Proline Plus Mechanical Pipette

Similar documents
Sartorius Liquid Handling Products

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

DISCOVERY PRO - features

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

Transferpette. Lightweight precise rugged reliable!

Transferpette. Lightweight precise rugged reliable!

Transferpette. Single and Multichannel Pipettes

Tacta Mechanical Pipette User Manual

Phone: Fax: More information:

Phone: Fax: More information:

Pipette Tips. Purity and Performance Rainin BioClean Ultra Tips Deliver

PRODUCT EXTRA. Precision laboratory consumables, durables and service products including: Picus Electronic Pipette and Accessories

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

MULTICHANNEL. Labnet International, Inc.

RayPette Plus Autoclavable Pipette. User Manual

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

CALIBRATION AND ADJUSTMENT

The pipettes cover a volume range from 0.1µl to 10ml.

Qi Litre Ultrasonic Cleaner

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

Improving Pipetting Techniques

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Proline Plus pipette. User Manual Bedienungsanleitung Mode d'emploi Manual Usuario Instruzioni d'impiego Инструкция пользователя

A N F G J I C D D L A B C D E F

A N B P F G J I C D D L A B C D E F

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

PERFORMANCE TEST INSTRUCTIONS FOR BIOHIT PROLINE PIPETTORS

VWR HIGH PERFORMANCE PIPETTOR

A N B P G J I C D L D E

SoCal BioMed, LLC 4695 MacArthur Court, 11th Floor Newport Beach, CA Phone: +1 (424) Fax: +1 (323)

Pipettor. User Manual

Thermo Scientific F1-ClipTip Single Channel Multichannel

Fisherbrand. Finnpipette INSTRUCTIONS FOR USE PARK LANE Pittsburgh PA

Performance Verification of BioTek s Precision 2000 using Artel s Multichannel Volume Verification (MVV ) System

Transferpette -8/-12

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

VITLAB micropipette. Standard Operating Procedure (SOP)

Eppendorf Research fix variable multi Instruction Manual Bedienungsanleitung Mode d emploi Instruzioni d impiego Manual de Instrucciones

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

Good Pipetting Practice

Nichipet EX Plus II. User s Manual. Autoclavable & UV resistant. Digital micro pipette for liquid handling

User s Manual. Autoclavable & UV resistant Nichipet EX II. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

Other languages available on our website:

PIPETMAN F ENGLISH. Other languages available on our website:

PIPET TIPS. UniFit ZFR (Zero Fluid Retention) Tips Universal Fitting Pipet Tips

Corning Step-R. Repeating Pipettor. Instruction Manual

Prepared By: Lisa McAvoy 30/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

User s Manual. Autoclavable & UV r e s i s t a n t. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

Operating Instructions. Rainin Classic Manual Pipette

High-Throughput. Faster, Better 96 & 384-Well Pipetting Ultra Efficient and Extremely Versatile

Air Displacement Pipetting Modules. Total Integrated Liquid Handling

WITOPET PREMIUM PIPETTE USER S GUIDE

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

User's Manual. Autoclavable Nichipet EX Plus Digital micro pipette for liquid handling CERTIFIED ISO9001

Liquidator 96 Manual benchtop pipetting system

Varipette Operating manual

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

Pipetting and Determining Protein Concentration

Chapter 2. Pipetting techniques. Guide to Pipetting

ali-q TM Gravimetric Verification Procedure

Register your instrument! Eppendorf Research plus. User Adjustment

Gel Loading Practice MiniLab

Thermo Scientific Matrix MultiChannel Equalizer Pipette with Expandable, Equal Tip Spacing. User Manual

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

Adjust the Volume Display

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

NEO. User s Guide. Do not lubricate this pipette. The use of lubricant cancels the warranty of this pipette. NOTICE

User s Guide VARIABLE VOLUME MODELS. Variable volume single and multichannel models and fixed volume models

Using a micropipette to transfer exact liquid measurements in scientific experiments By: Nicole Hume

Standard Operating Procedure. Air Displacement Pipette Calibration

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

Register your instrument! Eppendorf Xplorer / Eppendorf Xplorer plus. Adjustment

Improve Process Reliability

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

Comfortable and Secure by Nature!

Transferpette -8/-12

How to Measure R7.1. Reference. I. Linear dimensions

Technology for Vacuum Systems Instructions for use

SoftGrip Single Channel Pipettes User Manual New Photo To Come

2017 PRODUCT GUIDE LIQUID HANDLING EXTRACTION PURIFICATION AUTOMATED SOLUTIONS SERVICES

Laboratory Safety Training. Environmental Health and Safety

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

Userts Manual. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC) Annex III self-declared ISO 8655 STANDARD

Operating Instructions. Liquidator 96 Manual benchtop pipetting system

Gilson Liquid Handling. Catalogue

MICROMAN ENGLISH. Other languages can be consulted and downloaded on our website,

Inquiry Module 1: Checking the calibration of a micropipette

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

BIOSAFETY SELF AUDIT PRINCIPAL INVESTIGATOR/PERMIT HOLDER: CONTAINMENT LEVEL: 1 2 (Shaded) RISK GROUP: 1 2 AUDIT TO BE COMPLETED BY (DATE):

Bioscience Laboratory Ergonomic Check List

Air Displacement Pipetting Module. Total Integrated Liquid Handling

Pressure is our Business

Any laboratory is equipped with specific tools, equipment,

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

Stringway ML100 Review. Stringway ML100. A Review MSRP $1,195.00

Decontamination Procedures for Gilson Pipettes

Ensuring pipette & weighing device performance: Verification & Calibration

Multiplate Platelet Function Analyzer: An Overview

Real World Metric System

Transcription:

Proline Plus Mechanical Pipette 1

Proline Plus mechanical pipettes Dependable durability Sartorius Biohit s mechanical pipette family Proline Plus is designed to offer comfort and quality in every day manual pipetting. While it shares many of the excellent features of mline, it has a personal design and a robust feel for heavier use. In addition, it has the widest pipette range, including fixed volume pipettes, for when volumes need to be ready-set to avoid errors. Proline Plus pipettes are an excellent choice for both experienced laboratory professionals and students. The widest range of pipettes for various users and applications Ergonomic design with light pipetting forces, comfortable handle and finger support for reduced risk of strain injuries Minimized risk of contamination with Safe-Cone Filters and full autoclavability Highly durable with strengthened structure also for heavier use Light pipetting forces & ergonomic design Prevents repetitive strain injury (RSI) Widest range of pipettes, both adjustable and fixed volume, available adjustable volume pipettes for professionals fixed volume pipettes for specific applications to avoid volume errors Fully autoclavable Fully autoclavable without disassembling Easy to steam sterilize, improves purity Optiload tip loading mechanism in multichannel models Allows tip loading with an equal constant force onto every channel Enables perfect tip sealing onto every individual tip cone Makes tip ejection light and easy Safe-Cone Filters available for models > 10 µl Contamination free pipetting 2

Features and benefits Volume setting with color-coded click stop Easy to use volume setting Eases correct tip volume selection through matching color code Ergonomic finger support No need to squeeze the pipette during pipetting, reduces the risk of RSI Thermal insulation of internal components Improves accuracy Large numbers used on volume display Quick and easy-to-read volume minimizes risk of volume setting errors Volume noted on display Eases correct tip volume selection Materials have high chemical and UVresistance Highly durable and long lasting pipette Only three parts to disassemble The easiest pipette to clean and maintain, improves purity Easy to use do-it-yourself calibration Quick re-calibration possible for different liquids 3

Widest range of pipettes The Proline Plus family includes the widest range of pipettes, from 3 µl/µl to 10 ml, as both adjustable and fixed volume devices. The fixed volume pipettes are particularly useful in student laboratories or in any laboratory where the application requires a constant volume. It is also ready-set to avoid errors. Ergonomic design A comfortable handle and ergonomic finger support enable effortless pipetting. There is no need to squeeze the handle during pipetting, thereby reducing the risk of RSI. No rocking needed Perfect tip sealing with Optiload tip loading mechanism in multichannel pipettes All Proline Plus multichannel pipettes are equipped with spring loaded tip cones the Optiload mechanism developed by Biohit, which secures even tip sealing and simultaneously allows tips to be loaded and ejected with minimum force. This is a particular advantage in multichannel models, where tip loading and ejecting generally require more force. Using less force reduces the risk of hand injuries. Prevent contamination with Safe-Cone Filters Replaceable Safe-Cone Filters act as a barrier, preventing aerosols or fluids from reaching the internal components of the pipette. Safe-Cone Filters are available for all Proline Plus models greater than 10 μl. These filters must be replaced regularly, and in every case of overaspiration. Maintenance and calibration made easy No opening tools are needed when cleaning and maintaining Proline Plus pipettes, and only three parts need to be cleaned. These pipettes can be easily calibrated using the tool provided with them. 4

Proline Plus - Ordering details Cat. No. Channels Volume Range (µl) Increment (µl) Test Volume (µl) Inacc. (%) Impr. (%) Safe-Cone Filters Standard Plus Optifit Tips (µl) SafetySpace Filter Tips (µl) 89082-274 1 0.1-3 0.002 3 1. 0.3 89082-276 1 0.-10 0.01 10 1 89082-278 1 2-20 0.02 20 10 2 89177-094 1-0 0.10 0 2 89082-280 1 10-100 0.10 100 0 10 89082-282 1 20-200 0.20 200 100 20 89082-284 1 100-1000 1000 00 100 89082-286 1 00-000 10.0 000 200 00 89082-288 1 1-10 ml 20.0 10000 000 1000 89082-290 8 0.-10 0.01 10 1 89082-292 8 10-100 0.10 100 0 10 89082-294 8 30-300 0.20 300 10 30 89082-296 12 0.-10 0.01 10 1 89082-298 12 10-100 0.10 100 0 10 89082-300 12 30-300 0.20 300 10 30 1.30 2.40 10.00 0.90 1.20 1.40 0.80 0.80 0.0 1.20 4.00 0.70 4.00 0.70 0.80 1.60 6.00 0.40 0.30 0.0 0.1 0.40 0.1 0.30 0.80 0.20 0.20 0.40 0.20 0.30 0.20 0.30 4.00 0.2 0.70 0.2 0.0 4.00 0.2 0.70 0.2 0.0 - - 10 10 - - 10 10 13-00 - 200 20 1000-114 1000-122 200 120 1000-114 1000-122 200 1000-112 1000-120 200 120 200 300 349-664 1000-118 1000 1000 349-666 1000-116 000-349-666 1000-116 10 000 - - - 10 10 1000-114 1000-122 200 120 1000-112 1000-120 300 - - 10 10 1000-114 1000-122 200 120 1000-112 1000-120 300

Proline Plus FIXED Volume, single-channel - Ordering details VWR Cat. No. Channels Volume Range (µl) Increment (µl) Test Volume (µl) Inacc. (%) Impr. (%) Safe-Cone Filters Standard Plus Optifit Tips (µl) SafetySpace Filter Tips (µl) 89082-302 1-1.30 1.20 - - 10 10 89082-304 1 10-10 0.80 0.80 - - 10 10 89082-306 1 20-20 0.0 13-00 - 200 20 89082-308 1 2-2 0.0 0.30 100-114 100-122 200 120 89082-310 1 0-0 0.0 0.30 100-114 100-122 200 120 89082-312 1 100-100 0.0 0.30 100-114 100-122 200 120 89082-314 1 200-200 0.40 0.20 100-112 100-120 200 200 300 89082-316 1 20-20 0.40 0.20 349-664 1000-118 1000 00 1000 89082-318 1 00-00 0.30 0.20 349-664 1000-118 1000 00 1000 89082-320 1 1000-1000 0.30 0.20 349-664 1000-118 1000 1000 89082-322 1 2000-2000 0.30 0.1 349-666 1000-116 000-89082-324 1 000-000 0.30 0.1 349-666 1000-116 000-89082-326 1 10 ml - 10000 0.20 349-666 1000-116 10 000 - Pipette stands and accessories - Ordering details Cat. No. Item 47746-178 Carousel Stand for six pipettes 80087-478 Linear Stand Linear Stand Carousel Stand 6

Proline Plus -Pack With the Proline Plus -Pack you can affordably replace your used mechanical pipettes with new ones or set up new workstations for every researcher. A set of five Proline Plus mechanical pipettes, covering the volume range from 0. μl to 000 μl, a Carousel Stand, 200 μl Optifit Tips and an Elbow Pad are included in the pack. Proline Plus -Pack - Specifications & Pricing VWR Cat. No. Description US List Price ($) 89218-762 - Proline Plus pipettes 0.-10 μl, 10-100 μl, 20-200 μl, 100-1000 μl, 00-000 μl - Sartorius Optifit Tip tray box and Refill Tower 0.-200 μl - Carousel Stand - Elbow Pad 88 7

Contact Details VWR International 1-800-932-000 www.vwr.com 8 1214 Lit. No. 191202W