THE TUNNELS IN GUADARRAMA FOR THE HIGH SPEED RAILWAY

Similar documents
New Technologies applied to the design and optimization of tunnel ventilation systems

METRO System Design. Witt&Sohn AG Aug-11

OPTIMIZING THE LENGTH OF AIR SUPPLY DUCT IN CROSS CONNECTIONS OF GOTTHARD BASE TUNNEL. Rehan Yousaf 1, Oliver Scherer 1

Appendix FRANCE Lyon Croix-Rousse Tunnel

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOUR IN A MODERN TRAFFIC TUNNEL IN CASE OF FIRE INCIDENT

ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN

VENTILATION OF PROTECTED AREAS IN ROAD TUNNELS

Validation of a Neutral Pressure Isolation Room

THE A10-TAUERN TUNNEL VENTILATION SYSTEM FROM A CONTRACTOR S PERSPECTIVE. (Experiences and lessons learned)

Appendix FRANCE Annecy Tunnel Courier

Internal Arc Simulation in MV/LV Substations. Charles BESNARD 8 11 June 2009

excavation work and necessary for the exhalation of workers. After conducting the ventilation network analysis, the result should be checked whether t

PROBLEMS ON VENTILATION IN COMPLEX CITY TUNNELS

THE TÚNEL LA LÍNEA - A CHALLENGE FOR VENTILATION AND SAFETY

The Usage of Propeller Tunnels For Higher Efficiency and Lower Vibration. M. Burak Şamşul

Gas Accumulation Potential & Leak Detection when Converting to Gas

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios

CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS

High Speed Rail Tunnel Aerodynamics: Transient pressure and loadings on fixed tunnel equipment

NZQA unit standard New US 1Non-coal of 7145 version 1 Page 1 of 5

NZQA unit standard version 5 Page 1 of 5. Describe, develop, and maintain basic ventilation systems for an underground coal mine

Simon Peggs, dipl. eng. FH AlpTransit Gotthard Ltd., Lucerne, Switzerland / Project Manager Mechanical Equipment GBT

AN INVESTIGATION OF LONGITUDINAL VENTILATION FOR SHORT ROAD TUNNELS WITH HIGH FIRE HRR

VENTILATION AND ESCAPE FACILITIES FOR SHORT CUT-AND- COVER URBAN TUNNELS

TABLE OF CONTENTS PART 11 - FIREFIGHTING

On the design and control of complex tunnel ventilation systems applying the HIL tunnel simulator

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

Effective protection thanks to the latest technology

OPTIMISATION OF VENTILATION IN THE CASE OF A FIRE IN ROAD TUNNELS

THE INFLUENCE OF PRESSURE GRADIENTS ON VENTILATION DESIGN SPECIAL FOCUS ON UPGRADING LONG TUNNELS

Tunnel Ventilation at High Altitudes

Special edition paper

Increased Project Bankability : Thailand's First Ground-Based LiDAR Wind Measurement Campaign

Safety, ventilation and climate in rail tunnels

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

THE INFLUENCE OF THE NOSE SHAPE OF HIGH SPEED TRAINS ON THE AERODYNAMIC COEFFICIENTS

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

THE A10-TAUERN TUNNEL VENTILATION SYSTEM FROM A CONTRACTOR S PERSPECTIVE.

CROSSRAIL INFORMATION PAPER A4 VENTILATION AND INTERVENTION SHAFTS

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

TUNNEL SAFETY BY VENTILATION AN ILLUSION?

Time Activity Instructors Remarks 9:00 Explanation about San Pedro facilities. Introduction INTRODUCTION TST TST TST TST

Media event. Safe passage through the new Gotthard Base Tunnel. Erstfeld, 3 February 2016.

The routine maintenance and inspection of local exhaust ventilation (LEV)

Series/Parallel Pumps Bench PBSPB

Validation of 3D turbulent CFD modelling of retrofitting works ventilation with experimental measurements for a rail tunnel

VENTILATION DURING TUNNEL CONSTRUCTION INDUSTRY CONSIDERATIONS

"LABORATORY SAFETY SERIES"

Issue 8. Module S5. Passing a signal at danger or an end of authority (EoA) without a movement authority (MA) GERT8000-S5 Rule Book

MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS

SAFE AND ENVIRONMENTALLY FRIENDLY

Lockout/Tagout CE Marking Requirements WHITE PAPER

A Computational Assessment of Gas Jets in a Bubbly Co-Flow 1

Evaluation of the optimum conditions for a local ventilation system in connection with the mine ventilation network

NZQA unit standard 7145 version 9 Page 1 of 5. Design and maintain effective ventilation systems for an underground coal mine

LONGITUDINAL AIR VELOCITY CONTROL IN A ROAD TUNNEL DURING A FIRE EVENT

How to achieve fluid traffic

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS. A high-capacity EBA system [CSVS] [main purge]

Free Surface Flow Simulation with ACUSIM in the Water Industry

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

AVEMS & UNICLIMA joint Position paper on Regulation (EU) No.1253/2014 Paris, June 8 th

Volume 2, Issue 5, May- 2015, Impact Factor: Structural Analysis of Formula One Racing Car

SAFETY AND HEALTH IN THE USE OF CHEMICALS AT WORK

Appendix ITALY Valsassina Tunnel near Lecco (Lombardy)

When you complete this module you will be able to: Describe procedures needed to enter into, or work safely in confined spaces.

LABORATORY SAFETY SERIES: Laboratory Hoods

COMPLEX COMMISSIONING AND QUANTITATIVE TESTING OF THE GOTTHARD BASE TUNNEL VENTILATION SYSTEM

FIRE AND SMOKE ANALYSIS OF

Proficiency Module Syllabus. P601 - Thorough Examination and Testing of Local Exhaust Ventilation Systems

REVIEW Effects of Side Vents and Span Numbers on Wind-Induced Natural Ventilation of a Gothic Multi-Span Greenhouse

FIRE PROTECTION. In fact, hydraulic modeling allows for infinite what if scenarios including:

VB85/ Pressure regulating valve (Unloader)

Control the air. Control your business.

WIND LOADS / MOORING & FISH TAILING. Arjen Koop, Senior Project Manager Offshore Rogier Eggers, Project Manager Ships

STANDARD PROCEDURE OF A TIGHTNESS TEST OF A SOLAR COLLECTOR BOX. (EUROSUN 2000 SOLAR CONGRESS)

ESTATES OFFICE OPERATIONS WORKS INSTRUCTIONS WI 6. Fume Cupboards, Ventilated Cabinets, Local Exhaust Ventilation

Bogo Operations Pollution Incident Response Management Plan

EN DE FR. A look back at the wind tunnel s history. An overview of the wind tunnel

Electrical, electronic and control engineering at the operational level

Review and Assessment of Engineering Factors

Chapter 4 Route Window C3 Hyde Park and Park Lane shafts. Transport for London

Development of Biomimicry Wind Louver Surface Design

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

vento specification sheet

Issue 4. Module TS10. ERTMS level 2 train signalling regulations. GERT8000-TS10 Rule Book

MODELING&SIMULATION EXTRAPOLATED INTERNAL ARC TEST RESULTS: A COUPLED FLUID-STRUCTURAL TRANSIENT METHODOLOGY

STATIONKEEPING DYNAMIC POSITIONING FOR YACHTS. Hans Cozijn

Computational Fluid Flow Analysis of Formula One Racing Car Triya Nanalal Vadgama 1 Mr. Arpit Patel 2 Dr. Dipali Thakkar 3 Mr.

TUNNEL KASTELEC - PLANING, REALISATION, TESTING, EXPERIENCES

Pressure Measurement Unit HEMP

Guidance on room integrity testing and its interpretation

APPLICATION OF AIRTIGHTNESS TO HEALTHCARE BUILDINGS

Introduction (2 of 2) Systematic approach should be followed

A18W35_MASE 130_F_EN MANUAL

TOWN OF LINCOLN ARENA FACILITIES OPERATIONAL SAFETY POLICY

Reference Points. Guide to Road Tunnel Safety Documentation

EEF. Fatigue Testing Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Engineering and Technical Teaching Equipment

Tunnel Ventilation The Actual State of the Art

Transcription:

THE TUNNELS IN GUADARRAMA FOR THE HIGH SPEED RAILWAY

MAP GUADARRAMA TUNNELS

THE TUNNELS IN GUADARRAMA FOR THE HIGH SPEED RAILWAY The tunnels in Guadarrama for the high speed train (AVE) entered into service on December 23rd, 2007. They extend from Miraflores de la Sierra (Madrid) to the outlying area of Segovia. They pass through the Madrid mountain range under the mountain of Peñalara. NORTH SIDE SOUTH SIDE EMERGENCY PASSAGEWAY They are the fifth longest tunnels in the world, and the first tunnels of this kind that do not use intermediate ventilation shafts. The works consist of two parallel tunnels with a distance of 30 metres between the centre of each tunnel. A tunnel has been constructed for each direction in which trains will run. They have a length of 28.4 kilometres and a section of 52 m2. They were excavated directly from the tunnel portals without any intermediate access points, given that the area where the tunnels are located is considered to be of high environmental significance. The tunnels are interconnected by means of 250 metres of emergency passageways. In addition, they have a 500 metre long emergency area, which is located at an equidistant point from both tunnel portals. The area can hold up to 1200 people if the tunnels have to be evacuated. This area is accessed via the emergency passageways. The construction and entry into service of the tunnels has taken place over a five year period. ZITRON is the company which was chosen to carry out the ventilation of the tunnels (both during the works themselves and when the tunnels enter into active service). 1

VENTILATION DURING CONSTRUCTION Ventilation during construction was an important challenge, as the project involved one of the longest blind tunnel ever to be ventilated approximately 15 kilometres in length. The system functioned by the entry of fresh air through tubes driven by several fans to the work face. The polluted air was then displaced to the exterior through the tunnel itself. This was necessary as a human team had to work in the tunnel s interior to create the internal infrastructure of the tunnel. This team was continuously exposed to harmful and hazardous gases from equipment and machines, and had to receive fresh air in order to ensure that working conditions were safe. In accordance with the particular characteristics of each mouth, the following fans were used during the tunnel works: NORTHERN PORTAL: 2 x ZVN 1-20-450/4 (One for each tunnel) SOUTHERN PORTAL: 3 x ZVN 1-18-315/4 (One for each tunnel) NORTH SIDE NORTH SIDE VENTILATION DURING OPERATION RAILWAY HIGH SPEED TUNNEL 28 km SOUTH SIDE Initially, the definitive ventilation system planned for these tunnels was ventilation by means of two main stations located at the tunnel ends, with closing doors at the tunnel entrances in order to pressurise one of the tunnels. However, after having studied the problems associated with a possible failure in the opening and closing of the doors with a high speed train in the tunnel, the decision was made to carry out a new study of the ventilation system in order to replace the tunnel doors with a pneumatic closure system using jets of air, thus ensuring that the ventilation system proposed in the project would function correctly. The solution for the definitive ventilation of the Guadarrama tunnels was reached using CFD (Computational Fluid Dynamics). This technique was used to perform multiple simulations in order to determine the most suitable ventilation system for a railway tunnel of this length (28.5 Km without intermediate ventilation shafts). SOUTH SIDE 2

The definitive ventilation system consists of a series of structural elements design with the aid of CFD software. Each main ventilation station located between both tunnels is connected to the tunnels by means of connecting passageways with a specific structure - which has been optimised to improve the entry of air flow into the tunnel. The use of Saccardo nozzles located at the top of the false tunnels of each tunnel and the air inflow angle, designed specially for the nozzles, provides an optimal ventilation system for the service. CONNECTION GALLERY SOUTH SIDE The CFD program was not only used to configure the definitive ventilation system, but also to optimise some of the components of the circuit and introduce extensive improvements to pressure loss in the system (energy saving was one of the main design principles). SACCARDO NOZZLES SOUTH SIDE These tunnels have been designed in such a way as to ensure the safe and efficient functioning of the ventilation system, with a series of exclusively designed structural elements. 3

There are three buildings in each portal which are used in the ventilation system. The main station is located between the tubes, with three ZVN 1-20-560/4 fans (one of which is used for back-up purposes). There are two Saccardo nozzle stations located in the false tunnels of each tunnel mouth. Each of these stations also has three ZVN 1-20-450/4 fans (one of which is also used for back-up purposes). The two fundamental principles for emergency operation procedures are: CONNECTION GALLERY DAMPERS - In tunnel where an accident occurs the air speed must be 3 m/s - The safe tunnel must have a pressure of at least 50 Pa more than the tunnel where the accident has occurred, to ensure that fumes do not enter the tunnel. NORTH SIDE SOUTH SIDE 4

The following operational modes will apply in case of emergency: VENTILATION MODE This operational mode is applied in the tunnel where the accident occurred, especially if the accident results in the emission of fumes. The main ventilation station, which is chosen according to the protocol established by the control centre, will start to administer a specific air flow generated by two fans (with a third fan for back-up purposes). At the same time another two fans in the Saccardo nozzle station at the same end of the tunnel will provide further air flow (with a third fan for back-up purposes). The air flow in the tunnel will thus reach a speed of 3 m/s. The other fans in this tunnel will not be used. All of the numeric values and the duty point of the fans were obtained through several CFD simulations. PRESSURIZATION MODE This procedure is used in the safe tube, which the train passengers will access through the emergency passageways. The main ventilation station, which is not providing air for the tunnel where the accident occurred, is used. This station will provide a flow of air using two fans (with a third fan in back-up mode). At the same time another two fans in the Saccardo nozzle station at the same end of the tunnel will provide further air flow (with a third fan for back-up purposes). Two fans in the Saccardo nozzle station at the opposite end of the tunnel will provide further air flow (with a third fan for back-up purposes). 5

By doing this, we obtain an over pressurization of approximately 50 Pa in this tube at any point, compared to the damaged tube. The ventilation system for the Guadarrama tunnels, designed and manufactured by ZITRON are an important innovation for long railway tunnels, as intermediate ventilation shafts are not used and the ventilation system operates from the tunnel mouths. This system is not only used in emergency situations (for which it has been designed), but also also when the TALGO train passes through the tunnel each day or when maintenance works are carried out in the interior of the tunnel and fresh air has to be provided for the workers. MAIN STATION FAN ZVN 1-20-560/4 TESTS Before the official opening of the tunnel, ventilation tests were performed to check the validity of the system designed using the CFD software. During the general tests, the air speed was measured in the tunnel (which must be 3 m/s or greater when the emergency system is operating in a tunnel where an accident has occurred). These measurements were made using anemometers located in several sections of the tunnel close to both ends of the tunnel. In emergency situations, the other tunnel (safe tube) must have an overpressure of 50 Pa more than the tunnel where the accident occurred. This was checked during final tests. The natural draught in the tunnel was also checked in situ to see how it affects the air speed in the tunnel s interior (this is an important consideration for the control centre when deciding which stations will be employed during an emergency). The tests confirmed - and even exceeded- the designed performance expectations. Without any doubt, the GUADARRAMA tunnels also represent a milestone in emergency ventilation systems. 6

The tunnels are monitored from a control centre located in the Segovia Guiomar AVE station. This centre monitors the tunnels energy, lighting, signalling and communications systems, as well as fire detection and spreading, passageway aeration, the emergency area and, of course, the ventilation systems. HIGH SPEED RAILWAY GUADARRAMA TUNNELS These tunnels allow the journey from Madrid to Valladolid to be made in only 55 minutes. The trains which run on this line use the duck locomotives, which have been designed with a duck s head shape, to minimise the pressure waves produced when passing through tunnels and to reduce lateral wind effects. All these innovations combine to make these tunnels one of the most important projects in recent years. 7

ZITRON S TEST BENCH testing fan Pitot tubes test bench jet fans 8

settling means nozzles settling means auxiliary fan silencer

HEAD OFFICE Autovía AS II. nº 2386 Polígono de Roces 33211 Gijón (Asturias) Spain +34 985 168 132 zitron@zitron.com www.zitron.com