Variable Temperature Storage Dewar Mount Inserts

Similar documents
CRYO. SuperVariTemp Magnet Inserts

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

Microscopy Cryogenic WORKSTATION. Performance by Design

CRYO INDUSTRIES. Liquid Helium Research Dewars

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

Baffles and Traps Cryotrap

Current Leads for Cryogenic Systems

Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System. Dwg. No

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1

attoliquid Liquid Research Cryostats

Table of Contents Want full page pictures with most important parts labeled in the beginning.

Liquid Helium Bath Cryostat

Storage and transfer of cryofluids

Magnet and RF Cavity Test Stand Design. Tom Peterson, SLAC USPAS January, 2017

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

SPECIFICATION FOR AN MRBR 9.4 TESLA/310MM/AS CRYO-COOLED MAGNET SYSTEM

HighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

First Experimental Data of the Cryogenic Safety Test Facility PICARD

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Cryogenics of SRF Spoke Cavity Development at SMTF

Section 3- Repair and Calibration Procedures

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

PVQ 13 A2 R SE 1 S 20 C-11 D

Dilution Refrigerator manual

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Constant Pressure Crude Oil Container Model CPCCP

Judson Technologies PB 219. JTC JOULE-THOMSON CRYOSTAT COOLING SYSTEM Operating Instructions. October, 2003

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler

Thanks for choosing EJAI SOLAR product

Quantitative study of sniffer leak rate and pressure drop leak rate of liquid nitrogen panels of SST-1 tokamak

Use equation for the cylindrical section and equation or for the ends.

Pump out insert (condenser and still lines) overnight with turbo pump

SAILTEC, INC CONGER COURT, OSHKOSH, WI USA

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Bruker BioSpin NMR CASE. System Requirements Manual. Version. NMR Spectroscopy. think forward

Residual Gas Analysis Systems for Industry

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

Tank Blanketing Pressure Regulators RHPS Series

VACUUM REGULATORS CONTENTS

High Va. High Vacuum Pumps. COOLVAC Cryo Pumps COOLPOWER Cold Heads COOLPAK Compressor Units

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Major Design Features

ALF400 to 900, ALT-5/-9

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Customer Responsibilities

TELEDYNE PB 219. JUDSON TECHNOLOGIES A Teledyne Technologies Company TELEDYNE JUDSON TECHNOLOGIES JTC JOULE-THOMSON CRYOSTAT COOLING SYSTEM

Oxford Instruments Austin, Inc.

Air Operated Hydraulic Pumping Systems to 50,000 psi

Hand lever valves VHER

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Precision and Instrument Regulators 1/4" port size

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

GM Series Dual-Block Multi-Function Gas Control Valves

REFRIGERATION SYSTEM COMPONENTS

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

LMU100/200 Series. Standard Specifications

Pneumatic spool valve islands

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

VACGEN. Vacuum Components. Product Overview

Customer Responsibilities

Flow control valves Series RFU - RFO 2/

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

Float valves Types SV 4, SV 5 and SV 6

Pilot Assembly Replacement Manual Parts Needed: Phillips head screwdriver #2 Two Adjustable Crescent Wrenches Replacement Pilot Assembly

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

COMPRESSION TUBE FITTINGS

PRO SINK -R 1 and 2. Dilution system CONTENTS

Draught Academy. Name. Date _

PXRF- Tracer Helium Flow Control System

CATALOGUE // The Fort Vale Range of Equipment to suit Hydrogen Peroxide Tank Specification. Fort Vale Engineering Ltd. 2009

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Automatic Twin Greasing System

Installation Instructions

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

MEDICAL EQUIPMENT CATALOG

EXERCISE 2: THE VACUUM SYSTEM

V43 Pressure Actuated Water Regulating Valve

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

F l o w c o n T R o l v a l v E S

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

World Area Differences Technical Information

OPERATING INSTRUCTIONS

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

MagneticTurbo TM. TurboDrag pumps with pumping speed up to 1500 l/s TMH/U 1000 M / TMH/U 1600 M. Pumping speed. Start / Chapter content

Capacity regulator (hot gas bypass)

Laboratory Flowmeters

CSA Sample Draw Aspirator Adapter Operator s Manual

Heliox TM. He systems to suit all applications

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Expert Hydrostatic Level Transmitters

Armatures for analytical probes

Transcription:

Variable Temperature Storage Dewar Mount Inserts All inserts are available for either Liquid Helium or Liquid Nitrogen Dewars! DStat - External cryostat with insert leg DStatMag - Super Conducting Magnet VTC - Variable Temperature Computerized Insert Exchange Gas - 1-wall or 2-wall option SM - Storage Mount Inserts SVT - SuperVariTemp for use in large dewars or with a superconducting magnet HE3- Uses Helium 3 for ultra low cooling

DStat Directly Cooled Cryostat System The Dstat is a versatile storage dewar insert (leg is in the dewar and cryostat sits outside on top of the storage dewar) with top loading variable temperature sample in helium vapor (except for the DStat Magnet model, which is sample in static exchange gas). One of the unique features of the Cryo Industries DSTAT is that this style of insert allows for large sample tube sizes, since the sample zone is outside on top of the dewar and therefore size is not restricted by the dewar neck I.D.. The standard DSTAT SM-2243-DC has a 2.00 sample tube and is very efficient. Cool down losses will depend on the added masses, but should be approximately 0.75 liters of liquid helium for initial cooldown without any added masses. The temperature stability is very good at +/- 0.001K from 6K to 300K. The sample tube may be filled with LHe to also provide exact LHe temperature. All DStat designs offer an exchange gas insert option that fits inside the DStats sample tube to give ultimate temperature stability. The sample would then sit inside the removable static exchange gas tube. The DStat with the exchange gas sample tube has approximately 0.25 smaller diameter than DStats flowing vapor sample tube. The vibrational levels of LHe cryostats are always very low. In general vibration is not an issue with LHe cryostat systems. In a LHe sample in vapor flow cryostat (like a DStat) any vibration present in the cryostat would come from the dynamic flow as it flows over the sample and the amount of vibration is controlled by how the sample holder hangs and is held concentric in the sample tube. This Versatile Design Fits Any Storage Dewar! The DStat is available with a superconducting magnet integrated into the design! Dstat Insert in LHe Tank DStat Specifications Efficiency: One Button Operation: Versatility: Operating Temperature Range: Temperature Stable: 0.02 l/hr static LHe loss rate ~0.10 l/hr LHe operational Change temperature using the heater only or Computerized Flow Control (Optional) Fits any storage dewar (0.5 inch or 12 mm insert leg) Top Loading easy sample change Exchange samples in seconds Standard DStat : <1.4 K to 325 K (500 K optional) Magnet DStat : 4.2 K to 325 K (500 K optional) +/- 0.001 K - 4.2 K to 325 K +/- 0.010 K - 1.4 to 4.2 K

Directly Cooled DStat Drawing (1) 19 PIN ELEC. FEEDTHROUGH NW50 QUICK CONNECT FOR SAMPLE ACCESS SAFETY PRESSURE RELIEF (1) 10 PIN ELEC. FEEDTHROUGH (2) BLANK ELEC. FEEDTHROUGHS PORTS VAPOR PUMPING PORT WITH NW40 FLANGE EVACUATION VALVE WITH NW25 FLANGE PROVISION FOR T/C GAUGE 15.75 12.00 Or To Customer Specs SAFETY PRESSURE RELIEF 3.00 O.D. ELECTRICAL FEEDTHRU FOR VAPORIZER HEATER AND CONTROL SENSOR 2.00 O.D. [49 mm I.D.] SAMPLE TUBE VAPOR COOLED RADIATION SHIELD 1.50 COPPER SAMPLE MOUNT WITH PROVISON FOR TEMPERATURE (8) #4-40 TAPPED HOLES FOR ATTACHING SAMPLE HOLDERS COPPER VAPORIZER WITH 25 OHM HEATER AND SILICON DIODE CONTROL SENSOR VALVE CONTROL KNOB 1.47 SLIDING SEAL WITH 2.5" LADISH FLANGE 0.75 O.D. STORAGE DEWAR INSERT LEG 48.0 OR AS DESIRED HELIUM TRANSFER LINE ACTIVATED CHARCOAL PUMP LIQUID HELIUM FLOW VALVE WITH FILTER PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF OF AMERICA, INC. 11124 S WILLOW STREETMANCHESTER TITLE: N.H. 03103. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF IS STRICTLY PROHIBITED of America Inc. 11124 S. Willow St., Manchester N.H. 03103 VARIABLE TEMPERATURE STORAGE DEWAR INSERT

Directly Cooled DStat Magnet Insert Drawing SAMPLE AJDUSTER (LINEAR & ROTATABLE) (2) 10 PIN ELECTRICAL FEEDTHROUGHS NW25 QUICK CONNECT FOR SAMPLE ACCESS EXCHANGE GAS HEADER WITH 3-WAY VALVE, PRESSURE RELIEF AND COMPOUND PRESSURE GAUGE 3.00 2.75 HTS (HIGH TEMPERATURE SUPERCONDUCTOR) CURRENT LEADS VAPOR PUMPING PORT WITH NW40 FLANGE COMPOUND PRESSURE GAUGE 3.00 O.D. ELECTRICAL FEEDTHRU FOR VAPORIZER HEATER AND CONTROL SENSOR 15.75 EVACUATION VALVE WITH NW25 FLANGE SUPERCONDUCTING MAGNET VAPOR COOLED RADIATION SHIELD 2.00 O.D. [49 mm I.D.] FLOWING VAPOR REGION.75 O.D. [0.71 I.D., 18 mm] STATIC EXCHANGE GAS SAMPLE ZONE COPPER SAMPLE MOUNT WITH TEMPERATURE SENSOR (1) 1/4-28 TAP ON CENTER FOR ATTACHING SAMPLE HOLDERS 2.13 1.60 COPPER VAPORIZER WITH 25 OHM HEATER AND SILICON DIODE CONTROL SENSOR VALVE CONTROL KNOB SLIDING SEAL WITH DEWAR FLANGE ADAPTER 0.75 O.D. STORAGE DEWAR INSERT LEG 48.0 OR AS DESIRED HELIUM TRANSFER LINE ACTIVATED CHARCOAL PUMP LIQUID HELIUM FLOW VALVE WITH FILTER PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF OF AMERICA, INC. 11124 S WILLOW STREETMANCHESTER N.H. 03103. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF IS STRICTLY PROHIBITED of America Inc. 11124 S. Willow St., Manchester N.H. 03103 WWW..COM TITLE: VARIABLE TEMPERATURE STORAGE DEWAR INSERT WITH SUPERCONDUCTING MAGNET

Variable Temperature Computerized Insert (VTC) The Variable Temperature Computerized Insert is a top loading sample in vapor variable temperature cryostat. It fits standard 1.4 inch neck diameter (1.5 O.D.) storage dewars, 30, 60 or 100 liters. How do we do it? a. Universal slide seal adjusts height for proper fit. b. Electronic flow valve allows fitting into smaller access. c. Impedance flow line allows pumping the sample zone to <2K. Typical dimensions: Sample Tube Diameter = 0.75 O.D. (0.71 I.D. [18mm]). Maximum O.D. = 1.38. Operating Range = <2 to 300K. Insert length = 32 to 40 (adjustable). Available in a more compact version with O.D. of 1.13 and 0.5 O.D. (0.46 I.D.) sample tube. Available with superconducting coil installed! Sample in Exchange Gas Insert (SXG) The Sample in Exchange Gas Insert is a useful tool for experiments where flowing vapor may be undesirable, such as Mossbauer or infrared detectors. Samples are top loading and cooled by thermal interface to the reservoir using static exchange gas. The temperature of the sample can be varied by adjusting the exchange gas pressure and the power dissipated in the sample mount heater. Temperature range is <5 K to 300 K. or with dual tubes- two wall insert where cooling and thermal resistance are controlled by dual exchange gas regions. This insert can be used in conjunction with a superconducting magnet. The Sample in Exchange Gas Insert is available in a single tube (wall) insert

Variable Temperature Computerized VTC Drawing 19 PIN ELECTRICAL FEEDTHROUGH SAFETY PRESSURE RELIEF EVACUATION VALVE WITH NW25 FLANGE PUMPING PORT WITH NW25 FLANGE SAFETY PRESSURE RELIEF 19 PIN ELECTRICAL FEEDTHROUGH 4.25 10 PIN MALE INLET AND OUTLET CURRENT LEADS 2.63 HEIGHT ADJUSTABLE O-RING SEAL 4.25 QUICK CONNECT WITH NW50 FLANGE ADAPTER TO MAGNET DEWAR 1.75 0.D. 18.00 33.15 46.00 1.00 O.D. He COUNTER FLOW HEAT EXCHANGER REUSABLE SEAL 0.50 O.D. FIXED IMPEDANCE INLET.625 JOINT OVERLAP 6.22 1.75 O.D. VACUUM SHROUD REMOVABLE FOR SAMPLE ACCESS.50 1.0 INCH DIAMETER COPPER SAMPLE MOUNT WITH M3 TAPS, HEATER AND TEMPERATURE SENSOR.80 3.43 1.90 Ø.787 Ø.375 M8 THREAD, FOR FULL HEX NUT of America Inc. 11124 S. Willow St., Manchester N.H. 03103 PROPRIETARY INFORMATION TITLE: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF OF AMERICA, INC., 11124 S WILLOW STREET MANCHESTER, N.H. 03103. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF IS STRICTLY PROHIBITED VTI He4 MAGNET INSERT SAMPLE IN VACUUM

Sample in Exchange Gas Insert Drawing SAMPLE POSITIONER ADJUSTER NW40 QUICKONNECT FLANGE (2) 10-PIN ELEC. FEEDTHROUGHS.20 SAFETY PRESSURE RELIEF EXCHANGE GAS VALVE WITH 0.37 DIA. TUBE ADAPTER AND NW25 ADAPTER 2.00.20 2.00 3-WAY EXCHANGE GAS VALVE WITH 0.37 DIA. TUBE ADAPTER AND NW25 FLANGE " LADISH FLANGE (3.047 ACTUAL O.D.) 3.50 35.00 OR AS NEEDED 1.75 O.D. TUBE 1.50 O.D. TUBE CONCENTRICITY SPACER COPPER SAMPLE MOUNT WITH HEATER, PROVISION FOR TEMP. SENSOR AND (8) #4-40 TAPPED HOLES FOR MOUNTING.75 CONCENTRICITY SPACER Industries of America Inc. 11124 South Willow Street, Manchester NH 03103 TITLE: VARIABLE TEMPERATURE TWO-WALL EXCHANGE GAS INSERT

Storage Mount (SM) Insert The sample in vapor variable temperature Storage Mount Insert fits into standard storage dewars with 2 inch diameter necks and provide variable temperatures from <1.5 K to 300 K. Samples are cooled by insertion into flowing helium gas exiting from the vaporizer (also known as the diffuser or heat exchanger). A small amount of liquid helium is drawn from the storage dewar reservoir into the vaporizer located at the bottom of the sample tube. The helium is vaporized and heated to your pre-selected temperature. The gas enters the sample zone flowing past the sample. The sample is cooled to the temperature of the gas. Standard sample tube size is 0.75 inches (19.1 mm) O.D. The I.D. is.71 inches (18.0 mm). Optional 1.0 inch (25.4 mm) O.D. is available. Custom fit as required - choice of Super VariTemp Length and style of quick connect adapter for storage dewar attachment. SuperVariTemp (SVT) Magnet Insert The SuperVariTemp Magnet (SVT) cryostat is available as an insert, built-in or as magnet support combo. This cryostat offers ultra stable temperature and high refrigeration capacity. It is available with standard solenoids to 9 Tesla at 4.2 K or 11 Tesla at 2.2K, high field magnets to 17 Tesla. This versatile cryostat offers an optional vapor shield for extended high temperature operation. Inserts can be custom fitted to your existing system! Left photo shows magent support with seperate insert, right photo shows the insert. He3 Insert He3 Inserts provide operating temperatures from less than 0.3 to 300 K. The He-3 Insert is available as either sample in vacuum or top loading into vapor/liquid. Ask for complete HE3 System Brochure.

Storage Mount (SM) Insert Drawing SAMPLE POSITION ADJUSTER LINEAR AND ROTATABLE EVACUATION VALVE WITH NW25 FLANGE, SAFETY PRESSURE RELIEF AND 10 PIN ELECTRICAL FEEDTHROUGH FOR VAPORIZER HEATER & CONTROL SENSOR SAMPLE POSITIONER ASSEMBLY WITH (2) 10 PIN ELECTRICAL FEEDTHROUGHS SAFETY PRESSURE RELIEF FLOW VALVE OPERATOR NW40 FLANGES FOR SAMPLE ACCESS VAPOR PUMPING PORT WITH NW25 FLANGE 3.75 QUICK CONNECT FLANGE FOR STORAGE DEWAR ATTACHMENT (2) REMOVABLE AND ADJUSTABLE LOCATION RADIATION BAFFLES AS DESIRED 1.25 0.D. 0.75 O.D. SAMPLE TUBE (1.00 O.D. OPTIONAL) He FLOW VALVE WITH FILTER COPPER SAMPLE MOUNT WITH HEATER, PROVISON FOR TEMPERATURE SENSOR AND 1/4-28 TAP ON CENTER FOR ATTACHING SAMPLE HOLDERS (M6-1 TAPPED HOLE OPTIONAL) 2.41 1.50 COPPER VAPORIZER WITH HEATER AND PROVISION FOR SENSOR 1.88 O.D. PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF OF AMERICA, INC. 11124 S WILLOW STREETMANCHESTER N.H. 03103. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF IS STRICTLY PROHIBITED of America Inc. 11124 S. Willow St., Manchester N.H. 03103 TITLE: VARIABLE TEMPERATURE STORAGE DEWAR INSERT

Super Vari Temp (SVT) Magnet Insert Drawing SAMPLE POSITION ADJUSTER (2) 10 PIN ELECTRICAL FEEDTHROUGHS SAFETY PRESSURE RELIEF FLOW VALVE OPERATOR ISO NW 40 FLANGE ISO NW 25 VAPOR PUMPING PORT 0.2 (1) 10 PIN ELECTRICAL FEEDTHROUGH INSERT EVACUATION VALVE WITH SAFETY PRESSURE RELIEF 4.87 DIA. 3.50 TOP VIEW 5.50 (6) CLEARANCE HOLES FOR #10-32 SCREWS EQUALLY SPACED ON A 4.50 DIA. BOLT CIRCLE 4.00 (4) COPPER RADIATION BAFFLES WITH WIREWAYS 2.00 1.00 3.50 DIA. 2.00 O.D. 1.50 O.D. 45.00 He FLOW VALVE WITH FILTER 1.37 3.50 O.D. CRUSHED INDIUM SEAL 1.50 8.25 3.75 COPPER VAPORIZER WITH 50 OHM HEATER, PROVISION FOR TEMPERATURE SENSORS AND CONCENTRICITY SPACER 2.00 O.D. SUPERCONDUCTING MAGNET CONCENTRICITY SPACER COPPER SAMPLE MOUNT WITH 50 OHM HEATER, PROVISION FOR TEMPERATURE SENSORS AND (4) #4-40 TAPPED HOLES FOR SAMPLE MOUNTING PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF OF AMERICA, INC., 11124 S WILLOW STREET MANCHESTER, N.H. 03103. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF IS STRICTLY PROHIBITED of America Inc. 11124 S. Willow St., Manchester N.H. 03103 WWW..COM TITLE: VARIABLE TEMPERATURE MAGNET INSERT