gas temperature sensor. On request the system can be equipped with 2 auxiliary pressure sensors, displacement transducers and a pilot control system for pressure regulators. TE Pu Pd Paux 1 Paux 2 2x Q-Kit 2x Pkit 6x digital Input (2) 1 x BF/HF +1x BF Power Pulse 2x- RS485 Power Pulse 2X - RS 232/485 RTUbox 24Vdc RTUbox 240Vac RTUbox Solar 2

FEATURES Functional features: Ambient temperature: Standard version -20 +60 Protection Rating: IP 65 Power Supply: Display: Non rechargeable battery or rechargeable battery connected with 24V DC, 110-220V AC or Solar power supply modules, to be integrated in RTU by the customer or provided already in pre-wired boxes. 128x464 pixels B & W with green background. Visible area 71x39mm. Keyboard: 24 keys membrane keyboard + Emergency button Remote Communication: GSM / GPRS quad band modem - Bluetooth 2.1-868Mhz RF optional module Local communication: Two RS485 and Bluetooth CPU: Twin Arm Cortex CPU Memory: fflash: 2MB + 2MB (Additional) - RAM: 64KB + 32 KB Electrical connections: Quick spring-cage connection terminal block ATEX, II 2 G Ex ib IIB T3 Gb (Tamb -20 +60 C) Certifications: CEC15ATEX054X Certificate n 15/2020-AET1449 Materials: Container: High resistance plastic material with transparent cover. Material: ABS for container, polycarbonate for transparent cover. NOTA: The indicated materials refer to standard executions. Different materials can be provided upon request. 3 Providing Solutions for Oil and Gas

Fio 2.2 PILOT 201\E\FIO The current range of pilots for the FIO system is now available with a new version, the pilot 201\E\FIO. This new pilot allows to control the downstream pressure through an electric motor positioned on the lower part that will act directly on the setting screw. The movement of the screw will be controlled through an electric motor complete with a gear, without an external power supply but activated directly by FIO, which there is full compatibility with. Features: Full interchangeability with pilot 201/A/2/CS FIO. The outputs of the F.I.O. can indifferently operate the solenoid valves or the electric motor. Retrofitting on the field with standard pilots: is enough to replace the lower part of the pilot, without changing brackets and connecting pipes.. You can order the complete pilot system or just the kit to upgrade it on the field. Does not modify the standard pilot 201/A performances, since the pneumatic part remains unchanged. High resolution, you can control very small pressure variations. It able to set the minimum pressure limit switch. Available for low / medium downstream pressures. Temperature range -20 C-60 C. Fail-freeze function. In case of failure, maintains the last setting pressure. ATEX approved with FIO2.2 Available with shielded cable for FIO2.2 connection, length 3 and 5 mt. 201/A/2/CS 201\E\FIO Fig.1 4

Five functions in a single device The peculiar characteristic of Fio 2.2 is the integration of 5 functions in a single device. [IFM] > Indirect Flow Measurement, differently from traditional flow measurement systems, it realizes the flow measurement in a non-intrusive manner, by means of correlation calculations based on measured pressures and meaningful plug displacement. [OPC] > Outlet Pressure Control, that is the regulator outlet pressure control, made remotely or locally, in agreement with a daily / weekly schedule or to compensate for demand load. [FL] > Flow rate Limitation, flow limitation modifying the outlet pressure to keep the flow below of a configurable threshold; it allows to replace the traditional invasive mechanical systems for limitation, without pressure drops under standard operating conditions. [RM] > Remote-Monitoring of key parameters for safety management of the station (inlet and outlet pressure, safety valve and monitor intervention, filters status check, intrusion, gas leakage). [EUM] > End User Management, that is the interruption of supply to a user in case of emergency or of late payments. Fio 2.2 can be powered by long life Batteries, solar panels or line power (24 volt, 120 volt or 220 volt). When Fio 2.2 is battery-operated, and if the outlet pressure modulation function is not active, control units and communication are both kept in a low consumption state (sleep mode) to increase battery life. When an alarm condition is detected, the control unit wakes up from low power and activates the communication unit to make a call to the remote control center (watchdog function). In any case, the unit periodically exits the low-consumption state to verify for the receipt of any messages. 5 Providing Solutions for Oil and Gas

SCHEMES OF APPLICATION Indirect Flow Measurement [IFM] Knowing the quantity of gas flowing through a regulator station of a gas system allows you to achieve accurate load balancing in your system. Existing flow measurement at stations is achieved by means of meters or orifice plates, requires the modification of the station layout and in some cases the availability of a significant source of power supply (ultrasonic, turbines, etc ) and, in any case, costs are high that the investment sometimes isn t justified. Fig.2 The principle of operation of indirect measurement is based on the assumption that for each model of regulator there is a relationship between the instant flow at standard conditions, the orifice & valve displacement and the values of inlet and outlet pressure. The calculation of flow value is carried out at predetermined intervals of time, with a maximum frequency of 1 time per second (1Hz). The accuracy of indirect flow measurement IFM vary according to the graph Fig.3 is inside the limits highlighted with the lines red, yellow and green depending on the regulator opening. In the graph is reported indicatively the error% of the indirect flow IFM with different regulator opening%. Error % referred to measured value Accuracy class (error vs % regulator opening) % Regulator opening Fig.3 6

Flow Rate Limitation [FL] Fig.4 Flow limitation allows to ensure that you agree to the contractual terms for the amount of gas allocated for the station In respect to the project specifications, and ensuring at same time an adequate level of safety to the system. This function can be used to achieve the balancing between the stations feeding your system. The Flow limitation function is activated only if there is provision for the pressure modulation function and if it s Available the (direct or indirect) flow measurement. When the flow measurement value at reference conditions, calculated by means of indirect flow measurement or derived from a meter or a converter, reaches or exceeds a configurable limit, Fio 2.2 starts to modulate the outlet pressure with the purpose of reducing the load. The pressure reduction happens ensuring a configurable minimumset point value. 7 Providing Solutions for Oil and Gas

Outlet Pressure Control [OPC] Fig.5 To increase or decrease the outlet pressure of a regulator, it is necessary to decrease or increase the motorization force of the pilot. The increase or decrease of motorization can be obtained increasing or reducing gas pressure or the pressure of the air injected inside the spring chamber ( Motorization Pressure ). The calibration spring must be set up to get the minimum set point value of pressure regulator. Changing the pressure set point of a regulator, without the intervention of an operator, is helpful in all those cases in which the pressure in the system is highly variable during the day, due to varying load conditions, to ensure an adequate gas supply to all the users of your system. The goal of reducing gas leaks in a system can be obtained by maintaining the pressure to the minimum possible value when there isn t demand load from the users. The system is able to drive up to 10 lines of regulation, maintaining the specified intervention ΔP between lines The Pressure profiling function carries out an automatic control to change the outlet pressure to a value specific to the period of the day. It is possible to configure up to 7 different pressure set points for each day of the week. The ECU module stores a weekly active schedule and a further future schedule. If flow measurement is available (computed with indirect method or directly detected from a meter or corrector), the Pressure compensation function can be activated as an alternative to Pressure profiling. This function allows to automatically correlate the inlet pressure with the instant flow. The modulation accuracy is better than 1% of the nominal full range pressure value. 8

Multi Drop Modular System FIOBus master-slave Fig.6 Each Fio 2.2 unit is able to control up to 2 lines. If there is the need of controlling more than 2 lines (and up to 10), it is possible to interconnect via bus several Fio 2.2 units. All remote connections, such as RTU, modem, etc., are interfaced jointly with the main Fio 2.2,to who all secondary units are connected. 9 Providing Solutions for Oil and Gas

Digital Inputs Fig.7 Besides pressure and temperature control, the Fio 2.2 system offers there option of using up to 6 digital inputs to monitor some or all of the following on-off states: filters clogging monitor intervention safety valves intervention (slam shut, relief, etc.). intrusion alarm for Entrance gate gas presence detector flood detector flame detector Telecontrollo Remote monitoring [RM] [RM] The remote monitoring of a reducing station is really important for the safety and the network management Fio 2.2 keeps the performance of remote monitoring currently implemented in the devices of the EX- PLORER family. In detail, the control unit, at its maximum expansion, is able to monitor: Inlet and outlet pressure of the station with stability and accuracy better than 0.25% of full range Gas temperature, measured by means of a PT1000 transducer Flow value calculated by means of an meter or volume converter and transmitted by means of a LF or HF pulse emitter 6 digital inputs, the state (ON-OFF) of as many operating conditions, such as clogging of filters, safety valves tripping, monitor regulator takeover, intrusion, etc 10

End-user management [EUM] We offer the feature to remotely disconnect from a system (interruptible). In case of particular condition that could compromise your system, increasing the speed of intervention, to help reduce the operating costs. In addition it can be an alternative to optimize the system when it is necessary to manage random situations. Supply interruption can be activated such as releasing a the slam shut valve or reducing the outlet pressure o a safe minimum value; restoring the operating condition is usually requires an operator or technician find the source of the problem, then acknowledgement can be generated by Fio 2.2 or it can be required that manual restoration of the safety valve be taken care of. The reset can be enabled by means of a specific command from a remote center or on site, inserting a password. Modalità d installazione Fio 2.2 wall mounted by means of an adapter kit provided with the unit DIMENSIONS Fio 2.2 pole mounted by means of a back plate, mounting vertically or horizontally Fio 2.2 application on pipe by means of a back plate, Mounted vertically or horizontally A B C A B C Dimensions (mm) 260 240 117 Pollici 10.24 9.45 4.61 11 Providing Solutions for Oil and Gas

www.fiorentini.com The data are not binding. We reserve the right to make changes without prior notice. CT-s 644-E March 18