Digital Automatic Blood Pressure Monitor

Similar documents
Automatic Blood Pressure Monitor

Check following components! Vérifier les composants suivants! Digital Automatic Blood Pressure Monitor Model M3 Instruction Manual

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

Digital Automatic Wrist Blood Pressure Monitor Model R6 Instruction Manual. English Français Deutsch Italiano Espanõl Nederlands Русский

Automatic Blood Pressure Monitor Model M6 Instruction Manual

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing

Model M3 Intellisense

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing

Wrist Blood Pressure Monitor Model R2

Instruction Manual. Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

Model MIT Elite Plus

Check following components!

Contents. Safety Notice. Wrist Type

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

SpotArm Type Blood Pressure Monitor. Model i-q142

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Manual Inflation Blood Pressure Monitor Model M1 Instruction Manual. English Français. Deutsch Italiano Español Nederlands Русский Polski Magyar

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

MODEL CH-432B INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. - Eng 1 - English Español Português Deutch. Italiano Français CH-432B

REF CH-302B IDENTIFICATION OF PARTS

Digital Blood Pressure Monitor. Model UA-787

REF CH-602B IDENTIFICATION OF PARTS

705CP-II. Automatic Blood Pressure Monitor & Printer. Mode d emploi page 67 Istruzioni per l uso pagina 89

MEDICARE 60. Semi-automatic upper arm blood pressure monitor. Instruction manual

Digital Blood Pressure Monitor for the Upper Arm INSTRUCTION MANUAL

English Español Português Italiano Deutch Français INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR MODEL CH-656C. - Eng 1 -

Semi-Automatic Blood Pressure Monitor with Memory

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Step Counter Walking style One

Fully Fuzzy Auto Digital Wrist Blood Pressure Monitor. tensio control. INSTRUCTION MANUAL Model GP-6220

Auto Arm Blood Pressure Monitor

Digital Blood Pressure Monitor. Model UA-705. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni 1WMPD B

VER: A00. Model No:BA2010

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

Oregon Scientific Wrist Blood Pressure Monitor (BPW211)

User Manual. Hopkins IMPACT Digital Wrist BP RELATED ITEMS. Item #526014

Sports Wrist Digital Blood Pressure Monitor Item #

Step counter. Walking style. Instruction Manual 1 EN. Gebrauchsanweisung 37 DE Manuale di istruzioni 55 IT IM-HJ-304-E-02-08/ B

Instruction Manual. Auto Inflate Blood Pressure Monitor

6833_INSTRUCTIONS MANUAL DIGITAL WIRST BLOOD PRESSURE

Talking Wrist TypeBlood Pressure Monitor. Talking Wrist Type Blood Pressure Monitor Model: BPW810. User Manual

Talking Wrist Style Blood Pressure Monitor Model INS-LAB-RevB08

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

ACCUSTRIDE ACCUSTRIDEFM. Digital Clip-on Pedometer WC153. Digital Clip-on Pedometer WC154 ENGLISH

Owner s Manual. EZ Health TM Platinum Talking Automatic Wrist Blood Pressure Monitor ABP-A3

GentleTemp 510. Digital Ear Thermometer

Fully Automatic Blood Pressure Monitor

TD-3140 Blood Pressure Monitor. Owner s Manual

Blood Pressure Monitor

5 series Blood Pressure Monitor

Instruction Manual. Automatic Blood Pressure Monitor for Arm - Voice Prompt Function Announces Measured Values HB-ZA310V

Operating Instructions Instrucciones de funcionamiento

Instructions. Upper Arm Blood Pressure. Model EW3153

TD-3140 Blood Pressure Monitor. Owner s Manual

Wrist Type Blood Pressure Monitor

Oregon Scientific Wrist Blood Pressure Monitor (BPW120)

Blood Pressure Monitor

Blood Pressure Monitor

Blood Pressure Monitor

INSTRUCTION MANUAL. OMRON Digital Automatic Blood Pressure Monitor. Model HEM-907

SBC 21. Electromagnetic Compatibility Information

Blood Pressure Monitor

Owner's Manual. Wrist-type Fully Automatic Blood Pressure Monitor. Contents. Safety Notice. Model BP2116. Document No. Version: REV

Contents. Helpline No. UK/Northern Ireland , Rep. Ireland Web Support Model Number:

LD22. Digital Blood Pressure Monitor Instruction Manual

premium wrist blood pressure monitor

Blood Pressure Monitor

LD6. Digital Blood Pressure Monitor Instruction Manual

Blood Pressure Monitor

3.1.3 Weight. Frequency. Weight is obtained at the baseline examination and annually. Equipment

GoWISE USA R Blood Pressure Monitor Wrist Type. Instruction Manual

MODEL CH-485E INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. English Español Português Deutsch. English Español Português Deutch Français

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

Instructions for use. 3year. Wrist MOBIL BASIS. The monitor for first users To be used on the wrist. Also suitable for: WARRANTY. Clinically validated

Fully Automatic ihealth Track Connected Arm Blood Pressure Monitor USER MANUAL

Module No GETTING ACQUAINTED GENERAL GUIDE TIMEKEEPING

LD7. Digital Blood Pressure Monitor Instruction Manual. Ciśnieniomierz elektroniczny automatyczny LD Instrukcja Obsługi ENG POL

Digital Blood Pressure Monitor Model UA-621 Instruction Manual

Instruction Manual. Wrist Blood Pressure Monitor with Advanced Positioning Sensor (APS ) Model HEM-650 ESPAÑOL ENGLISH

REF CH-308B INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR IDENTICATION OF PARTS Eng 1 - Exhaust button Air connector Pumping bulb tube

Professional Blood Pressure Monitor HBP Thank you for purchasing this OMRON Professional Blood Pressure Monitor.

INSTRUCTION MANUAL DIGITAL BLOOD PRESSURE MONITOR

Model UA-705. Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Instruction Manual. S&S Tradings

INSTRUCTIONS. Manual Home Blood Pressure Monitor MODEL Stethoscope Chestpiece. Cuff. Bulb

boso Germany Do you? Premium quality essgeräte für die Selbstmessung I use equipment of BOSCH + SOHN to measure blood pressure.

VIDEO TUTORIAL: greatergoods.com/0605

Owner s Manual & Safety Instructions

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form

Model UA Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

INSTRUCTION MANUAL. OMRON IntelliSense Blood Pressure Monitor. ModelHEM-907

Content

Blood Pressure Monitor Instruction Manual

Arterial Puncture Wrist. Instruction Manual

HJA-313-AP_A_M09_ pdf. Instruction Manual. Activity Monitor. Model HJA-313

WARNING: EXPLOSION HAZARD

Circulation and Respiration: Vital Signs Student Version

Transcription:

Digital Automatic Blood Pressure onitor. Instruction manual page 1 Gebrauchsanweisung Seite 17 Gebruiksaanwijzing pagina 32 ode d emploi page 49 anuale de instructone pagina 65 anual de instrucciones pagina 81 I-HE-780-E-02-10/2011 1637848-2E

English. Introduction The ORON measures your blood pressure and pulse simply and quickly from the arm, without the use of an inflation bulb or stethoscope. The measurement values are stored in the memory of the ORON. The ORON includes the standard cuff for arm circumferences ranging from 22 to 42 cm. Table of contents 1. How to obtain meaningful blood pressure readings 2 2. Overview 3 3. Preparation 4 3.1 Insert the batteries 4 3.2 Control functions 4 3.3 Set date and time 5 3.4 Connect cuff 6 3.5 Fit cuff 6 4. Operation 7 4.1 easurement 7 4.2 Read display 9 5. emory 10 5.1 Recall previous values 10 5.2 Erase memory 11 6. Storage 12 7. Error: causes and rectifications 13 8. aintenance and spare parts 14 9. Technical data 14 10. General information about blood pressure 15 1

English 1 How to obtain meaningful blood pressure readings General This manual contains important information for safe use of the ORON. Follow this manual to prevent wrong measurement values, injury and damages. The ORON is not suitable for measuring the frequency of cardiac pacemakers. Consult your doctor during pregnancy, arrhythmia and arteriosclerosis as this can influence the measurement. Avoid eating, drinking (alcohol), smoking, doing sports and taking a bath before measurement. Be calm and relaxed before and during measurement. You should never change the dose of medicines prescribed by your doctor. Store the ORON in a dry, closed place with a temperature between -20 C and 60 C. Remove the batteries if you do not intend to use the ORON for 3 months or more. Tips for use Check your blood pressure at least twice a day (before breakfast, after work). Use the ORON only for yourself. easure your blood pressure before taking an antidepressant. Do not discard the air plug. When using the AC adapter, keep the batteries in the main unit. Use both the AC adapter and the batteries to extend battery life. Do not measure your blood pressure while you are in a vehicle. Always measure on the same arm. Wrap the cuff around your arm before start of measurement. Caution Only the ORON cuff can be used on this device. Other cuffs must not be attached. Operating temperature between 10 C and 40 C. Operating environment must be free from excessive vibrations, shocks, electrical noise, corrosive gas, etc. Stay out of sunlight during measuring. Keep portable phones 5 meters away during measurement. Do not wrap the cuff around any object other than your arm. Do not fold or crush the cuff and the air tube. Do not drop the ORON. 2

English 2 Overview A B D. C F E L K H G J A Display blood pressure B Display pulse, date and time C emory buttons ( / ) D Date/time setting button E Start button F On/off button G Cuff H Air tube J Air plug K Air jack L Battery compartment 3

English 3 Preparation 3.1 Insert batteries 1 Slide off the battery cover. 2 Insert four batteries as indicated in the battery compartment and close compartment. Caution! Use four identical 1.5V batteries type AA! 3.2 Control functions A B D. C F E A Display blood pressure B Display pulse, date and time C emory buttons ( / ) D Date/time setting button E Start button F On/off button 4

English 3.3 Set date and time At the first time you set the ORON the factory settings (0.00-1/1-2003) will be displayed. Another time the actual date and time will be displayed. Note: use the grey-coloured button to carry out the instruction. 1 Press on/off button. 2 Press date/time setting button for 2 seconds to proceed to year setting. Note: use a thin stick to press date/time settings button. AP AP 3 Press memory buttons ( / ) to set the year. Note: keep memory button down to fast forward. Note: if display reaches 2030, it will return to 2003. Press date/time setting button to proceed to date setting. 4 Use memory buttons ( / ) and date/time setting button to set successively month, hour and minutes. 5

English 3.4 Connect cuff P. P Air jack 1 Insert air plug in air jack. 3.5 Fit cuff 1-2 cm 1 Bare your arm. Caution! Push up your sleeve: avoid constricting the blood flow! Caution! Do not inflate the cuff when not wrapped around the arm! 2 Open the cuff with right hand and cover the cuff over your left upper arm. 6

English Note: keep marked edging on the inside of your elbow joint. Note: keep the tube even with your middle finger. Note: for right arm use, keep the tube under your elbow and parallel with your little finger. 3 Hold the cuff, wrap it around your arm. Caution! Be sure the cuff fits closely; do not pinch your arm! 4 Operation 4.1 easurement Q R W X U S T V Y Z Q Systolic blood pressure in. R Diastolic blood pressure in. S Heart symbol: flash - measurement takes place, light up - measurement finished. T Battery exhausted: batteries are weak/exhausted. U Inflation: cuff inflates and measurement starts. V Deflation: measurement finished and cuff deflates. W emory: stored measurements displayed. X Average: average value of last 3 measure ments displayed. Y Pulse: heartbeats per minute. Z Date/time. 7

English Caution! Allow an interval of at least three minutes between two successive measurements! 1 Sit comfortably at a table with your feet flat on the floor and rest your arm on the table. 2 Relax your arm and turn your palm upward. Caution! Cuff at heart height during measurement! 3 Press on/off button. Caution! Wait for zero and the heart symbol to continue! Caution! Do not remove cuff during inflation! 4 Press start button and release within 3 seconds. Note: the unit inflates the cuff. If required, the unit automatically increases the pressure by 30. Caution! Sit still, do not move or speak! 8

English Note: Wait for automatic deflation. 5 If your systolic blood pressure is known to be more than 220, press and hold the start button until the monitor inflates 30 or 40 higher than your estimated systolic blood pressure. Caution! Do not apply more pressure than necessary. The monitor will not inflate above the 300! 4.2 Read display 1 Read values of blood pressure and pulse from displays. 2 Note values in your personal blood pressure pass. 9

English 3 Press on/off button to turn off power. Note: power automatically switches off after 5 minutes. 5 emory 5.1 Recall previous values W X W emory: stored measurements displayed. X Average: average value of the last 3 measurements displayed. 1 Press on/off button to turn on power. Caution! Wait for zero and the heart symbol to continue! 10 2 Press memory button ( ). Note: display shows average value of last 3 blood pressures and heartbeats.

English 3 Press memory buttons ( / ) for latest and previous values. Press on/off button to turn off power. Note: display shows alternately date and time of measurement. Note: keep memory buttons ( / ) pushed to fast forward. 5.2 Erase memory 1 Press on/off button to turn on power. Caution! Wait for zero and the heart symbol to continue! AP 2 Press memory button ( ) and start button simultaneously to erase memory. Note: press memory button ( ) first because the start button will start inflation. Caution! All stored values will be erased! Press on/off button to turn off power. 11

English 6 Storage. 1 Slightly fold air tube and insert in cuff. Note: do not disconnect air tube. 2 Put cuff and main unit in storage case. Remove the batteries if you do not intend to use the ORON for 3 months or more. Store the ORON in the carton in a dry, closed place with a temperature between -20 C and 60 C. 7 Error: causes and rectifications Indication Error Cause Rectification Incorrect inflation ovement Repeat measurement. If necessary, hold start button to inflate manually Correct ovement, sound Follow instructions, repeat measurement Incorrect fastening cuff measurement not possible Operation start button for more than 3 seconds Cuff leaks air Fit new cuff Cuff pressure too high Follow instructions, repeat measurement 12

English 7 Error: causes and rectifications Indication Error Cause Rectification Abnormal memory function Consult your ORON retail outlet or distributor Low voltage Batteries weak/exhausted Fit four new identical 1.5V batteries type AA, follow instructions Display empty AC adapter disconnected Connect AC adapter correctly, follow instructions No data in memory Unplugged AC adapter Fit four new identical 1.5V without batteries batteries type AA Inexplicable values Wrong working method Follow instructions, repeat measurement 8 aintenance and spare parts Cleaning instruction Use a soft, dry cloth to wipe stains from the ORON. Use a soft, slightly moistened cloth and soap to clean main unit and cuff of the ORON. Caution! Do not use petrol, thinners or similar solvents! Caution! Do not wash the cuff! Do not carry out repairs of any kind yourself. If a defect occurs, consult your ORON retail outlet or distributor as mentioned on the packaging. Calibration It is recommended to have the ORON inspected every two years to ensure correct func tion and accuracy. Consult your ORON retail outlet or ORON distributor as mentioned on the packaging. Replace cuff Remove the air plug to re-use it with a new cuff. Replace batteries Remove the battery out of the battery compartment and insert four new identical 1.5V batteries type AA. Spare parts Due to high company quality standards, ORON considers the main unit as a non-serviceable part because of the need for proper calibration after replacement of high tech components. Attention! Disposal of batteries and the ORON should be carried out in accordance with the national regulations for the disposal of electronic products. 13

English 9 Technical data Product name odel Display easurement range Accuracy Inflation Deflation Pressure detection emory Power supply Battery life Operating temperature / Humidity Operating environment Storage temperature / Humidity Weight Outer dimensions Accessories Optional parts Note ORON Digital Automatic Blood Pressure onitor Digital LCD Pressure: 0-299 / Pulse: 40-180ute Pressure: ± 3 / Pulse: ± 5% of display reading Automatic inflation (Fuzzy control) Automatic air release by controlled air release valve Electrostatic capacity pressure sensor 90 easurements 4 x 1.5V batteries type AA / AC adapter (optional part) New batteries will last for approximately 300 measurements +10 C to +40 C / 30% to max. 85% relative humidity Free from excessive vibrations, shocks, magnetic fields, electrical noise, etc. -20 C to +60 C /10% to max. 95% relative humidity ain unit approximately 400 g, excluding batteries, cuff approximately 130 g Approximately 165 mm (W) x73 mm (H) x 110 mm (D), cuff approximately 150 mm (W) x 582 mm (L) arm circumference 22 cm to 42 cm Cuff model HE-CUFF-P, hard case, instruction manual, guarantee card, blood pressure pass AC adapter, extended tube Subject to technical modification without prior notice = Type B 0197 anufacturer EU-representative ORON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, uko, Kyoto, 617-0002 JAPAN ORON HEALTHCARE EUROPE B.V., Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS ade in China This device fulfils the provisions of the EC directive 93/42/EEC (edical Device Directive). This blood pressure monitor is designed according to the European standard EN1060, Non-invasive sphygmomanometers Part 1: General Requirements and Part 3: Supplementary requirements for electromechanical blood pressure measuring systems. This ORON product is produced under the strict quality system of ORON HEALTHCARE Co., Ltd., Japan. The Core component for ORON blood pressure monitors, which is the Pressure Sensor, is produced in Japan. 14

English 10 General information about blood pressure Blood circulation The blood circulation is responsible for supplying the body with oxygen. Blood pressure is the pressure exerted on the arteries. The systolic blood pressure value (higher pressure or top value) represents the blood pressure produced by contraction of the heart muscle. The diastolic blood pressure value (lower pressure or lower value) represents the blood pressure produced by relaxation of the heart muscle. Classification of blood pressure The World Health Organisation (WHO) and the Inter - national Society of Hypertension (ISH) developed the blood pressure classification. This classification is based on the blood pressure values measured while sitting on a chair in the outpatient department of a hospital. Health and blood pressure The incidence of hypertension increases with age. In addition, a lack of exercise, excess body fat and high levels of cholesterol (LDL), which sticks to the inside in blood vessels, reduces elasticity of these vessels. Hypertension accelerates arterial sclerosis which can lead to very serious conditions such as stroke and myocardial infarction. For these reasons it is very important to know whether the blood pressure is within a healthy range. Blood pressure fluctuates from minute to minute, throughout the day. Therefore it is essential to take regular measurements to help you identify an average blood pressure. Symptoms of high blood pressure High blood pressure can go unnoticed for a long time, since it does not cause noticeable symptoms. The following are all possible causes of abnormally high blood pressure: Overweight High cholesterol level Systolic blood pressure () 180 160 140 130 120 Normal systolic value Normal blood pressure Optimal blood pressure (target value) 80 oderate hypertension ild hypertension Severe hypertension 85 90 100 110 Diastolic blood pressure () According to the blood pressure classification by the WHO/ISH. 15

English Smoking Excessive alcohol consumption Stress and emotional upset Excessive consumption of salt Lack of physical exercise Genetic/hereditary predisposition Underlying illnesses, such as kidney disorders or endocrine disturbance Blood pressure measurement easuring your blood pressure daily enables you to recognize high blood pressure at an early stage and obtain medical treatment. The oscillometric method of measurement determines your blood pressure by measuring the pressure fluctuations caused by the pulse waves. Since your blood pressure fluctuates within a day (see graphic next page), you should always measure it at the same time each day to ensure that the measurements are genuinely comparable. At the doctor s surgery, nervousness and tension may cause your blood pressure to be higher than in familiar circumstances at home. This is known as White Coat Hypertension. Treatment of high blood pressure If your blood pressure reaches upper values of 140-160 and lower values of 90-95 in repeated measurements over several days, you should consult your doctor for detailed medical examination. You can assist the treatment prescribed by your doctor in the following ways: Loose weight and lower your cholesterol level by reducing the calories and fat in your diet. Cut down on animal fats and eat more fruit and vegetables. Reduce the consumption of alcohol. Reduce the intake of salt: the German League for Combating High Blood Pressure recommends six grams of salt per day (i.e. one teaspoon) on average. Stop smoking. Take regular exercise. onitor your blood pressure. 200 Upper curve: systolic blood pressure Lower curve: diastolic blood pressure 150 100 50 6 12 18 24 Time of day Example: fluctuation within a day (male, 35 years old) 16

anufacturer ORON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, uko, Kyoto, 617-0002 JAPAN EU-representative EC REP Production facility Produktionsstätte Productiefaciliteit Site de production Oficina de producción Stabilimento di produzione Subsidiary Niederlassung Dochteronderneming Succursale Empresa filial Consociata ORON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com ORON (DALIAN) CO., LTD. Dalian, CHINA ORON HEALTHCARE UK LTD. Opal Drive, Fox ilne, ilton Keynes, K15 0DG, U.K. ORON EDIZINTECHNIK HANDELSGESELLSCHAFT mbh John-Deere-Str. 81a, 68163 annheim, GERANY www.omron-medizintechnik.de ORON SANTÉ FRANCE SAS 14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, FRANCE Uniquement pour le marché français: ORON Service Après Vente Nº Vert 0 800 91 43 14 consommateurs@omron-sante.fr www.omron-sante.fr/contact ade in China Hergestellt in China Geproduceerd in China Fabriqué en Chine Fabricado en China Prodotto in Cina