Effective protection thanks to the latest technology

Similar documents
SAFE AND ENVIRONMENTALLY FRIENDLY

TOTAL SAFETY. It adapts perfectly to the problems of each project while being completely environmentally friendly and pollution-free.

with FE -13 TM Most DuPont FE-13 systems are designed with a concentration of 15.9% whereas the NOAEL level of this extinguishing agent is 30%.

Quick Specs. INERGEN Clean Agent Fire Suppression System

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

KFI Approved. High Pressure CO2 System Technical Datasheets

BERMAD Fire Protection Hydraulic Control Valves

TECHNICAL DATA. than the water inlet pressure to the concentrate

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

Piped Air SCBA Refilling System Standard

Guidance on the maintenance and inspection of fixed CO 2 fire-extinguishing systems

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Unit 24: Applications of Pneumatics and Hydraulics

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

B L A C K H A L L. larner-johnsonvalve presentation

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Wet pipe low flow foam/water system

Guidelines for Clean Agent Fire Suppression Systems

MEDICAL EQUIPMENT CATALOG

CAPITAL CONTROLS SERIES NXT3000

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

HORIZONTAL BLADDER TANK

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

FIREX200 CLEAN AGENT FIRE SUPPRESSION SYSTEM

OBSOLETE. Wet pipe low flow manifold system

BLAST-IT-ALL. TOLL FREE: (800)

VERTICAL BLADDER TANK

TECHNICAL DATA. Trimpac 257a. September 16, 2013

LNG TANDEM OFFLOADING A KEY ENABLING TECHNOLOGY TO MAKE LNG PRODUCTION OFFSHORE HAPPEN

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Government of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE

Horizontal Bladder Tanks

Choosing the right miniature instrument and control valve is a snap

Model MTB-ASME Horizontal Bladder Tanks

Vertical Bladder Tanks

BacPac; A portable WaterMist fire suppression kit; designed for rapid response situations. Model: FB33

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Work Horses of the Breathing Air Industry

MSC Guidelines for Carbon Dioxide Fire Suppression Systems

2. Application This "Guidelines" applies to all ships. 3. General Requirements for the Maintenance and Inspection of Fire-protection Systems and Appli

TECHNICAL DATA. Trimpac 256a. October 31, 2013

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

MANUAL GAS MANIFOLDS

Lockout / Tag out Program

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders.

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA OBSOLETE

CHE Well Testing Package/Service:

Phuel Modular Control Units

Your safety and the safety of others are very important.

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

Installation of Ballast Water Management Systems

Energy Control. Suite 2A, 55 Frid Street Hamilton, ON L8P 4M3 office: cell:

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

Technical Bulletin 148. Comparison of Flat Panel to MiniPanel. by:

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures

TECHNICAL DATA. Q = C v P S

MEGR-1912 Instruction Manual

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems

Subject Maintenance, inspection and test of Fire-Protection Systems and Appliances on board the Panama-registered ships To whom it may concern Technic

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

Pilot Check Valve: Metal Body Type

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

Model MTB-ASME Vertical Bladder Tanks

TECHNICAL DATA. Q = C v P S

CORROSION AT THE AIR-WATER INTERFACE REMOVE THE GAS

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TSS21 Sealed Thermostatic Steam Tracer Trap

Model MTB-ASME Vertical Bladder Tanks

Data Sheet Issue A

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING

Manifolds & pressure reducing sets

Transferring and Storage

670 Series Panel-Mounted Loading Regulators

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Drass. 700 Series Surface Diving System

Description Advanced Features Typical Applications

TECHNICAL DATA. Q = C v P S

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

INSTALLATION OPERATION MAINTENANCE

LPG TANK INFORMATION An energy company that puts

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Lockout Tagout Policy

Valve test benches. Systems overview

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

Installation and maintenance of twin 45kg LPG cylinder systems

Transcription:

Effective protection thanks to the latest technology Fire protection is a top priority for any company, institution or public space. An accident of this type can irreparably affect the building, property and equipment, not to mention the toll on human lives and the business or activity itself. SIEX develops fixed extinguishing systems that use FM-200 agent, which acts effectively against fire, minimizing the impact on equipment and also providing increased safety for personnel. Thanks to an in-depth study of the needs of each enclosure, we have developed a protection technology that covers the greatest choice of working pressures on the market. The novel SIEX HC-227 S-FLOW system outperforms all traditional fixed extinguishing systems with chemicals. The system can be configured to high working pressures and therefore can be installed in a wide range of spaces and applications. The reliability of each component adapted to these new working requirements translates into one of the safest and most versatile systems in the world. SIEX HC-227 S-FLOW guarantees quick and safe fire extinguishing. Its features provide great safety and effectiveness, from installation until activation (when required).

GREATER VARIETY OF WORKING PRESSURES SIEX HC-227 S-FLOW features an innovative cylinder valve suitable for the widest range of operating pressures in the market. It also boasts the widest range of cylinder capabilities. The result is maximum adaptability of the equipment to the protected hazard, enhancing the system s design and optimizing its cost. tanks should be removed from the protected hazard or where long pipe runs are required. With SIEX HC-227 S-FLOW, design or installation constraints can be overcome thanks to its ability to work under high pressure. When it comes to protecting high-cost property or equipment in occupied areas, the traditional clean agent SIEX HC systems are the best choice. They are suitable for cases where storage It is ahead of the curve of other alternatives, offering exclusive protection. SIEX HC-227 S-FLOW WORKS AT PRESSURES OF 32, 34, 50, 55 and 60 bar. Our breakthrough system is certified by certifying bodies VdS, FM and UL for all its working pressures.

Major benefits SAFER EQUIPMENT, DESIGNED TO WORK AT HIGH PRESSURES A SINGLE STORAGE SYSTEM CAN BE USED FOR PROTECTING SEVERAL HAZARDS USE OF SELECTOR VALVES WITH MINIMUM RESTRICTIONS LONG PIPE RUNS POSSIBLE LESS COMPONENT DIAMETER LESS STORAGE SPACE REQUIRED, WHICH EQUALS GREATER AMOUNTS OF AGENT SPECIFIC HYDRAULIC CALCULATION SOFTWARE THAT OPTIMIZES THE DESIGN OF EACH SYSTEM QUALITY ASSURANCE CERTIFIED BY THE MAIN CERTIFYING BODIES UP TO 60 BAR

Installing cylinder banks close to the room protected is advisable, but it is not always possible due to lack of storage space or for aesthetic or technical considerations. Therefore, the WORKING PRESSURE is an extremely important factor that allows overcoming these obstacles. Depending on the requirements of the protected enclosures, the working pressure of the equipment is adjusted to the design constraints (pipe length, number and arrangement of cylinders, nozzles, etc.). THE INDIVIDUAL FEATURES THAT MAKE UP THE SYSTEMS COUPLED WITH THE FACT THAT WE ARE THE MANUFACTURER WITH THE GREATEST RANGE OF CYLINDER SIZES MAKES OUR EQUI- PMENT THE MOST COMPETITIVE IN THE MARKET. Applications MUSEUMS AND ART GALLERIES TELECOMMUNICATION SYSTEMS HOSPITALS PETROCHEMICAL FACILITIES COMPUTER ROOMS LABORATORIES AND CLEAN ROOMS DATA PROCESSING CENTRES (DPCS) ELECTRICAL CABINETS AND SUBSTATIONS ARCHIVES AND LIBRARIES OFFSHORE PLATFORMS OTHERS...

A UNIQUE SOLUTION THE BEST CHOICE FOR PROTECTING LARGE SPACES. A single bank of cylinders is capable of safeguarding large rooms thanks to the higher range achieved by the variety of pressures on SIEX equipment. This is therefore a highly recommended solution for protecting various spaces using a single system. In addition, the extensive coverage and maximum height of the nozzles make it unique. NO RESTRICTIONS ON THE USE OF SELECTOR VALVES Unlike other systems which simultaneously protect multiple hazards with selector valves, the advanced S-FLOW technology for adjusting pressure translates into an enhanced use of selector valves with fewer limitations. FEWER CHANGES TO ARCHITECTURAL STRUCTURES The features highlighted above also translate into less impact on the building itself. With the S-FLOW system, a single cylinder bank helps protect the entire building, providing structural and aesthetic benefits and requiring less storage space.

OPTIMIZATION OR PIPEWORK SYSTEM S-FLOW achieves a significant improvement in the installation of piping, allowing the use of smaller diameters and longer runs to reach remote hazards. The design is optimized thanks to SIEX s specific software, the only valid tool for proper design. SAFER HANDLING The suitability of each of the components fpr higher working pressures results in greater strength. The strength of the equipment ensures safe handling during installation and maintenance with maximum effectiveness. Breakthrough for the protection of large hazards

RELEASE METHOD SIEX HC-227 S-FLOW works by total flooding, which is why the protected enclosure must be completely watertight. The discharge of the design concentration and its hold time for the minimum period necessary ensures fire extinguishing and prevents its re-ignition. personnel who might be in the room and avoid equipment damage, increasing safety. The system acts in the early stages of the fire, preventing its spread and minimizing damage. The discharge is very safe, relatively quiet and does not reduce visibility. These features facilitate the evacuation of The scattering of the agent occurs within a maximum of 10 seconds, which means minimal impact on the room. Having a backup system is advisable to ensure protection during charging and/or re-stamping of the main system, and when the system covers several areas via selector valves. A backup system can be extremely beneficial to ensure the safety of the facility. The backup system will have the same quantity of gas for protecting the enclosure as was calculated for the main system. When uninterrupted protection is required, both the main and backup agent supply systems must be permanently connected to the distribution piping and arranged in such a way as to make the switch as easy as possible.

COMPONENTS CYLINDERS The widest range of storage volumes in the market. Thanks to the S-FLOW valve, the system can operate at pressures of 32, 34, 50, 55 and 60 bar. This allows maximum design flexibility for these systems. CYLINDERS CAPACITY (L) 6 13 26 40 67 80 100 120 150 180 240 368 451 514 * 2 and 4.7 litre bottles are available in SIEX SMS Much greater distance possible from storage to the hazard. CYLINDERS CAPACITY (Ib) 15 30 65 100 165 195 255 300 375 455 610 930 1140 1300 * 5 y 11.9 Ibs bottles are available in SIEX SMS * Orientative capacities extinguishing agent DuPont FM-200, a colourless, odourless and non-conductive agent. Under normal conditions it s gaseous state ensures high scattering capacity. It is a clean chemical gas (heptafluoropropane) which is stored in liquid state, thus requiring reduced storage space. Its conversion to vapour occurs easily in the pipework once the cylinder has been actuated, and it is discharged in gaseous form. It extinguishes the fire by physical and chemical means, weakening it by heat absorption until it disappears. Suitable for occupied areas Harmless to the ozone layer Electrically non-conductive Clean, leaves no residue High extinguishing capability

Specially created for high pressures CYLINDER VALVES SIEX has the greatest range of cylinder valve sizes, make it suitable for any hazard through optimal configuration. Its components ensure reliable and safe operation at high pressures, for which the system has been approved. It can be installed with large cylinders, ensuring a 10 discharge time, as required by law. SHUT-OFF VALVES with electric signal Our shut-off valves provide the system with an additional safety element, making it possible to maintenance the cylinders and prevent accidental discharge. We offer a wide range of activation elements, including electrical, pyrotechnic, manual, pneumatic or manual pneumatic. A mechanical remote manual activation handle can also be added. SELECTOR VALVES When there are two or more independent hazards together, they can be protected with a single set of storage cylinders thanks to the use of directional valves. The cylinder bank sized for the most unfavourable hazard is sufficient for protecting the rest of them. This translates into a huge installation savings. In-line check VALVES These valves must be installed in arrangements featuring a main plus a backup bank. They ensure proper operation and prevent component damage, by using the same discharge manifolds.

NOZZLES The design ensures that the agent is discharged uniformly and as required in the areas to be protected (main room, false floor or ceiling, etc.). Both features are possible due to the joint and suitable design of the required piping system, nozzles and calibrated orifices. A 100% effective and homogeneous discharge is guaranteed. The nozzles are selected depending on the enclosure needs. SIEX s wide range of high-pressure nozzle sizes completes its innovative S-FLOW system. Thanks to their advanced design, the number of nozzles can vary according to the aesthetic and functional requirements of the room. They boast the greatest coverage (13.2 x 13.2 m) and maximum height available in the market, which allows optimizing system design. CHECKING THE AGENT FILL CONTINUOUS WEIGHING The fire panel is alerted of any loss in cylinder agent. It is a simple, standardized system which is easy to install and also allows visual inspection. It does not remain in contact with the agent, so there is no risk of leakage. PRESSURE SWITCH A pressure switch can be assembled on the SIEX HC- 227 S-FLOW cylinder valve which can be handled with the pressurized cylinder. This device controls the internal pressure, sending a signal to the fire panel in case of failure. GAUGE WITH ELECTRICAL CONTACTS This combination of gauge and pressure switch enables visually checking the pressure and also sends a notice to the fire panel in the event of any change in the cylinders. For checking the correct activation, SIEX HC-227 Range of nozzles made of stainless stell, brass, aluminium or crome-plated steel. S-FLOW includes: pressure switch Installed in the bank manifold or in the piping system, it allows discharge confirmation. Other components that may be added to the system to increase the safety of personnel in the discharge areas are as follows: PNEUMATIC RETARDANTS, PNEUMATIC SIRENS, RELIEF VALVES, DECOMPRESSION VALVES AND ODORIZERS. SIEX S-FLOW has FLAMEPROOF components for the petrochemical industry.

SIEX C. Merindad de Montija nº 6 P.I. Villalonquéjar 09001 Burgos (SPAIN) TLFNO: +34 947 28 11 08 WEB: WWW.SIEX2001.COM SIEX is a registered trademark. FM-200 is a registered trademark by DuPont. The information provided in this document is for information purposes only. Technical information must be used for the installation of all SIEX systems. SIEX assumes no liability for any use that third parties may make of this information. SIEX reserves the right to make any change in both the capabilities and features of its equipment.