Vacuum Insulated vertical cryogenic CO 2 & N 2 O Tanks

Similar documents
CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Inert Air (N2) Systems Manual

Liquid Gas Cylinder (LGC)

CAPITAL CONTROLS SERIES NXT3000

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Vacuum Jacketed Piping Solutions

APPS-160 Gen 2 User Manual

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Cool - Headed Solutions

Cryogenic Equipment. Accessories. Directors. Director Series Storage Vessels Specifications

Installation restrictions for length of sections should also be noted.

Installation Operation Maintenance

Chlorine Supply Containers And Piping

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

Trifecta High-Pressure Systems

CRYOGENIC PRESSURE REGULATOR

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

PRODUCT GUIDE Spring 2015

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

Best Practices for Installation of Gaseous Sample Pumps

The CWE / HWE-R Series: Overview. Frame and cabinet covering

SRI Jigger Tubes System

TECHNICAL BULLETIN CRYOGENIC APPLICATION SERVICES. website:

OPERATING INSTRUCTIONS

OPERATION MANUAL NTF-15

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Air Eliminators and Combination Air Eliminators Strainers

University of Minnesota Nano Center Standard Operating Procedure

CRYOGENICS & LNG Application Guide

Operating Instructions

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Self-operated Pressure Regulators for special applications

PROCESS GAS SAMPLING SYSTEMS

CHE Well Testing Package/Service:

MEDICAL EQUIPMENT CATALOG

Bulk Storage Systems. Equipment for Cryogenic Service. Bulk Storage Product Catalog

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

OPERATION MANUAL NTF-60 Plus

WORCESTER GREENSTORE. Indirect Unvented Cylinder with Solar Coil FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY GB/IE

GAS SUPPLY DESIGN GUIDE

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

v. Size shall be specified on drawings.

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

NGP-250/500 Nitrogen Generator Quick Start Guide

Linde Cryogenics. Helium Recovery Systems.

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Baffles and Traps Cryotrap

CRYOGENIC SERIES Regulators, Pressure Gauges, Shut-off Valves, Relief Valves Technology for a Better Future

NGN Series nitrogen generator

First Stage Regulators

553 Series.

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

2-step solenoid valve Type ICLX

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

LIQUID CYLINDER OPERATING MANUAL

TEST BENCH FOR SAFETY VALVES

MATHESON s LaserPro Gases and Gas Delivery Equipment

PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS INSTALLATION MANUAL CONTROL VALVES

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

ECS Protector Nitrogen Inerting Vent (PAV-WN)

BLADDER TANK PROPORTIONING SYSTEM PRE-PIPED

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

DECLARATION OF INCORPORATION

OPERATING INSTRUCTIONS AND PARTS LIST AUTOMATIC FILLING MACHINE DE-401-GB-AUTO

Vertical Bladder Tanks

Dual Solenoid Gas Valve Installation

GM Series Dual-Block Multi-Function Gas Control Valves

Thermocirc Installation and Maintenance Instructions

Safety Aspects and Design of the Vent Isolation Chamber. Prepared: W.M. Snow Checked: H. Nann Approved: W. M. Snow

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660

1305 Series Pressure Reducing Regulators

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Types ACE95 and ACE95Sr Tank Blanketing Valves

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

Cryogenic Storage of Ammonia

Vaporizer Piping Liquid Chlorine Manifolds

Installing a Probe. Typical Installation

Series Environmental Chambers

HORIZONTAL BLADDER TANK

A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications

FOAM TANK (1/2) DATA SHEET

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

MAINLINE MLA14 AIR CONDITIONERS

Ensuring cryogenic supply capabilities. Any application - Any time

Sample C ylinde rs, Acce ssorie s, and O utage Tube s

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

BUBBLER CONTROL SYSTEM

TECHNICAL MANUAL Liquid Tube Trailer Model: HP

Highest Quality. Gas Chlorination Systems

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

Horizontal Bladder Tanks

Transcription:

Vacuum Insulated vertical cryogenic CO 2 & N 2 O Tanks CRYOLOR introduces the latest generation vacuum isolated cryogenic tank, the RCIA Céline 3, for liquid CO 2 and N 2O service, with inner vessel in stainless steel. Available in a wide range of sizes with a Maximum Allowable Working Pressure of 22 bar ( 320 psig), RCIA Céline 3 is designed in accordance with ASME / U Stamp. Moreover, the support legs used in the RCIA Céline 3 range are calculated to resist high winds and earthquakes (Eurocode 1 and 8 and UBC zone 3 & IBC). The widest range of standard options: introduced by CRYOLOR, our innovative modular design using prefabricated piping modules, allows the basic model to be customized to satisfy virtually all possible technical requirements. A maximum use of Stainless steel: Only Céline 3 uses as much stainless in its construction to guarantee the lowest life cycle costs - valves, interconnecting piping and all welded connections are stainless. Components selected for their operational reliability - safety system with dual relief valves, stainless valves. Reduced overall operational costs - optimized pipework layout with fewer connections minimize potential leaks and facilitate operation & servicing, filling assembly isolation valves as standard, proven painting techniques guarantee years of care-free operation. H HT D G A B C This indicative technical data sheet is not a contractual document. SC0000 71_0_22B_CELINE_RCIA_ASME_CAP

Vacuum Insulated vertical cryogenic CO 2 & N 2 O Tanks RCIA6 RCIA11 RCIA14 RCIA21 RCIA27 Type (6MT) (11MT) (15MT) (23MT) (27MT) Gross capacity (liters / USG) * 6 150 1 625 10 540 2 784 14 910 3 939 23 660 6 250 28 040 7 407 Net capacity (liters / USG) * 5 658 1 495 9 697 2 562 13 717 3 624 21 767 5 750 25 797 6 815 Empty weight (kg / lbs) 4 570 10 075 6 190 13 647 8 310 18 320 11 240 24 780 13 120 28 925 Weight full Carbon dioxide (kg / lbs) - CO 2 10 528 22 511 16 401 36 158 22 754 50 164 34 161 75 311 40 284 88 811 Diameter (mm / feet) 2 200 7.2 2 200 7.2 2 200 7.2 2 200 7.2 2 200 7.2 Daily evaporation rate CO 2 (%) 0,086 0,086 0,080 0,080 0,075 0,075 0,070 0,070 0,060 0,060 HT height (mm / feet) 4 200 13.8 5 200 17.1 7 660 25.1 10 235 33.6 11 740 38.5 H (mm / feet) 520 1.7 520 1.7 520 1.7 520 1.7 520 1.7 G (mm / feet) 1 055 3.5 1 055 3.5 1 055 3.5 980 3.2 980 3.2 A (mm / feet) 2 250 7.4 2 250 7.4 2 250 7.4 2 300 7.5 2 300 7.5 B (mm / feet) 2 450 8.0 2 450 8.0 2 450 8.0 2 500 8.2 2 500 8.2 C (mm / feet) 1 245 4.1 1 245 4.1 1 245 4.1 1 245 4.1 1 245 4.1 * ± 4% Type RCIA33 (34MT) RCIA41 (40MT) RCIA53 (55MT) RCIA63 (62MT) Gross capacity (liters / USG) * 34 340 9 071 41 300 10 910 56 270 14 865 63 750 16 841 Net capacity (liters / USG) * 31 593 8 346 37 996 10 037 51 768 13 676 58 650 15 494 Empty weight (kg / lbs) 15 546 34 273 18 275 40 289 23 470 51 742 25 990 57 298 Weight full Carbon dioxide (kg / lbs) - CO 2 48 814 107 616 58 285 128 496 77 982 171 920 87 748 193 452 Diameter (mm / feet) 2 840 9,3 2 840 9,3 2 840 9,3 2 840 9,3 Daily evaporation rate CO 2 (%) 0,054 0.054 0.053 0.053 0,040 0,040 0,030 0,030 HT height (mm / feet) 8 850 29.04 10 510 34,5 13 510 50,9 15 025 49,3 H (mm / feet) 650 2,2 650 2,2 650 2,2 3 660 12 G (mm / feet) 1 100 3,6 1 100 3,6 1 100 3,6 1 100 3,6 A (mm / feet) 2 950 9,7 2 950 9,7 2 999 9,8 2 999 9,8 B (mm / feet) 3 300 10,8 3 300 10,8 3 350 11 3 350 11 C (mm / feet) 1 530 5 1 530 5 1 530 5 1 530 5 * ± 4% This indicative technical data sheet is not a contractual document. SC000071_0_22B_CELINE_RCIA_ASM E_WT

Vacuum Insulated vertical cryogenic CO 2 & N 2 O Tanks REF NOMENCLATURE ND W1 Bottom filling valve ND40 W2 Top filling valve ND40 S4 Line safety valve 1/4 E2 Filling connection ND40 E4 Filling connection ND40 S1 Inner vessel safety valve ND15 IR 3-way valve ND15 M Pressure indicator N Level indicator RI Low shut-off valve RE Equalizer valve RS High shut-off valve W41 Full trycock valve ND15 LP Outer vessel protection device BV Vacuum connection VV Vacuum probe connection 1/8 W8 Liquid withdrawal valve ND25 / ND40 BR Withdrawal connection ND25 P1 Purge valve ND15 RL Pressure limiter 1/2 V21 Vent valve ND15 V3 Withdrawal pressure valve ND15 BR1-BR2 Pressure coupling This indicative technical data sheet is not a contractual document. SC000071_0_22B_CELINE_RCIA_ASM E_WT

FLOW DIAGRAM This indicative technical data sheet is not a contractual document. SC000071_0_22B_CELINE_RCIA_ASM E_WT

Vacuum insulated vertical cryogenic CO 2 and N 2 O tanks CRYOLOR ASIA PACIFIC Pvt. Ltd.: + 91 (44) 674 11 788, WEB www.cryolor.com, E-mail : info@cryolor.com 3 rd January 2014 This indicative technical data sheet is not a contractual document. SC000071_0_22B_CELINE_RCIA_ASME_CAP

Vacuum insulated vertical cryogenic CO 2 and N 2 O tanks REF OPTION ND OP1001 W3 Equalising / Filling valve Equalising / Filling valve ND40 S5 Line safety valve 1/4 OP0601 Vacuum measuring device JV Vacuum thermocouple connection 1/8 OP0501 Liquid analysis connection Pa Liquid analysis valve ND15 Ra Quick connection OP1401 Condensing coil C Condenses the gas phase by passing refrigerant liquid throught coil in gas phase of inner vessel ND15 OP1402 OP1403 Refrigeration unit (Countries with ambient temperature < or = 30 C during a long time) Refrigeration unit (Countries with ambient temperature > 30 C during a long time) BF Connection to coil ND15 PSL Pressure sw itch, increasing pressure shut dow n indicator, setting 20 bar GF Refrigerating unit : 145W (RCV-RCI 3, 6, 10), 250W (RCV-RCI 21, 27, 33, 63) AC Pow er source required. 230VAC OP1501 Electric pressure raising coil : continuous flow rate at 16 bar : 400 Kg/h V1-V2 Isolating valve ND15 S2-S3 Line safety valve 1/4 F-RP Filter and pressure regulator - 16 bar 1/2 RMP Pressure raising coil : 2000W - 400V AC ND15 I Electrical control box w ith alarm light and manual general pow er stop TC - TSH Safe and regulation thermostatic units OP1502 Atmospheric pressure raising coil Continuous flow rate at 16 bar during 8 hours : 120Kg/h (RCV-RCI 3, 6, 10) / 230 Kg/h (RCV-RCI 21, 27, 33, 63) V1-V2 Isolating valve ND15 S2-S3 Line safety valve 1/4 F-RP Filter and pressure regulator - 16 bar 1/2 RMP Atmospheric pressure raising coil ND15 OP1801 Pressure switch + alarm PSL Pressure sw itch, decreasing pressure shut dow n indicator, setting 8 bar K Sound and light alarm AC Pow er source required. 230VAC OP2302 Doubling of filling valves W11-W21 Isolating valve ND40 S7-S8 Line safety valve 1/4 OP2401 Pump withdrawal and return outlet W81 Pump return valve (RCV-RCI 3, 6, 10, 21, 27, 33, 63) ND25 BR Withdraw al connection (RCV-RCI 3, 6, 10, 21, 27, 33, 63) ND25 W8 Pump inlet valve (RCV-RCI 3, 6, 10)ND25 Pump inlet valve (RCV-RCI 21, 27, 33, 63) ND40 BR1 Withdraw al connection (RCV-RCI 3, 6, 10) ND25 Withdraw al connection (RCV-RCI 21, 27, 33, 63) ND40 OP2402 Additional pump withdrawal and return outlet W71 Pump return valve (RCV-RCI 21, 27, 33, 63) ND25 BR Withdraw al connection (RCV-RCI 21, 27, 33, 63) ND25 W51 Pump inlet valve (RCV-RCI 21, 27, 33, 63) ND40 BR1 Withdraw al connection (RCV-RCI 21, 27, 33, 63) ND40 S41 Line safety valve 1/4 V31 Withdraw al pressure valve ND15 CRYOLOR ASIA PACIFIC Pvt. Ltd.: + 91 (44) 674 11 788, WEB www.cryolor.com, E-mail : info@cryolor.com 3 rd January 2014 This indicative technical data sheet is not a contractual document. SC000071_0_22B_CELINE_RCIA_ASME_CAP