HYDRA-line. HYDRA-Gauges Ultra High Purity Pressure Gauge Model HG. Pressure Systems. Applications. Special features. Description

Similar documents
High-performance submersible pressure transmitter For level measurement Model LH-10

Gas density monitor With integrated transmitter Model GDM-100-TI

Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34

Expansion Thermometers Stainless Steel Series, Model 70

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Bourdon tube pressure gauge, stainless steel For extremely low ambient temperatures down to -70 C Model PG23LT, with case filling

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-20

Pressure Equalising Valves Model , for Differential Pressure Gauges

Precision pressure sensor Basic version Model CPT6020

High-performance submersible pressure transmitter For level measurement Model LH-20

Hydraulic hand test pump Models CPP700-H and CPP1000-H

High Purity & Ultra High Purity

High-performance submersible pressure transmitter For level measurement Model LH-20

Mechanical Pressure Measurement

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Differential pressure gauge For the process industry Model , all-metal media chamber

Pneumatic service kit Model CPG-KITP

Hand-held pressure calibrator with integrated pump Model CPH6600

Precision digital pressure gauge Model CPG1000

High-speed pressure sensor Model CPT6140

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

SITRANS P measuring instruments for pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Digital pressure gauge Model CPG500

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Hydraulic pressure balance Model CPB5800

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Type S-10, S-11 General Purpose Pressure Transmitters

Submersible pressure sensor High-performance Model LH-20

Pneumatic dead-weight tester Model CPB3500

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Pneumatic high-pressure controller Model CPC7000

Bourdon tube pressure gauge for diaphragm seals

Digital pressure gauge Model CPG500

Notes on equipment protection per EN/IEC and NEMA For Bourdon tube or diaphragm pressure gauges

Nominal size dim 63mm. Option with case dim 50 mm. Aluminium, white with black lettering

How to specify a product. Process Sensors and Mechanical Instruments

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Pressure Transmitters 36 F-27839

OPTIBAR P 1010 C Technical Datasheet

Notes on equipment protection to DIN EN and NEMA

Aluminium, white with black lettering. Bar. Option with unit bar/pa, bar/psi, kpa, MPa, psi

Pressure Measurement Single-range transmitters for general applications

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow, Level & Temperature Products for Ultra-Clean Processing P R E C I S I O N S E N S O R S

Dead-weight tester High-pressure version Model CPB3800HP

JUMO dtrans p30 Pressure Transmitter

Measurement of Low GAS & Liquid Flows

Programmable pressure and temperature transmitters PTM/RS485

780S Ultra High Purity Series

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

Industrial pressure controller Model CPC4000

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Diaphragm pressure gauge guard MDM 902

SPD310/SPD360 Air Differential

BDT20 Safety process pressure gauge 100 & 160mm

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

GA24 Technical Datasheet

HP/UHP Spring-Loaded Regulator

VA40 - VA45 Technical Datasheet

Mass Flow Controller (MFC) for Gases

9700 Transmitter Submersible hydrostatic level transmitter

Autocalibration Systems For In Situ Oxygen Analyzers

AMS 2710 PCB pressure sensor module with V output

Instruction Manual Contact Pressure Vacuum Gauge

Pressure transmitter PASCAL Ci4

Product Catalogue INDUSENS Pressure Transmitters

P900. P900, Datenblatt Seite 1 DESCRIPTION

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

ABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers

Instruction Manual Differential Pressure Transmitter

Product Catalogue. P-SERIES Pressure Gauges

DPC-30 DPC-100. Reference Manual

Types and approvals. Page 1/6. Data Sheet

AMS 6916 Board mount pressure sensor with ratiometric analog output

Mass Flow Controller (MFC) for Gases

Technical Data. Dimensions

Level switches Series LD Vibrating fork level switch for liquids and solids

Buying more than 11 gauges? Call Lesman for additional discounts.

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

L3 Pressure and Level transmitter

ATM.ECO - Analog Pressure Transmitter

Level switches Series LD Vibrating fork level switch for liquids and solids

Pressure gauges EN All stainless steel construction PBX100, PBX150 (1.18) Functional and constructive characteristics

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Pilot valves for pilot operated servo valves

Programmable pressure and temperature transmitters PTM/RS485

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Digital dead-weight tester Model CPD8500

Transcription:

Pressure Systems HYDRA-Gauges Ultra High Purity Pressure Gauge Model HG WIKA Data Sheet SP 99.20 Applications Semiconductor industry UHP-liquid chemicals distribution Special features Patented double diaphragm Perfluoroalkoxy (PFA) wetted parts Stainless steel pressure measurement devices Gauge is 360 rotatable even after installation Optional: electrical alarm contacts 360 rotatable Description HYDRA-line Our pressure measuring instruments of the HYDRA-line product family have been developed in co-operation with well-known customers in the semiconductor industry. The complete product concept has been adapted to the special requirements of the process equipment and UHP chemicals distribution system sectors. The HYDRA-Gauge pressure gauge offers high accuracy and reliability, ultra clean wetted parts and surfaces. Furthermore, the production of all wetted parts, cleaning assembly, calibration and packaging takes place in a class 100 cleanroom. HYDRA-line Model HG, 63 mm gauge stainless steel series with black Teflon coating and in-line 1/2" flare process connection 360 rotatable Double safety The patented HYDRA double diaphragm system enables a safe and reliable separation of the pressure sensor from the process medium. Simultaneously diffusing process media such as HF or HCI vapours are given off to the environment to avoid any falsification of the measuring result or the destruction of the sensor element. The offer for sale of this product does not infer or imply chemical compatibility with specific applications. Some applications of this product can and will cause diffusion of chemicals through the diaphragm materials. HYDRA-line Model HG, 63 mm gauge stainless steel series with black Teflon coating and dead-end 1/2" flare process connection Page 1 of 6 HYDRA-Sensor Model HS see data sheet SP 99.21 HYDRA-Dry Model HD see data sheet SP 99.22

Specifications Model HG, HYDRA-Gauge Pressure ranges bar 0 2.5 0 4 0 6 Other non-wetted parts Gauge asystem fill fluid psi 0 30 0 60 0 100 kpa 0 250 0 400 0 600 Overpressure safety bar 40 1) in-line 3/8" flare, ½" flare, ¾" flare, 1" flare, 1 ¼" flare dead-end ¼" flare, 3/8" flare, ½" flare dead-end ¼ NPT female Pressure measurement device Design according to EN 837-1 Accuracy % of span ± 1.6 Material Wetted parts Permissible temperature range Nominal size 63 mm (lower mounting / center back mounting) PFA or TFM (modified PTFE) PVDF, EPDM, FPM/FKM Stainless steel, black Teflon coating KN 75 50/50 mix semiconductor grade IPA (Isopropyl Alcohol/DI Water) precision filled and not field refillable Process C +5... +60 (+41 +140 F) Ambient C +5... +60 (+41 +140 F) Storage C -20... +60 (-4 +140 F) Working range 1) Steady Fluctuating Short time Ingress protection per IEC 60 529 / EN 60 529 IP 54 3/4 of full scale value 2/3 of full scale value full scale value 1) Limited by maximum pressure rating of the process connection see diagram below Considerations for use: This transmitter can be rotated a full 360 by hand. No tools required. The transmitter can not be removed or the central PVDF nut loosened from the housing as this may cause the fill fluid to leak destroying the measuring unit. Pressure-temperature rating pressure / bar 12 10 8 6 4 2 0 0 20 40 60 temperature / C 1/4" and 3/8" 1/2" 3/4" 1" 1 1/4" only up to 25 C Page 2 of 6

Dimensions in mm HYDRA-line, Model HG, in-line flare process connection HYDRA-line, Model HG, in-line flare process connection, with alarm contacts 2442 413.01 2442 405.01 Cable length 5 m (standard) Dimensions in mm H L L 1 F B 1 B 2 Ød 2 In-line 3/8" flare 156 118 127 16 40 62 5.5 In-line 1/2" flare 156 122 133 16 40 62 5.5 In-line 3/4" flare 162 122 133 19 40 62 5.5 In-line 1" flare 186.5 165 179 25 56 78 6.5 In-line 1 1/4" flare 186.5 224 238 25 56 78 6.5 Page 3 of 6

HYDRA-line, Model HG, dead-end process connection 2436413.01 2436481.01 Dimensions in mm H 1 SW1 SW2 Ød 2 Dead-end 1/4" flare 194 ± 2 27 11/16" 64 Dead-end 3/8" flare 194 ± 2 27 15/16" 64 Dead-end 1/2" flare 197 ± 2 27 17/16" 64 Dead-end 1/4 NPT female 150 ± 2 27-64 Electrical Alarm Contacts Electrical alarm contacts make or break an electric control circuit depending on the position of the instrument's pointer. Points of contact actuation are adjustable over the full extension of the scale graduation. The gauges feature a hub in the window for an adjustment key. Contact actuation is made when there is an upper or lower deviation of the set desired value by the instrument pointer. Electronic contact Model 830 E The electronic contact is intended to be connected to a PLC control unit (SPS) or for direct switching of small loads. The switch outputs have a PNP characteristic. 360 rotatable Specifications Range of operating voltage: DC 10... 30 V Switching current: 100 ma Make contact (function index 1) This contact makes, when the rising pressure approaches the set-point. Example: Set-point at 2 bar, pressure at 1 bar contact is open Set-point at 2 bar, pressure at 3 bar contact is closed HYDRA-line Model HG, 63 mm gauge stainless steel series with electrical contacts and in-line 1/2" flare process connection Break contact (function index 2) This contact breaks, when the rising pressure approaches the set-point. Example: Set-point at 2 bar, pressure at 1 bar contact is closed Set-point at 2 bar, pressure at 3 bar contact is open For further information on electrical alarm contacts see data sheet AC 08.01. Page 4 of 6

Ordering information code for pressure system HYDRA-line, Model HG Field No. Code Features E D G H Unit dual scale bar / psi dual scale psi / bar dual scale kpa / bar dual scale kpa / psi 1? other please state as additional text Range BF 0 bar... 2.5 bar 0 psi... 30 psi 0 kpa... 250 kpa BG 0 bar... 4 bar 0 psi... 60 psi 0 kpa... 400 kpa BH 0 bar... 6 bar 0 psi... 100 psi 0 kpa... 600 kpa 2?? other please state as additional text Connector position U lower mount 3 B center back mount 1) Window 4 A acrylic Z Electrical contacts without S electronic contact PNP, 1. makes / 2. breaks model 830.12 E 5? other please state as additional text 06 in-line 3/8 " flare 08 in-line 1/2 " flare 12 in-line 3/4 " flare 16 in-line 1 " flare 20 in-line 1 1/4 " flare 38 dead-end 1/4 " flare 40 dead-end 3/8 " flare 42 dead-end 1/2 " flare 6 50 dead-end 1/4 NPT female Flare nut 77 PFA only for flare connections, not for NPT 75 PVDF only for flare connections, not for NPT 7 ZZ without only with NPT connections System fill fluid 8 L1 KN 75 iso-propyl-alcohol (IPA) / DI-water 50:50 1) Additional order info YES NO 9 1 Z additional text Please state as clearly understandable text! 1) Not available with electrical contacts Order code: 1 2 3 4 5 6 7 8 9 HG - A L1 - Additional text: Optional designs on request Page 5 of 6

Modifications may take place and materials specified may be replaced by others without prior notice. Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Page 6 of 6 9017054 09/2007 GB WIKA Alexander Wiegand GmbH & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Phone (+49) 93 72/132-0 Fax (+49) 93 72/132-406 E-Mail info@wika.de www.wika.de