DIRECT AND INVERTED PENDULUMS. Model DP & RP. Roctest Limited, All rights reserved.

Similar documents
SOIL SETTLEMENT GAGE. Model SSG. Roctest Limited, All rights reserved.

SOIL SETTLEMENT GAGE Model SSG. Roctest Limited, 2005, All rights reserved.

GROVE MODEL RT58D - 20 TON CAPACITY

In the liquid phase, molecules can flow freely from position to position by sliding over one another. A liquid takes the shape of its container.

In the liquid phase, molecules can flow freely from position. another. A liquid takes the shape of its container. 19.

Float a Big Stick. To investigate how objects float by analyzing forces acting on a floating stick

Operating Instructions Part No

L 13 Fluid Statics [2] More on fluids. How can a steel boat float. A ship can float in a cup of water! Today s weather

Density and Specific Gravity

1. Air is blown through a pipe AB at a rate of 15 litre per minute. The cross-sectional area of broad

Clicker Question: Clicker Question: Clicker Question: Phases of Matter. Phases of Matter and Fluid Mechanics

PUNE TECHTROL PVT LTD. Instruction and Maintenance Manual for Float and Tape Gauge FTG

PHYS:1200 LECTURE 13 FLUIDS (2)

DX2/DXX Operating Instructions

Irrigation &Hydraulics Department lb / ft to kg/lit.

Middle East Technical University Department of Mechanical Engineering ME 305 Fluid Mechanics I Fall 2018 Section 4 (Dr.

Medium Heavy Vehicle Safety and Foundation 1

Operating Instructions Part No

and its weight (in newtons) when located on a planet with an acceleration of gravity equal to 4.0 ft/s 2.

InstrumentationTools.com

Chapter 3: Fluid Statics. 3-1 Pressure 3-2 Fluid Statics 3-3 Buoyancy and Stability 3-4 Rigid-Body Motion

Simple Measurements & Buoyancy Force

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

PHYS 101 Previous Exam Problems

Measurement And Control Appreciation

VACUUM TESTING PRECAST CONCRETE MANHOLES

Matter is made up of particles which are in continual random motion Misconception: Only when a substance is in its liquid or gas state do its

LOAD CHARTS RT540E 85% STABILITY ON OUTRIGGERS 75% STABILITY ON RUBBER

PRESSURE. 7. Fluids 2

Unit 1 Lesson 5 Fluids and Pressure. Copyright Houghton Mifflin Harcourt Publishing Company

Density. Chapters 12-14: Phases of Matter. Example: Density. Conceptual Check. Springs 2/27/12. Mass Density vs. Weight Density

Precision Liquid Settlement Array Manual

Phys101 Lectures Fluids I. Key points: Pressure and Pascal s Principle Buoyancy and Archimedes Principle. Ref: 10-1,2,3,4,5,6,7.

Variable Area Flow Meters

RELIEF CAPACITY CURVES

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes

Pressure transmitters EMP 2

LAB 7. ROTATION. 7.1 Problem. 7.2 Equipment. 7.3 Activities

Before we begin, let us recall some important information about the metric measuring system.

VARIABLE ORIFICE BALANCING VALVE PN 25 TECHNICAL DATA SHEET. Approved by*: Main features:

_ pressure transducers. User Manual

HEATEC TEC-NOTE Publication No Revised

Marine Kit 4 Marine Kit 4 Sail Smooth, Sail Safe

Chapter 15 Fluids. Copyright 2010 Pearson Education, Inc.

Force Sensor DATA HARVEST. (Product No. 3143) Range: ±50 N Display resolution: 0.1 N

SEMMME3-073 Checking that completed assemblies comply with specification

. In an elevator accelerating upward (A) both the elevator accelerating upward (B) the first is equations are valid

Experiment 11: The Ideal Gas Law

3. Moments and Pressure

ANNUAL METEOROLOGICAL MONITORING TOWER INSPECTIONS - MAINTAINING SAFETY AND EXPOSURE TO WIND

Lab 13: Hydrostatic Force Dam It

Instruction Manual Model Borehole Pressure Cell

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Old-Exam.Questions-Ch-14 T072 T071

3 1 PRESSURE. This is illustrated in Fig. 3 3.

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Air Eliminators and Combination Air Eliminators Strainers

Objectives deals with forces applied by fluids at rest or in rigid-body motion.

PRO-50 Instrument Supply Regulator

then the work done is, if the force and the displacement are in opposite directions, then the work done is.

1. For the purposes of this standard, the maximum weight capacity of a boat is:

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

EXPERIMENT 8 Ideal Gas Law: Molecular Weight of a Vapor

Rig Math. Page 1.

The Application of Temperature and/or Pressure Correction Factors in Gas Measurement

How to specify a product. Process Sensors and Mechanical Instruments

PHYSICS 206a HOMEWORK #12 SOLUTIONS

Item 404 Driving Piling

LAB 13: FLUIDS OBJECTIVES

Coriolis Mass Flow Meter

Dry Plant Measurement Information

Quiz name: Chapter 13 Test Review - Fluids

The most common terms rating air flow capacity are ICFM, FAD, ANR, SCFM or nl/min

DICTATOR Spring Rope Pulleys for the Closing of Sliding Doors

BUOYANCY, FLOATATION AND STABILITY

LOAD CHARTS RT890E METRIC DIN / ISO / 75%

Buoyancy and the Density of Liquids (approx. 2 h) (11/24/15)

USER S MANUAL. Model TES-SM-30V

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

SASK-A-POLE OWNERS AND USERS MANUAL

Safe hydraulics for hydroforming presses. more finished product to be created from less raw material.

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President

Level MEASUREMENT 1/2016

TOP:001.3 U.S. Fish and Wildlife Service TECHNICAL OPERATING PROCEDURE

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

G.C.E (A/L) Examination March In collaboration with

GRADE 7: Physical processes 1. UNIT 7P.1 8 hours. Measurement and density. Resources. About this unit. Previous learning.

Vibration isolation system 1VIS10W. User manual

Density Determination Kit Instruction Manual

Notes Chapter 3. Buoyancy

Vibrating Wire Load Cell (3, 4, 5 And 6 Gauge Cells) User Manual

SIZING THE EXTROL DIAPHRAGM-TYPE HYDRO-PNEUMATIC TANK

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

3. A fluid is forced through a pipe of changing cross section as shown. In which section would the pressure of the fluid be a minimum?

VW Liquid Settlement System VWLSS-200

EEF. Fatigue Testing Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Engineering and Technical Teaching Equipment

Counter Weight Lifting Gantry Cylinder Operation INDIA CKE2500, CKE2500-2

Product Manual. Cyl-Tel and Tank-Tel Liquid Level Gauges. Designed and Built by: Chart Inc th Street NW New Prague, MN USA (800)

Transcription:

INSTRUCTION MANUAL DIRECT AND INVERTED PENDULUMS Model DP & RP Roctest Limited, 2006. All rights reserved. This product should be installed and operated only by qualified personnel. Its misuse is potentially dangerous. The Company makes no warranty as to the information furnished in this manual and assumes no liability for damages resulting from the installation or use of this product. The information herein is subject to change without notification. Tel.: 1.450.465.1113 1.877.ROCTEST (Canada, USA) 33.1.64.06.40.80 (France) 41.91.610.1800 (Switzerland) www.roctest.com E10091-060901

TABLE OF CONTENTS 1 APPLICATIONS... 1 2 PRODUCTS... 1 2.1 General descriptions... 1 2.2 Operation principle... 1 3 INSTALLATION PROCEDURES... 2 3.1 Direct pendulum... 2 3.2 Inverted pendulum... 4 4 READING PROCEDURES... 6 4.1 Manual readings... 6 4.1.1 Sighting reading table model 76... 6 4.1.2 Mechanical reading table model RT-IP50... 6 4.1.3 Optical coordinoscope model MVR... 6 4.2 Remote electrical readings... 6 4.2.1 Model RxTx electrical remote reading station... 6 4.2.2 Model PI-30 induction remote reading station... 6 5 MAINTENANCE... 7 6 MISCELLANEOUS... 7 6.1 Environmental factors... 7 6.2 Conversion factors... 8 i

Note: This instruction manual covers general principals as to the installation of pendulums. Different parts and setups may be selected which may differ from those presented herein. Therefore, this instruction manual should be read accordingly. 1 APPLICATIONS Direct and inverted pendulums are designed to accurately measure the relative internal horizontal displacement of points along a true vertical line. The pendulum is used in the following applications: - monitoring of movements within dams, dam foundations, nuclear power stations, viaducts and bridge piers - monitoring of structural and foundation movements in buildings - reference for surveying monitoring method. The instrument has especially significant place in the field of dam monitoring to detect sliding or overturning of blocks. 2 PRODUCTS 2.1 GENERAL DESCRIPTIONS The direct pendulum is comprised of a wire suspended from the upper point and a reading station fixed to the structure at the lower point. The wire is tensioned by a suspended weight submerged in a damper tank. The fixed end of the inverted pendulum is grouted at the lower point of the system. The wire is tensioned vertically by a float. When anchored in a fixed point in foundation, it measures absolute displacement of points along the wire. 2.2 OPERATION PRINCIPLE The pendulum wire acts as a plumb wire, showing the local verticality. Movements of the structure between the free wire end and the anchor are detected by measuring the variations of the wire position. Page 1

3 INSTALLATION PROCEDURES The following rules should be kept in mind during a pendulum installation. 1. In general, the maximum length of a pendulum shall not exceed 60 m. If the height of the structure to be monitored is superior to this value, it is advised install several pendulums in series. 2. While defining project, one must take into consideration overall dimension of the pendulum parts. 3. The reading table shall be oriented in such a manner to follow the greatest expected displacement. 4. The verticality of the well or borehole shall be sufficient to permit the free movement of the vertical wire in all directions. 5. The complete installation must be protected from the winds, air currents and water fall which may impair the stability of the vertical wire. 3.1 DIRECT PENDULUM Use the following procedure to install an inverted pendulum. 1. Install the wire anchoring device. 2. With the use of a plumb-line passing through the V-notch of the wire centering bracket, adjust the centering bracket in such a manner that the wire will pass in the center of the cylindrical hole (well or borehole). If the direction of maximum amplitude is approximately known, the wire can be offset by half an amplitude, in the opposite direction of the expected displacement. 3. Install and adjust brackets in relation to the plumb-line wire. 4. Install and adjust the reading table (please refer to the instruction manual of the latter for installation details). 5. Install the wire and the bottom weight. Take into account that elastic elongation of the wire is approximately 2 mm per meter. 6. Adjust the bottom tank (used to damp oscillation of the wire) in such a way that the bottom weight does not touch the tank walls or bottom. Fill tank with oil after stabilization of the weight position. Page 2

Figure 1: Typical installation of a direct pendulum with a RxTx remote reading station Page 3

3.2 INVERTED PENDULUM Use the following procedure to install an inverted pendulum. 1. Install the brackets of the tank and the readout equipment. 2. Install the tank and the readout equipment over the brackets. Leave some play to be able to adjust them later. Install the float and its tensioning rod. 3. Attach the wire to the weight and lower it into the borehole. Secure the free end of the wire during the operation. 4. Attach the free wire end to the tensioning rod of the tank. 5. Using a pen or a piece of tape, mark a position on the cable to follow its vertical movement during tank filling. 6. Fill the tank with oil until the weight is lifted off the bottom of the borehole. The whole system (float, wire and weight) should be impeded by anything. If necessary, adjust the position of the tank and the readout equipment. 7. Fill the borehole with a cement grout up to the top of the weight. 8. Once the grout is set, adjust definitively the positions of the tank and the readout equipment. If necessary, add some oil into the tank to completely immerse the float without allowing it to enter in contact with walls, bottom or cover. Page 4

Figure 2: Typical installation of an inverted pendulum with a RxTx remote reading station Page 5

4 READING PROCEDURES The monitoring of the wire position for both direct and indirect pendulums can be done manually and/or electrically with a remote readout unit. The method of reading depends upon the concept of monitoring, the expected values of movements, and the accuracy required. This instruction manual should be read in conjunction with those related to these reading devices. 4.1 MANUAL READINGS 4.1.1 SIGHTING READING TABLE MODEL 76 To take a reading with a mechanical reading table the operator aligns the cursors on the left and right scales with their respective sights and with the pendulum wire. The positions of the cursors are read directly off the scale and the cursor vernier. The readings are converted to wire displacement values using the charts provided with each reading station. 4.1.2 MECHANICAL READING TABLE MODEL RT-IP50 Readings are taken by means of a digital micrometer. Four reference pins are used to section respectively the depth micrometer in the X and Y axes. Measurements are made by bringing the depth micrometer anvil in contact with the pendulum wire, in reference to the fixed pin. 4.1.3 OPTICAL COORDINOSCOPE MODEL MVR The setup consists of a reference base permanently installed at the reading point. The coordinoscope is then installed on its reference section respectively at X and Y axes on the base frame. Measurements are taken by focusing or aiming the lens at the pendulum wire and by reading the current lateral displacement on the vernier. 4.2 REMOTE ELECTRICAL READINGS 4.2.1 MODEL RXTX ELECTRICAL REMOTE READING STATION Please refer to its specific instruction manual. 4.2.2 MODEL PI-30 INDUCTION REMOTE READING STATION Please refer to specific instruction manual. Page 6

5 MAINTENANCE Pendulums do not require much in term of routine maintenance. The user should always make sure that: - the wire is always free to move i.e. that it is not stuck by a debris; - the wire is always protected against wind; - the liquid level in the tank is appropriate; - and each part of the whole system remains well anchored to the structure. 6 MISCELLANEOUS 6.1 ENVIRONMENTAL FACTORS Since the purpose of pendulum installation is to monitor site conditions, factors which may affect these conditions should always be observed and recorded. Seemingly minor effects may have a real influence on the behaviour of the structure being monitored and may give an early indication of potential problems. Some of these factors include, but are not limited to: blasting, rainfall, tidal levels, excavation and fill levels and sequences, traffic, temperature changes, changes in personnel, nearby construction activities, seasonal changes, etc. Page 7

6.2 CONVERSION FACTORS To Convert From To Multiply By LENGTH AREA VOLUME MASS FORCE PRESSURE AND STRESS TEMPERATURE at 4 C Microns Millimetres Meters Square millimetres Square meters Cubic centimetres Cubic meters Litres Litres Kilograms Kilograms Kilograms Newtons Newtons Newtons Kilopascals Bars Inches head of water Inches head of Hg Pascal Kilopascals Kilopascals Kilopascals Inches Inches Feet Square inches Square feet Cubic inches Cubic feet U.S. gallon Can Br gallon Pounds Short tons Long tons Pounds-force Kilograms-force Kips Psi Psi Psi Psi Newton / square meter Atmospheres Bars Meters head of water Temp. in F = (1.8 x Temp. in C) + 32 Temp. in C = (Temp. in F 32) / 1.8 Table 1: Conversion factors 3.94E-05 0.0394 3.2808 0.0016 10.7643 0.06101 35.3357 0.26420 0.21997 2.20459 0.00110 0.00098 0.22482 0.10197 0.00023 0.14503 14.4928 0.03606 0.49116 1 0.00987 0.01 0.10197 E6TabConv-990505 Page 8