GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

Similar documents
Masoneilan* 78 Model Air Filter Regulator

Masoneilan* Model 78-80H & 08-80H Transfer Valves

Masoneilan* Model 78-80S & 08-80S Transfer Valves

Becker* Model FD-1500 Filter/Dryer

Masoneilan* Series Self Operating Pressure Regulators

Mooney* Series 21 Regulator

173 Series Self-Operating Pressure Regulators

Masoneilan * DSH * Series Desuperheater

Mooney* Flowgrid* Slam Shut* 1 Valve

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

1805 Series Relief Valves

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

64 Series Pressure Reducing Regulators

Pressure Regulators. Operating Instructions. Instrumentation

BACK PRESSURE VALVE. Instructions Parts List J

Back Pressure Regulator

Installation, Operation, and Maintenance Manual

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Model Series 62 Constant Differential Relay

Model 9201E Tempered Water Blending System

Installation, Operation, and Maintenance Manual

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Types S100K and S102K Pressure Regulators

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

1566 & Models

MEGR-1627 Instruction Manual

1305 Series Pressure Reducing Regulators

CSA Sample Draw Aspirator Adapter Operator s Manual

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

WHEATLEY Series 500 Swing Check Valve

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

1200B2 Series Service Regulators. Instruction Manual

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

INSTRUCTIONS PARTS LIST

Putting You In Control. Model 4411 Electropneumatic Transducer. Instruction Manual ES /10

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

COSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

92831 TEL: (714) FAX:

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Model Series 63DL Differential Type Flow Controller

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Pressure Relief Valve Instruction Manual

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Installation Instructions JATCO Environmental Protection Tank Model J-7000

RB Series Regulating System

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

CF-SERIES HIGH FLOW REGULATORS

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

1805 Series Relief Valves

Color/Catalyst Dispense Valves

453 Series Steam Heated Vaporizing Regulator

Type R622 Pressure Reducing Regulator

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Model Visit our website at:

Installation, Operation and Maintenance Manual

A-DR20-2/A-DR20-6/A-DR20-10

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Fisher DVI Desuperheater Venturi Inline

FLANGED TWO-PIECE BALL VALVES

Instructions Parts List

Types 749B and R130 Changeover Manifolds

Type CT88 Backpressure Regulator

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Installation, Operation, and Maintenance Manual

D05T Compact Design Pressure Regulating Valves

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

MODELS & (OBS) REMOTE FLUID PRESSURE REGULATORS (30 OZ./MIN. & 100 OZ./MIN.)

1800C and 1800C-HC Series Service Regulators

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

ACCESSORY KIT INSTALLATION INSTRUCTIONS

DS05C,D,G Dial Set Pressure Regulating Valves

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

PDY TON HYDRAULIC CRIMPING TOOL WARNING

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

HYDRAULIC WINCH FOR AUGERS UP TO WR10 X 71 / W130 X 41 ASSEMBLY & OPERATION MANUAL

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

User Instruction Manual

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

Model No Product Name Handpiece Only Complete System

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

1301 Series High-Pressure Regulators

Transcription:

GE Oil & Gas 77-6 Model Masoneilan* Air Lock-up Valve Instruction Manual GE Data Classification : Public

THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE INFORMATION IN ADDITION TO THE CUSTOMER/OPERATOR S NORMAL OPERATION AND MAINTENANCE PROCEDURES. SINCE OPERATION AND MAINTENANCE PHILOSOPHIES VARY, GE (GENERAL ELECTRIC COMPANY AND ITS SUBSIDIARIES AND AFFILIATES) DOES NOT ATTEMPT TO DICTATE SPECIFIC PROCEDURES, BUT TO PROVIDE BASIC LIMITATIONS AND REQUIREMENTS CREATED BY THE TYPE OF EQUIPMENT PROVIDED. THESE INSTRUCTIONS ASSUME THAT OPERATORS ALREADY HAVE A GENERAL UNDERSTANDING OF THE REQUIREMENTS FOR SAFE OPERATION OF MECHANICAL AND ELECTRICAL EQUIPMENT IN POTENTIALLY HAZARDOUS ENVIRONMENTS. THEREFORE, THESE INSTRUCTIONS SHOULD BE INTERPRETED AND APPLIED IN CONJUNCTION WITH THE SAFETY RULES AND REGULATIONS APPLICABLE AT THE SITE AND THE PARTICULAR REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE. THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE CUSTOMER/OPERATOR'S PURPOSES THE MATTER SHOULD BE REFERRED TO GE. THE RIGHTS, OBLIGATIONS AND LIABILITIES OF GE AND THE CUSTOMER/OPERATOR ARE STRICTLY LIMITED TO THOSE EXPRESSLY PROVIDED IN THE CONTRACT RELATING TO THE SUPPLY OF THE EQUIPMENT. NO ADDITIONAL REPRESENTATIONS OR WARRANTIES BY GE REGARDING THE EQUIPMENT OR ITS USE ARE GIVEN OR IMPLIED BY THE ISSUE OF THESE INSTRUCTIONS. THESE INSTRUCTIONS ARE FURNISHED TO THE CUSTOMER/OPERATOR SOLELY TO ASSIST IN THE INSTALLATION, TESTING, OPERATION, AND/OR MAINTENANCE OF THE EQUIPMENT DESCRIBED. THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART TO ANY THIRD PARTY WITHOUT THE WRITTEN APPROVAL OF GE. 2 GE Oil & Gas

Safety Information Important - Please Read Before Installation These instructions contain DANGER, WARNING, and CAUTION labels, where necessary, to alert you to safety related or other important information. Read the instructions carefully before installing and maintaining your control valve. DANGER and WARNING hazards are related to personal injury. CAUTION hazards involve equipment or property damage. Operation of damaged equipment can, under certain operational conditions, result in degraded process system performance that can lead to injury or death. Total compliance with all DANGER, WARNING, and CAUTION notices is required for safe operation. W This is the safety alert symbol. It alerts you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in serious injury. Warranty Items sold by General Electric are warranted to be free from defects in materials and workmanship for a period of one year from the date of shipment provided said items are used according to GE recommended usages. GE reserves the right to discontinue manufacture of any product or change product materials, design or specifications without notice. This instruction manual applies to the 77-6 Model Air Lockup valve control valves. Note: The 77-6 air lock-up valve MUST BE installed, put into service and maintained by qualified and competent professionals who have undergone suitable training. Changes to specifications, structure, and components used may not lead to the revision of this manual unless such changes affect the function and performance of the product. All surrounding pipe lines must be thoroughly flushed to ensure all entrained debris has been removed from the system. DANGER Under certain operating conditions, the use of damaged equipment could cause a degradation of the performance of the system which may lead to personal injury or death. CAUTION Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. CAUTION When used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, could result in property damage. Note: Indicates important facts and conditions. About this Manual The information in this manual is subject to change without prior notice. The information contained in this manual, in whole or part, shall not be transcribed or copied without GE s written permission. Please report any errors or questions about the information in this manual to your local supplier. These instructions are written specifically for the 77-6 Model Air Lock-up valve control valves, and do not apply for other valves outside of this product line. Masoneilan 77-6 Model Air Lock-up Valve Instruction Manual 3

WARNING Please read these instructions carefully BEFORE this instrument is installed or maintained. These converters are intended for use in industrial compressed air systems only. Ensure that adequate pressure relief provision is installed if application of system supply pressure could cause downstream equipment to malfunction. Installation should be in accordance with local and national compressed air and instrumentation codes. Products certified for use in explosion-proof or intrinsically safe installations MUST: a) Be installed in accordance with local and national codes for hazardous area installations, and in accordance with this manual. b) Only be used in situations which comply with the certification conditions stated in this handbook. c) Only be maintained by qualified personnel with adequate training on hazardous area implementation. Before using these products with fluids other than air or for non- industrial applications consult GE. Installation CAUTION Adjustment The lock-up valve is normally factory set (i.e., 20 psi for 3-15 psi operation or 35 psi for 6-30 psi operation) and should not require adjustment. If, however, it becomes necessary to adjust the setting an air supply, with a gauge and regulator, should be piped to the signal pressure connection after: (1) relieving compression on the range spring of the lock-up valve; and (2) connecting the instrument output line to the inlet connection of the lock-up valve. Instrument output pressure need be sufficient only to determine the open and closed position of the lock-up valve. Turn the air supply pressure on until the pressure gauge indicates the desired set pressure, then turn the adjusting screw down until no air pressure may be felt coming from the outlet of the lock-up valve. The valve will be fully closed at this point. Finally, tighten the adjusting screw locknut and connect: (1) the lock-up valve outlet connection to the control valve diaphragm chamber; and (2) the signal pressure line to the signal pressure connection of the lock-up valve. Turn on and set the air supply to operating pressure. Be sure that all pipe connections are tight. Do not use for air pressures exceeding 250 psi. Prior to installing, clean all lines thoroughly to remove all dirt, scale or other foreign matter. Install the lock-up valve in the controller output line as near to the control valve diaphragm chamber as possible, holding the number of connections to a minimum so that the air flows through the body in the direction indicated by the words INLET and OUTLET marked on the underside of valve body. The signal pressure line should be connected upstream of the air supply regulator to provide effective response of the lock-up valve in the event of air failure. Be sure all pipe connections are tight. Do not install this Air Lock-up Valve in air lines which exceed 250 psi (1.72 MPa, 17.2 bar) pressure. 4 GE Oil & Gas

Maintenance Due to their design and intended application, maintenance difficulties are not expected to be encountered with these valves. If they fail to perform in a satisfactory manner, it may be due to accumulation of dirt in one or more of the parts. If necessary to disassemble, proceed as follows, after: (1) shutting off supply pressure; and (2) relieving spring compression by backing off the adjustment screw. Remove the four body cap screws (16); body cap (15), body cap O-ring (14), range spring (3), upper spring button (2) and spring case (9) will come free from body (7). To free diaphragm S/A (10) and inlet valve S/A (12) from the body, place the wrench on the insert retainer (13) and unscrew from the body insert (5). Remove the body insert O-ring (6) and slide the diaphragm S/A, the body insert and the inlet valve S/A from the body. Holding the inlet valve from turning, unscrew inlet valve locknut (4) and remove diaphragm S/A from the inlet valve. Turn the inlet valve out of body insert. the diaphragm S/A for rupture or for damage around the edge. If necessary, install a new diaphragm S/A. Check the inlet valve for wear. If the inlet valve is roughed-up or pitted, replace with new one. To reassemble the lock-up valve, perform all operations in reverse order to that used in disassembly. Note: The O-ring on the inlet valve stem should be lubricated before the inlet valve is reassembled in the body insert. Note: Considering the high labor costs involved in replacing internal parts, it may be more economical to stock complete units. Check all ports to be sure they are clear of dirt. Inspect Prior to performing maintenance on the Air Lock-up Valve, shut off the supply pressure and remove the spring compression by backing off the adjustment screw. It is recommended that the Air Lock-up Valve be removed from the line for repairs. 16 Signal Pressure Ref. Qty Part Name Ref. Qty Part Name 1 1 Adjusting Screw 9 1 Spring Case 2 1 Upper Spring Button 10 1 Diaphragm S/A 3 1 Range Spring 11 1 Inlet Valve O-Ring 4 1 Inlet Valve Locknut 12 1 Inlet Valve S/A 5 1 Body Insert 13 1 Insert Retainer 6 2 O-Rings 14 1 Body Cap O-Ring 7 1 Body 15 1 Body Cap 8 1 Locknut 16 4 Body Cap Screws Not visible in cutaway view. Masoneilan 77-6 Model Air Lock-up Valve Instruction Manual 5

Notes 6 GE Oil & Gas

Notes Masoneilan 77-6 Model Air Lock-up Valve Instruction Manual 7

DIRECT SALES OFFICE LOCATIONS AUSTRALIA Brisbane: Phone: +61-7-3001-4319 Fax: +61-7-3001-4399 Perth: Phone: +61-8-6595-7018 Fax: +61 8 6595-7299 Melbourne: Phone: +61-3-8807-6002 Fax : +61-3-8807-6577 BELGIUM Phone: +32-2-344-0970 Fax: +32-2-344-1123 BRAZIL Phone: +55-11-2146-3600 Fax: +55-11-2146-3610 CHINA Phone: +86-10-5689-3600 Fax: +86-10-5689-3800 FRANCE Courbevoie Phone: +33-1-4904-9000 Fax: +33-1-4904-9010 GERMANY Ratingen Phone: +49-2102-108-0 Fax: +49-2102-108-111 INDIA Mumbai Phone: +91-22-8354790 Fax: +91-22-8354791 New Delhi Phone: +91-11-2-6164175 Fax: +91-11-5-1659635 ITALY Phone: +39-081-7892-111 Fax: +39-081-7892-208 JAPAN Chiba Phone: +81-43-297-9222 Fax: +81-43-299-1115 KOREA Phone: +82-2-2274-0748 Fax: +82-2-2274-0794 MALAYSIA Phone: +60-3-2161-0322 Fax: +60-3-2163-6312 MEXICO Phone: +52-55-3640-5060 THE NETHERLANDS Phone: +31-15-3808666 Fax: +31-18-1641438 RUSSIA Veliky Novgorod Phone: +7-8162-55-7898 Fax: +7-8162-55-7921 Moscow Phone: +7 495-585-1276 Fax: +7 495-585-1279 SAUDI ARABIA Phone: +966-3-341-0278 Fax: +966-3-341-7624 SINGAPORE Phone: +65-6861-6100 Fax: +65-6861-7172 SOUTH AFRICA Phone: +27-11-452-1550 Fax: +27-11-452-6542 SOUTH & CENTRAL AMERICA AND THE CARIBBEAN Phone: +55-12-2134-1201 Fax: +55-12-2134-1238 SPAIN Phone: +34-93-652-6430 Fax: +34-93-652-6444 UNITED ARAB EMIRATES Phone: +971-4-8991-777 Fax: +971-4-8991-778 UNITED KINGDOM Bracknell Phone: +44-1344-460-500 Fax: +44-1344-460-537 Skelmersdale Phone: +44-1695-526-00 Fax: +44-1695-526-01 UNITED STATES Massachusetts Phone: +1-508-586-4600 Fax: +1-508-427-8971 Corpus Christi, Texas Phone: +1-361-881-8182 Fax: +1-361-881-8246 Deer Park, Texas Phone: +1-281-884-1000 Fax: +1-281-884-1010 Houston, Texas Phone: +1-281-671-1640 Fax: +1-281-671-1735 *Denotes a trademark of the General Electric Company. Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. GEA31168A 07/2015