SERVICE INSTRUCTIONS

Similar documents
KIV-SACS Safe automatic calibration system:

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Viva TPS. TS11/15 Total Stations Check and Adjust Procedure. October Summary

Relative Humidity Calibration Kit

These variables can be accessed by holding the UP button for 5 seconds.

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Kestrel 5700 Elite. App Quick Start Guide

Instruction Manual MediPrep 120

INSTRUCTION FOR FILLING OUT THE JUDGES SPREADSHEET

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

OPERATOR s MANUAL AHCON PCI 3000

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Determination of the physical properties of different types of milk claws and air leaks in the claw according to rotameter-milk bucket methods

ActiveYield. Operation and Adjustment

1. PERIODIC CHECKING OF APPROVED METERS. HINTS FOR THE SAMPLE TAKER AND FARMER

SS32L Dissolved O 2 Probe

Measurements. Metric System

Relative Humidity Calibration Kit

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

Automated Liquid Handling Station

OPERATORS MANUAL AHCON PCI 1000

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

Instruction Manual Dräger MSI P7 and MSI P7 plus

Dissolved Oxygen/Temp Waterproof Tester

Instruction Manual. BZ7002 Calibration Software BE

Armfield Distillation Column Operation Guidelines

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

BASIC LABORATORY TECHNIQUES (Revised )

Introduction. The Shearwater Petrel is an advanced technical diving computer for open and closed circuit divers.

2017 Census Reporting To access the SOI s Census Reporting web site go to:

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps

WATER CONTROL SYSTEM QUICK START

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

Manual Weighingblock VB2 series and Uniscale

Tennis...32 Stay above...34 Decimal...36 Bundesliga simulator...38 Shooter management...41 Installation...43 Registration...45 Where do I get the

BASIC LABORATORY TECHNIQUES (Revised )

Hydro-Control V User Guide

Safety Manual VEGAVIB series 60

955730_1 4/17/18. FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays

SOLUBILITY OF A SOLID IN WATER

ALGE DIVE! ALGE. ALGE-TIMING GmbH & Co

Instruction Manual. LKHSP Self-Priming Centrifugal Pump (Appendix) ESE02222-EN

The Ideal Gas Constant

EPSILON. User Manual. EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

American Standard. Selectronic Remote Control Operating Manual M965370

Dive Planet. Manual. Rev Basic User Interface. 2 How to organize your dives. 3 Statistics. 4 Location Service and Map View.

Survey Technical Support Notes October 2015

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

HOW TO SETUP ROUND ROBIN IN DARTS FOR WINDOWS

DQM Annual Hopper QA Checks

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

UsER manual for Watersens ph -REDOX

EZ-Boom 2010 Automated Application Control System Quick Reference Card INTRODUCTION

Experiment P18: Buoyant Force (Force Sensor)

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

Blackwave Dive Table Creator User Guide

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

Metatron 21. The proven specialist for professional milking management. GEA Farm Technologies The right choice. GEA Milking & Cooling WestfaliaSurge

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

Click on the menu icon in the left corner to open the menu. From the menu you can:

Device overview. 6 Breathing circuit connection. Note: When the remote control foot pedal is connected, the manual switch is disabled.

TQC Bresle Chloride test 2008

Technical Procedure for Instrument Calibration and Maintenance

BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

AXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)

Description. Measuring Device 3760XBI USP. Balancing

MS-500. User Manual. MS-500 (500g x 0.1g) Copyright 2010 Fast Weigh Scales All rights reserved. Rev. 2.0

Elcometer 138. Bresle Kit and Patches. Operating Instructions

EZ Boom 2010 System for the EZ Guide 500 Lightbar Triangle Ag Services Users Guide

Remote Control Bait Boat

VOLUMETRIC TECHNIQUES

- for the cow, the milk and the milker

K-STATE GRAIN QUALITY RESEARCH PROGRAM STANDARD OPERATING PROCEDURES

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

2011 Meter Technician Training School Springfield, MO

Water Testing Technologies: Stepping Into the 21 st Century Ivars Jaunakais

Objectives. Materials TI-73 CBL 2

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

Walk-O-Meter User Manual

Instruction Sheet. Calibration of Multiple 1720 and FT660 Turbidimeters

Info Counting chamber (haemacytometer)

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

EXPLOSIVE STORAGE CAPACITY CALCULATING TOOL USER MANUAL

Lesson 12 New Procedure PULMONARY FUNCTION I

SAUTER FK Version /2016 GB

Jackpot Rodeo - A Tutorial

Laboratory Mortar Mixer (Testing)

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

blue by Riiot OPERATING INSTRUCTIONS

Chromat Calibration Updated October 27th, 2017

THE UNIVENTOR 400 ANAESTHESIA UNIT

Trial # # of F.T. Made:

Standard Operating Procedure. Air Displacement Pipette Calibration

Quick Guide. SGX-CA500 Cycle Computer SGY-PM Series Power Meters

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Safety Manual VEGAVIB series 60

Transcription:

H4 60.069GB Installation- and periodical calibration Calibration and test of IDC To ensure that the values registered by the IDC milk meter are correct, the milk meter must be calibrated and tested after installation. To ensure the accuracy of this calibration, the plant must have run in a normal milking routine for at least one week before performing the calibration. IDC: No calibration of this unit. IDC, IDC-T: Only water calibration. IDC: Both water calibration and milk calibration. IDC for sheep and goats: carried out like IDC for cows except from a change in the water amounts that run through the IDC during calibration. Installation test Installation test can be performed week after the plant has started normal milking routine, at the earliest. The test is performed by the fitter in the following way. The milking system is washed immediately before the test. Wash must contain the following elements: Wash with base, which must have a start temperature of min. 75 o C and end temperature must exceed 4 o C. Wash with acid. If lime scale or other sediments are visible after wash perform an additional hot acid wash with a start temperature of min. 70 o C. The plant must be entirely clean and free of sediments before starting calibration!! Check that the IDC s are hanging horizontally within a tolerance of ± o and that the measuring cups are correctly fitted and not twisted in relation to the fitting tap. When calibrating one or more milk meters it is important that the milk meters that should not be calibrated are not serviced. The calibration fluid is mixed according to the following table: L mixed fluid 0 liter 5 liter 0 liter Household salt (NaCl) 0 gram 45 gram 60 gram Calibration fluid (87) 5 ml 8 ml ml Washer rinse (90) ml 0 ml 7 ml Mixing procedure:. Dissolve NaCl in L of hot water with a temperature above 50 o C.. Add calibration fluid and washer rinse.. Stir the mixture until salt is dissolved. 4. Add cold water to reach the desired volume and stir again. When using the fluid for calibration it must have a temperature between 5 and 0 o C. 7000065-00 9.0.05

H4 60.070GB Mixture must be recycled for calibration of same measurements. Same mixture can also be used for calibration of several meters. The mixture can be used for an entire day, after which a new mixture must be made. The scales in use must have an accuracy of +/- 0.0 kg Flowmeter (900 7.000) equipped with.85 mm nozzle (89) that gives L/min at 8 kpa at high flow and a.5 mm nozzle (88) that gives L/min at 8 kpa at low flow. For sheep and goats, the nozzles are respectively 400 g/min: 7 00. and 000 g/min: 88 A B Airflow through the flow meter must be 6-8 l/min. H=400-450 mm Calibration setup C Remove the milk hose from the milking cluster and replace it with the flow meter (A). It is important that the hose is guided from flow meter to IDC as usual as displayed on page H4 60.074GB. Now the water is lead to a milking bucket (C) from the bottom of the IDC instead of through the milk line. It is important that the hose has a drop from the IDC to the milk bucket for the water to primarily run through and not be pushed through by air. A bucket (B) with water from which the flow meter sucks water is set where the cow would normally stand. If necessary the milking bucket can be equipped with Bottom piece, closed (0 46.0) so that mounting of a pulsator is not needed. Before choosing the calibration setting on the power supply it is important that all IDCs are in milking mode and not milking. x Choose the calibration menu from the configuration menu. Access to the configuration menu is described elsewhere in this service manual. After choosing calibration menu an overview is displayed of the state of all IDCs. Power supply must be in this menu item as long as calibration is in process. Furthermore, all IDCs have changed displays image to calibration image and the display reads 4.00. System is now ready for calibration of individual IDCs. This process is described on following pages. When calibration of individual IDCs is done press leave menu button. All IDCs now leave calibration mode. Screen image on power supply is updated with the new state of the IDCs. Press Leave menu again and the IDCs return to the calibration menu. If the entire calibration is not done, it is possible to leave the calibration menu after calibrating a number of IDCs and begin normal milking. Remaining IDCs can be calibrated later by returning the entire system to calibration menu. 700000978-00 0.0.05

H4 60.07GB The rest of the calibration routine takes place on the IDCs that have changed to the screen image in step item. At the same time the diode flashes between green and red, when water is not sucked through the IDCs. Water calibration step - 4kg/min (Sheep/goats,4 kg/min) Cows: Sheep / goats: The flow meter is set to suck through the large and the small nozzle at the same time (the flow meter will now suck 4 L/min (cows) or,4 L/min (sheep/goats)). Press start and the IDC will suck up water. After about 5 seconds start is pressed again so the IDC stops. This is done to change the amount of water in the IDC, and change the hoses to a high flow. Cows: Sheep / goats: Empty the milk bucket on the floor and ensure that there is enough water in the bucket standing in the cows place to go through this item. Press the start button and the IDCs will suck up water from the bucket. The IDC stops automatically, when desired amount has been sucked and screen image changes to the one displayed in item. Weigh the amount of water (kg) in the milk bucket and enter the weight into the IDC. It is important that it is the water that has been passed through the IDC that is weighed and NOT the weight difference of the bucket the water has been sucked from. Press when the desired amount has been entered in the IDC. By pressing X the marker returns to start. After successful entry the display image changes to the one in item 4. 4 One of the following screen images appear. Top one appears when this part of the calibration is successful and all items on the screen have been marked by a percentage. As displayed a appears above the center button. Press this to continue to the next calibration step. IDC now shifts to step item. The bottom screen image appears if this part of the calibration is inaccurate and must be repeated or enough measurements have not been made. As displayed there is no above the center button. Furthermore there is a on top of the screen. It is only possible to leave the menu, which brings the IDC back to item. 7000005-00.0.05

H4 60.07GB Water calibration step - kg/min (Sheep/goats 0,4 kg/min) Cows: Sheep / goats: Set flow meter to only suck through the small nozzle (flow meter will now suck L/min (cows) or 0,4 L/min (sheep/goats)). Press Start and the IDC start sucking water. Press Start again after app. 5 seconds to stop IDC. This is done to alter the amount of water in the IDC and hoses to low flow. Cows: Sheep / goats: Empty the milking bucket on the floor and ensure that there is enough water in the bucket on the cow s place to complete this item. Press Start on the IDC and it starts sucking water from the bucket. IDC stops automatically when desired amount has been sucked and screen image changes to the one displayed under item. Weigh the amount of water (kg) in the milk bucket and enter the weight into the IDC. It is important that it is the water that has passed through the IDC that is weighed and NOT the weight difference of the bucket that water is sucked from. Press when the desired amount has been entered in the IDC. By pressing X the marker returns to start. After successful entry the display image changes to the one in item 4. 4 One of the following screen images appear. Top one appears when this part of the calibration is successful and all items on the screen have been marked by a percentage. As displayed a appears above the center button. Press this to continue to the next calibration step. IDC now shifts to step item. The bottom screen image appears if this part of the calibration is inaccurate and must be repeated or enough measurements have not been made. As displayed there is no above the center button. Furthermore there is a on top of the screen. It is only possible to leave the menu, which brings the IDC back to item. 70000054-00.0.05

H4 60.07GB Water calibration step completion IDC now displays a screen image holding the different calibration values. Furthermore, either a is displayed, if IDC is fully calibrated, or if routine must be repeated. Go back to step item if routine must be repeated and repeat calibration. Routine must be repeated until appears after which calibration is complete. Write down calibration values when appears not before. If there are interruptions that interfere with completion of the calibration, calibration must be started over. When pressing Leave menu the user is returned to screen image in step item and a new calibration can be started. This applies whether calibration is successful or must be repeated. Exit from calibration mode can be done from power supply as described on page H4 60.070GB. 00006099 09..6

H4 60.074GB Milk calibration control IDC After completed water calibration of IDCs they must be controlled and adjusted during milking. A This is done by control weighing a series of milkings, calculate their calibration value and then enter this value in the IDC. This must be done for all IDCs individually. H=400-450 mm Calibration setup The milk is now lead from the bottom of the IDC to a milking bucket (A) instead of in milk hose. It is important that the hose has a drop from milk line to IDC for milk to primarily runs and is not pushed through by air. Hold in for sec. Code: 075 Read existing calibration value here Value is altered to new calibration value, which is calculated on the following pages Before the first check is carried out, it is important to ensure that there is milk in the IDC and cluster; otherwise an error measuring may occur which can influence the final calibration result negatively. Milk calibration manual / spreadsheet Milk calibration can be done by using the attached table including instructions or by downloading the calibration spreadsheet from SAC s internal network, which is developed especially for this purpose. Instructions on this procedure are attached to this manual. Measuring cup replacement (49) or IDC print (76) If a measuring cup or IDC print is replaced both a water and milk calibration must b e performed on the relevant IDC to uphold ICAR-approval. 7000088-00 5.09.09

H4 60.075GB Procedure for milk check The columns are filled according to following formula in the table on the next page: Remember to fill in signs. Column : The amount visible in the IDC display when milking is completed. Column : The amount weighed in the bucket. Column : Column column. Column 4: Column * 00. Column 5: Column 4/Column. Field 6: The largest difference between numbers in column 5 (largest number - smallest number). Check: If the number in field 6 is smaller than -5 or larger than 5, milk calibration must be started over with new measurements in a new table. Otherwise skip to field 7. Field 7: Sum of all numbers in column. Sum of all numbers in column. Field 9: Field 8/Field 7. Field 0: Current calibration factor in IDC * Field 9. Field 0: New calibration factor to be entered in IDC, instead of one already there. Calibration completed. Following is an example of a completed table. Calculation is based on IDC with an existing calibration value of 980. If the meter is not able to calibrate within ±5 in field 6 after several attempts, the measuring housing is changed and entire calibration procedure must be started over with water calibrating the IDC. In order to use the milking for calibration, more than 4.5 kg of milk in one milking is needed. Milking No Column Column Column Column 4 Column 5,4, 0, 0,79,,5-0, -0 -, 5,8 6-0, -0 -,5 Field 7: 40,40 Field 6:,04 40,70 Field 9:,0 Field 0: 987 000060 6.0.5

H4 60.086GB Table for calculation of control milkings - Performed on: Meter No Milking No Column Column Column Column 4 Column 5 Field 9: Field 0: Meter No Milking No Column Column Column Column 4 Column 5 Field 9: Field 0: Meter No Milking No Column Column Column Column 4 Column 5 Field 9: Field 0: Meter No Milking No Column Column Column Column 4 Column 5 Field 9: Field 0: Meter No Milking No Column Column Column Column 4 Column 5 Field 9: Field 0: Meter No Milking No Column Column Column Column 4 Column 5 Field 9: Field 0: 00006079 7 09..6

H4 60.09GB Milk calibration procedure for IDC using spreadsheet As replacement for the manual schedule the milk calibration can now be done by using the spreadsheet below, which can be found on SAC s internal network through the following link: http://intranet.sac.dk/getfile.php?objectid=789 Or through this path: Technical Dept. -> Fitter tools -> IDC The spreadsheet is filled in as described below: Enter farmers name and address here Choose language from the dropdown menu Read individual measurement result here Fields to be filled in by user Choose Language English Fields the user must check/use Farmer name and address Meter number Measurement Measurement Measurement Present calibration factor New calibration factor Page IDC Weight Deviation % 0,00 Too little milk for measurement. Redo measurement 0,00 Too little milk for measurement. Redo measurement 0,00 Too little milk for measurement. Redo measurement 0 0 0,00 One or more of the measurements is not OK 000 Factor written on the IDC during measurements --- Factor to enter in the IDC Write number for the meter being calibrated here The overall result of all measurements can be read here, but not until all measurements are finished Enter the milk amount read on the scale here Enter the milk amount read on the IDC display here Write the calibration factor on the IDC during measurements here. This is 000 on new meters This is the calibration value that must be entered in the IDC. This value does not appear until measurements are approved, until then the value is --- It is important that all measurements are written in their own area of the spreadsheet as all measurements must be sent to one of the offices below to achieve ICAR approval. After finished calibration send the calibration sheet as described below: Send to: The Local Milkcontrol Authorities (applies to all countries except Denmark) Send to: S.A. Christensen & Co (applies to Denmark) Ndr. Havnevej DK 6000 Kolding Att.: Service Department or Email: milkcontrol@sac.dk (applies to Denmark) 00006845 8 0.07.05

H4 60.09GB Annual control to uphold ICAR approval To uphold ICAR approval on the milk meter it must be controlled annually. This is done by completing a milk sample as described in this manual in the paragraph Calibration with milk IDC (page H4 60.074GB). Only measurement is necessary. If the total milk amount in the bucket is below 8 kg the measurement is invalid and a new must be made. The measurement must be carried out when the IDC operates in normal milking with normal removal procedure. During the annual check, the IDC must not operate in forced milking as this may cause a misleading result. If the total milk amount in the bucket is between 8 and 0 kg the IDC display must show the same amount +/-0.5 kg for the measurement to be valid. Example: Scale displays 8.5 kg and IDC displays 8.5 kg this measurement is valid, as 8.5 kg is within the interval of 8.00 and 9.00 kg which is allowed. If the total milk amount in the bucket is more than 0 kg the IDC display must show the same amount +/- 5% for the measurement to be valid. Example: Scale displays 5.8 kg and IDC displays 6.0 kg this measurement is approved as it is within the interval of +/- 5 %, which is 5.8x0.95 = 5.0 kg and 5.8x.05 = 6.59 kg If the IDC does not comply with the requirements for ICAR approval a new milk calibration must be done as described on page H4 60.074GB in this manual. For this calibration measurement used for validation can be entered as measurement number. After milk calibration the IDC is approved for another year s operation. In the spreadsheet edition it is only the two cells in the circle that must be filled in, as the rest are automatically calculated. In the paper version all fields must be calculated and filled in manually. Weight of milk in bucket in Kg Kg in IDC display Meter No. Weight [kg] Lower limit Upper limit IDC [kg] OK? If "weight" is above 0 kg: Weight x 0.95 If "weight" is under 0 kg: Weight 0.5 kg If "weight" is above 0 kg: Weight x.05 If "weight" is under 0 kg : Weight + 0.5 kg OK: If IDC value is greater than Lower limit and less than Upper limit The electronic version can be downloaded through this path: Technical Dept. -> Fitter tools -> IDC The direct link is: http://intranet.sac.dk/getfile.php?objectid=7890 7000057-00 9.0.4

H4 60.094GB Name: Address: Spreadsheet for calculating control milkings - Date: Meter No. Weight [kg] Low interval High interval IDC [kg] OK? After finished calibration send the calibration sheet as described below: Send to: The Local Milkcontrol Authorities (applies to all countries except Denmark) Send to: S.A. Christensen & Co (applies to Denmark) Ndr. Havnevej DK 6000 Kolding Att.: Service Department or Email: milkcontrol@sac.dk (applies to Denmark) 00006848 0 0.07.05