KERN EG/EW Version /02

Similar documents
Operating Instructions Electronic Precision Balances 1 TECHNICAL DATA UNPACKING AND STANDARD EQUIPMENT INSTALLATION...

KERN CM Version /2004

SAUTER FK Version /2016 GB

Operating Manual Body fat balance

User Manual. Precision and Analytical Balances ME-T

All Purpose AP-Series Operation Manual

SonoMeter 30 Energy Meters

Operating instructions Installation instructions To be kept in the vehicle!

EC214 EC215 - EC215R Bench Conductivity Meters

Precision pressure sensor Basic version Model CPT6020

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

English. Quick Guide MS-TS Precision and Analytical Balances

Technical Data Sheet MF010-O-LC

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Precision digital pressure gauge Model CPG1000

Gas density monitor With integrated transmitter Model GDM-100-TI

Manual Weighingblock VB2 series and Uniscale

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

Hand-held pressure calibrator with integrated pump Model CPH6600

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Operating Instructions Temperature Measuring System MF420-5T-100

Digital Melting Point Apparatus

User Manual. Portable Balances PL-E

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20

HI 2314 HI 2315 HI 23151

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Pressure transmitter PASCAL Ci4

Instruction Manual Contact Pressure Vacuum Gauge

METROTEC GSM. Type GSM. Oxygen measurement and control unit. *** Version 1.6 ***

Climatic Independent Level Sensor LAR

Safety Manual VEGAVIB series 60

User Manual. Quantos Automated Dosing Liquid Module

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

High-performance submersible pressure transmitter For level measurement Model LH-10

Pneumatic high-pressure controller Model CPC7000

ANALYTICAL BALANCE OPERATING MANUAL. U.S. Solid USS-DBS Models All Rights Reserved Page 1 USS-DBS MODELS

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

User Manual. GPL 3000 e. gas detector

Digital pressure gauge Model CPG500

High-performance submersible pressure transmitter For level measurement Model LH-10

STANDARD OPERATING PROCEDURE

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

STAGE, STADIUM & X-TREME SHOT.

Digital deadweight tester Model CPD8500

4 - LOAD CELL SCALES - EX VERSION

Digital pressure gauge Model CPG500

Instruction Manual BA90 Precision Barometer

Electronic gas volume corrector model DGVC-04

The Univentor 1250 Anaesthesia Unit

Operating Manual VSA100A. tina29e1 ( )

AMB MOISTURE BALANCE AMB 50, AMB 110 and AMB 310. Operating Manual

Pneumatic high-pressure controller Model CPC7000

Operation Instruction. BSM Series Electronic Precision Balances

KERN YDB-03 Version /2015 GB

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

DK46 - DK800 Supplementary instructions

Digital dead-weight tester Model CPD8500

CO2 incubator with additional process controls

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Instruction Manual Differential Pressure Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-20

A17W49_MASEM_F_EN MANUAL

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

JUMO dtrans p30 Pressure Transmitter

Pressure Switches Application Guideline

Industrial pressure controller Model CPC4000

DTG - LCD Digital Temperature Gauge USER MANUAL

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

! Warning, refer to accompanying documents.

OPTIBAR P 1010 C Technical Datasheet

Mass Flow Controller (MFC) for Gases

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

GasSense NDIR User Manual

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Safety Manual VEGAVIB series 60

High-speed pressure sensor Model CPT6140

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

OXY 3690 MP. Measuring transducer for air oxygen

FLAMMABLE GAS SENSOR/TRANSMITTER

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

NEW: CO2 incubator with sterilizable sensor

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung:

BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

ATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502

Service Test Unit for ROSS Proportional Valves RESK

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

NEW: CO2 incubator with sterilizable sensor

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

Transcription:

E KERN EG/EW Version 1.5 07/02 Operating Instructions Electronic Precision Balances Contents 1 TECHNICAL DATA... 20 2 UNPACKING AND STANDARD ACCESSORIES... 23 3 SETTING UP THE BALANCE... 23 4 EXTERNAL VIEW... 24 5 INSTALLATION... 25 6 POWER SUPPLY... 25 7 DECLARATION OF CONFORMITY... 26 8 ADJUSTING (CAL)... 27 8.1 ADJUSTING FOR VERIFICATION...27 8.2 ADJUSTING (CAL)...28 8.2.1 Balance without internal adjusting weight (models KERN EW)...28 8.3 BALANCE WITH INTERNAL ADJUSTING WEIGHT (MODEL KERN EG)...29 9 OPERATING THE BALANCE... 30 9.1 WARM-UP TIME...30 9.2 POWER DISPLAY...30 9.3 BALANCE ZERO DISPLAY...31 9.4 TARE WEIGHING (TARING)...31 10 GENERAL PROGRAM SETTINGS... 32 11 IMPORTANT INFORMATION... 34 12 TROUBLE SHOOTING... 35 EG-EW-BA-defsinl-0215 19

1 Technical data KERN EW 150-3M EW 300-2M EW 300-2 EW 600-2M Readout (d) 0,001 g 0,01 g 0,01 g 0,01 g Verification value (e) 0,01 g 0,01 g - 0,1 g Weighing range (Max) 150 g 300 g 300 g 600 g Min. load (Min) 0,02 g 0,2 g - 0,5 g Taring range 150 g 300 g 300 g 600 g Reproducibility 0,002 g 0,01 g 0,01 g 0,01 g Linearity ± 0,003 g ± 0,01 g ± 0,01 g ± 0,02 g Adjusting weight 100g (F2) 200g (M1) 200g (M1) 300 g (M1) Stabilisation time 2 sec. (1 x 100g,1 x 200g) Weighing plate, stainless steel Ø 110 mm Ø 140 mm Ø 140 mm 172 x 142 mm Balance dimensions Mains adapter 180 x 80 x 23 mm 230 V, 50/60 Hz, balance 9 V DC, 400 ma Net weight (kg) 2,0 2,0 2,0 2,0 Air humidity Ambient temperature Authorised surroundings conditions for verifiable applications Units Vibration filter Interface Accu max. 80 % relative (non-condensing) 0 C to 40 C 10 C to 30 C g, ct yes RS 232 C interface (as option) as option 20 EW-EG-BA-defsinl-0215

KERN EW 1500-2M EW 3000-2M EW 6000-1M EW 750-C2M Readout (d) 0,01 g 0,01 g 0,1 g 0,01 ct Verification value (e) 0,1 g 0,1 g 1 g 0,1 ct Weighing range (Max) 1.500 g 3.000 g 6.000 g 750 ct Min. load (Min) 0,5 g 0,5 g 5 g 0,2 ct Taring range 1.500 g 3.000 g 6.000 g 750 ct Reproducibility 0,01 g 0,01 g 0,1 g 0,01 ct Linearity ± 0,02 g ± 0,02 g ± 0,2 g ± 0,02 ct Adjusting weight 1.000g (F2) 2.000 g (F1) 3.000 g (M1) 100 g (F2) Stabilisation time Weighing plate, stainless steel Balance dimensions Mains adapter 2 sec. Ø 140 mm Ø 140 mm 172 x 142 mm Ø 110 mm 180 x 80 x 23 mm 230 V, 50/60 Hz, balance 9 V DC, 400 ma Net weight (kg) 2,0 2,0 2,0 2,0 Air humidity Ambient temperature Authorised surroundings conditions for verifiable applications Units Vibration filter Interface Accu max. 80 % relative (non-condensing) 0 C to 40 C 10 C to 30 C g, ct yes RS 232 C interface (as option) as option EG-EW-BA-defsinl-0215 21

KERN EG 300-3M EG 600-2M EG 1500C2M Readout (d) 0.001 g 0.01 g 0.01 ct Verification value (e) 0.01 g 0.1 g 0.1 ct Weighing range (Max) 300 g 600 g 1500 ct Min. load (Min) 0.02 g 0.5 g 0.2 ct Taring range 300 g 600 g 1500 ct Reproducibility 0.002 g 0.01 g 0.01 ct Linearity ± 0.003 g ± 0.02 g ± 0.02 ct Adjusting weight internal internal internal Stabilisation time 3 sec. 2 sec. 3 sec. Weighing plate, stainless steel Balance dimensions Mains adapter Ø 110 mm Ø 140 mm Ø 140 mm 180 x 80 x 23 mm 230 V, 50/60 Hz, balance 9 V DC, 400 ma Net weight (kg) 2.0 2.0 2.0 Air humidity Ambient temperature Authorised surroundings conditions for verifiable applications Units Vibration filter Interface Accu max. 80 % relative (non-condensing) 0 C to 40 C 10 C to 30 C g, ct yes RS 232 C interface (as option) as option 22 EW-EG-BA-defsinl-0215

2 Unpacking and standard accessories Take the balance carefully out of the packing and store the plastic wrap for a possible future transport. The standard accessories consist of: Balance Weighing pan Weighing pan support External mains adapter Adjusting weight (test weight) only with models KERN EW. The models KERN EG possess an internal adjusting weight. Operating instructions 3 Setting up the balance Place the pan base packed with the weighing pan on the balance. Fix it on the shaft by driving the knurled nut in the centre. Place the weighing pan properly on the pan base. Place the balance on a firm surface. See also chapter 11. Drive the adjusting legs to centre the bubble in the circle of the level (front left in the housing). EG-EW-BA-defsinl-0215 23

4 External view Key functions ON/OFF ON/OFF key for lighting display Print Print key or data transmission key F Function key, to call various functions TARE Zeroing / Taring key parameter selection key 24 EW-EG-BA-defsinl-0215

Display panel 5 Installation Please note that your KERN balance is a precision weighing instrument. Even if the instrument is made for robust and continuous use, please handle it carefully and do avoid unnecessary use. The balance requires a warm-up time. The optimum weighing results are achieved when starting to used the balance only 5 minutes after turning it on. 6 Power supply Plug balance into a socket 230 V / 50 Hz. Do not connect it when there should be another mains voltage. Socket must be grounded as per VDE prescription. Inspection by authorised special electrical shop only. Plug the adapter cable on the back of the balance. Only then: Plug the given mains adapter (230 V AC / 9 V DC / 400 ma) in the socket. The balance is now in the Standby mode, see "Power Display *" Press now the ON/OFF key The balance performs now a self-check. After approx. 5-8 seconds the balance is ready to operate. EG-EW-BA-defsinl-0215 25

7 Declaration of conformity Declaration of conformity The electronic precision balances Type: KERN EW 150-3M KERN EW 300-2M KERN EW 600-2M KERN EW 1500-2M KERN EW 3000-2M KERN EW 6000-1M KERM EW 750C2M KERN EG 300-3M KERN EG 600-2M KERN EG 1500C2M EC type approval certificate number: T5026 Issued by: NMI correspond to the following EC directives: EC directive EC directive EMC (about the electromagnetic compatibility) Version 90/384/EWG Version 89/336/EWG Applied harmonised norms, in particular EN 45501, EN 50081-1, EN 50082-1 This declaration is only valid with the certificate of conformity by a notified body. This declaration ceases its validity at each changing of the above mentioned apparatus which is not in accordance with KERN. Date: 20 January 2000 Signature: Gottl. KERN & Sohn GmbH Managing Director Gottl. KERN & Sohn GmbH, Ziegelei 1, D-72322 Balingen-Frommern, Tel. +49-07433/9933-0,Fax +49-07433/9933-149 26 EW-EG-BA-defsinl-0215

8 Adjusting (CAL) 8.1 Adjusting for verification General Information Prior to the procedure of verification the balance has to be adjusted. See also section 8.2 Adjusting (CAL). After the successful adjusting it is necessary to make the adjusting possibility impossible on KERN EW balances. The switch for this step is located on the inside of the balance (beneath the housing, above the display) (only with models KERN EW). Blocking / Releasing of the adjusting function Remark: The adjusting is only possible when not being blocked by the adjusting switch. Switch to the right Switch to the left Adjusting function is blocked After successful adjusting the adjusting has to be blocked by this position of the switch. This setting has to be selected before starting to verify. Adjusting function is released The balance should be separated from the mains after each operation of the switches. After the verification the cap has to be secured by a verification mark against access. The balance is now prepared for the procedure of verification. EG-EW-BA-defsinl-0215 27

8.2 Adjusting (CAL) 8.2.1 Balance without internal adjusting weight (models KERN EW) With the given adjusting weight the accuracy of the balance is checkable and determinable at any time. Caution: With verified balances the possibility of adjusting is made impossible. See section 8.1 Adjusting for verification. Take account of stable ambient conditions. A warm-up time of approx. 30 minutes is necessary. Press F and hold pressed until CAL appears, then release the key. Press Tare and hold pressed. Immediately press F briefly and then also release TARE. Display.on 0 briefly flashes. Do not touch the weighing plate. Shortly after this in the display appears on F.5 Place the adjusting weight(s) carefully in the centre of the weighing plate. Display on F.5 flashes and shows briefly the weighing value of the adjusting weight. Take down the adjusting weight. The adjusting is completed. In case of an adjusting error or to interrupt the procedure of adjusting, quit by pressing S. Store the adjusting weight next to the balance for daily check on the accuracy of the balance. Note: Please handle the adjusting weight with care. Protect the adjusting weight from damage and dirt. Have it checked periodically. Store it next to the balance (to prevent from being mixed up). 28 EW-EG-BA-defsinl-0215

8.3 Balance with internal adjusting weight (model KERN EG) With the internal adjusting weight it is possible to newly set the accuracy of the balance at any time. Remark: The adjusting is on balances with internal adjusting weight also possible in the verified state. Take account of stable ambient conditions. A warm-up time of approx. 30 minutes is necessary. Press briefly S to start the automatic adjusting. Display S:A CAL flashes briefly. After a while in the display appears flashing CAL. 0 Then the display changes to CAL. on Turn the knob on the right hand side of the balance on position CAL. Then the balance display CAL. on begins to flash. Shortly after this the display shows CAL.oFF Turn the knob on the right hand side of the balance on position WEIGH. On the display appears End The adjusting is hereby accomplished. EG-EW-BA-defsinl-0215 29

9 Operating the balance 9.1 Warm-up time Optimum weighing results are being achieved when starting to operate the balance only 5 minutes after turning the balance on. 9.2 Power display If the symbol (*) is visible, the balance is provided with power via the mains adapter. By pressing the ON/OFF key the balance is in the weighing mode. Thus the power display in the balance display no longer is visible. It is recommended to turn the mains adapter off after having terminated to work with the balance. Bar Graph display The weighing range of the balance is separated in 20 graphic cuboids. If the balance is not loaded, the zero (0) is displayed in the graphic display. If the balance is loaded up to the half of its weighing range, 10 graphic cuboids are displayed. Note: If the tare weighing is carried out, the graphic weighing display continues to show the quantity of cuboids of the tare weight. 30 EW-EG-BA-defsinl-0215

9.3 Balance zero display By pressing the Tare key the balance is set to zero. On the display appears 0,00 g. Additionally, the symbol for the balance zero display (ZERO) 5 is displayed. 9.4 Tare weighing (taring) Place the tare cup on the weighing pan Press the tare key Balance display turns to 0,00 g The weight of the cup has been stored now internally. Put the load into the cup and read off the weighing value. The tare process can be repeated as often as wanted, for example to weigh in several components as a mixture (weighing in). The limit is reached when the whole weighing range is occupied. After taking down the tare cup, the total weight appears on the display as a negative result. Tare display By pressing the Tare key the tare weighing is started. On the display appears 0,00 g. Additionally, the symbol for the tare display 5 is displayed. EG-EW-BA-defsinl-0215 31

10 General program settings The balance leaves the factory with the factory settings being set. This is the standard configuration of the balance. It is marked by a *. It can be altered as follows: Press the F key for about 4 seconds until Func appears on the display. While releasing the key, 1. B.0. 0 appears on the display. By pressing the F key several times, the single functions are accessed. By pressing the Tare key several times, the individual setting within the single functions can be altered. To accept and quit the program mode, press the S key. The following changes are possible: F Tare Graphic weighing display 1. b0g 0 Auto Zero 3. A.0 0 Automatic shut-down (Accu only) 1* 1* 4. A.P. 0 Vibration filters 5. r.e. 1 2* 3 Data transmission (output format) only with built-in serial data interface (as option) 1* 6. o.c. 0 1 2 3 4 5 6 7* Balance display is turned off. Balance display is turned on. deactivated activated deactivated Balance is shut down after 3 minutes when not in use. Sensitive and fast Medium Insensitive, but slow No data transmission Continuous serial data transmission Continuous serial data transmission at stable balance display Data transmission after pressing of Print Automatic output at balance load, new output only after taking the weight down and applying a new load. One output at stable balance display One output at random stabilisation, not documented One output after pressing of Print at stable balance 32 EW-EG-BA-defsinl-0215

Baud rate 7. b.l. 1*. 2 3 Unit commutation 8. Set. 1* 2 3 4 Expanded readability 9. A.i. 0 1200 Baud 2400 Baud 4800 Baud g g/ct not documented not documented Readability 0,01 g Readability 0,001 g (only with model EG 300-3M) 1 Not documented 0. GLP 1 Always use this setting Not documented A. PrF. 3 Always use this setting EG-EW-BA-defsinl-0215 33

11 Important information These electronic balances are precision instruments. It is designed for use in a self-controlled electromagnetic environment. That means that in such an environment radio equipment, such as mobile phones, must not be used in direct vicinity. In case strong electromagnetic fields should arise, deviations of the indication are possible. Avoid disturbing environmental conditions such as currents and vibrations as well as a rapid change of the ambient temperature. If necessary readjust the balance after a change of temperature. Avoid high humidity, vapours and dust as the balance is not hermetically closed. Do not let the balance come into direct contact with liquids as these could enter the measuring cell. Therefore only clean the balance with a dry or damp cloth. Do not use solvents as varnished or plastic parts could be damaged. A warming up time of a few minutes after switching the balance on will stabilise the measuring values. Place the object carefully on the weighing pan. Avoid any constant load on the weighing pan even when out of use. Avoid shocks, thrusts and extreme impairments by all means. Remove spillages immediately. When the programme cycle is disturbed switch the balance off and then on again. Start the weighing operation again. Never use the balance in rooms where there is a danger of explosion. The serial version is not explosion-proof. Opening of the balance causes invalidity of warranty. Check the balance daily with the supplied check weight. If necessary adjust the balance. The warranty is nullified if the balance is opened. 34 EW-EG-BA-defsinl-0215

12 Trouble shooting No indication. The weighing display changes constantly. The balance is not turned on. The mains connection does not function (the cable is not connected, the cable is defective). The mains supply has broken down. Air movements Vibrations of the table or the floor. The pan is in contact with an alien element. The adjusting is no longer correct. The temperature varies strongly. Error messages o-err b-err u-err 1-Err 2-Err 3-Err 4-Err The weighing range is exceeded. Electronic error caused by electrostatic field. Check environment. If necessary, choose another location. The weighing pan does not lie on the pan support. Wrong adjusting weight (too light). The adjusting weight is too incorrect. At the beginning of the adjusting, a weight is on the balance. Grave error. CAL. OFF Error message only with models having an internal adjusting weight. The adjusting switch (right) is not in the WEIGH position. If other error messages occur, turn the balance off and on again. The weighing result is obviously wrong. If the error message still appears, please contact KERN. EG-EW-BA-defsinl-0215 35