Masoneilan* 78 Model Air Filter Regulator

Similar documents
GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

Masoneilan* Model 78-80H & 08-80H Transfer Valves

Masoneilan* Model 78-80S & 08-80S Transfer Valves

Becker* Model FD-1500 Filter/Dryer

Masoneilan* Series Self Operating Pressure Regulators

Mooney* Series 21 Regulator

173 Series Self-Operating Pressure Regulators

Masoneilan * DSH * Series Desuperheater

1805 Series Relief Valves

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

CSA Sample Draw Aspirator Adapter Operator s Manual

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Mooney* Flowgrid* Slam Shut* 1 Valve

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

PRO-50 Instrument Supply Regulator

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

64 Series Pressure Reducing Regulators

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

MEGR-1627 Instruction Manual

Type R622 Pressure Reducing Regulator

Model Series 62 Constant Differential Relay

1305 Series Pressure Reducing Regulators

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Model 40H Nullmatic Pressure Regulators

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

DS06D,G Dial Set Pressure Regulating Valve

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Types S100K and S102K Pressure Regulators

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

1200 Series Pressure Regulators

1805 Series Relief Valves

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Interface Devices, Inc. Hydraulic Mini Mule

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Installation, Operation, and Maintenance Manual

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

D05T Compact Design Pressure Regulating Valves

1200B2 Series Service Regulators. Instruction Manual

Fisher DVI Desuperheater Venturi Inline

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

MEGR-1912 Instruction Manual

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

1800C and 1800C-HC Series Service Regulators

Standard Specifications

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Types 749B and R130 Changeover Manifolds

Precision and Instrument Regulators 1/4" port size

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

Instruction Manual No. 742, 8/98

OPERATING AND MAINTENANCE MANUAL

Operation Manual Air Saver Unit ASV5000 Series

Installation, Operation, and Maintenance Manual

Direct Operated Precision Regulator Modular Style. Standard Specifications

Instruction Manual Updated 7/26/2011 Ver. 2.2

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

1301 Series High-Pressure Regulators

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

Back Pressure Regulator

User Instruction Manual

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

RB Series Regulating System

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

VACUUM REGULATORS CONTENTS

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

BACK PRESSURE VALVE. Instructions Parts List J

Series IRV1000/2000/3000

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

INSTRUCTIONS FOR SINGLE STAGE LECTURE BOTTLE REGULATORS

Regulator from 1800 B series

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

B84G - Excelon Plus Modular System General purpose filter/regulator

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Series MX pressure regulators 3/

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

670 Series Panel-Mounted Loading Regulators

1566 & Models

WW-730. Pressure Sustaining/Relief Control Valve

Transcription:

GE Oil & Gas Masoneilan* 78 Model Air Filter Regulator Instruction Manual [Rev. D] GE Data Classification : Public

THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE INFORMATION IN ADDITION TO THE CUSTOMER/OPERATOR S NORMAL OPERATION AND MAINTENANCE PROCEDURES. SINCE OPERATION AND MAINTENANCE PHILOSOPHIES VARY, GE (GENERAL ELECTRIC COMPANY AND ITS SUBSIDIARIES AND AFFILIATES) DOES NOT ATTEMPT TO DICTATE SPECIFIC PROCEDURES, BUT TO PROVIDE BASIC LIMITATIONS AND REQUIREMENTS CREATED BY THE TYPE OF EQUIPMENT PROVIDED. THESE INSTRUCTIONS ASSUME THAT OPERATORS ALREADY HAVE A GENERAL UNDERSTANDING OF THE REQUIREMENTS FOR SAFE OPERATION OF MECHANICAL AND ELECTRICAL EQUIPMENT IN POTENTIALLY HAZARDOUS ENVIRONMENTS. THEREFORE, THESE INSTRUCTIONS SHOULD BE INTERPRETED AND APPLIED IN CONJUNCTION WITH THE SAFETY RULES AND REGULATIONS APPLICABLE AT THE SITE AND THE PARTICULAR REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE. THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE CUSTOMER/OPERATOR S PURPOSES THE MATTER SHOULD BE REFERRED TO GE. THE RIGHTS, OBLIGATIONS AND LIABILITIES OF GE AND THE CUSTOMER/OPERATOR ARE STRICTLY LIMITED TO THOSE EXPRESSLY PROVIDED IN THE CONTRACT RELATING TO THE SUPPLY OF THE EQUIPMENT. NO ADDITIONAL REPRESENTATIONS OR WARRANTIES BY GE REGARDING THE EQUIPMENT OR ITS USE ARE GIVEN OR IMPLIED BY THE ISSUE OF THESE INSTRUCTIONS. THESE INSTRUCTIONS ARE FURNISHED TO THE CUSTOMER/OPERATOR SOLELY TO ASSIST IN THE INSTALLATION, TESTING, OPERATION, AND/OR MAINTENANCE OF THE EQUIPMENT DESCRIBED. THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN APPROVAL OF GE. 2 GE Oil & Gas 2017 General Electric Company. All rights reserved.

Safety Information Important - Please Read Before Installation The model 78 Series air filter regulator instructions contain DANGER, WARNING, and CAUTION labels where necessary, to alert you to safety related or other important information. Read the instructions carefully before installing and maintaining your control valve. DANGER and WARNING hazards are related to personal injury. CAUTION hazards involve equipment or property damage. Operation of damaged equipment can, under certain operational conditions, result in degraded process system performance that can lead to injury or death. Total compliance with all DANGER, WARNING, and CAUTION notices is required for safe operation. W This is the safety alert symbol. It alerts you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. About this Manual The information in this manual is subject to change without prior notice. The information contained in this manual, in whole or part, shall not be transcribed or copied without GE s written permission. Please report any errors or questions about the information in this manual to your local supplier. These instructions are written specifically for the model 78 air filter regulator, and do not apply for other instrument outside of this product line. Warranty Items sold by General Electric are warranted to be free from defects in materials and workmanship for a period of one year from the date of shipment provided said items are used according to GE recommended usages. GE reserves the right to discontinue manufacture of any product or change product materials, design or specifications without notice. Note: Prior to installation The instrument must be installed, put into service and maintained by qualified and competent professionals who have undergone suitable training. All surrounding pipe lines must be thoroughly flushed to ensure all entrained debris has been removed from the system. Under certain operating conditions, the use of damaged equipment could cause a degradation of the performance of the system which may lead to personal injury or death. Changes to specifications, structure, and components used may not lead to the revision of this manual unless such changes affect the function and performance of the product. CAUTION When used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, could result in property damage. Note: Indicates important facts and conditions. 2017 General Electric Company. All rights reserved. Masoneilan Model 78 Series Air Filter Regulator Instructions Manual 3

Model 78 Air Filter Regulators Product Description The Model 78 Series pressure regulators are compact, lightweight, high-performance pressure reducing instruments. They are used primarily for supplying a stable source of air to process control equipment such as current to pneumatic transducers and control valve positioners. Numbering System 78-4 78-40 Model No. Pressure Range Description Specifications 5-40 psi (35-280 kpa), (0.35-2.8 bar) 5-100 psi (35-700 kpa), (0.35-7 bar) Air Loading with Relief and Filter Air Loading with Relief and Filter Inlet Pressure Rating 210 psi (1.5 MPa, 15 bar) maximum 5-40 psi (35-280 kpa, 0.35-2.8 Pressure Set Range bar)5-100 psi (35-700 kpa, 0.35-7 bar) Connection 1/4 NPT Rated Cv 0.25 Filter Element Sintered Porous Polyethylene (5μ) Ambient Temperature Range -40 to +83 C (-40 to +182 F) Air Consumption 0.004 scfm (100 sccm) Weight 14 oz. (0.4 kg) Materials of Construction See table next page WARNING Do not install this Regulator in air lines which exceed 210 psi (1.5 MPa, 15 bar) pressure. Installation Clean the lines thoroughly to remove all dirt, scale or other foreign matter before installing the regulator. Install with flow in direction of flow arrows on regulator body. The airset should be installed with the drain cock facing down. Regulator should be installed as close as possible to device utilizing the reduced pressure to minimize pressure drop. Do not use piping or tubing smaller than the regulator connections since this will restrict flow and reduce capacity. It is recommended that pressure gauges be installed on the inlet and outlet sides of the regulator as an aid in adjusting the pressure and in monitoring of working pressures. Operation Prior to applying supply pressure, loosen knob lock screw and turn pressure set knob counterclockwise. Turn on supply pressure. Output pressure should be zero. Slowly rotate set knob clockwise until desired pressure is reached. Tighten knob locking screw to ensure that pressure remains set at desired value. When changing output from a higher to lower pres sure, initially go to lower than desired pressure, then increase to desired pressure. Re-tighten knob lock-screw. Maintenance It is recommended that the drain cock be opened at regular intervals to drain any fluid that may have collected in the dripwell. The interval between draining will have to be determined based on the actual rate of accumulation of fluid. It is recommended that pressure gauges be installed on the inlet and outlet sides of the regulator as an aid in adjusting the pressure and in monitoring of working pressures. WARNING The relief valve feature should not be confused with any auxiliary safety valve which might be needed for complete protection of air operated equipment. It is intended only to provide more uniform controlled pressure and to permit adjusting the outlet pressure downward without venting the line. WARNING Prior to performing maintenance on the regulator, shut off the inlet and outlet pressures and remove the spring compression by turning the setting knob fully counterclockwise. Open the drain cock carefully to relieve any retained pressure and drain the dripwell. It is recommended that the regulator be removed from the line for repairs. CAUTION When draining the dripwell, open the drain cock slowly and collect the fluid in a suitable container for safe disposal. Note: Considering the high labor costs involved in replacing internal parts, it may be more economical to stock complete units. Care must be taken to avoid damage to the plug and stem assembly. 4 GE Oil & Gas 2017 General Electric Company. All rights reserved.

Troubleshooting If at any time the regulator fails to function properly it is recommended to replace rather than repair the device. 5 Parts List and Materials of Construction No. Part Standard Material 1 Body Aluminum Die Casting 2 Spring Casing Aluminum Die Casting 3 Bottom Cap Aluminum Die Casting 4 Knob VALOX 420 5 Lock Screw Stainless Steel 6 Adjusting Screw Stainless Steel 7 Spacer VALOX 420 8 Spring Button Zn-Cr Plated Carbon Steel 9 Spring Coated Spring Steel 10 1 Diaphragm NBR 15 Plug Guide VALOX 420 16 1 Plug Neoprene/416 Stainless Steel 17 1 Filter Sintered Polyethylene 18 1 Port Spring Stainless Steel 19 1 O -Ring NBR - 21 Drain Cock Stainless Steel 22 Screw Stainless Steel 23 Pipe Plug Zinc Plated Carbon Steel 24 Aspirator VALOX 420 25 Nameplate Aluminum 1 Recommended Spare Parts 25 2 10 7 6 8 9 3 21 4 22 23 22 15 16 18 17 19 1 24 23 2017 General Electric Company. All rights reserved. Masoneilan Model 78 Series Air Filter Regulator Instructions Manual 5

Dimensions Threaded Holes for Mounting Bracket (M5) Top View 81 mm (3.19 in.) 52 mm (2.05 in.) 141 mm (5.55 in.) 60 mm (2.36 in.) 55 mm (2.17 in.) Cut-Away View of 78 Series Pressure Regulator Lock Screw Spring Button Setting Knob Adjust Screw Spring Case Spring Relief Valve Diaphragm Diaphragm Plate Body INLET Plug Filter Port Spring Aspirator OUTLET Supply Valve Bottom Cap Drain Cock 6 GE Oil & Gas 2017 General Electric Company. All rights reserved.

2017 General Electric Company. All rights reserved. Masoneilan Model 78 Series Air Filter Regulator Instructions Manual 7

DIRECT SALES OFFICE LOCATIONS AUSTRALIA Brisbane: Phone: +61-7-3001-4319 Fax: +61-7-3001-4399 Perth: Phone: +61-8-6595-7018 Fax: +61 8 6595-7299 Melbourne: Phone: +61-3-8807-6002 Fax : +61-3-8807-6577 BELGIUM Phone: +32-2-344-0970 Fax: +32-2-344-1123 BRAZIL Phone: +55-19-2104-6900 CHINA Phone: +86-10-5689-3600 Fax: +86-10-5689-3800 FRANCE Courbevoie Phone: +33-1-4904-9000 Fax: +33-1-4904-9010 GERMANY Ratingen Phone: +49-2102-108-0 Fax: +49-2102-108-111 INDIA Mumbai Phone: +91-22-8354790 Fax: +91-22-8354791 New Delhi Phone: +91-11-2-6164175 Fax: +91-11-5-1659635 ITALY Phone: +39-081-7892-111 Fax: +39-081-7892-208 JAPAN Tokyo Phone: +81-03-6871-9008 Fax: +81-03-6890-4620 KOREA Phone: +82-2-2274-0748 Fax: +82-2-2274-0794 MALAYSIA Phone: +60-3-2161-0322 Fax: +60-3-2163-6312 MEXICO Phone: +52-55-3640-5060 THE NETHERLANDS Phone: +31-15-3808666 Fax: +31-18-1641438 RUSSIA Veliky Novgorod Phone: +7-8162-55-7898 Fax: +7-8162-55-7921 Moscow Phone: +7 495-585-1276 Fax: +7 495-585-1279 SAUDI ARABIA Phone: +966-3-341-0278 Fax: +966-3-341-7624 SINGAPORE Phone: +65-6861-6100 Fax: +65-6861-7172 SOUTH AFRICA Phone: +27-11-452-1550 Fax: +27-11-452-6542 SOUTH & CENTRAL AMERICA AND THE CARIBBEAN Phone: +55-12-2134-1201 Fax: +55-12-2134-1238 SPAIN Phone: +34-93-652-6430 Fax: +34-93-652-6444 UNITED ARAB EMIRATES Phone: +971-4-8991-777 Fax: +971-4-8991-778 UNITED KINGDOM Bracknell Phone: +44-1344-460-500 Fax: +44-1344-460-537 Skelmersdale Phone: +44-1695-526-00 Fax: +44-1695-526-01 UNITED STATES Jacksonville, Florida Phone: +1-904-570-3409 Corpus Christi, Texas Phone: +1-361-881-8182 Fax: +1-361-881-8246 Deer Park, Texas Phone: +1-281-884-1000 Fax: +1-281-884-1010 Houston, Texas Phone: +1-281-671-1640 Fax: +1-281-671-1735 *Denotes a trademark of General Electric Company. Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. 2017 General Electric Company. All rights reserved. GEA31190D 03/2017