Vapor Sorption Analyzer

Similar documents
Met One E-BAM Particulate Monitor

Using the Akta Prime plus October 22, 2012

Soil Water Characteristic Curve (SWCC) Using the WP4C

Operation of the Perkin Elmer TGA-GC/MS

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

256 Pneumatic Pressure Indicator

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Instruction Manual MediPrep 120

Relative Humidity Calibration Kit

Relative Humidity Calibration Kit

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.

English. Quick Guide MS-TS Precision and Analytical Balances

Pressure Dump Valve Service Kit for Series 3000 Units

User Manual. Precision and Analytical Balances ME-T

Automatic Powder Trickler by Adam MacDonald

Procedures for operation of the TA Instruments DSC

Using the UltraRAE. Firmware 2.35

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

[USING THE VITROBOT April 9, Using the Vitrobot

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

UsER manual for Watersens ph -REDOX

INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE. MODEL TB3/0.1mm

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

6900 Maintenance Instruction System Flush

INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB3

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

Standard Test Procedures Manual

QUICK START GUIDE TO DRINKING WATER MONITORING

User Manual. Quantos Automated Dosing Powder Module

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

User Manual. Quantos Automated Dosing Liquid Module

Pressure Dump Valve Service Kit for Series 2300 Units

ShellPa. Standard Mechanical Cell Stretch System Model No: NNMS Serial #: User Manual

PANACEA P100 LOW PRESSURE USER MANUAL

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

MILITARY SPECIFICATION POWDER, BLACK

GCMSD-Headspace Analysis SOP

The Decomposition of Hydrogen Peroxide

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

HYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

GE Measurement & Control

CircuFlow Quick Setup Guide

6800 Maintenance Instruction System Flush Procedure

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Standard Operating Procedure Porosity Analyzer - The Micromeritics Tri-Star II (surface area) with Micrometrics VacPrep 061 (Sample Degas System)

WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, PHONE #: (970) FAX #: (970) TO-Clean Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

AMT-Ex Dewpoint Transmitter

Air Displacement Pipetting Modules. Total Integrated Liquid Handling

VAPOMATIC ANESTHETIC VAPORIZER

EMISSION CHAMBERS. Bulk and Surface Emission Detection for the RAD7 User Manual

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

#LZ400 LEAKALYZER. Water Loss Sensor INSTRUCTION MANUAL Country Dr. #190 St. Paul, MN

Varian 3300 Gas Chromatograph Abbreviated Operating Instructions

Vibration isolation system 1VIS10W. User manual

Instruction Manual. Model DSP-Ex Portable Dewpoint Meter. Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England

Boyle s Law: Pressure-Volume Relationship in Gases

Low-Flow Purging Procedure with MicroPurge basics Equipment. MP10 Bladder Pump Controller MP15 Control. MP30 Drawdown Meter.

Instruction Sheet. Calibration of Multiple 1720 and FT660 Turbidimeters

CHM Introductory Laboratory Experiment (r17sd) 1/13

HoldUp Plus2. Safety Kit included: See additional instructions for installation. REAR WHEEL TRAY. BASE (1x) lock WASHER (1x) KEY (2x) SAFETY CLIP (1x)

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

TECHNICAL BULLETIN. TriControls. Control Materials for Liquid QC and Calibration Verification

Section 3- Repair and Calibration Procedures

1)! DO NOT PROCEED BEYOND THIS MARK

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

B. Assemble the Method-25 sample train with a heated probe/filter.

Table of contents. Table of contents 1. Installation 2. Introduction ( Display, monitor ) 3. Introduction ( Operating elements ) 4

PRACTICAL TIPS FOR TRACE-LEVEL OXYGEN MONITORING WITH ELECTRO-CHEMICAL SENSORS

PANACEA P200 STAINLESS STEEL USER MANUAL

ACV-10 Automatic Control Valve

HCMTCB ASPHALT CERTIFICATION KEY ELEMENTS LIST

Manual for continuous distillation

K-STATE GRAIN QUALITY RESEARCH PROGRAM STANDARD OPERATING PROCEDURES

Lab Equipment ANALYTICAL BALANCE

Manual of SF6 Comprehensive Tester

Agilent ICP-MS Interactive Troubleshooting tool for Plasma ignition problem

FRONT BOLT ACTION ASSAULT SHOTGUN

AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:

Cover Page for Lab Report Group Portion. Pump Performance

TapeStation Tips & Tricks

OPERATIONS CHALLENGE 2017

Unit 24: Applications of Pneumatics and Hydraulics

DURRIDGE STAINLESS STEEL SOIL GAS PROBE

Introduction. Check for the following items before use.

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Calcimeter Instruction Manual

to the LI-6400 Sensor Head

Float Operated Level Controllers

TEST FOR STABILOMETER VALUE OF BITUMINOUS MIXTURES

Lab 4: Transpiration

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

PERFORM Operating Document

PERFORM Operating Document

Transcription:

Vapor Sorption Analyzer Quick Start Guide

1. Getting Started Place the AquaLab VSA on a flat surface. Use the bubble level(figure 1: Adjustment and bubble level) and use the adjustable feet to level the instrument. The small rubber feet on the back of the lower plate are to prevent tip-over and do not need to be touching the table. Use the AquaLab VSA where environmental temperature and humidity remain fairly stable. Bubble Level Adjustment feet: Two on front and one on the middle back. Lower Block Figure 1: Adjustment and bubble level. The AquaLab VSA needs to be on a stable platform and evaluated to verify shipping did not damage the scale performance. To test scale stability: 1. Turn on the VSA and allow instrument to warm up for 2 hours. 2. Navigate to the Diagnostics screen in the Configuration menu and press. 3. Scroll down to the screen that shows the weight. Readings should vary no more than 0.5 mg.

4. Lightly tap the table with one finger. If the readings vary more than 0.5 mg after tapping, the table is probably too unstable for accurate weight readings during a test and will need to be made more rigid or another location found for this equipment. Contact your AquaLab distributor if the scale readings are unstable after placing the unit on a stable structure. Desiccant Cartridge Desiccant Receiver Black Valve Black Receiving Hole Figure 2: Desiccant installation Desiccant tubes are installed by orienting the tube so that the black colored valve inserts into the black receiving hole as shown in Figure 2. Before insertion make sure that the desiccant tube lid is firmly sealed onto the desiccant tube. (See Manual for instructions) Lift the tube into the area above the desiccant receiver and then insert the tube into the mating holes while shaking the tube slightly. Once in place, the desiccant tube is sealed for flow purposes and may move side to side if contacted.

Upper Horizontal Drilled Hole Water Fill Plug Water Tank Fill Extension Water Tank Drain Plug Fan Filter Figure 3: Tank fill extension Remove the black plug on the clear plastic tank fill extension located on the back right of the VSA. (Figure 3). Fill the tank with deionized water until full. Finger tighten the water fill plug once finished. To remove the water from the water tank, the water tank drain plug is used. Figure 3 shows the location of a filter that will need to be removed from time to time when dust builds up on it. The housing around the filter is a snap on housing that is easily removed.

Sample Cup Lid Only used for sample storage and must be removed during tests. Sample Cup Stainless steel cups are recommended. Plastic cups absorb moisture over time. Weighing Pan Air Cylinder Base Block Bore Figure 4: Sample cup and lower block assembly Figure 4: assembly illustrates the proper positioning of the parts in the lower block. The air cylinder is placed into the bore of the base block. It should slide into the block easily and settle at the bottom of the bore. The weigh pan connects to the scale and holds the sample cup. For best results, verify cleanliness of all parts. 2. AquaLab VSA Performance Verification overview AquaLab VSA performance and cleanliness should be checked frequently; before each isotherm test is recommended. Press until you are at the Measurement Tab. Use AquaLab Verification Standards to verify performance or adjust linear offset.

To verify, remove weigh pan and then place sample cup containing one of AquaLab s verification standards in sample chamber. Close lid and carefully avoid spillage; See Figure 5. Move latch left or press to start a reading. The pinwheel spins to indicate a measurement is running. The a w reading for the standard and the temperature displays when finished. Make sure the a w reading on the standard is within +/-0.005 of the correct a w for the standard. (+/- 0.02 if cap sensor is used) If an offset adjustment is needed, refer to chapter 7 in the user s manual. Lid Base Figure 5: Sample chamber 3. Sample Preparation Fill sample cup no more than half full (~7ml). Do Not Overfill! Sample size can be between 500 and 2,000 mg. We recommend 1000 mg. Ensure the rim and outside of sample cup are clean.

Ensure sample temperature is within 4 C of chamber temperature. 4. Starting a Test Before starting a test, set the Volatiles: Yes/No option in the configuration menu. If your sample has volatiles, select Yes otherwise select No. On the main screen, select the test wizard. Following several warnings, begin configuring the test by providing a name for the test using the arrow keys and then press. (The name of a previous test will appear by default.) Enter initial moisture content if known (optional). Press to continue or to go back. Setup each stage of the isotherm test. A stage is used to adjust the isotherm settings for an individual sample (up to 20 stages). Each stage is setup with the isotherm method (DDI or DVS) and the settings for that portion of the isotherm. Once a stage is created, it can be modified or deleted anytime before the test is started. i.e. For milk powder, Stage 1 could use the DDI method to ramp quickly from 0.1 to 0.4 a w and Stage 2 could use the DVS method to step from 0.4 to 0.8 a w slowly in 0.05 a w increments. To setup a new stage, select new and press. A screen with several parameters will appear. If a previous test has been run, the stages for that test will be listed by default. These stages can be used as-is or updated with new settings. If you need to delete a stage, go to the specific stage and press. Scroll down to the bottom of the stage settings select Delete and press. Select the isotherm method as either Dynamic Dew Point Isotherm (DDI) or Dynamic Vapor Sorption (DVS). DDI will create a dynamic isotherm and DVS will create a static or equilibrium isotherm. The other choices will adjust based on which method is selected.

For DDI method To choose the starting a w, press with Start highlighted and then cycle to the desired value using the up and down arrows. Any value between 0.03 and 0.95 a w can be chosen including current. Choosing current means that the stage will start at the initial a w of the sample. Press when finished. To choose the final a w, press with Final highlighted and then cycle to the desired value using the up and down arrows. Any value between 0.03 and 0.95 a w can be chosen including current (see current definition above). Selecting a final a w that is lower than the starting a w will result in desorption, while selecting a final a w higher than the starting a w results in adsorption. Press when finished. To choose the temperature of the stage, press with Temperature highlighted and then cycle to the desired temperature using the up and down arrow keys (hold down arrows for accelerated scrolling). You may choose any temperature between 15 and 60 C, 25 C is default. Each stage can run at a unique temperature. To choose the desired a w resolution, highlight Resolution press with Resolution highlighted and then cycle to the desired value using the up and down arrows. You may choose any value between 0.003 and 1.0 a w. The resolution for DDI determines the target a w resolution. Setting a higher resolution value makes the test faster, but decreases the a w resolution. We recommend a DDI resolution of 0.01 a w. To choose the air flow rate, press with Flow highlighted, and then cycle to the desired value using the up and down arrows. Any value between 10-163 ml/min can be selected. Higher flow rates will speed up the test, but may result in lower data resolution and non-equilibrium conditions. The default value of 100 ml/min is suitable for most products.

To choose to include a timeout setting, press with Timeout highlighted, and then cycle to the desired value using the up and down arrows. Any value between 5.0 min to 30 days can be selected. The timeout determines the maximum time allotted to move from the starting a w to the final a w (DDI only) and is optional. The default value is off, which means there is no timeout value. To choose to have the isotherm loop, press with Loop highlighted to toggle between on and off. Turning loop on causes the isotherm to automatically return to the start a w (with the same settings) once the final a w has been achieved. This would create both an adsorption and desorption curve (or vice versa depending on the starting direction). For DVS method To choose the starting a w, press with Start highlighted, and then cycle to the desired value using the up and down arrows. Any value between 0.03 and 0.95 a w can be chosen including current. Choosing current means that the stage will start at the initial a w of the sample. Press when finished. To choose the final a w, press with Final highlighted, and then cycle to the desired value using the up and down arrows. Any value between 0.03 and 0.95 a w can be chosen including current (see current definition above). Selecting a final a w that is lower than the starting a w will result in desorption, while selecting a final a w higher than the starting a w will result in adsorption. Press when finished. To choose the temperature of the stage, press with Temperature highlighted, and then cycle to the desired temperature using the up and down arrow keys. Any temperature between 15-60 C can be chosen. Each stage can run at a unique temperature. To choose the desired a w step, press with Step highlighted and then cycle to the desired value using

the up and down arrows. Choosse any value between 0.003 and 1.0 a w. The step setting for DVS determines the a w values for equilibration and consequently the resolution. If starting a w is 0.1 and has a step setting of 0.10 a w results in humidity being controlled to 0.1, 0.2, 0.3 up to the final a w, remaining at each level until either equilibrium is achieved based on the trigger value or it reaches the timeout value. Setting a higher value makes the test faster, but decreases the quantity of equilibtation points. To choose the trigger %dm/dt value that indicates equilibration, press enter with Trigger highlighted and then cycle to the desired value using the up and down arrows. The trigger can be shut off or be any value between 0.001-1%/hr. Choose the number of events required to meet the trigger value. The trigger value represents an acceptable change in mass per change in time to indicate equilibrium for a given step. Setting a higher value will make the test faster, but may not result in complete equilibrium. If the trigger is turned off, the sample will be held at each step for the time indicated by the timeout setting. To choose to include a timeout setting, press with Timeout highlighted and then cycle to the desired value using the up and down arrows. You can select any value between 5.0 min to 30 days. The timeout determines the maximum time allotted for each a w step NOT the time from starting a w to final a w. The default value is off, which means there is no timeout value and only the trigger value determines the end of step. If you set both a trigger value and timeout value, whichever VSA reaches first determines the end of step. To choose to have the isotherm loop, press with Loop highlighted to toggle between on and off. Turning loop on causes the isotherm to automatically return to the start a w (with the same settings) once the final a w has been achieved. This would create both an adsorption and desorption curve (or vice versa depending on the starting direction).

The delete entry is used to remove an unwanted stage. Follow the message on the screen to place an empty stainless steel cup in the chamber and seal it. Press to tare the cup. Follow the message on the screen to place the sample in the cup and press to weight the sample. Press to begin the test. 5. Running a water activity test (Can not be done when isotherm test is running) Remove the weighing pan. Press until you are at the Measurement Tab (2nd tab). Move latch left and/or press to start a reading. The pinwheel will spin indicating a measurement is running. The a w reading for the sample and the temperature will display when finished. To change between dew point and capacitive readings, you will need to toggle the Volatiles Yes/No option in the Configuration Tab. Volatiles = Yes g Capacitive Sensor Volatiles = No g Dew Point Sensor Note: Accuracy changes to +/- 0.02 when volatiles Yes is selected.

2365 NE Hopkins Court Pullman, Washington 99163 USA 1-509-332-2756 instruments@aqualab.com www.aqualab.com 14510 13-01-16