MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Similar documents
DS MZ, MZF, MJF THREE-PORT SEAT VALVES

DS MB, MBF THREE PORT VALVES

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Seated valves VRB 3, VRG 3

2-port seat valves PN25 with externally threaded connections

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16

Pressure Independent Control Series

3-port seat valves with externally threaded connection, PN 16

Two-port valves, male threaded, PN25

2-port and 3-port valves PN 16

Two-port seat valves

2-port and 3-port seat valves, PN16

TW Temperature Control Valve

2-Port and 3-Port Seat Valves with Female Thread, PN16

3-way control valves VK 3

V311. Venta. Three-way Plug Valve, Flanged PN 16

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Pressure reducing valves Index

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

STA. Double regulating valves DN 15-50

SCA Series Inverted Bucket Steam Traps

VB-7263 Series. Application. Features. Applicable Literature

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

VBS-9263 Series. Application. Features. Applicable Literature

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

VB-7273 Series. Application. Features. Applicable Literature

Manual Actuated Boiler Blowdown Valves

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

SV5 Safety Valve Installation and Maintenance Instructions

776 Cryogenic Safety Valve

VZL valve - 2/3/4-way

DS05C,D,G Dial Set Pressure Regulating Valves

Series V48. 3-Way Pressure Actuated Modulating Valves. Product Bulletin. Features. Pressure balanced design. Free movement of all parts

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Seated valve for steam (PN 25)

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

TA-FUSION-P. NPT threads / ANSI flanges

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

Materials : Stainless steel ASTM A351 CF8M

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

HERZ-Motorised flow controler

Overview of types. Technical data

Overview of types. Technical data. Safety notes

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

STAP. Differential pressure controller DN

CLASS TLP Pressure Reducing Valve

C 10 Pressure Reducing Valve

BCV31 DN20 - Blowdown Control Valve

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

TA-H.U.B. Centralised balancing and control ENGINEERING ADVANTAGE

A t. VB-7323 Series. Application. Features. Applicable Literature. l/2 to 2 Screwed NPT SIEBE

Installation, commissioning and servicing instructions

STAP. Differential pressure controllers DN , ANSI flanges

Technical Data Sheet T 2025

differential pressure regulating valve - threaded

V43 Pressure Actuated Water Regulating Valve

756 Safety Relief Valves

Pressure Reducing Valve for Steam Type 2333 A

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

STAP. Differential pressure controller DN 15-50

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

STV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems.

TECHNICAL DATA. Page 1 of 12

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

D05 Pressure Regulating Valves

KTM 50 (DN ) Installation, maintenance and operating instructions

Hycocon. Technical information. Das Qualitätsmanagementsystem von Oventrop ist gemäß DIN-EN-ISO 9001 zertifiziert.

Products no longer available

PCMTV Pressure independent control valves, DN20-DN32 with integrated flow limiter for thermal emitters and differential pressure regulator

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Bermad Pressure Reducing. Model: 42T

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Type overview. R B2 en-gb subject to changes 1

STAD. Balancing valves DN 15-50

STA. Double regulating valves DN 15-50

PCTV/PCMTV/PCTVS15-25

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

STAG. Balancing valves Balancing valve with grooved ends DN

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

Engineering Data Sheet

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Twin & Triple Control Concealed Thermostatic Shower Valve

PC3_ and PC4_ Pipeline Connectors

TECHNICAL DATA CAUTION

Pressure Independent Control Valve (PICV) Fig DN15-32

Transcription:

01 These seat valves are of globe construction with a linear moving spindle and a modified parabolic characterised plug operating against the upper seat which controls flow quantity to suit the load. The lower part of the plug has a linear characteristic operating against the lower seat controlling the bypass quantity. This arrangement gives the optimum performance for both mixing and diverting applications. For the latter the valve must be fitted in the return. The valves are suitable for the control of hot or chilled water and brine or glycol solutions within the limits given in the table below. They are suitable for operation by the AVUM, AVUX and AVUE actuators only. For details of the actuators, refer to Data Sheets DS 3.001 and DS3.005. The range of valves fitted with appropriate Satchwell actuators will fully comply with all relevant European directives. SPECIFICIATIONS AND GUIDE TO SELECTION Valve Suitable Actuators - see DS 3.001 and DS 3.005 AVUX3202, AVUM3601, AVUE3304, AVUE3354 Group Size Type a Cv S Stroke Maximum differential Screwed Bronze ½ ¾ 1 1¼ 1½ 2 4402 4452 4501 4551 4601 4651 2.5 4 8 12 20 32 12.7mm (½ ) pressure (Dp) Control Medium Brine, 15% max. NaCl or CaCl 2 (freeze protection) Water Glycol Solution, 25% max. (freeze protection) Temperature limits Maximum internal pressure kpa Min Max kpa 1180 720 340 200 120 60 a Cv S = Flow in UK gal/min to produce 1lbf/in 2 pressure drop when the valve is fully open Kv S = Cv S x 1.03 Kv S = Flow in m 3 /hr to produce 1 bar pressure drop when the valve is fully open 100 Kpa 1 Bar = 1.02 kgf/cm 2 = 14.5 lbf/in 2 International Pressure Rating 2 C 120 C 1600 PN 16 (ND 16)

02 TECHNICAL SPECIFICATION ½ & ¾ 1 to 2 Pipe Connections Screwed BSP to BS 21 female - taper Screwed BSP to BS 21 female - parallel Characteristic Port 2 Modified Parabolic Port 3 Linear Rangeability Let-by 50:1 Based on:- % Cv at 1 lbf/in 2 pressure drop % Kv at 1 bar pressure drop Ports 2-1 Ports 3-1 0.0.5% max 0.1% max 0.5% Test Pressure 2400kPa Body Material Bronze: leaded gunmetal BS 1400 LG2 Seats Top: Integral with body Bottom: Copper alloy BS 2874 CZ 132 or BS 2871 CZ 110 Bottom: Leaded gunmetal BS 1400 LG2 Plug Copper alloy BS 2874 CZ 132 or BS 2871 CZ 110 Spindle Stainless Steel: BS 970 Grade 303 S42 Guide Leaded gunmetal BS 1400 LG2 Bonnet Integral with body Gland (non-adjustable spring-loaded) Packing chevrons: PTFE BS 4271 Grade B Scraper rings: PTFE BS 4271 Grade B Headers: Copper alloy BS 2874 CZ 132 or BS 2871 CZ 110 Spring: Austenitic Stainless steel BS 2056 302S26 Gland Nut: Copper alloy BS 2874 CZ 132 or BS 2871 CZ 110 Gland O Ring Ethylene Propylene Replacement 626-9-204 Gland Kit

03 GOOD DESIGN PRACTICE Control Medium The table on Page 2 lists suitable fluids and which valves are appropriate. Other fluids e.g. seawater, oils etc: Satchwell cannot accept responsibility for use of these valves with fluids other than those listed in table on Page 2. Detailed specifications of all materials in contact with the fluid are given in table on Page 2 and it is the responsibility of the specifier to check their suitability. Note that all brass components used in valve construction, which are in contact with the fluid, are manufactured from dezincification resistant materials. The valves are intended to be used in closed circuits; if the circuit is open e.g. mains water or from exposed cooling tower ponds, it is possible that a build-up of mineral deposits may impair the operation of the valve and frequent maintenance will be necessary. Appropriate precautions should be taken. MIXING AND DIVERTING APPLICATIONS VALVE SIZING The valve should have an authority of not less than approximately 0.5. That is, the pressure drop through the valve should be as near as practicable equal to the pressure drop through either of the parallel paths in which the flow quantity is varied.sizing charts are given in DS 4.950. INSTALLATION Warning - Steam or hot water hazard. Before isolated and relieve the pressure, work should Instructions for fitting actuator to valve are packed with the actuator. It is recommended that valve insulation covers should be fitted to conserve energy. Step-by-step installation instructions are packed with each valve and the cautions must be observed. These valves must always be installed with two inlet streams and one outlet stream i.e. as mixers. Reversal of this direction will cause vibration and water hammer which will damage both valve and actuator. For diverting applications the valve must therefore be fitted in the return pipe. The water will be diverted with respect to the load, but will mix in the valve. (See Fig.1 Schematic only.) MIXING DIVERTING 2 1 Fig. 1 Source of heating/cooling water 3 Source of heating/cooling water 3 1 2

04 Cautions Allow sufficient access for actuator and wiring. Avoid spindle pointing vertically downwards to avoid risk of condensation or leakage damaging actuator. Observe the upper ambient temperature limitation of actuators (50 C). Where fluid in valve exceeds 100 C actuator must not be above valve. Therefore valve should be mounted with spindle horizontal. Observe correct direction of flow through valve as indicated by arrow cast on body. Fit valve in return pipe for diverting applications. Regulating valves are recommended to be installed in the bypass pipe to each 3-way control valve, in addition to those for pump sets and branches etc. The system should be thoroughly flushed out to remove foreign matter before fitting the valve. Ensure system is efficiently vented, particularly for low flow rates. If fitting a ½ or ¾ VZX valve, ensure that not more than 13mm (½ ) of BSP thread is screwed into the valve, otherwise internal damage will occur, causing actuator malfunction and valve let-by. MAINTENANCE Warnings - Steam or hot water hazard. Before isolated and relieve the pressure. Work should The valve to actuator linkage nut located on the top of the valve spindle is preset and must not be adjusted. A periodic check of the valve should be made for general condition and leakage. For replacement gland kit see table on Page 2. When strainers are fitted the following recommendations should be observed: It is suggested that strainers should be fitted to protect the valves. The fitting of strainers is NOT a substitute for flushing the system out fully. Failure to fully flush the system can result in frequent clogging of the strainers. Strainer bodies for line sizes up to DN 50 (50mm) should be Bronze to BS 1400, PB1 or cast iron to BS 1452, class 180. Strainer pressure ratings should be at least 150% of the maximum pressure expected in the application. Strainer screens should be of a suitable stainless steel construction. The strainer screen should have a free area at least 250% of the line cross sectional area. The screen perforation diameter should be in the range of 0.7 to 0.9mm for sizes up to DN 50 (50mm) Strainers should be installed in parallel to enable online maintenance to be carried out.

06 DIMENSIONS mm (in) Valve Size A B C D A B ½ 181 48 62 36 ¾ 182 42 74 43 1 186 76 97 51 1¼ 191 76 108 72 1½ 194 76 121 77 2 202 89 145 93 Note: Allow 50mm between top of actuator and nearest obstruction to permit fitting and removal of actuator. C D Warnings - Steam or hot water hazard. Before isolated and relieve the pressure. Work should The valve to actuator linkage nut located on the top of the valve spindle is preset and must not be adjusted. Cautions Do not apply any voltages until a qualified technician has checked the system and the commissioning procedures have been completed. If any equipment covers have to be removed during the installation of this equipment, ensure that they are refitted after installation to comply with UL and CE safety requirements. When the valve plug/spindle assemblies are changed after factory test or replaced in service, the original specified percentage let-by can no longer be guaranteed. Information is given for guidance only and TAC Satchwell do not accept responsibility for the section or installation of its products unless information has been given by the Company in writing relating to a specific application. Design and performance of TAC Satchwell equipment is subject to improvement and therefore liable to alteration without notice. A periodic system and tuning check of the control system is recommended. Please contact your local sales office for details. Observe recommendations under Good Design Practise - see Page 3. Observe limits of water temperature, system pressure and maximum differential pressure - see Page 2. The system should be thoroughly flushed out to remove foreign matter before fitting the valve. Interference with those parts under sealed covers renders the guarantee void. On October 1st, 2009, TAC became the Buildings Business of its parent company Schneider Electric. This document reflects the visual identity of Schneider Electric, however there remains references to TAC as a corporate brand in the body copy. As each document is updated, the body copy will be changed to reflect appropriate corporate brand changes. All brand names, trademarks and registered trademarks are the property of their respective owners.