Drag racing system HL190 User Manual and installation guide

Similar documents
Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

STAND alone & p.c. VERSION

INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK

ELIMINATOR INSTRUCTIONS Table of Contents

Tournament Manager: Running a VEX IQ Event - Beginner

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

WELCOME TO THE REVOLUTION

HyperSecureLink V6.0x User Guide

For running only the scoresheet application without any video features only some very basic hardware / software requirements have to be fulfilled:

1. Hardware Hardware Connection... 2 Connection Diagram... 3 DIP Switch Settings & 10 PIN Button Layout... 4

SPLIT HOPKINSON PRESSURE BAR OPERATIONS MANUAL 5/9/2014

Microsoft Windows Software Manual for FITstep Stream Version 4

TdC 8000 Page 1. Version: E Page 1

BASnet LightiView Install Guide

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

Digi Connect ME 9210 Linux: 2 nd serial over FIM

Lockstep. Reference Manual. Last updated on September 23, Figure 53, LLC

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

1/4 & 1/8 Mile Asphalt Track Dirt / Sand Track Mud Track Snowmobile Track R/C Car Track Custom Track Systems Windows Software

XC2 Client/Server Installation & Configuration

Helium Level Measurement Unit

RM-80 respiration monitor

Setting Up the Ingenico isc250 Pinpad via USB

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules

Microfluidic Demonstration

OMNISPORT 2000 SWIMMING QUICK REFERENCE

Operating instructions Electrical switching facility pco

SDM-2012 Docking Station Standalone Configuration Operator s Manual

Perfect Golf Quick Start Guide

DDR Dive Data Recorder Manual - Rel /12

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

DIVE MEET SCORING INSTRUCTIONS. Day before meet

The Race Director. IPICO Integration Direct Connect [IPICO INTEGRATION]

1. SYSTEM SETUP AND START TOURNAMENT... 8

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

TdC 8001 Page 2. Version:E Page 2

1. Hardware...2. Hardware Connection... Connection Diagram... DIP Switch Setting... & 0 PIN Button Layout...

Annual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5

TESLAGON. ShotHelper Manual. How to install and use the Program. Version /30/2014

Overview. Front Panel: Keypad and Display

Product Overview. Product Description CHAPTER

TR Electronic Pressure Regulator. User s Manual

Impulse G3. Race System. User Guide V0412

CONSUMER MODEL INSTALLATION GUIDE

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

Instruction Manual. BZ7002 Calibration Software BE

Steltronic StelPad User Guide

TdC 8000 plus. English

Setting up the Ingenico isc250 Pinpad via USB in Windows 8

Tru Flight TRUFLIGHT INSTALLATION GUIDE TRUGOLF.COM

Presents the following instructional slide show:

1. Hardware Bookkeeping & Adjustment...7. Access Flow Chart... 7 System Adjustment... 8 Chance Adjustment... 9 Touch Screen Calibration...

Wickets Administrator

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

Pneumatic high-pressure controller Model CPC7000

AIR FLOW ANEMOMETER INSTRUCTION MANUAL

Design Envelope Booster. Sequence of operation

APA software instruction manual

SENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide -- Windows. Version 2.0 Published October 17, ReefNet Inc.

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

SWIM MEET MANAGER 5.0 NEW FEATURES

RUNNING A MEET WITH HY-TEK MEET MANAGER

ROTAX GLOBAL APP GUIDE. (revised ) GRAND FINALS EDITION

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

This addendum describes the back pressure control implementation if FuelCell Version 4.1a and later.

MANUAL TIMING. PRACTICAL GUIDE

Center Command Version 3. Operations Manual

eflo ELECTRONIC GAS FLOW METER OPERATIONS MANUAL

Version-E E100930

Mac Software Manual for FITstep Pro Version 2

FRDS GEN II SIMULATOR WORKBOOK

ALGE DIVE! ALGE. ALGE-TIMING GmbH & Co

Pneumatic high-pressure controller Model CPC7000

Stand-Alone Bubble Detection System

AX5000 Operational Manual

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Track and Field Interface

LEGO Engineering Conferences ROBOLAB and MINDSTORMS Education Version 4.5 March 2008

Oxygen Meter User Manual

Dive Planet. Manual. Rev Basic User Interface. 2 How to organize your dives. 3 Statistics. 4 Location Service and Map View.

PRODUCT MANUAL. Diver-Mobile for Android

HumiSys HF High Flow RH Generator

Boyle s Law: Pressure-Volume Relationship in Gases

AUTO PUMP STATUS CENTER

Drag Racing Scoreboards

MULTITUBE BUBBLE TUBE BY ROMPA (U)

Optical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB

Soft Systems. Log Flume - 1. Enter Specification. Activity One ACTIVITIES. Help. for Logicator

IBU3 Manual Addendum 1

Software Manual for FITstep Pro Version 2

Software for electronic scorekeeping of volleyball matches, developed and distributed by:

[MYLAPS INTEGRATION]

Panther 5 Acute Care Ventilator

Gas Analyzer for TC Sensors (CO2, H2, N2) Series 62101, 64101, Operating Manual

1. Hardware Bookkeeping & Adjustment Access Flow Chart... 6 System Adjustment... 7 Chance Adjustment... 8 Touch Screen Calibration...

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

Transcription:

Drag racing system HL190 User Manual and installation guide Version 10/2015 TAG Heuer Timing Page 1 / 14

1. Global This software controls the whole Drag racing installation HL190. Combined with the Chronelec Elite V3 software, manage your complete championship. Manage 2 lane with up to 4 light trees (2 for each lane) Generate different light sequences : - Sportsman tree - Pro Tree - Custom (set your own sequence) - Random sequence between 0,2 and 3 sec Use a remote display for spectators Manage Jump starts and reaction time Manage up to 2 timing devices Chronoprinter 540 or 545 over Network TAG Heuer Timing Page 2 / 14

1. Software - Menu presentation 1.1. The Interface Information Datagrid displays : Bib number Official Start time Driver/Rider Start time Reaction time Real time Light status START Light sequence RESET System (switches all remaining lights OFF) 1. SETTINGS Menu to connect Light tree, Timing device and Modulo Displays 2. OPTION Option to connect our Modulo display HL950 as Jump start display Print run displayed in datagrid as a pdf file Reset and empty datagridview 3.? About version information and access to user manual TAG Heuer Timing Page 3 / 14

2. Hardware presentation 1.1 The light tree 17cm Pre-stage / Stage 3 Amber starting lights 100cm Green (start) light Red light (Jump start) The Christmas tree is direct powered by the control box 1.2 The control Box TOP VIEW light power supply right lane light control left lane light control TAG Heuer Timing Page 4 / 14

SIDE VIEW right lane left lane staging beams sockets Pre-Stage Stage Pre-Stage Stage BOTTOM VIEW 230V 50Hz socket serial I/O RS232 socket to computer impulse output socket to Chronoprinter 540/545 TAG Heuer Timing Page 5 / 14

1.3 Staging beams The staging beams are mounted on a special bracket which respects the 7 distance for each detector. Pre-stage and stage beam are crossing the track, 7 inches apart. The beams are mounted at 2 inches about the track surface and broken by the cars front tyre. Ensure that the beams and reflector are correctly aligned. 6 inches 2 inches Max 10 meter (33 ft) When the wheels cross the first beam, the Pre-Stage signal will light like the NHRA christmas tree: 14cm 14cm Pre-Stage beam: A light beam-to-photocell connection in each lane that triggers the small pre-stage lights atop the Christmas Tree. The pre-stage lights signal to drivers that they are close to staging, approximately seven inches behind the starting line. TAG Heuer Timing Page 6 / 14

When the wheels cross both beams, all lights are ON The vehicle is staged If the vehicle is deep staged, following sign will blink on corresponding lane. This occurs no incidence on the timekeeping. TAG Heuer Timing Page 7 / 14

3. Get started This software runs only with Ethernet connection in parallel of a timekeeping software. We recommend to use a (Gigabit) switch in order to connect the Chronoprinter on the network. A. Launch the software 1. Connect your timing devices Use an Ethernet cable to connect the Chronoprinter 540 or 545 on your network. Ensure that all IP address are on the same gateway and no double IPs are in conflit. Enter the IP address of your device (default address is 192.168.1.50) Click on connect. Until the socket is open and the printer of your CP540/545 switched on, a confirmation message will be printed. Set the trigger information of the timing photocells (we recommend to use the HL2-31 or HL2-35) Set the input information into which channel the Christmas tree signal has been connected. That s the Green light trigger 2. Connect the Christmas tree and the control box Connect the Christmas tree on the control box (power + data). The control box is driven by a serial communication port RS232. All available COM port will be listed. Select correct COM port and click Connect Start Lights. The control box gives an acknowledge and will confirm the communication status. TAG Heuer Timing Page 8 / 14

3. Connect your Jump start Modulo HL950 Connect the Modulo over RS232 or RS485 (please refer to Modulo display user manual). Even our radio HL675 could be connected directly on your laptop. All available COM port will be listed. Select correct COM port and click Connect. You can select the image to display in case of jump start. The image will be the same for both lanes. Then enter the serial number of the Modulo Display which will be for each lane. TAG Heuer Timing Page 9 / 14

B. Elite V3 setup Elite V3 should run on the same network as the Christmas tree controller. Connect your device over TCP and select the Chronoprinter 540 protocol (the same as the CP545). The race settings are as you connect all device like or as in our example bellow: LANE 1 (left) LANE 2 (right) TAG Heuer Timing Page 10 / 14

For the speed, just set the channel and distance between both photocells for each lane You can change field text in SETTINGS OPTIONS EDIT - Edit intermediate fields text For more informations, please consult Elite V3 user manual. TAG Heuer Timing Page 11 / 14

4. Other features A. Extended display If you run an extended windows display. This signal can be converted to Analogic or digital with a special converter and be broadcasted on several TVs around the track or a video wall All timing information will be displayed. You can even customize your screen with 3 different logo. All *.jpg, *.png files are accepted and auto-sized to fit on the screen. B. Export to pdf Creates a printable pdf file of your datagrid. Hands on: You can copy the complete grid to a Excel worksheet. Click on the top left hand corner in order to select the complete grid. Hit Control + V Key in order to copy. Control + C to paste in your excel. C. Clear Datagrid TAG Heuer Timing Page 12 / 14

5. Technical Specification To be completed Control Box - Power supply: 110/230V 50/60 Hz - Christmas tree Power supply: 12V 10A included in control box Warranty : One year after delivery of your purchase The warranty is null and void under the following conditions: - Poor maintenance and obvious physical damage - Input or Outputs damaged by poor connection - If the device was opened without factory authorization TAG Heuer Timing Page 13 / 14

TAG Heuer PROFESSIONAL TIMING 6A Louis-Joseph Chevrolet 2300 la Chaux-de-Fonds Switzerland Tel : 032 919 8000 Fax : 032 919 9026 E-mail: info@tagheuer-timing.com Http: //www.tagheuer-timing.com TAG Heuer Timing Page 14 / 14