AKTA pure 25 New Owner s Intro

Similar documents
AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:

AKTA 3D SOP. Click on the System Control tab. This screen has 4 windows.

AKTA MC SOP Page 1 9/27/04 AKTA METAL CHELATING SOP

Using the Akta Prime plus October 22, 2012

SOP: Cation Exchange Chromatography of t-pa using AKTA Pure system

SOP: Anion Exchange Chromatography of Green Fluorescent Protein (GFP) using the AKTA Pure system

SOP: Lysine Affinity Chromatography of t-pa on the ÄKTApure Chromatography System

Equipment SOP: Operation of ÄKTA pure Chromatography System

SOP: Buck Scientific BLC-20P HPLC Operation

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Quantitative Analysis of Hydrocarbons by Gas Chromatography

5890II GC Standard Operating Procedure 9/2/2005

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

ÄKTAprime. User Manual

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

Microfluidic Demonstration

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Armfield Distillation Column Operation Guidelines

GE Healthcare. ÄKTAprime plus. Operating Instructions. Original instructions

Peak Biotech - Company & Product Presentation

The instrument will process the samples one by one till all the samples have been cleaned up.

Setting a New Standard in Flash Chromatography Performance

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

Automated Liquid Handling Station

Standard Operational Procedure for Capillary Electrophoresis

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

Calibration of a GC955

SOP for use of the SX19 Stopped-Flow Instrument

FROG-4000 TM Chemical Analysis System

System Overview. TCD Detector temperature setpoint Regulator

Agilent 1100 Series Analytical and Preparative Scale Fraction Collectors. User s Guide

SHIMADZU LC-10/20 PUMP

FROG-4000 TM Chemical Analysis System

FROG-5000TM Chemical Analysis System User s Manual

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300

6800 Maintenance Instruction System Flush Procedure

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

Prep LC Training Manual S.V.

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

GCMSD-Headspace Analysis SOP

RM-80 respiration monitor

Prep LC Training Manual

1.2 Example 1: A simple hydraulic system

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Appendix: Simplified Instructions for Operating the HP 5890 GC/FID and Air Sampling Systems

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

Chapter 14 Coal Boiler Flue Gas Scrubber II

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

KIV-SACS Safe automatic calibration system:

6900 Maintenance Instruction System Flush

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

MODEL 2128 FRACTION COLLECTOR

GradiFrac. User Manual Edition AF

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

AutoTrace SPE Workstation User s Manual

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

UltiMate 3000 Viper Capillary Kits for Intelligent LC (LCi) System Solutions

Figure 1: Plug in ion inlet of mass spec

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

SOLUBILITY OF A SOLID IN WATER

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Valve INV-907. Instructions. 1 Introduction. 2 Installation. Safety. Unpacking. Installing the valve

SS32L Dissolved O 2 Probe

16. Studio ScaleChem Calculations

Recovery collection complete sample recovery in preparative HPLC

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

HOW TO SETUP ROUND ROBIN IN DARTS FOR WINDOWS

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Video Notes. LC Troubleshooting Series Retention Time Shifts

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Instrumental operation: ICS 3000

Operation of the Perkin Elmer TGA-GC/MS

International Journal of Generic Drugs ANALYTICAL METHOD PROCEDURES THIS SOP IS 'SWITCHED : OFF : ON'

operator s manual plus system system nanolc Operator s Manual Revision A1

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Troubleshooting. Select the Table of Contents here Rheodyne All rights reserved

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

Liquid Handling Application Designer V2.0. Software Manual P/N M5200R0

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

Chapter 7 Single Point Calculations

TESLAGON. ShotHelper Manual. How to install and use the Program. Version /30/2014

Observations Possible Causes Recommended Actions. Turquoise color

Prep 15 SFC System System Guide / Revision A Copyright Waters Corporation 2014 All rights reserved

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

[MYLAPS INTEGRATION]

LC, RSLC, Bio RS and Dual Gradient Systems

UWPR. LC-MS setup. Before you connect your trap and column. Connecting your trap and column

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

The information contained in this document is subject to change without notice.

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

SOLUBILITY OF A SOLID IN WATER

Transcription:

AKTA pure 25 New Owner s Intro The exercise below will give a quick demonstration of how easy and intuitive the AKTA pure 25 will be for you in demonstrating downstream processing to your students. Steps include: Opening the Unicorn software windows for manual control and programmable features Purging/priming pumps and tubing Loading a sample loop prior to injection on the column Editing a method Running a method For this intro, a length of (restricted flow) tubing will be used in place of the column. You will also need filtered degassed deionized water or buffers, and a solution of 0.1% acetone in water (the sample). Definitions: Manual Load position of the injection valve that allows the user to load the sample loop with sample by depressing the plunger of inserted syringe full of sample (commonly referred to as injecting, but in this context, injection has a different meaning; see below). Injection position of the injection valve that puts the sample loop in the flow path of mobile phase between the pumps and the column, such that the loaded sample flows from the sample loop onto/through the column and downstream path. The amount of sample that is injected onto the column can be specified in the method by editing prior to starting a chromatographic procedure.

Take a moment to identify the labeled components of the system: Buffer Tray UV Detector, 280 nm Column 0.5 ml Sample Loop & Injection Port Run/Resume Button Pause Button Conductivity Detector Pumps A1, A2, B1, B2

What to do with your new AKTA pure 25. Great news you have a brand new AKTApure automated chromatography instrument in your biomanufacturing lab!! Here is a brief introduction that will get you comfortable using most of the important functions of the instrument and allow you to successfully separate proteins in short order. First the most important rule: never let air into the flow path. Running the pumps while dry will almost certainly damage them. Air space in the column can adversely affect resolution. Air in the us detector may result in uninterpretable A280 traces on the chromatogram. As with any liquid chromatography system air or gas in the system is the enemy, so make sure each of the inlet tubes (which deliver buffer to each of the pumps) is securely resting on the bottom of a buffer container (flask, bottle, etc). 1. Power up. Now you re ready to turn on the instrument (switch is on the right side, toward the rear), and the computer, if it s not already on. 2. Boot up Unicorn and get to know the manual System Controls. Open the Unicorn software windows: System Control, Method Editor, Evaluation, and Administration. Bring the System Control window to the forefront. If it is blank, go to the menu System and select System Connect. Place a check by the name of the instrument and click OK. You should now see the schematic of the flow path across the bottom of the screen, as shown here: Now, if you click on each component you will see functions or parameters that you can change manually (via the software). For example, clicking the Inlets depicted (on the left side) allows you to switch the A inlet line and pumps between A1 and A2. Similarly you can switch between B1 and B2. If the system is equipped with a ph detector, it will be shown between the Cond (conductivity) and Outlet positions. Click it and select the option to take it out of the flow path.

Starting with B1, attach a 10 ml syringe to the pump priming fitting and open the valve one full turn or more until you are easily able to withdraw 10 ml of liquid, which will insure the line is full of liquid and any bubbles are out of the line. Repeat these steps to prime every pump. Note that you will need to use the System Control window to manually switch A1 to A2 and B1 to B2. Clicking either of the depicted Pumps brings up a very useful menu that allows you to set the flow rate and buffer mix (expressed at %B), as well as quickly flushing the pumps and flow path up to the injection valve. Give it a try now. Use the mouse cursor to move the sliders then click the Set button to enter the new settings. CAUTION [Changes take effect immediately upon clicking Set; if a column is installed and the flow rate is high enough, pressure will quickly rise, possibly damaging the column- so be careful here. This is less of an issue when running a programmed method, which will have pressure limits set to protect the column.] 3. Wash the pumps. After confirming that you have enough mobile phase (i.e. buffer, water, cleaning solution or storage solution) in each reservoir, open the Pump manual control menu. Pumps should be washed in the order B2, B1, A2 and A1. Select B2 from the dropdown menu in the Pump wash area of the dialog box, then choose the Wash Pump B option. You will hear the injection valve reposition, sending liquid to waste, and the exhilarating sound of the pump working at high speed. This will quickly fill the pump and flow path up to the injection valve, then eluent will go to waste. The wash step stops automatically after one minute. (This operation will not increase pressure on the column, if installed). Repeat with pump B1, A2 and A1. What you have just done is the same procedure used to change buffers between operations, e.g. from storage in 20% EtOH to water to buffer for a chromatographic separation, or from chromatography buffer to CIP solutions for clean-in-place, CIP to water to EtOH for storage, etc). 4. Equilibrate the column in start buffer. In the manual control panel for the pumps, move the slider to a flow rate of 1 ml/min and click Set flow rate. Pump A will begin to move the

mobile phase at that rate through the injection valve, the column, detectors (uv, conductivity and/or ph) and on to the waste receptacle (or fraction collector if specified). After about 5 column volumes (CV), stop the flow, then end the run by clicking the stop icon (a solid square) near the top of the window. 5. Load the Sample Loop. The default position for the Injection Valve is called Manual Load, in which the mobile phase flows from the pumps through the valve and then to the column and detectors. The sample loop is isolated from the flow path. It s good practice to rinse and fill the sample loop with start buffer prior to manually loading it with sample. To do so, fill a one ml syringe with start buffer (taking care to eliminate air bubbles) and attach it to the Luer lock fitting on the injection valve. Depress the plunger to force liquid into and through the loop (stopping before any air near the plunger can enter the sample loop). Excess liquid will go to the waste receptacle. Now repeat the process but fill the syringe with sample (0.1% acetone), leaving the syringe attached to the fitting (to prevent siphoning of sample from the loop). 6. Select, Edit and Run a Method. Select: In the Unicorn software, bring the Method Editor to the forefront. Under File, Open a method of your choice, for example pretend to have installed a 1 ml ion exchange column; select a pre-programmed method for anion or cation exchange. Edit: When the method opens, you will see each of the steps in the method (general settings, equilibration, sample injection, column wash, elution, re-equilibration and perhaps more). Clicking on any of the steps (called Phases) will result in the display of those parameters in the right pane. The Method Settings allows one to choose the appropriate column from the myriad available from GE, or to input custom column dimensions and characteristics. For this exercise, select a one ml ion exchange column. You will see the recommended settings for back pressure limit and flow rate. Here you may also indicate which pumps will be in use (A1, B1 are defaults), the measurement used in each setting (ml, min, or CV column volumes) and which detectors are to be employed. For each phase you will be able to designate the proper pump, % B in the eluent, override the flow rate, and set fraction collection details. Set the fraction collection ( Output ) to waste for this demonstration. Changing the settings in one phase does not effect other phases, so you will need to set the output in each phase. The elution phase will probably include a salt gradient; you may choose linear or step, and the initial and ending %B. Multiple step elution programs are also available. After making the desired changes, choose Save As in the File menu, then rename the program and save it. Run: Return to the System Control window. Under the File menu, choose Open, then double click the name of the method you just saved. The run will begin immediately, unless there is something amiss, e.g. the absence of tubes in the fraction collector, or the fraction collector is not in the ready position (which may not appear until the phase is initiated that calls for collection of fractions). You can monitor the progress of the run in the System Control window. There should be an absorbance peak evident when the acetone sample passes through the uv detector. 7. Return to Storage. Upon completion, the system should be washed through with water, then 20% EtOH if long term storage (one week or longer) is desired. If you ve run this demo with water, you can stop here, for short term storage. Repeat the initial pump wash step to change over to 20% EtOH, then run the pumps at 50%B for about 5 min at 5 ml/min. Make sure there is a large excess of 20% EtOH prior to starting.

8. Open the Evaluation window and the Results Navigator. The most recent chromatogram (yours) will be at the bottom of the list. Double click it to open. You can print it, or choose to save it as a pdf. For more information, please see the library of documentation on the GE Life Sciences website.

The one page version: Quick steps to acquaint you with the AKTA pure. 1. Check the buffer reservoirs to insure that adequate volume is present, and tubing is resting on the bottom of the vessel(s). Use water for this operation or buffers of your choice. 2. Turn on the instrument and computer. Open the Unicorn software System Control window. 3. Use the manual control panel to wash pumps B2, B1, A2 and A1. 4. Flush the sample loop with start buffer by attaching a filled syringe to the Luer lock sample loading port. 5. Fill the sample loop with 0.1% acetone in start buffer (or water). 6. Open the Method Editor, then open a program for SEC (simplest, isocratic elution). a. Method Settings choose a small column volume, e.g. 1 ml; set the flow rate = 1 ml/min; unit of measure = CV detectors = A280, conductivity; ph detector OFF; restrictor only position default pumps = A1, B1 %B = 50 b. Equilibration flow rate use system setting %B = 50% or your choice Outlet = waste c. Injection Volume to inject = 0.6 ml Wash loop with 1 ml Outlet = waste (or for fun, collect some fractions; check out the options) d. Elution 10 CV Use system settings e. Save the method with a new name 7. Run the program: open System Control window; File\Open\your new file DOUBLE CLICK. Click through the windows ( Next ) until you arrive at the final one with a Start button. Accept the default name and click Start. Away you go. Upon completion of the run, the system will stop automatically. 8. Open the Evaluation window and the Results Navigator. The most recent chromatogram (yours) will be at the bottom of the list. Double click it to open. You can print it, or choose to save it as a pdf. 9. Return the instrument to the storage state, by flushing pumps and flow path with 20% EtOH. Monitor to insure the pumps do not run dry.