Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President

Similar documents
Sontek RiverSurveyor Test Plan Prepared by David S. Mueller, OSW February 20, 2004

Precision Liquid Settlement Array Manual

BUYER S GUIDE AQUAlogger 530WTD

HOBO U20L Water Level Logger (U20L-0x) Manual

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

HOBO MX Water Level Logger (MX2001-0x) Manual

MOTUS Wave Buoys. Powered By the Aanderaa MOTUS Directional Wave Sensor

Viva TPS. TS11/15 Total Stations Check and Adjust Procedure. October Summary

Pneumatic high-pressure controller Model CPC7000

Overview. 2 Module 13: Advanced Data Processing

TR Electronic Pressure Regulator. User s Manual

Methods for Measuring Groundwater Elevation and Vacuum Pressure During Soil Vapor Extraction

Series Environmental Chambers

Electronic Volume Correctors

HOBO U20 Water Level Logger (U x and U x-Ti) Manual

AN31E Application Note

DST Host User Manual

S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

BUYER S GUIDE AQUAlogger 520

AN INSTRUMENTATION SYSTEM TO MEASURE IN-SITU HYDRODYNAMICS DURING BARRIER ISLAND OVERWASH AND INUNDATION

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

Onset Computer Corporation Inside this package: HOBO U20 Water Level Logger Calibration Certificate

Vibration isolation system 1VIS10W. User manual

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Pneumatic high-pressure controller Model CPC7000

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

DX2/DXX Operating Instructions

SHIMADZU LC-10/20 PUMP

Tripod Setup Guide (M-TPx)

High Ping Rate Profile Water Mode 12

Heavy Duty Dissolved Oxygen Meter

Side-of-Pole Mount for 1 Module (SPM1) For Module Type C

Field Manual. Simple by Design

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

HumiSys HF High Flow RH Generator

Metham Aviation Design Limited, Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0)

UsER manual for Watersens ph -REDOX

Installation Guide RHT-380. This Manual Must Be Read Before Operating The Equipment CUSTOMER COPY

Observations of Near-Bottom Currents with Low-Cost SeaHorse Tilt Current Meters

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

AANDERAA. Measuring: Current Speed Current Direction Temperature

Gripping rotary modules

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

D-OptoLogger Dissolved Oxygen Logger Operation Manual

HOBO MX Water Level Logger (MX2001-0x) Manual

MEASUREMENT COMMUNICATION INSIGHT

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Specifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS)

BGA244 Binary Gas Analyzer

EFFECTIVENESS OF FLOATING WAVE ATTENUATORS FOR RESTORING AND PROTECTING COASTAL MARSH

Observations of Near-Bottom Currents with Low-Cost SeaHorse Tilt Current Meters

HYDRAULICS. H89.8D - Hydraulic Bench

EPP4 Pressure Regulator Basic G 1/4"

Expert Hydrostatic Level Transmitters

Low Wind High Yields Series

AMS 6915 Board mount pressure sensor with digital output (I²C)

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Available online at ScienceDirect. Energy Procedia 53 (2014 )

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

Design Based Anchoring 2009 FORD F-150

RESOLUTION MSC.94(72) (adopted on 22 May 2000) PERFORMANCE STANDARDS FOR NIGHT VISION EQUIPMENT FOR HIGH-SPEED CRAFT (HSC)

Description. Measuring Device 3760XBI USP. Balancing

Side-of-Pole Mount for 1 Modules (SPM1) For Module Types E, F, G, & H ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation

WeatherStation Monitoring for Industrial marine Applications

ZIPP VUMAQUAD INSTALLATION INSTRUCTIONS

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Nortek Technical Note No.: TN-021. Chesapeake Bay AWAC Evaluation

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

TRI-POD SETUP. Guidelines for Typical Field Setup. Site Selection

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

Dynamic Positioning Control Augmentation for Jack-up Vessels

E-trike Li Assembly Guide

AMS 6916 Board mount pressure sensor with ratiometric analog output

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

TRIAXYS Acoustic Doppler Current Profiler Comparison Study

Float operated valve TYPE (SWDS)

Rudder Kit Assembly Instructions for Quest 13

Page 1 of 1 04/19/13 SBR

Technical Information Conducal CLY421

Water Samplers, Water Sampling with Internal Recording, Cabling, and Deployment

DTG - LCD Digital Temperature Gauge USER MANUAL

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

Vertical Wind Energy Engineering Design and Evaluation of a Twisted Savonius Wind Turbine

INTRODUCTION TO NETWORK WIND 3 MOUNTING THE UNIT 14 SELECTING THE DISPLAY MODE 5 ABBREVIATIONS AND DEFINITIONS 17

Model 6812C Dual Lane Scoreboard Owner s Manual

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

Installation and Training Manual

Measuring wind speed and direction

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

Microfluidic Demonstration

RADROVER REAR RACK INSTALLATION MANUAL

PMI ADVANCED AUTOMATED HYDRAULIC PRESSURE LEAK TESTER APCS-H-60K. Not just Products... Solutions!

CONSTRUCTION OF LNG RECEIVING TERMINAL ON THE SAINT LAWRENCE TIDAL CURRENT CONDITIONS IN THE LEVIS AREA

uemis CONNECT: Synchronisation of the SDA with myuemis

Conventional Ship Testing

Marine 6-Boat Free-Standing Racks SKU: Updated November 2011

Naval Postgraduate School, Operational Oceanography and Meteorology. Since inputs from UDAS are continuously used in projects at the Naval

Kestrel HVK Gun Loader Sofware

Transcription:

Lowell Instruments Application Note #TCMA Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President 1 Introduction The TCM-1 Tilt Current Meter (TCM) is typically mounted in a vertical orientation where the meter is anchored on (or near) the sea bed and the meter floats above the anchor. But for some deployments, it is advantageous to measure water velocity near the top of the water column in an inverted orientation with the meter hanging below the attachment point. This application note describes how to use the TCM in an inverted orientation and includes recommendations on site selection, data logger configuration, anchoring techniques and data post-processing. AN #1, Rev A, March 2016 2016 Lowell Instruments, LLC

2 Requirements The following items are required to use the TCM-1 in an inverted orientation: TCM-1 Current Meter consisting of: o MAT-1 Data Logger o 46 cm (18 ) float o Nose cone with lanyard o 1 x Ballast Washer TCM-1 Inversion Kit consisting of: o 2 x Silicon Bronze TCM Ballast Washer Range Weights o 1 x 5/16-18 by 1-1/4 inch long silicon bronze hex head cap screw Windows PC with MAT Logger Commander Software V1.22b or higher installed (not shown) Three-washer tilt-to-speed inverted calibration curve for the TCM-1 (preliminary release, installed separately from MAT Logger Commander Software, not shown) USB A to micro-b cable (not shown) 3 TCM Theory Tilt Current Meters operate based on the drag-tilt principle. The meter is tethered to a fixed point and the instrument floats (or sinks) vertically when there is no flow and tilts as water velocity increases. The direction of flow is determined by the direction of tilt. Modern TCMs use three-axis accelerometers to determine the angle of tilt and 3-axis magnetometers to determine the direction of tilt. An important assumption is that the tilt measurement is determined in quasi-static conditions (i.e. the meter is not accelerating). TCMs typically oscillate between 0.25 and 0.5 Hz due to vortex shedding. This relatively low-frequency oscillation is averaged out of the raw data by sampling above the Nyquist frequency (twice the oscillation frequency). Likewise, the effect of swells can be filtered by increasing the averaging period to at least double the swell period. But movement and vibration of the anchor point, especially above the sampling frequency, adds error that is difficult to eliminate. Therefore, care must be taken when selecting a site for a top-mounted TCM to reduce or eliminate motion/oscillations/vibrations at the anchor point. 4 Site Selection There are several factors that should be considered when selecting a site for a TCM. Water Velocity: The TCM-1 is recommended for sites with water speeds of 0-80 cm/s. The meter saturates at 120 cm/s. Accuracy between 80 and 120 cm/s is not specified. Application Note #TCMA, March 2016 Page 2 of 10

Waves: The TCM is designed for sites with low wave energy. Avoid sites with breaking waves as the rapid acceleration of the TCM will break the quasi-static assumption and will add error to the measurements. Waves are even more of a concern for meters deployed near the surface. Even when oversampling and filtering are used, the meter will be more accurate in relatively protected environments, such as protected harbors and coves, or deployed at least twice the wave height below the surface. Anchor Point: The ideal anchor point is a fixed structure because it will eliminate the possibility of movement of the anchor point. But fixed structures are often not available, so the next best attachment point is a large floating dock, fish pen or other anchored floating structure. Small floats and buoys should be avoided because they are much more likely to move/oscillate/sway due to wind, waves and currents. 5 Meter Assembly To assemble the TCM-1, screw the MAT-1 Data Logger into the threaded end of the float until tight. A firm grip is sufficient. Attach the three ballast washers to the end of the float using the bronze cap screw. Do not overtighten. Use a firm grip and screw the logger all the way onto the threaded bronze stud until tight. Use 1/2 inch wrench. Do not overtighten. Application Note #TCMA, March 2016 Page 3 of 10

6 Meter Configuration The brains of the TCM-1 is the MAT-1 data logger. The MAT-1 has the ability to use a burst mode recording interval (see Figure 1). This note highlights the three burst mode parameters that are stored in the MAT.cfg file and are used to configure the TCM for a range of environments. (For complete operating instructions see the MAT-1 & TCM-x Universal User Guide.) Burst Logging allows the logger to alternate between rapid sampling and sleep mode. Burst Logging allows for accurate measurements while conserving battery life. For example, a typical configuration would have the meter wake up every minute, record at 8 Hz for 15 seconds and then sleep for 45 seconds. The result of this setup would be 120 samples recorded every minute. After the deployment is complete, the 120 samples will be post processed into 1 minute velocity records. Thus, in this example, each velocity measurement is an average of 120 samples taken over a 15 second period. Figure 1: Typical settings for a TCM deployment. The burst mode parameters are circled. Burst Interval: This parameter sets the measurement interval. Each current measurement is comprised of a series (or a burst ) of measurements. The Burst Interval is the length of time between the start of Application Note #TCMA, March 2016 Page 4 of 10

any two intervals. Typically, the Burst Interval is set between 1 and 5 minutes, providing high temporal resolution data that can be post-processed into longer intervals if desired. Burst Rate: This parameter sets the rate at which samples are recorded during the burst. Even in ideal conditions, the meter oscillates with a period of 2-4 seconds. Thus to record the average tilt and bearing more than one measurement is required. The minimum recommended burst rate is 4 Hz, with 8 Hz typical. 16 Hz is recommended for more energetic environments with waves. Burst Duration: This parameter sets the length of time that the accelerometer and magnetometer sample at the burst rate. To obtain an accurate average, the burst duration should be at least twice the period of any oscillation in the system. As previously mentioned, the TCM oscillates with a period of 2-4 seconds. The recommended minimum burst duration is 10 seconds, with 15 seconds more typical. If there is a dominant swell, the burst duration should be increased to 30-60 seconds depending on the swell period. Note that all three of these settings impact battery life. The MAT-1 will run for many months with typical settings before battery failure (memory is never the limiting factor). However, running continuously at the maximum rate will reduce the battery life to as little as 6 weeks. See the Universal User Guide for more information on battery life. Three sets of recommended settings are shown in the table 1 below. Table 1: Recommended settings for TCM-1 deployments in three typical environments. Configuration Burst Interval (s) Burst Rate (Hz) Burst Duration (s) Notes Typical 60 8 15 Suitable for most environments with limited swells. Battery life: 12-14 months Swells 120 8 45 Increased burst duration for filtering longperiod swells. Battery life 10-12 months. Waves & Turbulence 60 16 30 Increased burst rate and duration for filtering moderate swells and wave induced turbulence. Battery life 5-6 months. Application Note #TCMA, March 2016 Page 5 of 10

7 Mounting the Meter The TCM is supplied with a flexible lanyard for mounting to an anchor or other hard point. There are many ways to mount the meter but there are several factors that will improve the quality and accuracy of the data. Mount the lanyard in such a way that the lanyard length does not change based on the direction of pull. This is typically done by drilling a hole through the anchor and knotting the lanyard on the back side (see Figures 2A, 2B and 3A, 3B, 3C). Limit the lanyard to 2 cm (3/4 inch) or less (see Figure 2B). The lanyard should only be long enough to allow for full range of motion. Long lanyards may result in the meter oscillating, bumping into the anchor or even moving into the wake shadow of the attachment point. If the TCM will be mounted on a floating dock, mount the meter towards the middle of dock to minimize motion from waves and dock loading (Figure 4). 2 cm Max Figure 2A & 2B: Recommended mounting method using dimensional lumber. A hole is drilled through the end of the board with a second hole for the knot (left). The lanyard length is limited to less than 2 cm (right). Application Note #TCMA, March 2016 Page 6 of 10

Best Good Figure 3A (top left): The recommended mounting method for an aluminum bracket is to drill through the bracket, deburr the hole and knot on the back side. Figure 3 B (top right): If drilling through is not an option, tie the lanyard short and tight against the mounting point. Figure 3 C (bottom left): Avoid loose knots that can get fouled and may pull asymmetrically when the current changes direction. Not Recommended Application Note #TCMA, March 2016 Page 7 of 10

Ensure TCM is mounted to the float securely and the entire TCM will be continuously submerged for all conditions of waves and float loading. Position the TCM towards the middle of the float to minimize end motion. No underwater obstructions. Figure 4: Suggested mounting on a floating dock. Meter is free from obstructions, fully submerged and away from the more lively ends of the dock. Application Note #TCMA, March 2016 Page 8 of 10

8 Data Post Processing Data conversion for the inverted logger is very similar to conversion of binary data from a bottom mounted TCM. The only difference is that a different calibration curve will be selected for the inverted configuration. NOTE: At the time of publication, the inverted three ballast washer curve has not been added to the current version of MAT Logger Commander Software (V 1.22b). Therefore the TCM curve installation must be performed manually. Check with your distributor or contact support@lowellinstruments.com for a copy of the tilt-to-speed curves and installation instructions. Begin by stopping the meter and copying the.lid file to your local drive. Then switch to the Convert Files screen in MAT Logger Commander and use the settings as shown in Figure 5 (below). A C D E F B G Figure 5: The recommended settings for post-processing a TCM.lid data file are shown. Select an output type of Current (A), with averaging enabled (B). Use a standard tilt-to-speed curve (C) with model of TCM-1 (D) and three ballast washers (E) then select Salt or Fresh depending on the water type at the deployment site (F). Finally select Convert File (G) and navigate to the location on your local drive where the.lid file was saved. Application Note #TCMA, March 2016 Page 9 of 10

9 Additional Information Lowell Instruments has made a good faith effort to make sure that the information in this application note is accurate and complete. However we are not perfect and this document may contain errors. We also reserve the right to change the software, hardware and instructions at any time and without notice. Please contact your local distributor for support or check www.lowellinstruments.com for the most upto-date documentation including software, manuals, FAQs, firmware updates, and application notes. You may contact us at support@lowellinstruments.com or (US) 508-444-2616. Our physical address is: Lowell Instruments, LLC 33 Cameron Rd. North Falmouth, MA 02556 USA Application Note #TCMA, March 2016 Page 10 of 10