Uniflair LE TDAR-TUAR

Similar documents
The CWE / HWE-R Series: Overview. Frame and cabinet covering

Evaporator (DX) Freon Applications 1 12 Tons MHF

Product Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP

Product Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES

Ducted Reverse Cycle Air Conditioning of Distinction

AIR CONDITIONERS WA14**W SERIES

AIR CONDITIONERS WA14 SERIES

MAINLINE MLA14 AIR CONDITIONERS

DATA & FACTS Compressor-Condensing Unit GLCU BC1/2(.SL) Air-Cooled Compressor Condensing Unit for Outdoor Installation

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

TECHNICAL DESCRIPTION

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.

4SCU13 PRODUCT SPECIFICATIONS

FMU4X, FMC4X FMU4P, FMC4P

4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM ENHANCED AIR CONDITIONING DESIGN COMPONENTS WARRANTY COMPRESSOR CABINET COILS

BUBBLER CONTROL SYSTEM

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

LIEBERT DS TOP VIEW FRONT VIEW. This document has been generated on 22 September :18 PM (EST). Dry Weight (approximate) lb.

Product Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)

BUBBLER CONTROL SYSTEM

VARIABLE SPEED AIR CONDITIONERS

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

FA4B FB4B FC4C DIRECT EXPANSION FAN COIL. Sizes 018 thru 070. Form No. PDS FA4B Air Handling Technology At Its Finest

COMPACT Booster Sets Data Book 50Hz

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz.

market leading commercial and domestic ventilation with heat recovery Nilan VPM Active heat recovery and cooling (air/air)

Product Data. FA4B FB4B FC4C Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

APPLICATIONS. Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors.

Contents. Introduction Part 1 General Information Part 2 General Instruction Part 3 Outdoor Units Part 4 Installation...

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Crest Heating Boilers FBN(L) Series &

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.

VARIABLE AIR FLOW REGULATOR

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

High Pressure Breathing Air Compressors

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)

Semi-Hermetic compact screw compressors

Part 1 General Information Part 2 Outdoor Units... 8

USER S INFORMATION MANUAL

Commercial Standard and High-Efficiency Condensing Units

HOT SERIES (High Output Temperature) Geothermal Water to Water Heat Pump R-134A Refrigerant 2 Ton to 20 Ton Single Speed

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

OFFER / ANGEBOT / DRAFT Media Supply Module >MSM6-380< HYDRAULICS/PNEUMATICS. > Compressor unit incl. filling station to supply the modules

HumiSys HF High Flow RH Generator

SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA

MODBUS. Index Variable/BACnet Name Description Type Access Format Default Minimum Maximum MultiStat Value Multistate Text Inactive Text Active Text

4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP

Selection of ICF made easy Save even more time with ICF

Valve test benches. Systems overview

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

Pressure independent control valve (PICV) FLOWMATIC

Pneumatic high-pressure controller Model CPC7000

Pressure Automated Calibration Equipment

PressVal Pressurisation Units. Packaged Pressurisation Units with expansion vessels for heating systems.

Sales Office: Danfoss Expansion Valves. T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP

RPLA. Heat Pumps. Parts List 19-July-2011

African Development Bank Group

Refrigeration Scroll For Parallel Applications

Standard Chiller 1/4 compressors Manual version: /10/96

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and Position.

CNG FILLING STATIONS

GMD20..NL, GMD30..NL* GHV20..NL, GHV30..NL* GHV40..NL, GTKS20..NL* Series

CO 2 radial piston compressor (transcritical)

OC Panel High Limit Aquastat Kit, Manual Reset p/n

MAINLINE MLP14**A HEAT PUMPS

Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units)

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Screw Compressors 11-22kW

Chilled beam iq Star WEGA II

User Manual MFCS TM -EZ

CCT-7320/ROC-2313 Reverse Osmosis Controller

Centriflow Plus High-pressure plug fan - Technical Data

This parts list is current as of the above revision date. See for the current revision.

RS D RSF D with direct drive

Aquavar SOLO 2 Frequently Asked Questions

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

MINI-VERTICUS & VERTICUS THE NEXT GENERATION INDUSTRIAL COMPRESSORS FOR AIR, NITROGEN AND RARE GASES

CHECK VALVES APPLICATIONS

AIR COOLED SCREW WATER CHILLERS

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

MINI-VERTICUS & VERTICUS THE NEXT GENERATION INDUSTRIAL COMPRESSORS FOR AIR, NITROGEN AND RARE GASES

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION...

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Revision 1 AIR & WATER COOLED LIQUID CHILLERS MICRO BASED CONTROL SYSTEM WITH IPUII

Propane Conversion Kit Instruction

Pulsar/S Use & Maintenance manual

Adjustable swirl diffuser ODZA TECHNICAL DATA

CASED HORIZONTAL FURNACE COIL. Model CK3B. Form No. SS-CK3B-01 FEATURES

Frascold semi-hermetic compact screw compressors

Transcription:

Uniflair LE TDAR-TUAR Direct Expansion air-cooled units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDAR) > Upflow (TUAR)

Main Technical Features Microprocessor control Local or remote user terminal Regulation logic of cooling capacity and airflow integration Integrated LAN card for group connection Rotation and active stand-by management Remote on/off Modbus protocol interface Other external communication protocols: Bacnet, Lonworks, Trend, Metasys, TCP/IP, SNMP, and StruxureWare TM platform. Air-cooled Direct Expansion system Heat is extracted from the room and transferred to the outside air using aircooled refrigerant heat exchangers (condensers) The room unit and external condenser form an autonomous sealed circuit A wide range of configurations available Electronic Expansion Valve Controlled by the microprocessor and a dedicated software Increased cooling precision Increased energy efficiency of the cooling cycle Fans High-efficiency backward-curved Directly-coupled asynchronous motor Note: This configuration is shown only as an example. Downflow unit with backward-curved fans

Main Technical Features Cooling coil Elevated SHR and reduced pressure drops in the air section Made from copper tubes mechanically expanded on aluminum fins Hydrophilic treatment Air filters EU4-pleated air filters housed in a metal frame Dirty filter differential pressure switch Low airflow differential pressure switch Frame Selfsupporting frame in galvanized steel with panels. External panels coated with RAL9003 epoxy-polyester paint Internally lined with heat and soundproofing insulation. Electrical panel Situated in a compartment separated from the air flow Complying with 2006/95/EC directive and related standard Directives compliance 2006/42/EC, 2004/108/EC, 2006/95/EC, 97/23/EC, 842/2006/EC F-GAS regulation Metal frame air filter Construction Options Immersed electrode humidifier (D/U versions) Low surface temperature electrical heaters with extended fans, complete with double safety thermostat and manual resetting (T/H versions) Hot gas and hot water reheating External Accessories Remote, semi-graphic user terminal RS485 serial adaptor to communicate with external BMS LON FTT10 serial adaptor to communicate with external BMS managed with LON protocol TCP/IP serial adaptor to communicate with external BMS managed with SNMP protocol AFPS (Automatic Floor Pressurization System) that permits to adapt its availability as a kit with installation instructions Motorized damper Suction from the top or front discharge plenums Adjustable floor stands

Technical Data/1 TDAR-TUAR Model 0511A 0611A 0721A 0722A 0921A 0922A 1021A Fan Type EC Backward-curved centrifugal motor fan Power supply V/ph/Hz 400/3/50Hz Fans Nr. 1 1 1 1 1 1 1 Airflow m3/h 5833 5833 7933 7933 7933 7933 7933 N of compressors 1 1 2 2 2 2 2 Refrigerating Circuits 1 1 1 2 1 2 1 Gross Total Cooling Cap.(1) (2) kw 20,4 25,0 25,8 25,6 34,1 33,9 37,1 Gross Sensible Cooling Cap.(1) (2) kw 19,8 22,2 25,2 23.9 28,1 27,2 28,7 Height mm 1960 1960 1960 1960 1960 1960 1960 Length mm 1010 1010 1310 1310 1310 1310 1310 Depth mm 750 750 865 865 865 865 865 TDAR-TUAR Model 1022A 1121A 1122A 1321A 1322A 1422A 1622A Fans Nr. 1 1 2 2 2 2 2 Airflow m3/h 7933 12267 12267 12267 12267 16406 16406 N of compressors 2 2 2 2 2 2 2 Refrigerating Circuits 2 1 2 1 2 2 2 Gross Total Cooling Cap.(1) (2) kw 36,9 37,8 37,9 47,7 47,7 51,6 57,5 Gross Sensible Cooling Cap.(1) (2) kw 28,0 36,8 36,2 39,3 38,0 51,0 56,8 Height mm 1960 1960 1960 1960 1960 1960 1960 Length mm 1010 1720 1720 1720 1720 2170 2170 Depth mm 865 865 865 865 865 865 865 1.Gross Cooling capacities; fans must be deduced to obtain net cooling data. 2.Data refers to nominal conditions : room at 24 C- 50% RH, 45 C condensing temperature, and ESP = 20Pa.

Technical Data/2 TDAR-TUAR Model 1822A 2222A(3) 2242A(3) 2522A(3) 2542A(3) 2842A(3) 3342A(3) Fan Type EC Backward-curved centrifugal motor fan Power supply V/ph/Hz 400/3/50Hz Fans Nr. 2 3 3 3 3 3 3 Airflow m3/h 16406 21656 21656 21656 22046 22055 22055 N of compressors 2 2 4 2 4 4 4 Refrigerating Circuits 2 2 2 2 2 2 2 Gross Total Cooling Cap.(1) (2) kw 63,9 75,1 81,2 86,7 88,1 97,4 107,6 Gross Sensible Cooling Cap.(1) (2) kw 57,3 75,1 80,3 83,3 84,5 90,8 92,9 Height mm 1960 2150 2150 2150 2150 2150 2150 Length mm 2170 2580 2580 2580 2580 2580 2580 Depth mm 865 865 865 865 865 865 865 TUAR Model 2222A 2242A 2522A 2542A 2842A 3342A Fans Nr. 3 3 3 3 3 3 Airflow m3/h 22154 22154 23467 22467 23068 23068 N of compressors 2 4 2 4 4 4 Refrigerating Circuits 2 2 2 2 2 2 Gross Total Cooling Cap.(1) (2) kw 75,4 82,7 86,6 87,5 97,9 108,2 Gross Sensible Cooling Cap(1) (2) kw 75,4 81,8 85,5 86,4 93,8 95,6 Height mm 1960 1960 1960 1960 1960 1960 Length mm 2580 2580 2580 2580 2580 2580 Depth mm 865 865 865 865 865 865 1.Gross Cooling capacities; fans must be deduced to obtain net cooling data 2.Data refer to nominal conditions : room at 24 C- 50% RH, 45 C condensing temperature, and ESP = 20Pa. 3.Data refer to downflow unit