Halsey Taylor Owners Manual

Similar documents
Halsey Taylor Owners Manual

Halsey Taylor Owners Manual

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

Owners Manual. Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual STOP!

Owners Manual Models 4430BF3, 4430BF2 & 4430BF1 Floor Mounted Tri-Level Bottle Filling Tubular Fountain

Installation/Care/Use Manual

PAGE (Rev. A - 06/17)

Installation and Use Manual

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

LK4420BFFR - FTN, 4420BFFR - FTN. Owners Manual

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

UltRo Dual Flow Reverse Osmosis Water System

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

Medical Gas Control Panel

Pressure Dump Valve Service Kit for Series 2300 Units

Speed control assembly model A-1

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Multi-Probe Sampling System User Guide & Manual

VOLUMATIC WATER REGULATOR

Pressure Dump Valve Service Kit for Series 3000 Units

INSTALLATION and OPERATION INSTRUCTIONS

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

Floor Drinking Systems

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

SIMPLAIR PIPING TOOL. JXT Company

D05 Pressure Regulating Valves

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

SEAGULL IV X-1F Drinking Water Purification System

RD(H)20/25 Pressure-Reducing Regulator User Manual

DS05C,D,G Dial Set Pressure Regulating Valves

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

Pressure Balance Trim

INSTALLATION AND SERVICE MANUAL FOR LANCER DISPENSING TOWERS

TECHNICAL DATA CAUTION

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

LEAK TROUBLESHOOTING

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Anti-flood device Model B-1

AIR/OVER HYDRAULIC JACK 20 TON

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Booster Pump PB4-60 Replacement Kits

Float Operated Level Controllers

Installation Instructions

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

Service and Repair Manual

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

VOLUMATIC WATER REGULATOR

LRS(H)4 Pressure-Reducing Regulator User Manual

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

2.5 & 5.0 GALLON PRESSURE TANKS

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

2.0 INSTALLATION & SERVICE

TECHNICAL DATA. Page 1 of 12

D05T Compact Design Pressure Regulating Valves

INSTALLATION INSTRUCTIONS

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

Operating Instructions Models and Hydrostatic Test Pumps

Operation Manual Air Saver Unit ASV5000 Series

Propane Conversion Kit Instructions

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

DS06D,G Dial Set Pressure Regulating Valve

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Installation Troubleshooting Maintenance Instructions Installation / Start-up

DelVal Flow Controls Private limited

FLUSHMATE FLUSHOMETER - TANK SYSTEM

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

CO2 Tank Conversion Kit P.N , P.N , and P.N

Code AWC20HP Air Compressor

Constant Pressure Crude Oil Container Model CPCCP

TECHNICAL DATA CAUTION

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

THE KEENEY MANUFACTURING COMPANY

4400 TwinHybrid Gas Seal

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Chloramines Removal Filter CLF20 and CLF35 Models

Operation Manual Guillotine Cutter RC-5

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Installation, Operation and Maintenance Manual for Back Pressure Regulator

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

GREIG FILTERS, INC. OPERATION MANUAL

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

Transcription:

Halsey Taylor Owners Manual Wall Mount Steel Refrigerated Fountains INSTALLER These series fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future reference. IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT! INSTALLER PLEASE NOTE. THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREAT- ING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. OPERATION OF QUICK CONNECT FITTINGS Simply Push In Tube To Attach Tube Is Secured In Position Push In Collet To Release Tube 1/4" O.D. TUBE WATER INLET TO COOLER 3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY BUILDING WATER INLET A B C NOTE: WATER FLOW Pushing Tube In Before DIRECTION Pulling It Out Helps To FIG. 1 Release Tube. FIG. 2 Page 1 SERVICE STOP (NOT FURNISHED) 97087C (Rev. D - 3/01)

HT - ER/SR/SER/ESR COOLER INSTALLATION 1. Install remote chiller. Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and side panel. Slide chiller onto the shelf and position it to the left within the guides on the shelf. NOTE: Building construction must allow for adequate air flow on both sides, top, and back of chiller. A minimum of 4" (102mm) on both sides and top is required. See chiller instructions for additional instructions. 2. Make water supply connections. Attach a water inlet line and a service stop (not provided) to the chiller. Inlet port is marked on the chiller (3/8" O.D. copper tube). Bend the copper tube (provided) at an appropriate length from chiller to opening in frame. Install a 3/8" O.D. tube tee fitting (provided) on the marked chiller outlet port. Turn on the water supply and flush the line thoroughly. 3. Hang the upper panel on the mounting frame hanger. Align holes in the panel with the holes in the mounting frame. Be sure that panel is engaged with hanger at top of frame before releasing it. 4. Install fountains. Remove access cover plates on underside of fountains and save the screws. Mount the fountains to the upper panel and the wall frame with (4) 5/16" x 3/4" (19mm) long bolts and nuts (provided). Tighten securely. NOTE (HT-SER ONLY): The short fountain should be mounted to the upper left hand side of the panel. 5. Cut waste tubes to required lengths using plumbing hardware and trap (not provided) as a guide. Install hardware and traps. Tighten securely. 6. Make connection between remote chiller outlet tube and fountain strainer. Insert the water inlet line into inlet side of strainer by pushing it in until it reaches a positive stop, approximately 3/4" (19mm). DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT. 7. Open service valve and operate the fountain valves to purge air from the system. Check thoroughly for leaks. 8. These products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above 105 PSIG, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting these products to supply line pressures lower than 20 PSIG or higher than 105 PSIG is not covered by warranty. 9. Make electrical connections to the chiller. See chiller instructions. 10. Check stream height from bubbler. Stream height is factory set at 45-50 PSI. If supply pressure varies greatly from this, adjust the screw on regulator (Item 13 on page 7). Clockwise adjustment will raise stream height and counter-clockwise adjustment will lower stream height. For best adjustment stream height should be approximately 1-1/2" (38mm) above the bubbler guard. (See Figure 8) 11. Water Valve Mechanism - ADJUSTMENT PROCEDURE: - Turn adjustment screw on page 7 Counter-Clockwise until water flow from bubbler starts. - Turn adjustment screw Clockwise until water flow stops, then turn an additional 1/2 turn. 12. Mount lower panel. Loosen the (2) #10-24 x 5/8" (16mm) screws at frame bottom lip. Slide upper tongue of lower panel under lower edge of already installed upper panel. Tighten previously loosened screws securely. 13. Replace bottom access panels to fountain basins using screws provided. Tighten securely. 97087C (Rev. D - 3/01) Page 2

LEGEND: A = 3/8 O.D UNPLATED COPPER TUBE CONNECT (CHILLER WATER OUTLET) B = 3/8 O.D. UNPLATED COPPER TUBE CONNECT (CHILLER WATER INLET) SHUT OFF VALVE BY OTHERS C = 1-1/4 O.D WASTE TUBE (ELBOW AND TRAP NOT PROVIDED) D = ELECTRICAL INLET Fig. 3 Page 3 97087C (Rev. D - 3/01)

LEGEND: A = 3/8 O.D UNPLATED COPPER TUBE CONNECT (CHILLER WATER OUTLET) B = 3/8 O.D. UNPLATED COPPER TUBE CONNECT (CHILLER WATER INLET) SHUT OFF VALVE BY OTHERS C = 1-1/4 O.D WASTE TUBE (ELBOW AND TRAP NOT PROVIDED) D = ELECTRICAL INLET Fig. 4 97087C (Rev. D - 3/01) Page 4

LEGEND: A = 3/8 O.D UNPLATED COPPER TUBE CONNECT (CHILLER WATER OUTLET) B = 3/8 O.D. UNPLATED COPPER TUBE CONNECT (CHILLER WATER INLET) SHUT OFF VALVE BY OTHERS C = 1-1/4 O.D WASTE TUBE (ELBOW AND TRAP NOT PROVIDED) D = ELECTRICAL INLET Fig. 5 Page 5 97087C (Rev. D - 3/01)

LEGEND: A = 3/8 O.D UNPLATED COPPER TUBE CONNECT (CHILLER WATER OUTLET) B = 3/8 O.D. UNPLATED COPPER TUBE CONNECT (CHILLER WATER INLET) SHUT OFF VALVE BY OTHERS C = 1-1/4 O.D WASTE TUBE (ELBOW AND TRAP NOT PROVIDED) D = ELECTRICAL INLET Fig. 6 97087C (Rev. D - 3/01) Page 6

Fig. 7 ITEMIZED PARTS LIST TO BUBBLER 18 CHILLER OUTLET 15 16 CHILLER INLET NOTE: SEE PAGE 8 FOR PART NUMBERS TO BUBBLER TO BUBBLER ITEM NO. PART NO. DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 26936C 26935C 27237C 75517C 70378C 75555C 70856C 55859C 101514331640 111411743620 40045C 15005C 61313C 50986C 50198C 55899C 27073C Push Lever Assy Mounting Bracket Assy Bracket - Pushbar Lever Rod Pushbar Rod Spring Clip Screw - #10-24 x.38 PHMS Pushbar - Side & Front Pushbar Insert Nut - 1/4, Self Thread Regulator Hex Nut Regulator Retaining Nut Regulator Regulator Holder Snap Bushing Pad - Window Filler Backing Plate HT - ER / SR TUBE ROUTING 17 15 CHILLER OUTLET 16 CHILLER INLET Fig. 9 HT - SER / ESR TUBE ROUTING Fig. 8 Page 7 97087C (Rev. D - 3/01)

ITEMIZED PARTS LIST ITEM NO. PART NO. DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 NS 51546C 45397C 66318C 10080C 100322740560 160270508640 410270508450 161637308640 411637308450 100147140560 66346C 66343C 26868C 26869C 26870C 26871C 23001C 23002C 26837C 26838C 26835C 26836C 26839C 26840C 27028C 27260C 26833C 26834C 27026C 27027C 55884C 75588C 55996C 70745C 70852C 70870C 75589C 70055C HT - ER*D HT - SR*D HT - SER*J HT - ESR*J Bubbler - Satin Bubbler - Golden Bronzetone Tube Assy - Bubbler Nipple - Bubbler (Included w/item 2) Gasket - Bubbler (2-Reg d) Strainer Plate Strainer Plate - Golden Bronzetone Drain Plug Drain Plug - Golden Bronztone Gasket - Drain Tube - Waste (HT-ER) Tube - Waste (HT-SR) Basin - Stainless Steel (HT-ER) Basin - Golden Bronzetone (HT-ER) Basin - Stainless Steel (HT-SR) Basin - Golden Bronzetone (HT-SR) Cover - Bottom (HT-ER) Cover - Bottom (HT-SR) Upper Panel - Stainless Steel (HT-ER) Upper Panel - Golden Bronzetone (HT-ER) Upper Panel - Stainless Steel (HT-SR) Upper Panel - Golden Bronzetone (HT-SR) Upper Panel - Stainless Steel (HT-SER) Upper Panel - Golden Bronzetone (HT-SER) Upper Panel - Stainless Steel (HT-ESR) Upper Panel - Golden Bronzetone (HT-ESR) Lower Panel -Stainless Steel (HT-ER/SR) Lower Panel - Golden Bronzetone (HT-ER/SR) Lower Panel -Stainless Steel (HT-ESR/SER) Lower Panel - Golden Bronzetone (HT-ESR/SER) Elbow - Drain Nut 1-1/4 Slip Joint Strainer (See Page 7, Fig. 9) Union - 3/8 x 1/4 Tube (See Page 7, Fig. 9) Tee - 3/8 (See Page 7, Fig. 9) Union - 3/8 (See Page 7, Fig. 9) Gasket Nut - Speed TROUBLE SHOOTING & MAINTENANCE Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file not over 1/8" diameter or small diameter wire. CAUTION: DO NOT file or cut orifice material. Stream Regulator: If orifice is clean, regulate flow as in START UP instructions on page 2. If replacement is necessary, see parts list for correct regulator part number. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.(see Fig.1) To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4". CAUTION: Cleaning of Bronzetone Models requires special care. Outer surfaces must be cleaned with mild detergent or mixture of vinegar and water only, rinsed and wiped dry. Abrasive and acidic cleaners may eventually damage the Bronzetone finish. 2 9 4 1, 3 5, 6, 7 MODEL HT-SR SEE PUSH BAR MECHANISM (PAGE 7) 10 13 14, 19 8 1, 3 11 2 4 5, 6, 7 12 9 MODEL HT-ER SEE PUSH BAR MECHANISM (PAGE 7) 10 13 14, 19 8 11 2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.3500 12 PRINTED IN U.S.A. FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 97087C (Rev. D - 3/01) Page 8