user leaflet GAUGING TRANSDUCERS

Similar documents
User s Guide. GP911 Series Analog Gaging Transducers. GP911 Series M /14 Page 1 of 12

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Instruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

GILMONT ACCUCAL FLOWMETERS

High-performance submersible pressure transmitter For level measurement Model LH-10

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

Advanced Fluid Handling Cart Owner s Manual

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

High-performance submersible pressure transmitter For level measurement Model LH-10

INSTALLATION AND OPERATING INSTRUCTIONS

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

Right-Angle Tube Roller Model

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

IMPORTANT SAFETY INSTRUCTIONS

200 PSI COMPRESSORS - MODEL NUMBERS

100C Air Compressor Kit

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Teledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax)

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

MAINTANCE MANUAL CNC ROTARY TABLE MODEL: DMNC-5C YUASA INTERNATIONAL.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

F13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

Electropneumatic Transducer (I/P) Installation, Operation and

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

High flow rate. Cost effective. Compliant. Gripper with GSW-B Shaft Interface and Compensation Unit

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

Installation, operating and maintenance Instructions for Seemag bypass level indicator

WIKA INSTRUMENT CORPORATION

Model PDT Dewpoint Transmitter

1 DRIVE INDUSTRIAL IMPACT WRENCH

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

FLEXIBLE SHAFTING (Wet & Dry)

Assembling and testing fluid power systems

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Engineering Data Sheet

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

The Ins and Outs of I/P Transducers

CP10 Sensor Installation and Maintenance Instructions

PAPR Flow Tester. instructions. part no WARNING

MF2M Monnier Miniature Compressed Air Filter

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

AIR COMPRESSOR MANUAL INSTALLATION, OPERATION AND MAINTENANCE GUIDE

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

602 STRINGING MACHINE OWNER'S MANUAL

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Gripping rotary modules

Operating manual for the pressure transducer unit CCS 1000

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Budget Range Operators Handbook

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

Specifications Testing & Adjusting Disassembly & Assembly

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Series 203 Granville-Phillips Variable Leak Valve

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

INSTRUCTION MANUAL LOW PRESSURE CALIBRATION PUMP MODEL PGL

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

MASTER TRUING STAND TS-3. Optional Dial indicator set with brackets Dial indicator bracket set only

HTHP Viscometer. Features DRILLING FLUIDS EQUIPMENT

INSTRUMENT MANUAL VP50 PROPORTIONAL CONTROL VALVE

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

SUPER PRECISION AIR RELAYS

OWNER'S MANUAL. Copyright 1999 ATS - All Rights Reserved

Metham Aviation Design Limited, Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0)

Paddle Bar Replacement

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

444C DUAL PERFORMANCE VALUE PACK

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

REV0709. Parts List. Hydraulic Cylinder Model MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER. Max. Capacity: 55.2 Tons at 10,000 PSI

MoveRoll Conveyor Operating and Maintenance Manual

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

PRESSURE DIFFERENTIAL PRODUCTS 2008 TRICO CORPORATION. ALL RIGHTS RESERVED.

4 ANGLE GRINDER MODEL NO: CAT 52 PART

Model 130M Pneumatic Controller

SETTING UP THE MODEL 210B SRA

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Model Series 62 Constant Differential Relay

400C & 450C DUAL PERFORMANCE VALUE PACKS

2-JAW SELF-CENTERING PARALLEL PNEUMATIC GRIPPER (SERIES HS)

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

O P E R ATING INSTRUCTIONS FOR MODEL SPR-45 Automatic Screen and Stencil Printer

Threaded Closures Installation, Operation & Maintenance

MANUAL BE SERIES Test Benches

Transcription:

user leaflet

Solartron Metrology Gauging Transducers are high precision measurement probes intended for all gauging applications demanding high accuracy and a high degree of repeatability. The one piece parallel body houses a precision linear ball sleeve bearing assembly, anti-rotation guide and the choice of either a half bridge or a L.V.D.T. winding, a combination which adds up to an extremely versatile, accurate and cost effective measurement solution. Installation Recommendations Location & Clamping L.V.D.T. gauging transducers generally are a reliable and proven technology that is well established in all areas of manufacturing and quality control. The majority of the associated problems experienced with their application and use are totally avoidable, particularly if sufficient thought is given during the initial design stages of equipment, to the position and clamping methods employed for these measuring elements. L.V.D.T. s being of inductive nature are susceptible to some degree to the influence of magnetic fields and therefore should be positioned well away from electric motors, relays and permanent magnets, where this is not possible then magnetic shielding should be considered as an alternative. Clamping of the probe body should be carefully considered, ideally the body of the transducer should be clamped in a pinch or yoke type clamp, if this is not possible then the introduction of a load spreading bush between body and clamp is a preferred alternative. Irrespective of clamping method care must be taken not to overtighten retaining screws as distortion of the body may prove damaging to the integrity of the transducer and adversely affect the geometry of the installation. 2

Where single point screw clamping is adopted then the tightening torque employed should be limited to that which will give a maximum of 50 Kg point load. The typical maximum torque for an M5 x 0.8 mm or a 10-32 UNF screw would be approximately 0.27 Nm. Tip Tightness Standard measuring tips are factory tightened to a torque of between 0.18 Nm and 0.22 Nm, this is sufficient to prevent loosening of the tip in use, but well within the damage threshold of the anti-rotation mechanism. It is recommended that replacement tips are tightened to the prescribed torque limits with the shaft fully retracted. A proprietary thread locking anaerobic sealant may be used sparingly if desired. Zero Adjustment This is best achieved by first positioning the gauge master, zeroing any electrical offset control, selecting the coarsest gain and moving the gauging probe into contact with the master until the reading comes onto the scale. Gently tighten the clamp until it is just possible to fidget the probe manually towards the zero indication. As zero is approached, the instrument gain may be increased; when the zero point is within the range of the zero offset controls the clamp must be fully tightened. Any standard Solartron probe used over the whole of its rated stroke should be mechanically set to within 0.10 mm of true zero, if the measuring range is less than the rated stroke then the setting tolerance may be increased proportionally to within the limits of the available electrical offset. 3

Cable The transducer cable is specially manufactured to Company specification to achieve the optimum balance between flex life, flexibility, chemical resistance, abrasion resistance and electrical characteristics such as electrostatic screening. The following precautions will minimise transducer failure due to cable damage. Cable runs should be positioned well clear of moving components and vulnerable working areas. If the cable is in a flex situation then a minimum bend radius of 150 mm should be maintained, the vacuum and pneumatic options should not be flexed from the transducer cable entry, but should be anchored separately at a position of 50-75 mm from the end cap. All non-pneumatic probes with the exception of the AX/0.5/S and A6G, are provided with a cable strain relief spring as standard (the AX/0.5/S and A6G may be provided with strain relief as a standard option). This feature allows the user to retrospectively install a right angle cable outlet to aid space or cable routing restrictions. 4

Pneumatic Option (AX//P & AT//P Series) The gauging tip of pneumatic probes is normally biased in the inward direction and extension of the tip is achieved by applying air pressure to the probe nozzle. Air pressure may be varied within the specified limits to achieve the desired tip force at zero. To maximise the working life of the probes the air supply should be both clean and dry; i.e. filtered to better than 5 microns and with a relative humidity of less than 60 %. Dimensions mm AX//P - The pneumatic probes are designed to be leak free and of small volume to minimise the air flow requirements and maintain a consistent tip force. Care must be taken not to damage the bellows seal, as the satisfactory operation of the probe is entirely dependent on this component. A working clearance around the bellows equivalent to a 9.5 mm dia. hole is desirable. Operating Pressure Range for Standard AX//P Products : 0.4 Bar (5.8 psi) to 1.0 Bar (14.5 psi) 30 8.0 Φ 8.5 5

AT//P - AT//P series pneumatic probes are designed to operate pneumatically without the need for a rubber gaiter, the benefits derived over the AX//P series are a greater range of air pressure, and hence tip force, and are less susceptible to failure due to mechanical damage. The features that must be considered when applying AT//P probes is that air loss through the probe can by specification, be up to 150 ml/min; and the exposed portion of the probe shaft cannot be allowed to become contaminated by viscous substance. Operating Pressure Range for Standard AT//P Products: 0.3 Bar (4.4 psi) to 2.0 Bar (29 psi). Vacuum Option (AX//V Series) The gauging tip of the vacuum operated probes is normally biased in the outward direction and retracted by the application of negative pressure within the specified ranges at the probe nozzle. Care must be taken not to damage the bellows' seal, as the satisfactory operation of the probe is entirely dependent on this component. Probes may be operated from a pumped system or individually from a hand operated bulb. Operating Pressure for Standard Products : 0.27 Bar (4 psi) maximum 6

Adjustable Pretravel Option (AX//S & AT//S Series) The option for adjustable pretravel is provided to maximise probe life and minimise component damage where side application of the gauged component is necessary. Pretravel should be adjusted for minimum lift of the probe tip necessary for a satisfactory gauging operation within the tolerance of the gauged component. Pretravel should only be adjusted using the spanner provided. The pretravel adjustment is not provided as a means of fine mechanical zero control, although it is possible to be used as such, excessive use of the facility for zero adjustment can result in loss of electrical datum, resulting in possible damage to the internal stops. Environmental Considerations All non-pneumatic gauging probes are specified to operate from -10 C to +80 C and all pneumatic probes from +5 C to +80 C, at the low temperature extremes it may be necessary, due to stiffening, to remove the rubber gaiter to achieve satisfactory operation, in this case the atmosphere must be both clean and dry. However, continued operation without the gaiter is not recommended due to the damage caused by the ingress of dirt. Use of the transducer without the gaiter invalidates warranty. Solartron Metrology probes are designed to withstand the rigors of in-process gauging and will operate satisfactorily in the presence of copious amounts of coolants and cleaning solvents. 7

Quadrature Resistor These are supplied, where necessary, to minimise residual voltage at null and should be fitted as follows:- L.V.D.T. : Between yellow and white or yellow and green depending on phase (see calibration sheet for details).yellow wire is not connected in optional factory fitted plugs. Half-Bridge : Between yellow and red or yellow and blue (see calibration sheet for details). Electrical Connections for Standard Solartron Probes Connector : Lumberg 5 pin 240 DIN 8 Part No. 501382 issue 13.1

Electrostatic Screen The black wire link is provided as an optional ground connection to the body of the probe and can prove beneficial when connected to the instrument ground in providing electrostatic screening, particularly in hand held single point fixture applications. LVDT + BLACK (optional link) CABLE SCREEN BLUE WHITE YELLOW 4 5 3 2 1 Plug View into Pins Care must be taken in multi-point fixturing that multiple ground loops are not introduced and also that the black wire is not the sole ground connection for fixtures incorporating any mains operated components. - Case Half + Bridge GREEN RED BLACK (optional link) CABLE SCREEN BLUE YELLOW 4 3 2 Plug View into Pins Case - RED 5 1 9

W-Series Application Notes When applying these probes the following pertinent points need to be observed in order to maintain the specification and to maintain continued reliable operation: 1) Air supply must be clean and dry, ie. Max 60% RH and filtered to particle size of 0.1 mm. 2) The operating environment must be clean and dry. Viscous materials contaminating the probe shaft can inhibit operation and/or negate the properties of the low viscosity synthetic lubricating oils employed. 3) Replacing a contact tip should be approached with caution, the bearing assembly by default is delicate and any undue force can potentially damage the unit resulting in loss of free movement. Maximum tightening torque is 12 15 cnm. It is advised that Solartron replace or fit custom tips, this ensures that the probe after testing will operate to specification, also if the mass of the tip differs from standard then any variance to the specification can be advised. 4) It is not recommended that the W-Series probes are subjected to side loading, as this can considerably shorten the useful working life. 10