Pressure Independent Control Valves

Similar documents
Pettinaroli Pressure Independent Control Valves. EvoPICV

Pressure Independent Control Valves

Pressure independent control valve (PICV) FLOWMATIC

PCMTV Pressure independent control valves, DN20-DN32 with integrated flow limiter for thermal emitters and differential pressure regulator

Ballorex Dynamic Description. Versions. Benefits. Balancing

PCTV/PCMTV/PCTVS15-25

VFPIP/VFPIM/VFPI 15-25

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

differential pressure regulating valve - threaded

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Pressure Independent Control Series

Harmony. Pressure Independent Balancing and Control Valve

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

CAST IRON VALVES FLOAT VALVE

RadKits (Piping Packages)

Scald Protection Three-Way Thermostatic Mixing Valve

Water Pressure Reducing Valves

Full Range Pressure Compensating Variable Flow Control

BEFORE SALES AFTER SALES

2-port and 3-port valves PN 16

SINGLE VALVE WITH LOW-FLOW BYPASS

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

PRESSURE INDEPENDENT CONTROL VALVE (PICV)

Scald Protection 3-Way Thermostatic Mixing Valve

2-port seat valves PN25 with externally threaded connections

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

553 Series.

3 & 4-Way Mixing & Diverting Valves

CALEFFI. Ball zone valves. series /03 GB

3776B FLANGED PRESSURE INDEPENDENT CONTROL VALVE (P.I.C.V.) PN 16 TECHNICAL DATA SHEET. Main features:

Pressure Independent Control Valve (PICV) Fig DN15-32

Pressure independent balancing and control valve AB-QM DN

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Hydronic Systems Balance

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

WaterSource Heat Pump Hose Kit Performance Specification-Summary

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

3-port seat valves with externally threaded connection, PN 16

DS06D,G Dial Set Pressure Regulating Valve

Cim 787 Variable orifice balancing valve

Pressure Regulators Pressure regulation to maximize steam system efficiency

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

DS05C,D,G Dial Set Pressure Regulating Valves

Differential Pressure Control Valve. Passim

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Two-port valves, male threaded, PN25

HERZ-Motorised flow controler

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

D05T Compact Design Pressure Regulating Valves

ACTUATORS AND INSTRUMENTS

KTM 50 (DN ) Installation, maintenance and operating instructions

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

TECHNICAL DATA. Q = C v P S

An Overview of Types of Isolation Valves

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

VBS-9263 Series. Application. Features. Applicable Literature

2-port and 3-port seat valves, PN16

TECHNICAL DATA. Q = C v P S

TA-FUSION-P. NPT threads / ANSI flanges

PROCESS MONITORING AND CONTROL

TECHNICAL DATA. Q = C v P S

Lesson 6: Flow Control Valves

HORIZONTAL BLADDER TANK

Fundamentals of Hydronic Design. Fundamentals of Hydronic Design. Fundamentals of Hydronic Design. Fundamentals of Hydronic Design

Float Operated Level Controllers

The Ins and Outs of I/P Transducers

[Instruments for vacuum measurement, checking and adjustment] 3

FILTER BYPASS CONTROL

Bermad Pressure Reducing. Model: 42T

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

By-pass valves Series 466 Thermatic - Series USVR

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

V43 Pressure Actuated Water Regulating Valve

BACK PRESSURE / SUSTAINING

Pressure Reducing Valve DMV 755

TECHNICAL DATA. Q = C v P S

4400 TwinHybrid Gas Seal

CASH VALVE TYPE KP BACK PRESSURE VALVES

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Automatic balancing valves ASV

D05 Pressure Regulating Valves

VERTICAL BLADDER TANK

TECHNICAL DATA. Q = C v P S

GW DRY PIPE VALVE INSTALLATION & OPERATION 100mm (4 ) 150mm (6 )

BERMAD Irrigation. Automatic Metering Valve (AMV) 900-D Series. Basic Valve ??????? IR-900-D.

TECHNICAL DATA. Q= Cv S

BACK PRESSURE / SUSTAINING

PRESSURE INDEPENDENT CONTROL VALVE (P.I.C.V.) PN 25 TECHNICAL DATA SHEET. Approved by: Main features:

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control.

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

TECHNICAL DATA. Q = C v P S

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

Transcription:

Pressure Independent Control Valves

Pressure Independent Control Valve The Terminator PICV Pressure Independent Control Valve is a combined constant flow limiter and full stroke, full authority, equal percentage temperature control valve. The Terminator PICV is suitable for use in variable and constant temperature systems and may be used as a constant flow limiter in constant volume systems (without an actuator head) or as a true PICV in variable volume systems. Operating principles The Terminator PICV valve is made up of three main parts: 1. differential pressure regulator 2. regulating valve for flow adjustment 3. flow pre-setting knob Differential pressure regulator The differential pressure regulator is the heart of the pressure independent control valve. By keeping a constant differential pressure across the control valve, constant flow and full authority temperature control can be achieved. Incoming pressure P1 is transmitted to the top face of the diaphragm, while outgoing pressure P3 is transmitted to the underside of the same diaphragm. A constant effective differential pressure is maintained between P2 and P3. As P1 increases relative to P3, it acts on the diaphragm closing the shutter (A) against a seat (B), thereby lowering the effective differential pressure. As P1 decreases relative to P3, the diaphragm acts to open the shutter (A) from the seat (B), thus increasing the effective differential pressure. The diaphragm acts against a spring in order to balance the pressure control and stop the diaphragm oscillating. 1 2 3 Functional schematic P1 A B P2 P3 Regulation valve Water flow through a valve varies as a function of the area of passage and the pressure differential across that valve. Due to the incorporation of the differential pressure regulator, the differential across the valve seats P2 P3 is constant, meaning that flow is now only a function of area of passage. Setting and maintaining a flow rate value is also possible. The control valve presents an equal percentage characteristic. Adjustment knob The maximum flow can be preset, choking the outlet section of the control valve, by using the graduated adjustment knob. The percentage value, indicated on the scale, matches the maximum flow rate percentage. This value can be changed by turning the adjustment knob until it reaches the selected position (matching the percentage indicated on the scale). A locking mechanism stops the valve set values from being changed inadvertently.

A PICV replaces a traditional control valve on a terminal unit (FCU, CB, AHU). It limits flow rate irrespective of pressure and offers the possibility to modulate the flow rate (according to room temperature) by using a proportional thermostat or BMS system. Dynamic curve Provides constant flow at any pump head Q 100% 70% 50% % actuator stroke 3.63 PSI Start-up P1 - P2 The dynamic curve can be initially limited using a graduated pre-setting device; then the flow can be further adjusted by means of the control valve, which is positioned by the actuator. Control valve Pre-setting Control curve Changes design flow according to control logic of BMS Kv% 100% 90% 80% 70% 60% ON-OFF 50% 40% 30% 20% Equal percentage curve n(eq) = 3.9 10% 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Actuator / valve stroke %

91 Series 93 Series 1/2 thru 3/4 3/4 thru 1-1/4 Compact version Available with FIP x FIP threads Flexible version Available with double union ends (male, female, or sweat) Manual flow setting device Removable diaphragm for flushing, maintenance and trouble shooting FLOW RATE DIAPRAGHM Flow rate can be adjusted without taking the actuator off the valve. Diapraghm is one solid piece, resulting in easier handling and maintainance. Actuator compatibility chart Thermal electric Electromotive Actuator compatibility chart Thermal electric Electromotive On/Off Floating On/Off Floating Proportional 120V Proportional 120V Proportional 120V Proportional 120V

85 Series 1-1/4 thru 2 Unique in the world: integrated flushing bypass mode Solid and reliable characterized control ball valve Double union end connection for total flexibility Characterized profile / full port profile Manual flow setting device OPERATION MODE FLUSHING MODE Control valve is fully open, controlling the flow through a profiled ball and a 90 rotating actuator. Control valve is rotated by 180, with a profiled opening outside of the flow path. The valve now has full port passage, allowing twice the maximum flow, for proper flushing and cleaning. Actuator compatibility chart 90 Rotary actuator Proportional 90 Rotary actuator floating 110V 90 Rotary actuator spring return 110V

94F Series 2 thru 6 FEATURES Intelligent actuator with user-friendly interface for flow setting. Selectable linear or equal percentage control characteristic. Ductile Iron body. Flanged connections to ANSI standards. Maximum flow up to 660.43 GPM. SMART Actuator Flow rate can be easily set from the on-board user interface. Compatible with most commonly used control signals: Proportional (current or voltage control) 3 point floating ON/OFF 4 20 ma position feedback signal as default option, for total remote management.

PRODUCT Size Flow range (GPM) 91/93/85 SERIES 94F SERIES mm 15 20 25 32 40 50 50 65 80 100 125 150 in 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2" 2 1/2" 3" 4" 5" 6" Qmin.20.44.97 1.19 3.96 14.53 8.81 8.81 13.21 24.22 39.63 39.63 Qmax 3.43 9.69 11.89 26.42 39.63 79.25 88.06 132.09 132.09 242.16 528.34 660.43 Fluid Cold/hot water Temp. (fluid) 41 ~ 248 F Differential pressure 2.90 ~ 87 PSI range Material Body Brass / Ductile iron Diapraghm EPDM Connection 4.35 ~ 87 PSI Ductile Iron Threaded / union end Max operating stat360 PSI ic pressure Flanged 230 PSI Fully automatic assembling machine. Extreme precision and high reliability eliminate human error. Every valve goes through three different pressure tests and is then marked with a unique product code. HCi reserves the right to change the described products and the relative technical data at any time and without prior notice. HCi makes every attempt to ensure all information within this document is accurate. However, the company does not accept any liability for incorrect information published within this document. Please contact us at csr@hciterminator.com for questions or more information.

7243 Miller Drive, Warren, MI 48092 www.jomarhydronics.com phone: (586) 268-1220 fax: (586) 979-8315 LIT-JH-PSB