Cape Cod Community College Studio Theatre Approved Seating & Stage Configurations Tilden Arts Center, Lower Level West Barnstable, Massachusetts

Similar documents
City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 8 RECREATION FACILITIES

IBC: 404.1, 404.9, , , , , , TABLE

CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS

MSC Guidelines for Review of Emergency Evacuation Plans (NVIC 8-93)

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted.

OFFICE SAFETY. Environmental Health and Safety. Greg Hogan Oklahoma State University Environmental Health and Safety

ADA Access Standards for Swimming Pools, Wading Pools, and Spas

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ARCHITECTURAL

EHS Workplace Inspection Checklist (Ref. SOP QMS-080; EHS-010)

Chapter 5. General Site and Building Elements

dpd Seattle Permits Tip Getting a Grip on Handrails PURPOSE OF HANDRAILS

Segment Number Quick Pathways Accessibility Tool. Name of Street: Segment Identification:

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT. Number: 2015 IFC Effective Date: February 1, 2017 Page 1 of 5

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

Circular Turning Space. 8 Significant Changes to the ICC A

ADA Library Accessibility Checklist

WILLIAMS UNIFIED SCHOOL DISTRICT TRANSPORTATION SAFETY PLAN Board approved: April 21, 2016

CUSTODIAL Safety Inspection Checklist

PROPOSED CONVERSION OF MYRTLE BEACH MIDDLE SCHOOL TO MYRTLE BEACH ELEMENTARY SCHOOL PMH. PIKE McFARLAND HALL ASSOCIATES, INC. ARCHITECTS & PLANNERS

SAFETY PROGRAM MANUAL INJURY & ILLNESS PREVENTION PROGRAM

Sign Meaning as viewed from in front of the sign Examples of locations

Implementing the Three Es of School Zone Traffic Calming

NEW ZEALAND BUILDING CODE. In relation to Tredsafe

CURBSIDE ACTIVITY DESIGN

INSPECTING THEATRICAL RIGGING EQUIPMENT KEEPING THE STAGE SAFE

CTC Area of study Climbable Guards 2007/2008 Code Changes SECTION GUARDS

Southern Bleacher Company: Experience You Can Trust

Subparts D and I Walking-Working Surfaces & Personal Protective Equipment Final Rule

WHS OHS HAZARD REGISTER (SITE AND OFFICE OPERATIONS)

Recreational Camp Emergency Plans for Incidents and Natural Disasters

THE TLC COMPANIES. Self Inspection Program. Self Inspection. Program. Revised 12/13/2002 DC00026

Accessible Swimming Pools and Spas

2016 Maryland 4-H Robotics Engineering Challenge

POOL AND SPA REPLASTERING AND/OR REMODELING REQUIREMENTS

Be respectful. Be responsible. Be safe

ADA COMPLIANCE CHECKLIST (RESTAURANT) Meet Fail N/A. Parking Lot

X-PRESS STAGE SYSTEM OWNER S MANUAL. TOOLS REQUIRED Allen Wrench (provided)

OFFICE SAFETY ESSENTIALS

STRIDER THEATER INFORMATION & POLICIES FOR STUDENT PRODUCTIONS

(g)(1) Space about electric equipment.

NESD Lifts and Transfers Manual

NO wiring shall be above the pool within 10, measured horizontally, or under a pool within 5, measured horizontally.

University of St Andrews. Fire Safety Occupancy Limits for University Venues

OAK HILL SCHOOL BUS POLICIES AND PROCEDURES

newly constructed and altered recreation facilities guidelines for newly constructed and altered buildings and facilities subject to the ADA.

Permit and Inspection Requirements for Swimming Pools

Grip-Lock Chock Repair Decision Instructions: Procedure and Examples (June 2013)

COMMONWEALTH OF MASSACHUSETTS ENERGY FACILITIES SITING BOARD DEPARTMENT OF PUBLIC UTILITIES NOTICE OF ADJUDICATION NOTICE OF PUBLIC COMMENT HEARING

Wall Bracing Examples: Building #1 One-Story

ADA on Construction. Guidance for Section C Plan Preparers

COMPLIANCE GUIDELINES FOR. Departmental Health and Safety Inspections

Events Basics original

2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

Accommodating Pedestrians in the Work Zone

Plymouth Multiple Auditorium Kingdom Hall. Operating Manual

MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE. Permit and Submittal Requirements for Fireworks, Pyrotechnic, or Flame Effect Displays or Productions

"STEEL FRAMED" ALUMINUM PANEL SHIELDS

1 The central area of the bar looks out onto the Boston Red Sox field at Fenway Park. pg. 1. (Photo Source: Author's personal collection)

Bicycle Safety Skills

The Community Loft. Model 2 Additions

Bridgeport High School Auditorium 5:00 PM-10:00 PM. General Guidelines

OS11. EXHIBITION Guide. IssuE 1 - March 2015

Date Issued: 27 September 2018

ONLINE SAFETY TRAINING PROGRAM SUMMARY

EVENT HANDBOOK SECTION 2: Buildings & Spaces on Campus (incl. hours & capacities)

Aquatic Facility Evaluation City of Merriam, Kansas. Kyle A. McCawley, P.E. Larkin Aquatics 4/9/2014

School Bus Safety Research: Physical Capabilities of Young Children

WORKPLACE SAFETY INSPECTIONS TABLE OF CONTENTS INTRODUCTION...2 OBJECTIVE...2 REFERENCES...2 PREREQUISITES...2 PRECAUTIONS...2 CHECKLISTS...

Norton Shores Building Division 4814 Henry Street, Norton Shores, Michigan Telephone: (231) Pool Requirements

CAUTION BIKE ROUTE AUTOMATIC DOOR BIKE CROSSING

Y TWR TECHNICAL PRODUCTION SPECIFICATION. Copyright 2017 Music Theatre Wales & Theatr Genedlaethol Cymru Musictheatre.wales Theatr.

Penns Valley Marching Rams. Parent Guide

Palmer township, Pennsylvania. Pool & Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

Personal Emergency Evacuation Plan Questionnaire for Disabled Staff

Advisory Circular. Demonstration of Emergency Evacuation and Ditching Procedures Airline Operations

SECTIONALS GUIDE. U-Chaise Sectional* Consists of (L to R): 1 Left-Arm Chaise, 1 Armless Sofa and 1 Right-Arm Chaise

2019 IIHF Video Goal Judge System Guidelines

Section 6. Off-street Bicycle Space Regulations

From the Archives: The Bleacher Bar at Fenway Park: Transforming a Former Indoor Batting Cage Into a Unique Eatery and Bar By Graham Ruggie

Clyde Brown Elementary School Millis, MA

Babe Ruth Softball Divisions Facilities Planning Guide. Field Layout Checklist General Considerations Tournament Considerations

ada compliance swimming pool Compliance guide

H Robotics Engineering Challenge

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS

Global Lift ADA Compliance

Midday Event Volunteer Manual (Master Classes and Café Conversations)

ADA Operations Contact Info

Social Story Relaxed performances at The Court Theatre

Example Applications of the Proposed Medical Diagnostic Equipment Accessibility Standards

If you have any questions or concerns please contact me at or

RISK ASSESSMENT Title of programme. 4. Control measures Risk assessment

CAMELBACK COLLECTION. a b c d e f g h i j k l m n o p q r t u s

DEPARTMENT OF THEATRE AND DANCE CALIFORNIA STATE UNIVERSITY, FULLERTON

City of Auburn Hills Senior Transportation Program. Riders Guide

RESIDENTIAL SWIMMING POOL REQUIREMENTS

Physical Activity. Good posture. Sitting guidelines. Rising from a chair

See Figure 38, Existing Nonmotorized Connections.

Application Checklist (Incomplete applications will not considered) Completed application form with two signatures.

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

CPWR - The Center for Construction Research and Training. Fall Hazard Identification and Control Audit of the Aria Building. City Center Project

Transcription:

Cape Cod Community College Studio Theatre Approved Seating & Stage Configurations Tilden Arts Center, Lower Level West Barnstable, Massachusetts This booklet demonstrates the approved theatre configurations based on a Massachusetts State Building Code review (MSBC 780 CMR 6 th Ed.) and coordination with the State of Massachusetts Department of Public Safety Building Inspector. All productions hosted at the CCCC Studio Theatre must comply with ONE of SIX configurations. The diagrams show the maximum allowable audience seating size and layout. Six configurations are approved, ranging from 62 217 audience seats for each configuration. No other configurations have been approved by Cape Cod Community College. Proposed Set plans shall be given to Cape Cod Community College Technical Director for approval and compliance with these guidelines prior to construction. CCCC Facilities shall inspect the facility prior to each performance for compliance. Non-complying configurations will not be allowed and may result in the cancellation of a performance or event. In addition to the seating and stage configurations that follow, all egress aisles and exits (noted in the attached diagrams as s) must remain clean, unimpeded and visible at all times. A three foot wide (36 inch) minimum path across the front of the audience seating leading to the exits must be maintained. No one may stand or sit on the stairs or in front of Fire Exits. Fire Doors must remain closed at all times. Push bars on Fire Doors must remain free, clear and uncovered. Do not hang masking or other that obscures the Exit Signs, Fire Alarms, sprinklers or other life safety devices. Illuminated Exit signs may not be blocked, turned off, lamped down or gelled. Pull Stations and Fire Extinguishers must be visible and easily accessible at all time. For additional information about the facility (Box Office, loading, Sound/Lighting Equipment), refer to the Tilden Arts Center Technical Specifications available from Tilden Arts Center Technical Director. Page 1

Potential HC space (36 x60 ) Configuration 01 131 seats maximum + 4 Handicapped Accessible Spaces (required minimum to be provided) 775 SF stage area appx. See Base Platform Layout on page 4 for more information. When laying out chairs, begin at the curtain for chairs on the north & south portions around stage. For area to west of stage, chairs should be centered on the stage. Curtain (existing) New 34 deep platform Wenger chair w/ automatic rising seat Single 89 Double 18 Triple 2 Page 2

Configuration 02 62 seats maximum (36 row spacing) 1220 SF stage area appx. Wenger chair w/ automatic rising seat Potential Performance Area Potential HC space(36 x60 ) If not utilized, a standard Single Chair may be used. Ramp or lift required to allow for HC Accessible seats, coordinate with CCCC Single 28 Double 14 Triple 2 Page 3

Potential HC space(36 x60 ) Wenger chair w/automatic rising seat Configuration 03 146 seats maximum 840 SF stage area appx. Designation A = 34 x84 8 C = 34 x48 2 D = 34 x24 0 New 34 deep platform Single 112 Double 14 Triple 2 Page 4

Configuration 04 95 seats maximum 1430 SF stage area appx. Wenger chair w/automatic rising seat Designation A = 34 x84 4 C = 34 x48 1 D = 34 x24 0 Potential HC space (36 x60 ) New 34 deep riser Single 68 Double 12 Triple 1 Page 5

Potential HC space(36 x60 ) Configuration 05 Dinner Theater 96 seats maximum 4 HC Accessible Spaces 300 SF stage area appx. Designation A = 34 x84 8 C = 34 x48 2 D = 34 x24 2 Single 96 Table Count Tables at HC Spaces must be 27 clear from the floor to underside of the table and be 28 34 high at top surface e = 18 x60 15 f = 18 x84 13 g = 18 x96 9 Page 6

Potential HC space(36 x60 ) Configuration 06 Coffee House 217 seats maximum 375 SF stage area appx. Designation A = 34 x84 16 C = 34 x48 4 D = 34 x24 2 Single 150 Double 29 Triple 3 Page 7