WatMan WATER RO SYSTEMS FOR DESALINATION

Similar documents
SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems

Light Commercial Reverse Osmosis System. EE-1000 Manual

Reverse Osmosis System Installation Guide and Operation Manual.

This Page Intentionally Left Blank 2

This Page Intentionally Left Blank 2

erc-o 2 -tech Ò innovative gas systems Markwerbener Str Weißenfels Germany

This Page Intentionally Left Blank 2

CNG FILLING STATIONS

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

D C P L OXYGEN / NITROGEN PLANT

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

829S1 Series Flexflo Pilot

ScanFoam. Cleaning Equipment ApS. w w w. s c a n f o a m. c o m

ULTRA PURE SYSTEMS 625 GPD RODI INSTALLATION AND OPERATION MANUAL

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Technical Service Bulletin March 2015 TSB142.01

SyncroFlo Municipal University and Hydraulic Institute, Pump Systems Optimization

1020 Industrial Drive, Orlinda, TN fax

KEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Withstands Severe Treatment at Reverse Osmosis Facility

A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications

AN INNOVATIVE APPROACH TO OPTIMIZE REVERSE OSMOSIS MEMBRANE PERFORMANCE

DEEP WELL SUBMERSIBLE PUMPS. An ISO 9001 & Company

Liquid level regulating valves Types PMFL / PMFH and SV

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

CCT-7320/ROC-2313 Reverse Osmosis Controller

Prestige Water Equipment Ltd.

Single-pass and Double-pass Osmosis

PuROmaxtm. HP, LP, XL, And TS Operation Manual LP ,800 GPD 1.9 GPM LP ,000 GPD GPM LP ,.000 GPD 3.47 GPM

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

High Pressure Breathing Air Compressors

HYDRAULICS. H89.8D - Hydraulic Bench

ULTRA PURE SYSTEMS 400 GPD RODI INSTALLATION AND OPERATION MANUAL

1020 Industrial Drive, Orlinda, TN fax

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

TECHNICAL DATA. Q = C v P S

GasTrak Pro TM Delivery/Control Systems

Glass tube flowmeters Series 2000

Operation Guide SUPRA. Operation and Maintenance Manual. H2O Innovation

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

GROUTEC SCOTT VICKERS. Grouting Equipment

Pressure and Flow Control Valves DBGM, German and European Patents

Village Marine IMF 7,000-20,000. Part Number: Industrial Media Filter IMF 7,000-20,000. Installation, Operation & Maintenance

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters

KSB Delta Compact Type Series Booklet

INSTRUCTION MANUAL Ecosoft RO System MO6000GTE MO10000GTE

NGN Series nitrogen generator

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

GMD20..NL, GMD30..NL* GHV20..NL, GHV30..NL* GHV40..NL, GTKS20..NL* Series

REVERSE OSMOSIS INSTALLATION Watermark 4 Stage

BOSS PULISCI PROVA IMPIANTI MEDIA

DRAFT Standard Operating Procedure Ultrafiltration and Reverse Osmosis

Pressure reducing valves Index

Watermakers OWNERS MANUAL BEACH HOUSE SERIES (VERTICAL SYSTEM) 1000-BHL- 2 / 1300-BHL- 3 / 1800-BHL- 4 PAGE 2 INTRODUCTION 3 SPECIFICATIONS

GENO -Flushing Compressor Product Data Sheet F 02

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

STAUFF Accumulators Accessories

KRO AUGUST Prepared for: WashTec Australia 1, 33 Maddox Street Alexandria NSW 2015 Sydney, Australia

Y O U R W A Y IRRIGATION COMPONENTS. adritec.com

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

KSB Delta Compact Type Series Booklet

Technical Service Bulletin July 2014 TSB

Liquid Level Controls

Measurement of Low GAS & Liquid Flows

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

23.1 Functions, Basic Configuration, and Interfaces

TECHNICAL DATA. Q= Cv S

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

CompAir provide high quality and reliable Nitrogen solutions

Variable Area Flow Meters

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

GA24 Technical Datasheet

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Unique solutions for Oxygen and Nitrogen supply

Screw Compressors 11-22kW

the strength behind the products you trust

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

Materials: Rigid PVC body, PVC end plugs, PVC reinforcement cuff, Stainless steel cuff bands

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

LGSS Liquefied Gas & VSS Vapor (Gas) LGSS VSS LGSS. Features and Benefits

INSTALLATION INSTRUCTIONS

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

AirSep PSA Nitrogen Systems

Pressure regulator for water

Gas Pressure Regulator HON 280H - 309

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

TECHNICAL INFORMATION

SINGLE VALVE WITH LOW-FLOW BYPASS

SPIROVENT VACUUM DEGASSERS

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302

Autocalibration Systems For In Situ Oxygen Analyzers

Quality filter cartridges and customized housings.

Transcription:

WatMan WATER RO SYSTEMS FOR DESALINATION The WatMan reverse osmosis systems produce from 1 to 2000 m 3 per day of high quality water suitable for communities, marine environment, boiler feed and general industrial applications. The systems can operate on a range of feedwater qualities at recoveries of up to 85 percent, and will remove up to 99,9 % of dissolved inorganics, organics, colloidal and suspended particulates. The WatMan RO systems come with a number of options and can be tailored to suit a customer s specific requirements.

SPECIFIC FEATURES Powder-coated mild steel skid IP54 coated steel control panel Antiscalant dosing system or water softeners PLC by Omron, Siemens or Mitsubishi Stainless steel cartridge filter Operation panel Low pressure feed pump HP pump pressure switch Multi-stage high pressure pump or Piston pump Feed conductivity indicator Side-entry RO vessels Permeate conductivity indicator ABS or PVC low pressure piping Permeate flow indicator Stainless Steel high pressure piping Reject rotameter or flow indicator CIP/Flush tank Low noise reject control valve Air operated valves Feed temperature indication Sampling points Pressure gauges AVAILABLE OPTIONS Site tailored pre-treatment - Multi-media filtration for suspended solids removal - Activated carbon filtration or chemical dosing for chlorine removal - Micro or ultra filtration - Iron removal filtration - Chemical dosing - Polypropylene or coated filter housing for high chloride applications

- Antiscalant low level alarm - Variable Frequency Drive (VFD) for high pressure pump control - RO Module inlet/outlet pressure transmitters - Reject flow transmitter - Reject recycle with flow rotameter or constant flow controls - Remote monitoring facility - Stainless steel skid frame - Electrically controlled valves - ASME certified pressure vessels - 2-pass systems for high-purity applications - Energy recovery for low-energy applications - Fresh water remineralization or rehardening PLANT SPECIFICATIONS Low pressure pump Cartridge or Bag filter Cartridge/Bag filter elements Antiscalant dosing pump Antiscalant dosing tank High pressure pump STANDARD EQUIPMENT Centrifugal low pressure pump Housing in stainless steel Polypropylene (5 micron rating) Solenoid-operated dosing pump Polyethylene tank with level control Vertical or horizontal multistage centrifugal Piston pump Plunger pump Pressure vessels Membrane elements CIP/Flush tank PLC Controller Operator Interface Permeate flow Permeate conductivity Reject flow Pressure gauges Reject throttling valve Low pressure piping High pressure piping FRP or SS sideport with victaulic ports Spiral wound (high rejection, low pressure etc.) Polyethylene Omron, Siemens or Mitsubishi Operation panel, PLC Interface or PC with process visualization Rotameter or flow transmitter EC transmitter with temperature compensation Rotameter or flow transmitter Glycerine-filled 50/100mm diameter Stainless steel angle seat globe valve Constant flow controls ABS or PVC Stainless Steel (316 or High Grade)

TERMINATION POINTS Feed inlet 32 140 Flange ABS or PVC Media filter inlet/outlet 32 140 Flange ABS or PVC Permeate outlet/dump 32 100 Flange ABS or PVC Reject outlet 32 100 ABS or PVC Air supply ½ UTILITY REQUIREMENTS Power supply Air supply 230/380/400/440/460/ 690V 50/60 Hz 1/3 phase 600 kpa instrument air FEEDWATER REQUIREMENTS Feedwater Pressure Flooded Suction or 3-5 bar Feedwater temperature 2 40 0 C Total Dissolved Solids LP: up to 1,500 mg/l MP: up to 7,500 mg/l HP: up to 45,000 mg/l Silt Density Index Less than 5.0

SYSTEM PERFORMANCE and DIMENSIONS Nominal Product Max Max Power Max Max Pressure Dimension Flow * Recovery ** (bar) (kw) *** Weight Model (m 3 [mm] /day) (LP/MP/HP) (LP/MP/HP) (LP/MP/HP) (kg) HxWxD RO100 2 75/60/45 12/30/65 1.5/1.5/1.5 80 1650x750x650 RO200 5 75/60/45 12/30/65 1.5/2.2/3.0 110 1650x750x650 RO500 10 75/60/45 12/30/65 2.2/3.0/5.0 160 1650x750*650 RO1000 20 75/60/45 12/30/65 3.0/5.0/10 260 1850x1000x1000 RO2000 40 75/60/45 12/30/65 3.0/10/15 500 1850x1000x1000 RO3000 60 75/60/45 12/30/65 5.0/12/22 1050 1750x2600x1000 RO5000 100 75/60/45 12/30/65 7.5/15/30 1300 1750x2600x1000 RO7500 150 75/60/45 12/30/65 10/20/45 1750 1750x2600x1000 RO10000 200 75/60/45 12/30/65 15/30/60 2250 1900x3600x1000 RO15000 300 75/60/45 12/30/65 18.5/40/90 2650 1900x3600x1000 RO20000 400 75/60/45 12/30/65 22/45/75 3100 2100x4600x1250 RO25000 500 75/60/45 12/30/65 30/55/90 3400 2100x4600x1250 RO30000 600 75/60/45 12/30/65 30/75/110 3700 2100x5600x1400 RO 40000 800 75/60/45 12/30/65 37/90/160 4250 2100x5600x1400 RO50000 1000 75/60/45 12/30/65 37/110/200 5100 2300x6600x1400 RO60000 1200 75/60/45 12/30/65 45/132/250 6050 2300x6600x1400 RO70000 1500 75/60/45 12/30/65 45/145/315 6900 2300x6600x1400 NOTE: LP: Low Pressure; MP: Medium Pressure; HP: High Pressure Seawater Desalination *: Nominal product flow rates are based on feed temperatures of 10 0 C (LP/MP) or 25 0 C (HP) **: Recovery rates greater than informed are achievable. Operating conditions should be verified by WatMan. ***: Max. power is for your information only. Actual guarantee values are given case-by-case. We reserve the right to change the above data without notification of such changes being made. For more information, please, contact Oy WatMan Ab, Water Management, Yrittajantie 4, FI-09430 SAUKKOLA, FINLAND Tel +358-20-7417220; Telefax +358-19-371 011; info@watman.fi