Calorimeter Selection Criteria

Similar documents
Calorimeter Selection Criteria

6200 Isoperibol Calorimeter Model Number: 6200

6200 Automatic Isoperibol Calorimeter Calorimeter with 1108 Oxygen Bomb, Bucket and 1757 Printer


Parr Instrument Company

Automatic Isoperibol Calorimeter Operating Instruction Manual For models produced after October M

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

DANGER WARNING IMPORTANT

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

Technical Data for Alicat MS Series Mass Flow Meters

Calcimeter Instruction Manual

Pneumatic high-pressure controller Model CPC7000

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Gas Laws Chapter 14. Complete the following pressure conversion. Be sure to show how units cancel.

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Instrumental Technique GAS CYLINDER

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

Gas Laws. Figure 1: Experimental Set-up with Leveling Bulb. GCC CHM 151LL: Gas Laws GCC, 2019 page 1 of 8

AUTOMATIC VAPOR PRESSURE TESTER REID METHOD, DEMI SIZE MODEL AVP-30 INSTRUCTION MANUAL. Rev

Both physical and chemical effects come into play either separately or in combination.

DTG - LCD Digital Temperature Gauge USER MANUAL

M-06 Nitrogen Generator (Nitrogen Making Machine)

PREPARATION AND PROPERTIES OF ATMOSPHERIC GASES I: Carbon Dioxide and Oxygen

Instrument Operating Manual

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

Before you start sampling, be sure to read

MATERIAL SAFETY DATA SHEET

Welcome to the LESER Seminar, Taipei 28. June Design_of_safety_relief_valves_250804_Cal

Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes

Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq)

Gas Pressure Regulator HON 200

Alkylphosphines. Storage and Handling Recommendations

Stirred Reactors and Pressure Vessels

Pneumatic high-pressure controller Model CPC7000

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

QUICK START GUIDE TO DRINKING WATER MONITORING

High Pressure Equipment Pressure Vessels and Reactors Index

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Model PDT Dewpoint Transmitter

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

GAS LAW WORKSHEET 1 KEY

Gas-Detection Instruments

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

User Manual. Quantos Automated Dosing Liquid Module

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

AMENDMENTS TO THE IMSBC CODE AND SUPPLEMENTS

SAFETY DATA SHEET. In accordance with 29 CFR Section 1. Identification of the substance or the mixture and of the supplier

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq)

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

MAPP Gas. Material Safety Data Sheet

Chapter 13 Gases. H. Cannon, C. Clapper and T. Guillot Klein High School. Pressure/Temperature Conversions

The Discussion of this exercise covers the following points:

Tank Blanketing Pressure Regulators RHPS Series

User Manual. Quantos Automated Dosing Powder Module

R: The Ideal Gas Constant Pre-Lab Assignment

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

SAFETY DATA SHEET. In accordance with 29 CFR Section 1. Identification of the substance or the mixture and of the supplier

Safety Data Sheet. according to Regulation (EC) No 1907/2006. Alpine Hydrauliköl HLP 32

Pressure Gauges. Version 2018 Revised 01/2018

PERFORM Operating Document

Class 2 Gases Learning Tool

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

Safetygram #4 Gaseous Hydrogen

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

HumiSys HF High Flow RH Generator

Pressure measurement. Pressure gauges

800.Keen.Gas

Standard Operating Procedure (SOP) Compressed Gas Cylinders (Original SOP from Eastern Washington University)

Chemistry HP Unit 6 Gases. Learning Targets (Your exam at the end of Unit 6 will assess the following:) 6. Gases

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Material Handling and Storage of compressed gases and Air equipment

for the of and the EM55-1

Discovery HP-TGA 75/750. Site Preparation Guide

ANALOX O2 PORTABLE OPERATORS MANUAL

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Focus on VOC Emissions Reduction Using an Oxygen Based Inerting Control System For Inert Gas Blanketing of Chemical Process Vessels

This test shall be carried out on all vehicles equipped with open type traction batteries.

Chemistry - Scale-up F.32. Lara TM - Controlled - Lab Reactor. The Concept

Instruction Manual Updated 7/26/2011 Ver. 2.2

Hands-On Experiment Density and Measurement

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Best Practice Guide, Servomex 2700

UsER manual for Watersens ph -REDOX

Air Operated Hydraulic Pumping Systems to 50,000 psi

Safety Data Sheet. according to Regulation (EC) No 1907/2006. Freezer BR

HI 2314 HI 2315 HI 23151

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

Rotational Viscometers RP1 RP2

Instruction presentation Special valves

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

STANDARD OPERATING PROCEDURES

PERFORM Operating Document

VALVE MANUFACTURERS ASSOCIATION API 622 API 624

Transcription:

Selection Criteria Bulletin No. 105 Factors which influence the selection of a calorimeter. There are a number of factors which should influence a user in his or her selection of a calorimeter. In general, the following four areas will help define the correct calorimeter choice. 1. Precision 2. Workload 3. Type of Analysis: including Test Method, Sample Size and Sample Characteristics 4. Budget Precision Some instruments, by design, are able to provide data with greater precision than others. Instruments may be classified based on their expected performance and this classification is used to define limits by which data can be assessed. Parr Model Sigma or Expected Accuracy Instrument (Benzoic Acid, 1.0g) Class 6300 Automatic Isoperibol 0.10% 11373 ± 34 Btu/lb 6200 Isoperibol 0.10% 11373 ± 34 Btu/lb 6100 Compensated Jacket 0.20% 11373 ± 68 Btu/lb 1341 Plain Jacket 0.30% 11373 ± 102 Btu/lb 6725 Semi-micro 0.40% 11373 ± 137 Btu/lb TechNote 105 1/24/06 Page 1

Standard methods usually define a level of precision and/or accuracy, and therefore the method parameters must be considered. Precision and accuracy in relation to instrumentation is discussed further in Tech Note 100 Precision and Accuracy Assessing Your and must be studied and understood in order to select the most appropriate calorimeter. Workload The 6300 Automatic Isoperibol is designed to handle a large volume of samples. Loading of the sample involves a simple 1/8 th turn of the bomb head in the unit. The unit then automatically fills the bomb and bucket, ignites the sample, monitors the temperature rise and flushes the system once the reaction is complete. Users will find that they can operate multiple calorimeters with ease. The operator time per test is estimated to be 1 minute and therefore it is possible for one operator to manage multiple units simultaneously. The 6200 Isoperibol and the 6100 Compensated Jacket can analyze just as many samples per instrument as the 6300 calorimeter; however, there is additional operator time per test and therefore fewer instruments can be operated at the same time. The user will need to fill and rinse the bomb as well as fill and drain the bucket. This requires repetitive action and therefore is recommended for a smaller number of samples. The operator time per test is estimated to be 6 minutes. The 1341 Plain Jacket requires significant user time. Along with filling and rinsing the bomb and filling and draining the bucket with water, the user must record the temperatures during the course of the reaction. The estimated time that the user will spend with this instrument is 25 minutes per test. This process can be simplified for the user by adding the 6772 Calorimetric Thermometer. The thermometer will ignite the sample after the established preperiod and record the temperature change. It will also determine the energy equivalent factor of the system after standardization and apply the heat leak TechNote 105 1/24/06 Page 2

correction to subsequent samples. (See Manual 202M, Introduction to Calorimetry for more information on standardization). Type of Analysis The Parr 6300 Automatic Isoperibol and the 6200 Isoperibol utilize a controlled water jacket. The water jacket is maintained at a fixed temperature, completely surrounding the bomb and bucket. Many standard methods require a water jacketed system such as ASTM D5865 and DIN 51900. If that is the case, the user s choice will be reduced to these two models. The 6200 calorimeter is able to provide the highest level of precision to the user. This is possible because each component of the system can be controlled by the operator. For example, the manual release of the bomb allows the user to have complete control over the exhaust of the vessel. This may be critical when analyzing the subsequent combustion products. Many such analytical methods are discussed in manual 207M, Analytical Methods for Oxygen s. The 1108 series and 1136 oxygen bombs are designed to handle approximately 1 g of a sample that liberates 5000 8000 calories using an oxygen charging pressure of 30 atm. The 1108P Oxygen is a version of the standard 1108 that it is constructed with a semi-permanent fuse wire to be used with cotton thread in place of the more traditional thin gauge fuse wire. The 1108R Oxygen is designed with a compression ring seal rather than an o-ring and utilizes the same semi-permanent fuse design found in the 1108P. Specific calorimeters are required for some of these bomb types as outlined in the table below. Alloy 20 Cb3 is the standard alloy of construction for the 1108 Oxygen Combustion and the 1136 Oxygen Combustion. This alloy is resistant to sulfuric and nitric acid, common by-products of the combustion process. Alloy G30 is recommended for use with samples that contain a higher TechNote 105 1/24/06 Page 3

level of fluorine or chlorine as well as being resistant to sulfuric and nitric acid. s constructed of this alloy are marked with CL. Finally, the choice of bomb style may affect the calorimeter chosen. choice is dictated by sample size and alloy of construction. For example, the Parr 1109 Semi-micro Oxygen is designed for small samples such as marine biology or ecological studies. It may also be used when sample size is limited. This 22 ml bomb will handle samples that range from 25 to 200 milligrams, liberating 52 to 1200 calories when burned in oxygen, using initial pressures up to 35 atmospheres. Outputs of up to 2400 calories can be accommodated if the sample is self-oxidizing, provided it is burned in an inert atmosphere and does not produce gas. On the other end of the Parr bomb family spectrum, the Parr 1104 Oxygen is designed for combustion tests of explosives and other fast burning, high energy samples, that burn with extreme violence. The 1104 Oxygen is also recommended for use with materials whose combustion characteristics are unknown or unpredictable. The 1104 Oxygen is a heavy-walled, 240 ml vessel. It will handle samples liberating up to 12,000 calories using an oxygen charging pressure up to 45 atm (665 psig). Samples of smoke powder weighing up to 4 grams have been burned in this bomb, but the requirements for safe operation vary so widely with different materials that it is difficult to make general statements regarding allowable sample size. The following table highlights the different bomb choices for the Parr line. TechNote 105 1/24/06 Page 4

6300 6200 6100 1341 6725 1136/ 1136CL X 1108/ 1108CL X X X 1108P/ 1108PCL X X X 1108R/ 1108RCL X X X 1104 X X X 1109 X X X Budget Price will often be a deciding factor in the purchase of a calorimeter and will, of course, be taken into account. For current pricing or additional assistance on choosing the appropriate calorimeter, please contact the sales department at Parr Instrument Company, parr@parrinst.com. TechNote 105 1/24/06 Page 5

Characteristics 6300 Automatic Isoperibol Overview 6200 Isoperibol 6100 Compensate d Jacket 1341 Plain Jacket 6725 Semimicro Operator Time per Test 1 Minute 6 Minutes 6 Minutes 25 Minutes 6 Minutes Repeatability (%RSD) 0.10% 0.10% 0.20% 0.30% 0.40% Type Isoperibol Isoperibol Compensated Static Static Number of vessels Up to 4 Up to 4 Up to 4 1 1 Closure Type Quick-lock Screw Cap Screw Cap Screw Cap Screw Cap Tests per Hour 6-8 as 4-8 as 4-8 as equipped equipped equipped 2 3 Type & Semi-Fixed Cylinder/ Bucket Head & Bucket & Bucket & Bucket Dewar Flask Bucket Fixed Fixed Bucket Filling Automatic Manual Manual Manual Manual Oxygen Filling Automatic Semiautomatiautomatic Semi- Manual Manual Washing Automatic Manual Manual Manual Manual Program Modifications None Memory 1000 Tests 1000 Tests 1000 Tests None 1000 Tests Printer Ethernet or Ethernet or Ethernet or Connection RS232 RS232 RS232 None Balance Connection None Network Connection Ethernet Ethernet Ethernet None Ethernet Temperature Resolution 0.0001ºC 0.0001ºC 0.0001ºC 0.002ºC 0.0001ºC Environmental 15-30 º C 15-30 º C 15-30 º C 15-30 º C 15-30 º C Conditions <80% <80% <80% <80% humidity humidity humidity humidity Utilities Oxygen Purity 99.5% 99.5% 99.5% 99.5% 99.5% DI, Distilled or DI, Distilled or DI, Distilled or DI, Distilled or Water Purity tap water at tap water at tap water at tap water at 85 ppm or 85 ppm or 85 ppm or 85 ppm or DI, Distilled or tap water at 85 ppm or TechNote 105 1/24/06 Page 6

Please note that the 1109 semi micro oxygen bomb is available in the model 6725 Semimicro Oxygen and also in a conversion kit for the model 6200 or 6100 calorimeters: 6269 Conversion Kit including semi-micro oxygen bomb with combination valve 6269A Conversion Kit including semi-micro oxygen bomb with manual valve PARR INSTRUMENT COMPANY 211 Fifty-Third Street Moline, Illinois 61265 USA Phone 309/762-7716 Fax 309/762-9453 http://www.parrinst.com E-Mail: parr@parrinst.com TechNote 105 1/24/06 Page 7