SPECIFICATIONS. Outdoor Tubular Bottle Filling Station Freeze Resistant Dual Station. MODEL LK4420BF1UFRK and MODEL LK4420BF1LFRK

Similar documents
Owners Manual Bottle Filler Freeze Resistant Tubular Fountain & Pet Fountain with 98837C Dual Valve Control Assembly

LK4420BFFR - FTN, 4420BFFR - FTN. Owners Manual

Owners Manual. Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain

PAGE (Rev. A - 06/17)

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Non-Refrigerated Universal Bi-Level AquaAccess Barrier Free, Wall Mounted Water Cooler

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual STOP!

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Aquor House Hydrant V2

Owners Manual Models 4430BF3, 4430BF2 & 4430BF1 Floor Mounted Tri-Level Bottle Filling Tubular Fountain

Order No Projection Backboard

Instructions for Installation, Use and Maintenance FSI Safety Tank Shower Systems

WELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

Repair Stations. Securabike. Advantages

-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM

CALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function

10.2. Basketball Single Post System

Installation and Use Manual

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist

self closing tapware and bubblers AUTOMATIC SHUT-OFF REDUCE WATER WASTE IMPROVE HYGIENE VANDAL RESISTANT Spring Action Series Time Flow Series

SEAL Enclosure Installation Instructions

ANSI Z Compliance Checklist

MEDICAL EQUIPMENT CATALOG

Pneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Skate Park Scheme Options

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Halsey Taylor Owners Manual

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

ANSI / ISEA Z Compliance Checklist

ANSI / ISEA Z Compliance Checklist

SANITIZERS SANITIZERS SANITIZERS FOR POOLS & SPAS

KOBOLD KSM FLOWMETER. User Instructions

PowerDrain Section S100K/S200K/S300K ACO DRAIN. Introduction Pgs 1-13 Selecting the right product

SIX CYLINDER RADIAL STEAM ENGINE WITH SLIDE VALVES GENERAL ARRANGEMENT IF NOT STATED ALL CHAMFERS ARE 0.2mmx45

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

Vertical Bladder Tanks

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

Sanitizer Parts. Sanitizer Parts. Replacement Parts for Sanitizers

GREIG FILTERS, INC. OPERATION MANUAL

Sanitary pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

EXCELON QUIKCLAMP SYSTEM Pressure relief valves V72G, V74G - G1/4... G 3/4

DUAL-VORTEX SEPARATOR. Inspection and Maintenance Guide

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

LIEBERT DS TOP VIEW FRONT VIEW. This document has been generated on 22 September :18 PM (EST). Dry Weight (approximate) lb.

Pre-adjustable pressure reducing valves

Design Requirements for Eyewash and Safety Shower Units

210 & 220 series gas pressure regulators for industrial applications

Installation/Care/Use Manual

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Installation Instructions for NP100 Series Nitrogen Control Panels

ALF400 to 900, ALT-5/-9

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013

10.2. Basketball Single Post System

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

Bladder-Type Accumulators

Dri-Line Mk3 Monnier Compressed Air Drain Trap

TECHNICAL DATA. Trimpac 247a_Euro. September 16, 2013

CVS10 Sanitary Check Valves

FireLock NXT Dry Valve. System No. Submitted By Spec Sect Para Location Date Approved Date FIRE PROTECTION PRODUCTS DEVICES

2.0 INSTALLATION & SERVICE

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

Horizontal Bladder Tanks

PVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

Encore PE 50-lb Feed Hopper

971 Series Pressure Reducing Regulators

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

MATRIX CONCEPTS CANADA TOLL FREE:

These products are available only in packs of 100 pieces

Industrial Regulator Series 1800/2000

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

Model: AT-1000 L.P.G. FREEZE VALVE

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

RR 16 Commercial & Industrial Regulator

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators

Pressure Reducing Valve DMV 755

Continental Industries TRANSITION FITTINGS or FAX Visit

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators

Avenger Model 33M Installation & Operation Instructions

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Football. Equipment & Flooring. 3G Stadium Goals. 3G Parks Goals. Mini Soccer Goals. Five-a-side Goals. Goalpost and Net Accessories.

MAKE BOLLARD IMPACT RESISTANT PROTECT FOUNDATIONS RE-USE BOLLARD

Floor Drinking Systems

Halsey Taylor Owners Manual

Model MTB-ASME Vertical Bladder Tanks

JR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

Advantage Lockers & Bike

Transcription:

SPECIICTIONS MODEL LK44201URK and MODEL LK44201LRK ENERL Steel Outdoor reeze-resistant Dual Station ountain with ottle illing Station with rounded corner design, heavy-duty steel with textured powdercoat finish and E-Coat immersion for year-round beauty with minimum maintenance. The E-Coat immersion process coats the inside and outside for the ultimate in corrosion protection. reeze Resistant Dual Station OTTLE ILLER Provides a quick fill at 1 gallon per minute. Laminar flow provides a clean fill with minimal splash and easy maintenance. ULER Vandal-resistant bubbler is one-piece, heavy-duty construction. Unit has integral hood guard design to prevent contamination from other users, airborne deposits and tampering. LK44201LRK REEZE-RESISTNT VLVE SYSTEM Designed for ground installation 21 minimum below the frost line. 60 of access tubing provided with the freeze-resistant valve system. The length of tubing can be adjusted in the field for lesser frost depths. SIN Contour-formed stainless steel design with rounded edges reduces splatter, ensures proper drainage and prevents standing water. LK44201URK PUSUTTON CTUTION MECNISM Self-closing, vandal-resistant pushbutton does not require grasping or twisting. WTER INLET & DRIN OUTLET Inlet: 1/4 O.D. Tubing Outlet: 1-1/2 tube outlet for 1-1/2 slip joint connection CCESS PNELS eavy-gauge steel with vandal-resistant screws. Provides access for easy hook-up of all plumbing connections. SUESTED SPECIICTIONS Unit shall include powder-coated finish with vandal-resistant pushbutton actuation, vandal-resistant bubbler with integral hood guard, and contour-formed rounded basin to reduce splash and prevent standing water. ottle iller shall include a laminar flow for minimal splash and provide 1 gallon per minute fill rate. ountain shall comply with NSI 117:1 and D for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NS/NSI 61, and the Safe Drinking Water ct. LK44201URK LK44201LRK ottle iller Placement Upper Lower Color Option (Refer to inish Color Options) (Refer to inish Color Options) D Compliant NS/NSI 61 Certified Select color option to complete model number. Example: LK44201URKEV This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producer s offerings, be certain these features are not overlooked. Now vailable in 12 Colors! eige lack lue rown Evergreen ray Orange Purple Red Terracotta White Yellow INIS COLOR OPTIONS Choose color option to complete your model number, add as suffix example: LK44201URKEV Matte finish: Evergreen = EV loss finish: eige = E ray = RY Terracotta = TER lack = LK Orange = ORN White = WT lue = LU Purple = PUR Yellow = YLW rown = RN Red = RED OPTIONS ose ib (Locking) - LK4471L (Choose color option to complete your model number) ose ib (Non-Locking) - LK4470NL (Choose color option to complete your model number) Direct ury Kit - 97890C Each 4420 R consists of 2 cartons of the following: ountain Dual reeze-resistant Valve System - 98837C In keeping with our policy of continuing product improvement, Elkay reserves the right to change specification without notice. Please visit for the most current version. SPEC19-34 (10/15)

MODEL LK44201URK Locate and install plumbing through ground as required. ssemble 1/2" O (6) (13mm) O 12" 305mm.C. OPERTIN PRESSURES: O 29" 737mm O 1 356mm REER TO PE 4 OR REEZE RESISTNT VLVE INSTLLTION 2 7/ 73mm 6 1626mm 34 11/16" 881mm 4 1118mm 33 5/16" 847mm D Requirement = CCESS PNEL (8 x 10 ) = REMOVLE OTTOM COVER Page 2 Printed in the U.S..

MODEL LK44201LRK Locate and install plumbing through ground as required. ssemble O 1/2" 13mm (6 PL) O 12" 305mm.C. OPERTIN PRESSURES: 29" 737mm O 1 356mm REER TO PE 5 OR REEZE RESISTNT VLVE INSTLLTION O 41 11/16" 1059mm ORIICE EIT 57" 1448mm 40 5/16" 1025mm 37" 940mm D Requirement = CCESS PNEL (8 x 10 ) = REMOVLE OTTOM COVER Page 3 Printed in the U.S..

MODEL LK44201URK Locate and install plumbing through ground as required. ssemble 6 - O.500" OLES EQULLY SPCED ON TWO O 12.00".C. PVC COLUMN CENTERED ETWEEN MOUNTIN OLT OLES OPERTIN PRESSURES: 482mm SITE PREPRTION DETIL CONCRETE SL ROST LINE DEPT DEPENDNT ON EORPIC LOCTION ND LOCL REQUIREMENTS 36 Minimum 67 Maximum ILL LINE 12" 305mm CK ILL ( DIRT ) ROST LINE 21" 533mm 4 1118mm 34 7/16" 875mm 33 5/16" 847mm 6 1626mm J WTER INLET LINE ( Y INSTLLER ) 5 CUIC EET POROUS ILL ( LRE ROKEN ILL ) DRIN LINE Y INSTLLER ( S REQUIRED Y LOCL CODES ) C E D LEEND = CCESS PNEL (8 X 10 ) = REMOVLE OTTOM COVER C = 1 PVC DRIN D = PRESSURE ITTIN 1-1/4 x 3/4 E = CONNECTOR 1-1/4 to 1-1/4 = 1-1/4 DRIN TUE = IR CONTROL LINE = 1/4 WTER LINE J = CONNECTOR OR IR CONTROL LINE DRIN LINE WTER INLET D Requirement Page 4 Printed in the U.S..

MODEL LK44201LRK Locate and install plumbing through ground as required. ssemble 6 - O.500" OLES EQULLY SPCED ON TWO O 12.00".C. PVC COLUMN CENTERED ETWEEN MOUNTIN OLT OLES OPERTIN PRESSURES: SITE PREPRTION DETIL CONCRETE SL ROST LINE DEPT DEPENDNT ON EORPIC LOCTION ND LOCL REQUIREMENTS 36 Minimum 67 Maximum ILL LINE 12" 305mm CK ILL ( DIRT ) ROST LINE 21" 533mm 41 11/16" 1059mm 40 5/16" 1025mm J 37" 940mm 57" 1448mm WTER INLET LINE ( Y INSTLLER ) 5 CUIC EET POROUS ILL ( LRE ROKEN ILL ) DRIN LINE Y INSTLLER ( S REQUIRED Y LOCL CODES ) C E D LEEND = CCESS PNEL (8 X 10 ) = REMOVLE OTTOM COVER C = 1 PVC DRIN D = PRESSURE ITTIN 1-1/4 x 3/4 E = CONNECTOR 1-1/4 to 1-1/4 = 1-1/4 DRIN TUE = IR CONTROL LINE = 1/4 WTER LINE J = CONNECTOR OR IR CONTROL LINE DRIN LINE WTER INLET D Requirement Page 5 Printed in the U.S..