AA100 Acoustic Actuator

Similar documents
User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

CF-SERIES HIGH FLOW REGULATORS

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

TrekMill USER'S MANUAL MM5050

Installation, Operation & Maintenance Manual

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

OWNER'S MANUAL. Copyright 1999 ATS - All Rights Reserved

COMBAT SWIM BOARD. RJE International, Inc. TAC-300 Revision C. RJE International August 3, TAC-300 Revision C

In Vivo Scientific, LLC INSTRUCTION MANUAL

Apex Evaporator Manual

Vessel Installation and Operating Manual

RJE INTERNATIONAL, INC.

SSS SWEEPERS MODELS MS-31 & MS-39

ROPV R40 E Series User Manual

USER GUIDE TO POWER ASSISTED BIKES

R E D I C O N T R O L S

WARNING NOTES TABLE OF CONTENTS

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Inflatable Stand Up Paddle Board Manual

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

Accu-Tab Systems 1000 Series by Axiall Corporation

User Operation Manual and Safety Instructions

OWNER'S MANUAL. Copyright 2003 GAMMA - All Rights Reserved

Installation and Operating Manual

IMPORTANT CO2/ HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES. Tank valves must be installed or removed by qualified personnel.

Interface Devices, Inc. Hydraulic Mini Mule

trigger magazine release

Installation and Operation Manual

DIVER NAVIGATION BOARD. RJE International, Inc. RJE International Feb 1, TAC-100D Revision 10

6 & 8 Bubble Panel Installation Manual

Model No Product Name Handpiece Only Complete System

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

User Manual GRI- 1500Li

Accu-Tab Systems 2000 P Series by Axiall Corporation

NOTES TABLE OF CONTENTS

DPC-30 DPC-100. Reference Manual

POWER ASSISTED BICYCLES OWNERS MANUAL

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

453 Series Steam Heated Vaporizing Regulator

Ocean Technology Systems ComBox

DEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

Issue OWNER S MANUAL. GAMMA RACQUET SPORTS GAMMA Sports All Rights Reserved

Cocoa Patio Pond with Lit Spillway

! Warning, refer to accompanying documents.

Thank you for choosing Xuma.

SSS SWEEPERS MODELS MS-21 & MS-29

Underwater Housing for Canon EOS M

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

Marschalk Model # 94000

602 STRINGING MACHINE OWNER'S MANUAL

Advanced Test Equipment Rentals ATEC (2832)

HAS2400 Hepa Air Scrubber

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS

J Air and Water Kit Instructions Part# 02584

USER MANUAL ELECTRIC BLOWBACK SYSTEM. Rev LIMITED WARRANTY

6 digital caliper with case

WARRANTY, QUICK START GUIDE

TABLE OF CONTENT IMPORTANT HPA AIR TANK SAFETY INSTRUCTIONS AND GUIDELINES RYSE ON/OFF ASA GETTING STARTED O-RING LIST SCREW LIST MICRO SQ BOARD

LSA-BAWMBL. Wall-Mounted Boom Arm INSTRUCTIONS

INSTRUCTION MANUAL GAS TRAK

Vevazz. Operation Manual. Vevazz, LLC Rancho California Road. Suite Temecula, CA Phone: (773) Fax: (888)

Sweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC.

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

TITAN FLOW CONTROL, INC.

SP-110 Autopilot OPERATION

PBT1100 POWER BANDING TOOL

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

Revolution Gurney Attachment

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

INSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT)

PPS PORTABLE POWER SUPPLY

200 STRINGING MACHINE

Operating Manual. Model MP-4R and MP-4RSS MULTI-PAK TM RESCUE AIR CARTS Manual No. PAK013 (Rev 1 January 2001)

DEEPSEA. LED Micro SeaCam POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA

EVO Solid Downtube. Operators Manual for Downtubes fitted with zinc plated springs June 2004

INSTRUCTIONS warranty watch care

This document to be used with Hurley traditional Davits

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL EM Washington Street Melrose, MA Phone Toll Free

92831 TEL: (714) FAX:

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

FLANGED TWO-PIECE BALL VALVES

A C Sipper. Installation and Operation Manual. Rev Part #

RAM 4021 Operation Manual

High Power Commercial Blenders

OPERATING INSTRUCTIONS V 5.3

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

USERS MANUAL. Manufactured by MacDev Paintball - Australia macdev.net

9A5N Solid State CW Paddle

Transcription:

AA100 Acoustic Actuator Operating Manual REV. A, September 2001 COPYRIGHT 2001. ALL RIGHTS RESERVED

Return Procedure It is necessary to obtain from ORE Offshore a Returned Material Evaluation (RMA) number prior to returning equipment. This is to assist tracking and arrival recognition. Follow the procedure listed below when returning U.S. origin goods to prevent delays and additional costs on Returned American Goods. New Import Procedure/Returned American Goods 1. All shipments must be accompanied by two copies of your commercial invoice showing value of material and any reason for return. * Whenever possible, please send copies of original export shipping documents with the consignment. 2. If the value is over $1,000.00, the following shipper s oath must be sent with the invoices. (This can be typed on the invoice or on a separate letterhead.) I,, declare that the articles herein specified are, the growth, produce, or manufacture of the United States; that they were exported from the United States; From the Port of, on or about ; that they are returned without having been advanced in value or improved in condition by any process of manufacture or any other means, that no drawback, bounty, or allowance has been paid or admitted thereof. Signed 3. If more than one part per consignment, a packing list must also accompany the shipment. It is acceptable to combine the commercial invoice and packing list as long as the contents of each carton are clearly numbered and identified on the commercial invoice. 4. Consign all air freight shipments to ORE Offshore in care of Intercontinental Air Frt., Inc., Logan Int l Airport, East Boston, Mass. 02128. 5. If the equipment is property of ORE Offshore please insure for full value. 6. Route via Logan International Airport only as the final destination. 7. Mail one invoice, packing list and copy of airway bill to ORE Offshore upon shipment. 8. Please refer to issued Returned Material Evaluation number on all documents and correspondence. 9. Air freight must be prepaid on all returns. ORE Offshore 4 Little Brook Road West Wareham, MA 02576 Tel: (508) 291-0960 Fax: (508) 291-0975 Email: sales@ore.com

Standard Commercial Warranty All equipment manufactured by ORE Offshore is warranted against defective components and workmanship for repair at the plant in West Wareham, Massachusetts, free of charge for a period of one year after shipment. Shipping costs are to be borne by the customer. Malfunction due to improper use is not covered in this warranty and ORE Offshore disclaims any liability for consequential damage resulting from defects in the performance of the equipment. No product is warranted as being fit for a particular purpose and there is no warranty of merchantability. This warranty applies only if: (i) the items are used solely under the operating conditions and in the manner recommended in Seller s instruction manual, specifications, or other literature; (ii) the items have not been misused or abused in any manner or repairs attempted thereon; (iii) written notice of the failure within the warranty period is forwarded to Seller and the directions received for properly identifying items returned under warranty are followed; and (iv) the return notice authorizes Seller to examine and disassemble returned products to the extent Seller deems necessary to ascertain the cause for failure. The warranties expressed herein are exclusive. There are no other warranties, either express or implied, beyond those set forth herein, and Seller does not assume any other obligation or liability in connection with the sale or use of said products. Any product or service repaired under this warranty shall be warranted for the unexpired portion of the original warranty period only. Equipment not manufactured by ORE Offshore is supported only to the extent of the original manufacturer s warranty.

Acoustic Actuator Functional description The ORE Offshore model AA100 acoustic Actuator has been designed to provide a reliable and cost effective means of remotely actuating a submerged device (relay, solenoid, blasting cap, squib etc.). This product excels in the role of straightforward acoustic solutions in the short duration, shallow water market. Under favorable conditions, these devices provide the user with means of acoustic activating devices at slant ranges in excess of 5 kilometers. The model AA100 acoustic actuator is small, lightweight and has been designed to present a minimal magnetic signature. This product is simple to use and no tools are required to arm and operate the system. Operation of the model AA100 requires only that it be switched on, connected to the device to be actuated and then sent its unique command code from an ORE Offshore deck unit. The AA100 is compatible with ORE Offshore and EdgeTech deck units: 8011, 8011A, 8011B, 8011XS and AMD200. The acoustic command code structure employed in these devices is ORE Offshore s field proven BACS (binary acoustic command) command format. BACS commands are 16 bit, FSK encoded tone bursts, there are minimum transition requirements and no command is re-issued. This command structure has been shown to be both secure and reliable it has been widely accepted by the oceanographic community. Command descriptions ARM: After receiving the ARM command the unit will charge up the firing capacitors this takes 30 seconds after which the fire circuit will be enabled. When the AA100 is charging the output stage, it will not act on any commands the receiver is locked out for the entire 30-second charge period. The system will remain armed for 5 minutes, during this time the fire circuit remains charged and will fire if the fire command is received. After the 5 minute armed period, the system discharges the capacitors and must be re-armed before firing. FIRE: The AA100 unit will not act on a FIRE command unless the system has been armed and the 5-minute timeout has not elapsed. If the fire circuit is charged the system will fire immediately upon receiving a FIRE command.

Internal On / Off Switch Internal On /Off Switch The internal on / off switch is used to power up the system. When the switch is turned on the system is ready for programming and will hold the program that has been loaded. The system will not execute the program or act on any commands until the external on / off switch is in the on position. Be sure the External On / Off switch is in the Off position before installing the electronics in the pressure housing. Operating Modes There are 4 operating modes available in the AA100. They are described below. These modes are programmed and entered by using the rotary switches and the push button switch on the electronics board inside the AA100. The system must be programmed within 1 minute of turning it on with the on/off switch inside the housing. If the unit is turned on but the programming button and rotary switches are not touched or changed then the system defaults to Mode 1. If the mode is to be set to something other than default, a small flat bladed screwdriver is required to change the rotary switches. The position of the rotary switches does not matter unless the program button is pressed within 1 minute of turning the system on. If the program button is pressed within 1 minute of power up the system will read the position of the rotary switches and set the

mode and timer accordingly. On power up (Switching the internal On / Off switch to the on position) the internal on board LED will flash once, if the Program Button is pressed within 1 minute after this flash the LED will flash once more indicating that and mode and timer switch settings are being loaded. After the mode is set the internal LED will flash the number of times to indicate the mode that was set. 1 flash equal s mode 1, 2 flashes equals mode 2, 4 flashes equals mode 4, and 8 flashes equals mode 8. It is best to set the rotary switches before turning the system on, this is simply to make it easier to program the unit within the 1-minute timeout. Remember the position of the switches doesn t matter unless the program button is pressed. In the event of an improper mode setting (an unsupported or unimplemented switch position) the led will flash 10 times quickly and return to the default Mode 1. Please read the mode descriptions below carefully. Mode Switch LSD Timer Switch Program Button MSD Timer Switch Internal LED Indicator Mode 1 This is the default mode the system will power up in this mode unless the programming button is pressed. The system will enter this mode if the mode rotary switch is in the 1 position when the program button is pressed. The MSD and LSD timer rotary switches have no effect in Mode 1. In mode 1 when the external on / off switch is turned to the on position the unit will not respond to any commands for 10 minutes. After 10 minutes the system will be ready and able to receive an arm command and then a fire command. If the external on / off switch is turned off the system can be turned on again however the

10 minute time out will start again. This time out is intended to allow users to evacuate the area before any arming and or firing can take place. Mode 2 This mode is similar to Mode 1. The system will enter this mode if the mode rotary switch is in the 2 position when the programming button is pressed. The timer rotary switches are used to set the delay time before the system is capable of being used. In mode 2 when the external on / off switch is turned to the on position the actuator will act on commands received only after the time set on the MSD and LSD timer switches has elapsed. The delay can be set from 0 to 99 minutes. The MSD switch indicates 10-minute intervals and the LSD indicates 1-minute intervals. The unit will not respond to any commands for number of minutes set on the timer switches. After the timeout the system will be ready and able to receive an arm command and then a fire command. If the external on / off switch is turned off, the system can be turned on again however the time out will start again. This time out is intended to allow users to evacuate the area before any arming and or firing can take place. Mode 4 This mode is similar to Mode 1 and 2. The system will enter this mode if the mode rotary switch is in the 4 position when the program button is pressed. The MSD and LSD timer rotary switches are used to set the delay time before the system is capable of being used. In mode 4 when the external on / off switch is turned to the on position the actuator will act on commands received only after the time set on the timer switches has elapsed. The delay can be set from 0 to 99 days. The MSD switch indicates 10-Day intervals and the LSD indicates 1-Day intervals. The unit will not respond to any commands for number of days set on the timer switches. After the timeout the system will be ready and able to receive an arm command and then a fire command. If the external on / off switch is turned off the system can be turned on again however the time out will start again. This time out is intended to allow users to deploy systems for longer periods of time. It will normally be used in study type mooring deployments. It is intended for recovery of deployed instruments. Mode 8 This mode is the timed fire mode. It intended for use when a deck unit is not available or the acoustics in the area are bad. In the mode the system will fire immediately after the timer has elapsed. There is no command required. The system will enter this mode if the mode rotary switch is in the 8 position when the programming button is pressed. The timer rotary switches are used to set the delay time before the system charges and then fires. 30 seconds before the time is elapsed the fire circuit will start charging and then the circuit will fire. The delay can not be set to 0 minutes. If the delay is set to 0 minutes the system will report a mode error (10 quick flashes on the Internal LED) and go to the default mode. The delay can be set from 1 to 99 minutes. The MSD switch indicates 10- minute intervals and the LSD indicates 1-minute intervals. In mode 8 when the external on / off switch is turned to the on position the actuator will start timing and fire accordingly. Turning the external on / off switch to the off position will disable the system.

External On / Off Switch Switch Collar Switch Shaft External On / Off Switch The external on / off is a watertight rotary switch. It can be operated underwater as well as on the surface. The system is off when the switch shaft is turned fully counterclockwise. The system is on when the switch shaft is turned fully clockwise. Total travel of the shaft is 90 degrees. The surface of the collar and the switch shaft are knurled for maintaining an easy grip while using the switch. To use the switch, hold the collar with one hand and rotate the switch shaft with your other hand. The switch shaft will stop at either the on or the off position depending on the direction of rotation. Be sure the External On / Off switch is in the Off position before installing the electronics in the pressure housing.

External LED When the system is turned on using the External on / off switch the External Led will flash a number of times indicating which mode is set. It will also begin timing if a mode, which includes timing, is active. After 2 seconds the External LED will flash the number of times equal to the mode set. External LED Battery Replacement and O-ring Maintenance The AA100 requires minimal maintenance. The O-rings should be carefully inspected and replaced periodically. The batteries should also be replaced periodically. The battery is a Long life lithium power cell. To achieve the life specified only ULTRALIFE model #U9VL-FP should be used. The O-rings are 2-132N70. Whenever installing O-rings, be sure to thoroughly inspect the new O-ring for defects. Opening the Housing and removing the electronics Assembly Only open the housing in a clean dry environment. Be sure the housing and collar assemblies are clean. Turn the external on / off switch to the off position. Unscrew the collar on the cable end of the housing. Gently slide the end cap with the attached electronic assembly out of the housing taking care to not scratch the O-ring surfaces on

the throat of the housing. It may be necessary to press the end cap from side to side and or rotate it to get the assembly out. Once the assembly is out far enough then slide the internal on / off switch to the off position. It is not necessary to remove the external on / off switch end cap to change the batteries or to program the unit. In order to replace the battery cut off and dispose of the tie wrap. Disconnect the cable from the battery and dispose of the battery properly. Plug the new battery into the cable and replace the tie wrap. Be sure the isolation rubber pad is still in place under the battery. When replacing O-rings, be sure to inspect all O-ring surfaces as well as the O-rings for scratches and or debris, which may cause a leak. Apply O-ring lube to all surfaces and the O-rings. (A light coating is all that s required) When you are returning the electronics to the housing please be careful to not scratch the O-ring surfaces inside the housing. Slide the electronics all the way into the housing and then replace the collar. Servicing the External On / Off Switch To remove the External on / off switch for service and to replace the O-ring hold the Switch in the center of its travel (halfway between on and off) while removing the collar. When the collar has been removed the Shaft can be slid out of the housing. Be careful to not scratch any O-ring surfaces. After replacing the O-ring and inspecting the assembly replace the shaft and the collar. Electronics Assembly End Cap and Collar On / Off Switch Assembly End Cap and Collar Collars On / Off Switch Shaft