Shut-off valve Type QDV

Similar documents
Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves Type SFA 15 and SFA 15-50

Pressure regulating valves Types OFV, OFV-SS

for for Industrial Refrigeration

Hand operated regulating valves Types REG-SA and REG-SB

Safety relief valves Type SFV 20-25

Hand-operated regulating valves in stainless steel Types REG-SA SS and REG-SB SS

Safety relief valves, type SFA 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves, type SFA 15

Safety relief valves Type BSV-8

Safety relief valves SFV 20-25

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Regulating valves REG-SA and REG-SB

Pilot valves for pilot operated servo valves

Float valves Types SV 4, SV 5 and SV 6

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

Float valves Types SV 1 and SV 3

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid Valves, one - or two step, on/off ICLX

Shut-off Liquid level and regulating valves for for Industrial Refrigeration

Valve station ICF 15, ICF 20, ICF 25, ICF 50 and ICF 65

Liquid level regulating valves Types PMFL / PMFH and SV

Dual position solenoid valve Type ICSH 25-80

Liquid level glasses, type LLG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

AVP-F. p setting range (bar) Code No. 003H6200

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

AVPQ/AVPQ-F, PN 16. Application

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

CASH VALVE TYPE KP BACK PRESSURE VALVES

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

Capacities Valve Station, type ICF 15, 20, 25

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and Position.

Expansion Thermometers Stainless Steel Series, Model 70

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

STAD. Balancing valves DN 15-50

Materials : Stainless steel ASTM A351 CF8M

Armatures for analytical probes

ASYBCO 90 O ELBOW LONG RADIUS O.D. I.D.

Presetting Valve Type RA-N with Flange Connection

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

kyone for All - Unique Mixproof

Seated valves VRB 3, VRG 3

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.

Series MG Mixing Tubes

STAD. Balancing valves DN (MD60, MD61, MD62)

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Description Advanced Features Typical Applications

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Pressure transmitters EMP 2

Barcol-Air BRM Radiant Module

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

STAD-C. Balancing valves DN 15-50

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

Technical Information Cleanfit CUA451

HP/UHP Spring-Loaded Regulator

Refrigerant Gases Valves

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

STAP. Differential pressure controller DN 15-50

Automatic balancing valves ASV

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX

Leak free Pipe Rupture Valve for Excavators

Slam Shut Valves SCN

Pressure switch and Thermostat CAS

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

Norval Pressure regulator

Valve Station ICF 15, 20 and 25

ZUERCHER MRCib Series

Materials : Carbon steel ASTM A216 WCB

Condensing pressure regulator, type KVR Differential pressure valve, type NRD

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Air Operated Hydraulic Pumping Systems to 50,000 psi

B74G - EXCELON Modular System General purpose filter/regulator

GIRARD EQUIPMENT, INC. Specialty Valve Manufacturers for Tank Trailers since 1952

Precision and Instrument Regulators 1/4" port size

JUMO dtrans p30 Pressure Transmitter

Pressure reduction controller (PN 16, 25, 40)

Materials : Forged carbon steel A105N

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

Technical Data Sheet T 2025

shutoff valves 900 Series psig Manual Shutoff Valves

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

Transcription:

Data sheet Shut-off valve Type QDV QDV is a shut-off valve, designed particularly for draining oil from systems containing refrigerant (ammonia) under pressure. The valve will close immediately on release of the handle, thus protecting user and environment against unne cessary refrigerant leaks. The valve should as a rule be installed as illustrated in fig. 1. In order to pre vent hydraulic pressure building up between the stop valve and the QDV an integral relief device is included as part of the cone arrangement, which will open at approx. 16 bar (232 psig). QDV is designed to meet the safety demands specified by national and international authorities within industrial refrigeration. Features Applicable to R717 (ammonia). Meets the safety demands within industrial refrigeration Handle can be positioned 360 Built-in integral relief device opening over 16 bar g (proventing hydraulic pressure building up between shut-off valve and QDV). Can be supplied together with a stop valve for quick on site mounting (fig. 1). Max. operating pressure: 40 bar g (580 psi g). Temperature range: 50/+150 C ( 58/+302 F). Classification: DNV, CRN, BV, EAC etc. To get an updated list of certification on the products please contact your local Danfoss Sales Company. Oil Fig. 1 QDV Danfoss DCS (MWA) 2016.01 DKRCI.PD.KL0.B2.02 520H1199 1

Design Connections Available with the following connections: Inlet: Welding DIN (EN 10220) ½ in. FPT 3/4 in. FPT Outlet: G 3/4 in. pipe thread (ISO 228/1) ½ in. FPT 3/4 in. FPT Optional extras for outlet: Welding nipple DIN (EN 10220) Hose connection Other types of connection are available on request. QDV - SVA combinations Combinations of the QDV together with a dedicated SVA have been established for easy selection. Please study page 6 to find the code numbers for these combinations. Installation For further information refer to installation instruction for QDV. Technical data Refrigerants Applicable to R717 (ammonia). QDV is a backpressure dependent valve. If any tube or hose is mounted on the outlet of the QDV it has to be calculated to prevent blackpressure building up when relieving. For further information please see installation instruction for QDV. Flammable hydrocarbons are not recommended, for further information please contact your local Danfoss Sales Company. Temperature range 50/+150 C ( 58/+302 F). Pressure The valve is designed for: Maximum operating pressure of 40 bar g (580 psi g) Danfoss DCS (MWA) 2016.01 DKRCI.PD.KL0.B2.02 520H1199 2

Material specification QDV 15 No. Part Material DIN/EN ASTM 1 Housing Steel G20Mn5QT EN10213-3 LCC A352 2 Bonnet Steel St37-2 3 Spindle/Cone Stainless steel X10CrNiS18-9 4 Spring Steel 5 O-ring Cloroprene 6 O-ring Cloroprene S235JR EN 10025 S189 EN 10088-3 AISI 1015 AISI 303 Hose connection for outlet No. Part Material 12a O-rings Cloroprene (Neoprene) 12c Stub for hose - OD Ø15 mm Steel 12d Union nut - G 3/4" Steel Welding nipple connection for outlet No. Part Material 13a Al-packing Aluminium 13b Welding nipple - OD Ø21.3 mm Steel (S235JR) 13c Union nut - G 3/4" Steel Danfoss DCS (MWA) 2016.01 DKRCI.PD.KL0.B2.02 520H1199 3

Connections ØD 1 ØD 3 ØD 4 ØD 5 QDV 15 DIN 15 mm 12 36.5 16.7 21.3 in. 0.47 1.44 0.66 0.84 ØD 7 ØD 8 QDV 15 ½" FPT mm 34 36.5 in. 1.34 1.44 ØD 7 ØD 8 QDV 15 3/4" FPT mm 34 36.5 in. 1.34 1.44 ØD 1 ØD 3 ØD 8 QDV 15 DIN 15 mm 12 36.5 34 in. 0.47 1.44 1.34 FPT 1/2" 13.5 T OD T kv-straight m 3 /h Cv-straight USgal/min OD SVA-ST DIN 15 mm 21.3 2.3 in. 0.839 0.091 4.9 5.7 FPT 1/2" 13.5 T ID SVA-ST SOC ½ in. ID T L kv-straight m 3 /h mm 21.8 6.0 10 in. 0.858 0.235 0.39 Cv-straight USgal/min 4.9 5.7 L Danfoss DCS (MWA) 2016.01 DKRCI.PD.KL0.B2.02 520H1199 4

Dimensions QDV 15 (stand alone) QDV 15 mounted on SVA valve Valve size A C max E QDV 15 mm 45 185 109 in. 1.77 7.28 4.29 Ordering How to order The table below is used to identify the valve required. Type Inlet Outlet Code no. QDV 15 DN 15 DN 15 G 3/4 in. 148H3272 QDV 15 ½ in. FPT ½ in. FPT ½ in. FPT 148H3273 QDV 15 3 / 4 in. FPT 3/4 in. FPT 3/4 in. FPT 148H3274 QDV 15 DN 15 + SVA-ST DN 15 H-WHEEL* DN 15 G 3/4 in. 148H3310 QDV 15 ½ in. FPT + SVA-ST SOC ½ in. H-WHEEL* ½ in. SOC ½ in. FPT 148H3311 Fittings for hose connection - G 3/4" Fittings for welding connection - G 3/4" * Two valves are supplied in one box and should be mounted on site. The indicated inlet is for the stop valve - The indicated outlet is for the oil drain valve. 148H3451 148H3452 Important! Where products need to be certified according to specific certification societies or where higher pressures are required, the relevant information should be included at the time of order. Danfoss DCS (MWA) 2016.01 DKRCI.PD.KL0.B2.02 520H1199 5

Danfoss DCS (MWA) 2016.01 DKRCI.PD.KL0.B2.02 520H1199 6