Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

Similar documents
Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

Natural Gas to L.P. Gas Conversion Kit

ACCESSORY KIT INSTALLATION MANUAL

Natural Gas to L.P. Gas Conversion Kit

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Instructions

Your safety and the safety of others are very important.

installation instructions

Installation Instructions

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Operator: Save these instructions for future use!

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36H SERIES Combination Gas Valve

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

ACCESSORY KIT INSTALLATION INSTRUCTIONS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Installation Instructions For Natural Gas Conversion

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

SL G3. Warning

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

G96 Series BASOTROL Dual Operator Valve

Gas Conversion Kit Pilot Ignition Heaters

Operator: Save these instructions for future use!

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Propane Conversion Kit Instructions

Operator: Save these instructions for future use!

JACKSON GRILLS PATIO FIRE

VR8305 Direct Ignition Combination Gas Control

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Instructions for High Altitude Conversion

ACCESSORY KIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

SL G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301

Conversion instructions from natural gas to propane

VR8200A Continuous Pilot Combination Gas Controls

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

Installation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F13, RXGY-F27 AND RXGY-F28

Natural Gas Conversion Kit

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

Installation Instructions

V8200A,C,H,M and VR8200A,C,H,M Continuous Pilot Combination Gas Controls

/2004 US/CA

GAS CONVERSION KIT Installation Instructions Range/Rangetop

VR8205S,T Direct Ignition Combination Gas Controls

VR8105, VR8205, and VR8305 Direct Ignition Combination Gas Controls

Natural Gas Conversion Kit

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41

Dual Solenoid Gas Valve Installation

Operator: Save these instructions for future use!

Installation Instructions

Operator: Save these instructions for future use!

G92 Series BASOTROL Automatic Pilot Gas Valve

Operator: Save these instructions for future use!

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

Operator: Save these instructions for future use!

BGA158 Series CE Approved Class A Shutoff Gas Valve

INSTALLATION & OPERATION MANUAL FOR Stockpot Range

INSTALLATION GUIDE Gas Rangetops

Propane Conversion Kit Instruction

INSTALLATION INSTRUCTIONS

Propane Conversion Kit Instruction

BGA158 Series CE Approved Class B Shutoff Gas Valve

INSTALLATION AND OPERATION INSTRUCTIONS

Propane Conversion Kit Instruction

VS8420 Millivolt Gas Valve

WARNING: AVERTISSEMENT. LP & HIGH ALTITUDE LP CONVERSION KIT FOR INSTALLATIONS IN the United STATES (0-10,000 Ft)

Gas Valve Replacement Kit

GM-7000 Series CE Approved Gas Control Valve

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

TB132. Gas Conversion Kits for NV & NVS Heaters. Issue 1.0 May Applies to models: NV & NVS

Installation Instructions

WARNING: FOR OUTDOOR USE ONLY

BGC258 Series BASOTROL Gas Valve

Freedom8 ShoeBox Compressor Manual

Booster Pump PB4-60 Replacement Kits

H15 Series BASO 100% Shutoff, Automatic Pilot Valve

SPECIFICATIONS CAPACITY

LITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH

SPECIFICATIONS ATTENTION

LNVx Gas Conversion Kit Instructions

INSTALLATION INSTRUCTIONS

GEN-1e CO2 Generator OVERVIEW INSTALLATION PROPANE GENERATORS ONLY NATURAL GAS GENERATORS ONLY

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

VR8305 Direct Ignition Dual Automatic Valve Combination Gas Controls

INSTALLATION INSTRUCTIONS

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

Transcription:

DESCRIPTION These kits are designed to convert from one gas type to another (eg. from NATURAL to PROPANE or from PROPANE to NATURAL) only for new heaters (5 years or newer) by replacing the gas valve spring and main burner orifices. These kits also require outlet gas pressure check and adjustments as required on page 3. Note: These kits will convert heaters using White-Rodgers DSI gas valve number 36J22. This conversion kit is to be installed by an authorized distributor or other qualified agency in accordance with the manufacturer s instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury, property damage or death. The qualified agency performing this work assumes responsibility for this conversion. FIRE OR EXPLOSION HAZARD CAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH Follow these warnings exactly. 1. Disconnect power supply (if equipped) to prevent electrical shock or equipment damage. 2. To avoid dangerous accumulation of fuel gas, turn off gas supply at service valve before starting conversion and perform Gas Leak Test after completion of conversion. COMPLETE KIT NUMBERS GAS CONVERSIONS KIT PART NUMBERS NUMBER OF BURNERS MODEL BTU CONVERTS FROM CONVERTS TO 44505650 1 33M Natural Gas Propane Gas 44505660 2 66M Natural Gas Propane Gas 44505670 3 100M Natural Gas Propane Gas 44505680 4 132M Natural Gas Propane Gas 44505690 1 30M Propane Gas Natural Gas 44505700 1 35M Propane Gas Natural Gas 44505710 1 40M Propane Gas Natural Gas 44505720 2 60M Propane Gas Natural Gas 44505730 2 70M Propane Gas Natural Gas 44505740 2 80M Propane Gas Natural Gas 44505750 3 100M Propane Gas Natural Gas 44505760 3 120M Propane Gas Natural Gas 44505770 4 140M Propane Gas Natural Gas 44505780 4 155M, 160M Propane Gas Natural Gas 1

REPLACING MAIN BURNER ORIFICE 1. Remove existing orifices from the manifold pipe using a 7/16 open-end or box-type wrench. (see Figure 1). 2. Replace orifices with those supplied in kit. Apply pipe joint compound or Teflon tape to threads of new orifice before placing in the manifold pipe. NOTE: Orifice sizes are indicated in the parts list of this kit and are stamped on the orifice for identification. 3. Tighten orifices to a snug fit using a wrench. Figure 1 Single Burner Unit Shown REPLACING THE GAS VALVE REGULATOR SPRING 1. Remove regulator cover screw. 2. Remove plastic regulator adjustment screw (beneath the cover screw). 3. Remove the regulator spring from regulator sleeve. 4. Insert the new regulator spring (provided in the conversion kit) into the regulator sleeve. 5. Replace the regulator adjustment screw. Adjust the outlet pressure as specified in the table below. 6. Replace the regulator cover screw. 7. Attach the WARNING label (provided in the kit) to the gas valve where it can be readily seen. Also attach the small NATURAL GAS or PROPANE GAS label to the top of the regulator cover screw. Figure 2 2

OUTLET GAS PRESSURE CHECK AND ADJUSTMENTS (WR DSI GAS VALVES) Gauges that measure pressure in pounds per square inch are not accurate enough to measure or set the manifold pressure. All measurements MUST BE made when the heater and all other gas burning equipment that is connectied to the gas supply system are operating at maximum capacity. Follow the instructions for gas pressure checks. Failure to perform gas pressure checks and adjustments can result in improper heater operation and can result in serious injury, property damage or death. 1. Turn off all electrical power to the system prior to connecting manometer hoses. 2. Turn the outlet pressure boss test screw (3/32 Hex allen wrench plug) in the center of the boss not more than one turn counterclockwise. Attach a 5/16 hose and manometer over the tapered outlet pressure boss on the valve (see Figure 3 below). If regulator needs to be adjusted, see instructions below. To Adjust Regulator: 1. Turn on power and energize the main gas valve. Remove regulator cover screw (see Figure 3 below). Turn regulator adjustment screw clockwise to increase presure, or counterclockwise to decrease pressure. Replace regulator cover screw and tighten securely. DO NOT EXCEED THE PRESSURES SHOWN IN THE GAS PRESSURE TABLE. 2. After testing pressure and adjusting the regulator, turn off all electrical power to the system, remove manometer hoses, turn outlet test screw (3/32 Hex) clockwise to seal pressure port. Tighten to 7 in-lb minimum. Turn on system power. Figure 3 3

Heater Model BTU GAS PRESSURE TABLE Gas Type Manifold Pressure Supply Pressure Minimum* Maximum 30, 35, 40, 60, 70, 80, 100, 120, 140,,155, 160 Natural 6 W.C. 7 W.C. 14 W.C. 33, 66, 100, 132 Propane 10 W.C. 11 W.C. 14 W.C. *Minimum permissible gas supply pressure for purpose of input adjustment. GAS LEAK TEST Perform the gas leak test using a leak detection solution or soapsuds solution at the orifices, pipe nipples and pressure boss screws or check by one of the methods listed in Appendix D of the National Fuel Gas Code, ANSI 2223.1-(latest edition). Bubbles forming indicate a gas leak. SHUT OFF GAS AND FIX ALL LEAKS IMMEDIATELY. DO NOT OMIT THE GAS LEAK TEST. DO NOT USE AN OPEN FLAME OF ANY KIND TO TEST FOR LEAKS! MARKINGS: 1. After conversion is complete, fill out the gas conversion identification label (provided in the kit) and attach on the nameplate or other location where it can be readily seen for future reference. Gas Conversion Kits and Components NATURAL GAS to PROPANE GAS 44505650 Converts to 33M BTU LPG 44505660 Converts to 66M BTU LPG 43872520 Main Burner Orifice (#52) 1 each 43872520 Main Burner Orifice (#52) 2 each 30755990 LPG Spring Kit #F92-0659 30755990 LPG Spring Kit #F92-0659 44505670 Converts to 100M BTU LPG 44505680 Converts to 132M BTU LPG (4 BURNER) 43872520 Main Burner Orifice (#52) 3 each 43872520 Main Burner Orifice (#52) 4 each 30755990 LPG Spring Kit #F92-0659 30755990 LPG Spring Kit #F92-0659 4

Gas Conversion Kits and Components PROPANE GAS to NATURAL GAS 44505690 Converts to 30M BTU NG 44505700 Converts to 35M BTU NG 43872980 Main Burner Orifice 3/32 1 each 43872410 Main Burner Orifice (#41) 1 each 44505710 Converts to 40M BTU NG 44505720 Converts to 60M BTU NG 43872380 Main Burner Orifice (#38) 1 each 43872980 Main Burner Orifice 3/32 2 each 44505730 Converts to 70M BTU NG 44505740 Converts to 80M BTU NG 43872410 Main Burner Orifice (#41) 2 each 43872380 Main Burner Orifice (#38) 2 each 44505750 Converts to 100M BTU NG 44505760 Converts to 120M BTU NG 43872410 Main Burner Orifice (#41) 3 each 43872380 Main Burner Orifice (#38) 3 each 44505770 Converts to 140M BTU NG (4 Burner) 44505780 Converts to 155M/160M BTU NG (4 Burner) 43872410 Main Burner Orifice (#41) 4 each 43872380 Main Burner Orifice (#38) 4 each 5