Health & Safety Policy and Procedures Manual SECTION 34 HYDROGEN SULFIDE (H2S) PROGRAM

Similar documents
Hydrogen Sulfide (H2S) Program for Construction

Hydrogen Sulfide (H 2 S) Program

Hydrogen Sulfide - Health Effects, Detection and Exposure Prevention

Title: Benzene Awareness Effective Date: 11/14/2014 Control Number: THG_0037 Revision Number: 1 Date: 10/22/2015 Annual Review Completed: 5/13/2015

Section 37 Brieser Construction SH&E Manual

BP U.S. Pipelines & Logistics (USPL) Safety Manual Page 1 of 8

Issue Date 11/21/13 Revision Date 01/04/18 Benzene

Juler Group. Presents. Hydrogen Sulfide (H 2 S) Safety. Juler Group Juler Group Incorporated

H2S (HYDROGEN SULFIDE) SAFETY TRAINING

HEALTH AND SAFETY MANUAL

H 2 S in the Oilfield Fact Sheet. Introduction to H 2 S. Where does H 2 S come from? Hazards of H 2 S

Air Monitoring and Detection at Crude Oil Emergencies MODULE 5

HYDROGEN SULFIDE EMPLOYEE TRAINING

HEALTH AND SAFETY MANUAL

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

CONTENTS. 9. Opening of gas systems containing H 2 S. 1. Introduction. 8. Protection of Personnel.

ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM

WorkSafeBC Occupational Health & Safety (OH&S) Regulation: Hazardous Atmospheres and Confined Spaces in Compost Operations

Confined Spaces. 1. Definition Permit/Non-Permit

HYDROGEN SULFIDE. In the Oilfield

Tennessee Tech University Environmental Health and Safety

Respiratory Protection

AMMONIA REFRIGERATION IN WAREHOUSES

Safety Tips from the WorkSafe People. Building a Safety Program for Your Organization

CONFINED SPACE PROGRAM

Respiratory Protection Program 29CFR

Safety Data Sheet. Address GHS Precautions If skin irritation occurs: Get medical advice/attention

Product Name:Heat Sink Compound 1801 Morgan Street MSDS Number:148

SAFETY DATA SHEET FOR FALK GMAX 6000

Hydrogen sulfide (H 2 S) is an invisible hazard that can be released and produced during industry processes, such as drilling.

EMA, Inc. SITE SAFETY PLAN

Safety Data Sheet. Address

A. Evaluation of the written program

Safety Data Sheet. Eye: Exposure to airborne concentrations above statutory or recommended exposure limits may cause irritation of the eyes

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

In addition to this SOP, the policies and procedures of each operating company will be strictly observed by Rockwater personnel.

3 Choosing the Right Respirator

SAFETY AND HEALTH STANDARD CONFINED SPACE ENTRY REQUIREMENTS Effective Date: 06/10/10 Standard: 16.2 Document Number: KUCSH0038 Rev: 07

Material Safety Data Sheet

Section 1: PRODUCT AND COMPANY IDENTIFICATION. Section 2: COMPOSTION / INFORMATION ON INGEDIENTS

MATERIAL SAFETY DATA SHEET

Material Safety Data Sheet

HAZARDOUS WASTE OPERATIONS AND EMERGENCY RESPONSE

JOSOP 500 Hydrogen Sulfide Program and Procedure. JOSOP 500 Hydrogen Sulfide Program and Procedure

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities.

Title: Hexavalent Chromium Compliance. Preparer: Owner: Approver: Texas EHS EHS Team Member

MATERIAL SAFETY DATA SHEET

Introduction to Confined Space Safety OR-OSHA

MATERIAL SAFETY DATA SHEET

Intermountain Specialty Gases 520 North Kings Rd, Nampa, Idaho Phone: Fax:

Material Safety Data Sheet

Key Technology, Inc. Confined Space Entry Program. July, 2017

RULE 36 & H 2 S SAFETY

CONFINED SPACE PROGRAM

Safe Work Practices / Procedures / Instruction CONFINED SPACE

SAFETY DATA SHEET. P.O. Box 4272 CHEMTREC: (800) Houston, TX KRONOS: (800) Customer Service: (800)

EMERGENCY PHONE: or (651) (24 hours)

Safety Data Sheet. Address

Standards of Practice Respiratory Protection: Appendix C

BOSS LUBRICANTS: MATERIAL SAFETY DATA SHEET

: DIAMOND - PLATE LIGHT REFLECTIVE

Employee Safety Toolkit. Employee Safety Toolkit. Notes:

TAMMSFLEX NS PART A Version 1. Print Date 06/10/2008 REVISION DATE: 02/07/2008

EMERGENCY PHONE: or (651) (24 hours)

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET

SECTION 1 - PRODUCT AND COMPANY IDENTIFICATION

3.0 Manage. hazardous substances. risks IN THIS SECTION:

Material Safety Data Sheet

SAFETY DATA SHEET Isopropyl Alcohol 70% Product Number: 32

Material Safety Data Sheet

Personal Protective Equipment 29 CFR 1926

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET Complies with OSHA Hazard Communication Standard 29 CFR

Recommended Facilitator Notes: (read the following text out-loud to participants while showing this slide)

PRODUCT NAME : PLASTER OF PARIS UPC NUMBER : , , , PRODUCT USE/CLASS : Plaster of Paris

RESPIRABLE CRYSTALLINE SILICA PROGRAM July 2018

Personnel Protective Equipment

EMERGENCY PHONE: or (651) (24 hours)

SAFETY DATA SHEET MATERIAL AND MANUFACTURER IDENTIFICATION HAZARD(S) INDENTIFICATION. Product Name: Odor Zyme Revision Date: 5/19/2015

Zinc Oxide. Material Safety Data Sheet

M a t e r i a l S a f e t y D a t a S h e e t

CONFINED SPACE WRITTEN PROGRAM

MATERIAL SAFETY DATA SHEET 3M Peroxide Cleaner Concentrate (Product No. 34, Twist 'n Fill System) 06/24/13

Total Systems Technology Inc. Address 65 Terence Drive, Pittsburgh, PA Phone Number Emergency Phone Number

Material Safety Data Sheet

U. S. OIL & REFINING CO. M A T E R I A L S A F E T Y D A T A S H E E T

SAFETY DATA SHEET. Asphalt Rubber Blend. Section 1. Identification. Section 2. Hazards Identification

DIGISAN HEALTHCARE HAND SANITIZER FOAM. Use only for the purpose on the product label.

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEET. Product & Company Identification

Atmospheric Hazards PROGRESSIVE SAFETY SERVICES LLC

: INTEGRAL WATERPELLER POWDER

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

Health & Safety Policy and Procedures Manual SECTION 33 BENZENE AWARENESS PROGRAM

MORTAR COLOR#719 LIGHT CHOCOLATE -12/2.5 Version 1 Print Date 07/03/2007 REVISION DATE: 06/16/2005

MATERIAL SAFETY DATA SHEET

Transcription:

SECTION 34 HYDROGEN SULFIDE (H2S) PROGRAM

1. REGULATORY STANDARD: OSHA - 29 CFR 1910.1200 and 1926.55 Purpose: The purpose of this program is to inform interested persons, including employees, that Maul Electric, Inc is complying with OSHA's Gases, Vapors, Fumes, Dusts, and Mists standard, Title 29 Code of Federal Regulations 1926.55 and other OSHA rules as needed to ensure that no employee is exposed to inhalation, ingestion, skin absorption, or contact with any material or substance at a concentration above those specified in the "Threshold Limit Values of Airborne Contaminants for 1970" of the American Conference of Governmental Industrial Hygienists found in Appendix A of 29 CFR 1926.55. This program will address potential exposures to Hydrogen Sulfide. To achieve compliance Maul Electric, Inc must first implement all feasible administrative and engineering controls. However, when such controls are not feasible, employees will use protective equipment provided by Maul Electric, Inc at no cost to the employee or other protective measures to keep the exposure of employees to air contaminants within the limits prescribed in Appendix A of 29 CFR 1926.55. All equipment and technical measures used to achieve compliance will first be approved for each particular use by a competent industrial hygienist or other technically qualified person. 2. Administrative Duties: This written safety program is for Maul Electric, Inc employees and subcontractors construction work sites. The Site Supervisor is the program coordinator/manager and is responsible for its implementation. 3. Scope: Maul Electric, Inc. has chosen to establish a Hydrogen Sulfide Awareness Program for emergencies that could arise from exposure to Hydrogen Sulfide. 4. Physical and Chemical Characteristics 4.1. Sulfur and Sulfur Compounds may be present in crude oil as hydrogen sulfide (H2S), as compounds (e g mercaptans, sulfides. disulfides, thiophenes, etc.), or as elemental sulfur. Each crude oil has different amounts and types of sulfur compounds, but as a rule the proportion stability and complexity of the compounds are greater in heavier crude-oil fractions. 4.2. As part of the work of Maul Electric, Inc our employees may be exposed to H2S especially when working in confined spaces or refineries. Hydrogen sulfide is a primary contributor to corrosion in refinery processing units and piping. Other corrosive substances are elemental sulfur and mercaptans. Moreover, the corrosive sulfur compounds have an obnoxious odor. 4.3. Hydrogen sulfide is a toxic, colorless, with the odor or rotten eggs at low concentrations, is soluble in water and is flammable.

5. Health Effects 5.1. Inhalation, ingestion, and contact with are all methods by which H2S can affect the body. The effects may range from irritation of the eyes, nose, and throat; to temporary loss of smell. Headaches, dizziness, and upset stomach are more intense symptoms caused by higher concentrations. However, inhalation of high concentrations of H2S may cause instant paralysis of the respiratory system causing loss of consciousness and death. In concentrations of H2S at 1000 to 2000 ppm even a single breath may cause coma and may be fatal. Because of its extremely serious and/ or fatal potential, any employee believed to be exposed to H2S shall immediately notify the Supervisor or Manager. 6. General Requirements. Maul Electric, Inc will establish Hydrogen Sulfide operational procedures through the use of this document. Permissible Exposure Levels (PEL) While not definitive, H2S levels below 10 ppm appears to cause little short term effects. When H2S level are unknown, respirators shall be used. Current OSHA standards are: 20 ppm Ceiling Level 50 ppm Maximum allowable peak for 10 minutes with no other exposure Current NIOSH standards are: 10 ppm PEL averaged over 10 minute period 50 ppm area shall be evacuated 7. Exposure detection, assessment, and monitoring 7.1. Maul Electric, Inc. Site Supervisor shall conduct personal or area sampling for hydrogen sulfide to measure worker exposures. Air sampling is needed to measure worker exposures and select appropriate engineering controls and respiratory protection. Where data is collected it must be retained to support negative exposure assessments. Maul Electric, Inc conduct both initial and periodic air monitoring 7.2. Maul Electric, Inc will further perform air monitoring as needed to measure the effectiveness of controls and as required under our written excavation procedures. 7.3. Maul Electric, Inc will utilize direct reading instruments (4 gas meter) and colorimetric tubes for quantification of exposures to Hydrogen Sulfide. Signs and symptoms of exposure are as follows: Short Term Effects: 0.13 ppm Threshold of odor detection 0.77 ppm Faint, but readily perceptible odor 4.6 ppm Easily noticeable odor

10 ppm Eye irritation, soreness, redness, burning 27 ppm Strong, unpleasant, but not intolerable odor 50 ppm Irritation & dryness of nose, throat, and airways cough, shortness of breath, pneumonia 100 ppm Immediate irritation of eyes and respiratory tract 150 ppm Sense of smell may be paralyzed 200 ppm Headaches, dizziness, nausea 500 ppm Unconsciousness and death within a few minutes may be no warning odor 1000 ppm Immediate loss of consciousness and respiratory paralysis leading to death 7.4. Personal or area monitors that alarm when PEL exceeds the preset level of 20 PPM for 1910 or 10 PPM for 1926. 8. Employee Notification and Signage. This employer shall post signs at entrances to regulated areas. The signs shall bear the following legend: DANGER HYDROGEN SULFIDE TOXIC FLAMMABLE - NO SMOKING AUTHORIZED PERSONNEL ONLY RESPIRATOR REQUIRED 9. Method of Compliance. Exposures to Hydrogen Sulfide (H2S) can generally be controlled through the use of engineering controls, work practices, and personal protective equipment. Engineering controls are hazard controls designed into equipment and workplaces. Work practices are procedures followed by employers and workers to control hazards. The following engineering Controls, work practices, and personal protective equipment should be used when dealing with H2S. Ventilate spaces to mitigate accumulation of hydrogen sulfide or other gases. Notify the Site Supervisor upon detection of H2S If the potential for exposure exists and assessment of levels cannot be performed, assume the Permissible Exposure Limit is being exceeded, and wear a NIOSH approved supplied air respirator. For persons escaping or providing emergency help, an approved self-contained breathing apparatus or airline respirator with escape SCBA shall be used. Should an alarm sound on an H2S detector, immediately evacuate the area, and notify your supervisor.

10. Training. 10.1. Maul Electric, Inc will provide our employees workers with regulatory training that includes requirements of the substance specific requirements. This will include health effects, background information, engineering controls, ppe, medical surveillance, communication of hazards, hygiene, and methods of compliance at a minimum. 11. Medical surveillance 11.1 Although Maul Electric, Inc understands that medical examinations should always supplement effective gas, vapor, fume, dust, and mist monitoring and controls, and never substitute for them, we provide medical examinations for all workers who may be exposed to Hydrogen Sulfide at or above the respective PEL for greater than 30 days per year, found in 29 CFR 1926.55. 11.2. These medical examinations are provided by professional healthcare organizations at no cost to the employee and shall include all components as required under particular substance standards. 12. Record keeping 12.1. Maul Electric, Inc knows record keeping is critical to our safety and health program. Our record keeping tasks, at a minimum, include: Exposure monitoring data 30 Years Medical surveillance data Duration of employment plus 30 years 13. Emergency, Spill and Leak Procedures. 13.1. Employer should be aware of Owners contingency plan provisions. Employees must be informed of the plan of the host facility and aware of additional plant safety rules