Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens.

Similar documents
EasyLine Continuous Gas Analyzers. So smart, they re simple

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

LT GasAnalyzer beyond standards

LFE OEM TCD - Thermal Conductivity Detector

Continuous Gas Analyzers, extractive

Pressure measurement is a family affair

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders.

Continuous Gas Analyzers, extractive

MATRIX-MG Series. Innovation with Integrity. Automated High-Performance Gas Analyzers FT-IR

1 Overview. Continuous Gas Analyzers, extractive ULTRAMAT 6. General information

1 Overview. Extractive continuous process gas analysis Series 6 ULTRAMAT 6. General information

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Continuous gas analysis. SIPROCESS GA700 Rack-mounted device. Introduction 1. General safety instructions 2. Description 3. Application planning 4

ULTRAMAT 6. General information 2/29

Vortex Meters for Liquids, Gas, and Steam

Oxygen & Binary Gas Measurement and Analysis

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

HydroCOM: High energy savings and excellent controllability

Supplementary Operator s Manual 42/24-14 EN Rev. 3

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

Continuous Gas Analyzers, extractive

Flow metering in gases Introduction to COMBIMASS family

Continuous Gas Analyzers, extractive

Process Analytical Instruments

Low gas volume & flow measurements made easier Gas Endeavour

Pneumatic high-pressure controller Model CPC7000

deltaflowc deltaflowc Venturi or Probe

FTC130 Transmitter. Operating Manual

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Reliable, low-maintenance pressure measurement with SITRANS P

Model EXAxt AV550G. Averaging Oxygen Analyzer

GasSense NDIR User Manual

The original. 6-way zone valve from Belimo.

1 Overview ULTRAMAT/OXYMAT 6. General information

THE WATER-COOLED INDUSTRIAL RANGE

Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17

For the highest operational safety around the clock

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Level, Pressure, and Density Instrumentation for the Petrochemical Industry

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

ULTRAMAT/OXYMAT 6. General information 2/71

Pressure measurement is a family affair

Traysealer T 100. Tray packaging in the smallest space

Micro Motion 3098 Gas Specific Gravity Meter

Extractive continuous process gas analysis Series 6 ULTRAMAT/OXYMAT 6

Press Release. Friction Stir Welding: Grenzebach extends its portfolio

Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS

Continuous Gas Analyzers, extractive SIPROCESS GA700

Analyze IT EL6010 Gas Analyzers in Category 2G

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

Transmitter CS 21 Operation Manual

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Precision matters. HiQ equipment for specialty gases.

PositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Continuous Gas Analyzers, extractive

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

Continuous Gas Analyzers, extractive

Doppelmayr Connect: Welcome to the future

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03

PHOENIX L300i Best-in-class Helium Leak Detectors

Your local gas generation partner. Precision series Modular gas generation solution for GC.

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

ULTRAMAT 6 NDIR Gas Analyzers, Singlechannel or Dual-channel Versions

Advance Optima AO2000 Series Continuous gas analyzers Models AO2020, AO2040. Measurement made easy. Modular continuous gas analyzers

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Exceptional Experience

Cleaning robots for swimming pools - fully automatic, persistent and powerful YOUR PARTNER FOR SWIMMING POOL HYGIENE

Diagnostics in the instrumentation More than just equipment monitoring

SAFE AND ENVIRONMENTALLY FRIENDLY

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

1 Overview. Continuous Gas Analyzers, extractive CALOMAT 6. 1/148 Siemens AP US Edition. General information

This test shall be carried out on all vehicles equipped with open type traction batteries.

Application Note AN-107

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

For the cleanest tablets and capsules

Online data sheet FLOWSIC30 GAS FLOW METERS

Fuel Gas Pressure Control Solutions for Fired Heaters and Boilers

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

KOMPRESSOREN COMPRESSORS KAESER AIR SERVICE Our Services An Overview

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

Transmitter CS 21 Operation Manual

SAFE/REYCO. More than 35,000 variations in DIN EN and ASME. NEW! Now with zero leakage in combination with SHR premium soft seal* (now up to +220 C)

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Continuous Gas Analyzer Transmitter

deltaflowc deltaflowc Venturi or Probe

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Transcription:

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens.

Easier Than Ever SIPROCESS GA700 The New Generation of Continuous Gas Analytics.

Your competent partner for innovative complete solutions in modern process gas analytics. Precise, long-lasting, reliable: in modern process gas analytics, Siemens has been known worldwide for many years for its outstanding quality and technology as well as its comprehensive range of products. With our engineering expertise developed over years, we have taken up the challenge to successfully combine proven techniques with innovative solutions that satisfy the demands of our customers. Now, with SIPROCESS GA700, Siemens has not only developed a new production series, but also a new concept for process gas analytics: the system of modularity. This unique modular concept offers our customers indispensable advantages in the field of continuous gas analytics. Areas of Application for the SIPROCESS GA700: Process control and optimization in incineration plants Process monitoring in chemical and petrochemical plants Quality control of high purity gases

Simply More Options. SIPROCESS GA700 A New Level of Flexibility in Precision Measurement. For those who need flexible solutions to respond quickly to changing requirements. Three analysis modules, two housing types, one operational display unit: there s a system behind the new Siemens production series a unique, modular concept that provides you with more flexibility for the diverse range of market requirements, thus making process analytics easier than ever. Now for the first time, two analysis modules fit into each of the two housing types. The combination 1 of the modules OXYMAT 7, CALOMAT 7, and ULTRAMAT 7 offers many advantages for continuous gas analytics: combined measurements and interfering gas corrections in one device, fast and easy replacing of modules, and thus particularly economic retrofitting or conversion, and operating of all modules effortlessly by just one display unit. The Rack and Wall-Mounted Housing. For the new SIPROCESS GA700, the platform is available in two housing types: the new 19" rack housing in three height units and the wall-mounted housing. Both units can now house two analyzer modules, saving space at the place of operation. From the local user interface, the communication interfaces, the remote user interface to the basic electronics and software, both housings are uniform in terms of their equipment and setup. This simplifies the system integration of the various analyzers. The Plug & Measure Principle. Insert the module, plug in, turn on, and begin measuring after setup, module configuration takes place fully automatically. It s easier than ever. 1 Currently, there are still limitations on certain combinations.

Simply Easier to Operate. It Speaks for Itself The Menu Navigation of the SIPROCESS GA700. For those who want a device with intuitive operation. Uniform, straightforward, multilingual: all SIPROCESS GA700 modules are controlled by an identical operating concept. The uniform construction of the housing and the newly developed universal operating concept combine the proven characteristics of the well-established Series 6. The operating guide is very user-friendly, easy to understand, and now available in ten languages including Chinese, Japanese, and Korean. In addition, the customer-specific settings can be saved and transferred quickly when replacing a module. This minimizes error sources and downtime. Moreover, the quick-start guide helps you get started using the device smoothly. Adjustable view of the measured values Clearly structured software menus Same structure for all analysis modules

Simply More Service Expertise. Always There for You: The Siemens Quality Service. Targeted consulting, safe installation, reliable maintenance: You can take advantage of our global quality service at any time. Now you have the option of performing a complete module replacement on-site. Alternatively, individual components can of course also still be replaced. And thanks to the Plug & Measure principle, you won t have to re-enter param eter settings in an identical module. For the first time, the ULTRAMAT 7 is equipped with a preventive maintenance feature. This feature informs you when the next maintenance is required ahead of time.

The New Siemens Appliance Generation for Gas Analytics with Heat Conductivity Detector SIPROCESS GA700 CALOMAT 7 The CALOMAT 7 analysis module is primarily used for determining the amount of H 2 or He in binary or quasi-binary gas mixtures. Other gases can also be measured, such as Ar, CO 2, CH 4. Your benefits Ideal for binary gases Integrated cross-correction, no external calculation necessary Application switch High measuring range dynamics Wide range of possible uses with up to three applications per module Low detection limits in the measuring range 0 to 0.5 % with hydrogen T 90 time < 2.5 seconds Maximum ambient temperature 50 C Typical application areas Pure gas monitoring Protective gas monitoring Hydrogen measurement in argon Forming gas monitoring Gas production Chemical applications Wood gasification Furnace gas measurement Converter gas Turbo generators 1 1 Planned for future product versions.

Technical Data Features CALOMAT 7 Fitted in housing 19" rack housing IP20 (three height units; Ex na); wall housing IP65 Modularity Up to two modules (C7, U7, O7) 1 Measuring principle Heat conductivity measurement Largest measuring range 0 100 % Smallest measuring range 0 0.5 % Measuring range with physical zero point suppression Ambient pressure compensation Delayed display (T 90 time) 95 100 % Standard < 2.5 s Ambient temperature 0 + 50 C Sample gas pressure / correction range Module exchange on site Repeatability Measured value drift 700 1200 hpa (abs.) Possible ± 1 % of the current measuring range ± 1 %/week from the smallest measuring range according to type label 1 Currently there are still limitations on certain combinations. Siemens AG Process Industries and Drives Östliche Rheinbrückenstr. 50 76187 Karlsruhe Germany

The New Siemens Appliance Generation for Measuring Oxygen SIPROCESS GA700 OXYMAT 7 The function of the OXYMAT 7 analysis module is based on the paramagnetic alternating pressure method and is used to measure oxygen in gases. Your benefits Resistant to corrosion thanks to an external microflow sensor Long service life Low susceptibility to failure Vibration compensation T 90 time 1.9 seconds Maximum ambient temperature 50 C Small measuring ranges (0 to 0.5 % or 99.5 to 100 % O 2 ) Physically suppressed zero point, e. g. 98 or 99.5 to 100 % O 2 Typical application areas Boiler control in incineration plants Quality and process control in chemical plants Quality control in high-purity gases Environmental protection Purity monitoring Quality control in air separation plants

Technical Data Features OXYMAT 7 Fitted in housing 19" rack housing IP20 (three height units; Ex na); wall housing IP65 (Ex p, Ex nr) Modularity Up to two modules (O7, U7, C7) 1 Measuring principle Paramagnetic alternating pressure principle Largest measuring range 0 100 % Smallest measuring range 0 0.5 % Measuring range with physical zero point suppression Ambient pressure compensation Delayed display (T 90 time) 99.5 100 % Standard 1.9 2.4 s depending on version Ambient temperature 0 + 50 C Sample gas pressure / correction range Vibration compensation Module exchange on site Repeatability Measured value drift 500 3000 hpa absolute (piped) Optional Possible ± 0.5 % from the smallest measuring range or ± 50 vpm O 2 ; the higher value signifies validity ± 0.5 %/month from the smallest measuring range or ± 50 vpm O 2 /month; the higher value signifies validity 1 Currently there are still limitations on certain combinations. Siemens AG Process Industries and Drives Östliche Rheinbrückenstr. 50 76187 Karlsruhe Germany

The New Siemens Appliance Generation for Gas Analytics with NDIR Measurement SIPROCESS GA700 ULTRAMAT 7 The ULTRAMAT 7 analysis module uses the NDIR dual-beam method. It selectively measures gases with an absorption band in the infrared wavelength range, such as CO and CO 2. Your benefits High measuring precision in complex gas mixtures Low detection limits Low maintenance costs due to on-site cleaning of the analysis chambers Simplified cross-gas measurement Preventive maintenance function High selectivity due to two-layer detector Typical application areas Boiler control in incineration plants Emission monitoring in incineration plants 1 Process control in chemical plants Trace measurements in high-purity gas processes MAK value monitoring at workplaces Quality control 1 Planned for future product versions.

Technical Data Features ULTRAMAT 7 Fitted in housing 19" rack housing IP20 (three height units; Ex na); wall housing IP65 Modularity Up to two modules (O7, U7, C7) 1 Measuring principle Largest measuring range 0 100 % NDIR dual-beam alternating light principle with optical decoupler Smallest measuring range, e.g. CO 2 Measuring range with physical zero point suppression Ambient pressure compensation Predictive maintenance (emitter service life) 0 5 vpm 99.5 100 % Standard Yes Ambient temperature + 5 + 45 C Sample gas pressure / correction range Module exchange on site Repeatability Measured value drift 500 1500 hpa (abs.) Possible (inside rack/wall housing) 1 %/week of the current measuring range 2 %/week of the smallest measuring range according to the type label 1 Currently there are still limitations on certain combinations. Siemens AG Process Industries and Drives Östliche Rheinbrückenstr. 50 76187 Karlsruhe Germany

With your investment in continuous gas analyzers, you will benefit from our experience of more than 40 years: An ideal combination of innovative products and proven technology Highest quality and reliability Optimum solutions for your measurement tasks Subject to change without prior notice 05/15 Article No. PDPA-B10017-00-7600 Dispo 27902 WS 05153.0 Printed in Germany Siemens AG 2015 The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. Follow us on: www.twitter.com/siemensindustry www.youtube.com/siemens Siemens AG Process Industries and Drives Östliche Rheinbrückenstr. 50 76187 Karlsruhe Germany