Lightweight II S.E. Improved Design & Acoustics. Stethoscope

Similar documents
3M Littmann Classic II S.E. Stethoscope

Master Classic II Stethoscope

the typical anatomy of the ear canal. The eartips should point in a forward direction as you insert them into your ear canals.

3M Littmann Master Cardiology Stethoscope

Classic II Pediatric Stethoscope Classic II Infant Stethoscope

STANDARD OPERATING PROCEDURE

3M TM Littmann Stethoscopes. A Trusted Leader in. Auscultation. Distributed by

600 / 600FC OWNER'S MANUAL

Mirage Vista Nasal Mask

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

602 STRINGING MACHINE OWNER'S MANUAL

OLYMPIC ARMS, INC. MPR SUPPLEMENTAL OWNER S MANUAL

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

RADAR. User Manual EASYCLIK MODEL Vascular. Compression. Device.

Aneroid Sphygmomanometer. Use, Care, & Maintenance

Hydraulic Punch Drivers

Item Name: 30CM GIRLS STAR THE UNICORN BIKE

AR STYLE FIREARMS OWNER'S MANUAL: OPERATION, HANDLING, DISASSEMBLY / REASSEMBLY & SAFETY INSTRUCTIONS

Item N o.: Item N am e:southern Star 40cm Girls Cherry Bike

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

200 STRINGING MACHINE

IMPORTANT: RECEIVING INSTRUCTIONS:

Product Information News September 26, 2003

RayPette Plus Autoclavable Pipette. User Manual

Hydraulic Punch Drivers

User Guide. Tripod. flowtech 75 / 100 Tripod. Part No. S S

MECH-TECH SYSTEMS CCU MODEL FOR GLOCK PISTOLS

trigger magazine release

6 digital caliper with case

Item N o.: Item N am e:40cm GIRLS VIOLET BIKE

WELLS JOHNSON HIGH VOLUME CANISTERS

Have questions? Chat with us live at raleighusa.com or call us at , 8am 5pm PST

Owner s Manual. Model H4685

The pipettes cover a volume range from 0.1µl to 10ml.

CHAPTER 2 MAINTENANCE

Manuale d istruzioni User s Guide Manuel d utilisation Manual de instrucciones Manual de instruções Οδηγίες χρήσης INSTINCT

English. ivolve Full Face Mask. User Manual

Sterile Visual Flow Indicator

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

Air-Mate High Efficiency Powered Air Purifying Respirator (PAPR) Staff Training Module

IMPORTANT SUPPLEMENTARY INSTRUCTIONS FOR Model1886 TAKEDOWN LEVER ACTION RIFLE

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

SASK-A-POLE OWNERS AND USERS MANUAL

FX IMPACT OWNER S MANUAL

Instruction Manual Manual No A. Doppler Rocket. Model No. WA-9826

Linkam Scientific Instruments USER GUIDE DSC600. Temperature Controlled Stage

SSS SWEEPERS MODELS MS-31 & MS-39

GM-121: Container End Lock Anchor Wand Page 1 WINSAFE CORP. GM 121 CONTAINER END LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE

SUPER PRO TM SERIES DUMMY LAUNCHER

Thank you for purchasing your new Empire Reloader B Sound-Activated 3-Speed Paintball Hopper!

COUNTRYMAN E6 DIRECTIONAL EARSET MICROPHONE

X-6 STRINGING MACHINE OWNER'S MANUAL. Issue 1 - May Copyright 2004 GAMMA Sports - All Rights Reserved

Mini Mr.Bulletfeeder by Double-Alpha

English USER GUIDE User guide

FAIR-COURT OFFICIAL BASKETBALL EQUIPMENT TESTING SYSTEM

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

SPUD OWNER S MANUAL ALWAYS WEAR A COAST GUARD APPROVED FLOTATION DEVICE WHEN OPERATING THE SPUD KAYAK.

Pipettor. User Manual

Grow to Pro Basketball

14500 Coy Drive, Grass Lake, Michigan Isolation Glove Box Instruction Manual

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

Have questions? Chat with us live at raleighusa.com or call us at , 8am 5pm PST

Road Bike Maintenance Clinic

USER MANUAL Tisas Pistols

COMPACT METAL bender 99826

Specimen Collection. Lead Screen Filter Paper Testing Dried Blood Spots (DBS) Laboratory Services February 2017

PISTOL CALIBER AR STYLE FIREARMS

Parts List. 7. Handlebars 8. Grips 9. Handlebar Stem 10. Front Brake 11. Front Wheel 12. Crank 13. Chain

TIPPMANN 98 CUSTOM. Owner s Manual CO2 POWERED PAINTBALL GUN

Item N o.: Item N am e:40cm Boys Rival Bike

Module IV Administration of Medications and Treatments Handouts

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

Have questions? Chat with us live at raleighusa.com or call us at , 8am 5pm PST

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

Paradise Pump Series Operator s Manual

Ultrasound Guided Thoracentesis Simulator Strap-on Type

Rev. B. Operating Instructions

G7S Hand Pump Owner s Manual

Ultrasound Guided Thoracentesis Simulator Strap-on Type

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

STRINGING MACHINE OWNER'S MANUAL. Issue 5 - November 2012

FAIR-COURT OFFICIAL BASKETBALL EQUIPMENT TESTING SYSTEM

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

slide takedown lever magazine release

Flat Fold Highchair INSTRUCTION MANUAL. Designed and manufactured to BS EN 14988: 2012 IMPORTANT:

DIRECT DRIVE DIXIE DOUBLE SEAMER Model 25D

Safety and operating instructions

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

ORRA SPINNING REEL INSTRUCTION MANUAL (DRAFT)

BEAM CLAY Soft Touch Bases A Series Premium Bases

500SE SECOND STAGE SERVICE PROCEDURE

WINSAFE CORP. OPERATING AND MAINTENANCE INSTRUCTIONS GM184 TOP ACCESS END LOCK ANCHOR WAND

Any tool, at the ready. 3M DBI-SALA Fall Protection for Tools Pocket Reference Guide

Swift LT NASAL PILLOWS SYSTEM. User Guide English

Helios Separable Tandem Manual

Transcription:

mproved Design & coustics ightweight S.E. Stethoscope nnovative chestpiece design Reliable and clear acoustics ightweight, durable design unable diaphragm for monitoring low and high frequencies Single lumen tube Convenient shape for blood pressure applications

English 3 ittmann ightweight S.E. Stethoscope Product Description: he ittmann ightweight S.E. is designed with a new ovoid shaped chestpiece and offset bell that allows easy access to auscultation areas difficult to probe with circular chestpieces. he new design also utilizes 3's tunable style diaphragm, non-chill rim and diaphragm, patented 3 ittmann Soft- Sealing Eartips and a comfortably angled, anatomically correct headset and comes in a variety of colors to meet individual preferences. ost of all, know that your ittmann ightweight S.E. stethoscope carries the ittmann brand name, the name known worldwide for unsurpassed quality. s a trusted leader in auscultation technology, the ittmann brand of stethoscopes is your assurance of acoustical superiority, innovative design and exceptional performance. 1

ntended se: his product is intended for limited physical assessment and other general purpose uses such as blood pressure assessment. t can be used for auscultation of heart, lung and other body sounds. his product is not designed, sold or intended for use except as indicated. Precautions: void extreme heat, cold, solvents, and oils. he entire stethoscope can be wiped clean with alcohol or soapy water. Eartips can be removed from the ear tubes for thorough cleaning. OE: Do not immerse your stethoscope in any liquid or subject it to steam sterilization. f disinfection is required, the stethoscope may be wiped with a 70% isopropyl alcohol solution. Explanation of Symbols:! ttention, see instructions for use. his product and package do not contain natural rubber latex. nstructions for se: Chestpiece: On ittmann stethoscopes with traditional combination chestpiece, you select either the diaphragm or open bell side by holding the chestpiece stem in one hand and rotating the chestpiece with the other hand until a click is felt. Changing Frequencies sing the unable Diaphragm: our ittmann ightweight S.E. Stethoscope is equipped with a 3 tunable style diaphragm that enables you to listen to both low and high frequency sounds without turning over the chestpiece. ow frequencies: o listen to low frequency sounds, (traditional bell mode) you can use either the open bell or tunable diaphragm using very light skin contact. High frequencies: o listen to higher frequency sounds, using the tunable diaphragm, press firmly on the chestpiece. o listen to low and high frequency sounds without removing and turning over the chestpiece, simply alternate between light and firm pressure on the tunable diaphragm. Eartip Replacement: For maximum acoustic performance, comfortable patented 3 ittmann Soft-sealing Eartips are provided with your stethoscope. his 2

stethoscope utilizes a unique design for attaching the eartip to the eartube. he eartips are pushed on to the end of the eartube and snapped firmly into place. o remove, pull firmly on the eartip. Headset djustment: our ittmann stethoscope is designed to provide a comfortable, acoustically sealed ear fit. otice that the ear tubes are set to accommodate Correct the typical anatomy of the ear canal. he eartips should point in a forward direction as you insert them into your ear canals. ncorrect o reduce spring tension in the headset, hold each ear tube at the bend near the eartip and gradually pull apart until fully extended. o increase spring tension, grasp the headset with one hand where the ear tubes enter the plastic tubing and squeeze until the plastic tubing on one ear tube touches the other. Repeat as necessary. 3 Removing the Diaphragm and Cleaning the Chestpiece: With the diaphragm side up, push the rim at one point with both thumbs and roll the rim off the edge of the chestpiece. Remove the diaphragm from the rim and clean parts in soapy water or wipe with alcohol. Wipe chestpiece surfaces with alcohol or soapy water. Dry all parts and surfaces thoroughly before reassembly. ssembly and Replacement of the Diaphragm: sing your fingertip, apply a small amount of talcum powder to the inside surface of the flexible edge of the diaphragm then align the rim and diaphragm as a unit. his will facilitate assembly and maintain smooth and quiet low/high frequency alternation. Snap the diaphragm with your fingers to remove excess talcum powder. nsert the flexible edge of the diaphragm into the groove of the rim. his is best accomplished by starting with the rim positioned above the legible side of the diaphragm. Visually

examine the ring to ensure that the flexible edge is smoothly engaged inside the rim. Refer to illustration for correct assembly of the non-chill rim and diaphragm. f necessary, flex the assembly by pinching the outer rim edge between the thumb and fingers. o attach the rim/diaphragm assembly to the chestpiece, engage the groove of the rim (with the diaphragm attached) around the chestpiece at one point and hold it in place with your thumbs. Slowly roll the rim around and over the chestpiece edge using both thumbs, moving in opposite directions around the chestpiece. Visually inspect the edge where the diaphragm engages the rim for uniform containment. inor adjustments may be made by slightly pulling and rolling the rim away from the diaphragm, allowing the diaphragm to slip into position. ittmann Stethoscope Service and Warranty Program: our ittmann stethoscope comes with the finest service and warranty policy in the industry. he ittmann ightweight Stethoscope is warranted against any defects in material and workmanship for a period of two (2) years. f a material or manufacturing defect is discovered during the warranty period, repairs will be made without charge upon the return of the instrument to 3, except in cases of obvious abuse or accidental damage. For maintenance or repair services, write a short note explaining the repair or service you require, include your name, address and phone number and send your stethoscope directly to: 3 Health Care Service Center Bldg. 502, Suite 200 3350 Granada ve. orth Oakdale, 55128 1-800-292-6298 CD: 3 Health Care Service Center 3 Canada nc. 80 Enterprise Drive South ondon, Ontario Canada 61C2 1-800-563-2921 Outside of the.s. and Canada please contact your local 3 subsidiary for maintenance and repair information. 4

ade in S by 3 Health Care, St. Paul, 55144-1000 (.S..) 1-800-228-3957 Fax 651-736-2803 Visit our web site: http://www.3.com/ittmann ttention, see instructions for use. 3 is a trademark of 3. ittmann is a registered trademark of 3. 38-9018-0777-6 3 Health Care D-41453 euss, Germany