Assembly Instructions and User Manual MP3-P Therapy Beam Analyzer L981403

Similar documents
User Manual PTW-DensiX. D / Di/Zi

User Manual MP3-S Therapy Beam Analyzer

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00

Med Aire Alternating Pressure Pump and Pad System

User Manual. RW3 Slab Phantom T29672 and T

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Operating Instructions

Type BBS-03, BBS-05, BBS-06, BBS-25

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

Digital Melting Point Apparatus

30T A/Manual Hydraulic Shop Press

Proton Therapy QA Tools

Instruction Manual for Configura Cushionair Portable Pump

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

User Instructions 1789 Parapet Wall Anchor

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

FPD20 Series. Gear wheel flow sensor

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

Oxygen Dialflow Meter. Instructions for Use

Hydraulic Punch Drivers

BMR 2100XL Operating Instructions Page 1 of 13

Manual Actuated Boiler Blowdown Valves

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Instruction Manual BA90 Precision Barometer

Universal Gage. Multimar 844 T

Translation of the original Operating Instructions for HKS rubber compensators

Vapotherm Q50 Compressor. Instructions for Use

ATS430 turbidity sensor Retractable insertion assembly

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

MoveRoll Conveyor Operating and Maintenance Manual

User Manual. Quantos Automated Dosing Liquid Module

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

Fiber Optic Cable Installation 3 in 1 SLIDE, BLOW, LUBRICATE

INSTRUCTION MANUAL CZ 630/631

Use this key to determine which sections of this Product Manual apply to your job.

! Warning, refer to accompanying documents.

Operating and maintenance manual Filter and reducing station Series / 1.0

Operating Instructions. ATMOS Chair Comfort. English GA1GB Index 01

INSTALLATION GUIDE Gas Rangetops

INSTRUCTION MANUAL Pressure Relief Device LPT

DK46 - DK800 Supplementary instructions

Instrument Operating Manual

Operating Instructions

Pressure Automated Calibration Equipment

CP10 Sensor Installation and Maintenance Instructions

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Instruction Manual Contact Pressure Vacuum Gauge

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

CS150 CAP STAPLER OWNER S MANUAL

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

INSTRUCTION MANUAL. Slavia 630/631

Air Plus User Manual

Micro Dial-Flowmeter. Instructions for Use

Safety instructions and operating manual

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

Pressure Injection Cell Operator s Manual

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

CFSW. Hinges with built-in safety multiple switch

User manual. ZX trolley.

GM Series Dual-Block Multi-Function Gas Control Valves

INSTRUCTION MANUAL. Gas Salamander

User Instruction Manual Fixed Beam Anchor

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

Overspeed governors (113 OG Моment 250 MR, 114 OG Moment 250 A3, 115 OG Moment 250 MRL, 119 OG Moment 250 MRL/1)

Squeegee Unit for MRS Multi-Recovery System

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

VERTICAL AIR COMPRESSORS

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

PH01 Perfusion Cannula Manual

OC Panel High Limit Aquastat Kit, Manual Reset p/n

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

Oxygen Dialflow Meter. Instructions for Use

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions

User Instruction Manual For Davit Rescue System

Installation and Use Manual

GM-121: Container End Lock Anchor Wand Page 1 WINSAFE CORP. GM 121 CONTAINER END LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Arbor Terminator Press Operation Manual For IDT Connectors Order No Engineering No: AM

Instruction Manual EMA 84 Digital Pressure Gauge

LRS(H)4 Pressure-Reducing Regulator User Manual

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

UsER manual for Watersens ph -REDOX

F13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS

USER MANUAL

35 TON HYDRAULIC PUNCH WARNING

USER MANUAL LTH-255A Hand Piece

Z5160 Load adapter Mounting instructions (1.2 EN)

AutoChanger Installation & User Guide Issue 2

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Transcription:

Assembly Instructions and User Manual MP3-P Therapy Beam Analyzer L981403 Version 0 or higher Contents Operating Manual Technical Manual Service Manual D850.131.03/01 en 2016-05 Bru

General Information General Information The product bears the CE-mark "CE-0124" in accordance with the Council Directive 93/42/EEC about Medical Devices and fulfills the essential requirements of Annex I of this directive. The product is a class IIb device (MDD). Electrical Safety The product fully complies with the requirements of the standard IEC 61010-1. Electromagnetic Immunity The product fully complies with the requirements of the following standards: IEC 61326-1 CISPR11/EN 55011 class B The user manual is an integral part of the product. It should always be kept near the product. Observance of the manual is a prerequisite for proper product performance and correct operation. Operator safety, specified measuring accuracy, and interference-free operation can only be guaranteed if original products and parts are used. Furthermore, only the accessories listed in this manual are approved by PTW-Freiburg and only they or other accessories whose use has been expressly permitted by PTW- Freiburg may be used in conjunction with the product. Safe operation and proper product performance are not guaranteed if accessories or consumables from other manufacturers are used. PTW-Freiburg cannot be held liable for damage resulting from the use of accessories or consumables from other manufacturers or when the user ignores the instructions and information given in this manual. PTW-Freiburg only considers itself responsible for the safety, reliability, and performance of the product if the assembly, extension, readjustment, modification, or repair is carried out by PTW-Freiburg or by persons authorized by PTW-Freiburg, and if the product is used in compliance with the technical documentation. In case of any questions concerning the service, support, or warranty, please contact your supplier. This manual is in conformity with the product specifications and all applicable safety standards that are valid as at the printing date. All rights are reserved for devices, circuits, techniques, software, and names as referred to in the manual. PTW-Freiburg reserves the right to make modifications. Please contact PTW or your local representative for the most current information concerning the products of interest. No part of the technical documentation may be reproduced without written permission from PTW-Freiburg. PTW-Freiburg is a registered manufacturer according to the ElektroG (Elektro- und Elektronikgeräte-Gesetz). Elektro-Altgeräte-Register (EAR) Registration number DE15599992 PTW-Freiburg works in strict accordance with a quality management system that is continuously updated according to the national and international standards. The warranty period is 1 (one) year and begins on the day of delivery. It is unaffected by repairs covered by the warranty regulations. 2 D850.131.03/01 en

General Information PTW-FREIBURG Physikalisch-Technische Werkstätten Dr. Pychlau GmbH Lörracher Str. 7 79115 FREIBURG GERMANY Phone: +49 761 49055-0 Fax: +49 761 49055-70 info@ptw.de www.ptw.de D850.131.03/01 en 3

Contents Contents General Information 2 Contents 4 Illustrations 6 Intended Use 7 Safety Information 8 Operating Manual 13 1 The Components of the MP3-P System 13 1.1 Perspex Tank 14 1.2 Moving Mechanism 15 1.3 Positioning Device 16 1.4 SCANLIFT Carriage and Reservoir 17 1.5 Control Unit and Control Pendant 17 2 Assembly of the System 18 2.1 Assembling SCANLIFT, Positioning Device, and Perspex Tank 18 2.2 Assembling of the Junction Box and the Moving Mechanism 20 3 Installation of the System for Measurement 24 3.1 Quickstart (Workflow) 24 3.2 Mounting Detectors on the Moving Mechanism 25 3.3 Connecting the Detectors 27 3.4 Mounting and Connecting the Reference Detector 28 3.5 Mounting the Inhomogeneous Phantom T43031 31 3.6 Mounting the Hemisphere T41029.3.231 31 3.7 Mounting the Wedge T41029.1.220 32 3.8 Mounting the Film Holding Device T40040 32 3.9 Connecting SCANLIFT 34 3.10 Filling with Water 35 3.11 Connecting the Control Unit and Control Pendant 37 4 Installation Check 38 5 Error Messages and Troubleshooting 39 4 D850.131.03/01 en

Contents Technical Manual 41 6 Technical Specifications 41 7 Order Information 43 Service Manual 45 8 Cleaning 45 8.1 General Information on Cleaning 45 8.2 Device Surfaces 46 8.3 Connection Cables 46 8.4 Connectors 46 8.5 Perspex Tank 46 8.6 Moving Mechanism 46 9 Preventive Maintenance 47 10 Storage 48 11 Disposal of the Product 48 Literature 49 Appendix: China Electronic Industry Standard Compliance 50 Index 52 D850.131.03/01 en 5

Illustrations Illustrations Figure 1: Definition of patient environment 12 Figure 2: MP3-P System with accessories for measurements with a measuring and a reference detector 13 Figure 3: MP3-M Perspex tank with junction box and moving mechanism (top: front view; below: rear view) 14 Figure 4: Connections at the junction box 15 Figure 5: Positioning device for tank alignment 16 Figure 6: Assembling SCANLIFT, positioning device, and Perspex tank 19 Figure 7: Mounting the A-axis 21 Figure 8: Mounting the B-axis 22 Figure 9: Mounting the C-axis 23 Figure 10: Horizontal mounting of the Bragg Peak chamber 25 Figure 11: Vertical mounting of the Bragg Peak chamber 26 Figure 12: Mounting the reference detector 28 Figure 13: Mounting the reference detector holder 29 Figure 14: Mounting the inhomogeneous phantom T43031 31 Figure 15: Mounting the hemisphere T41029.3.231 31 Figure 16: Mounting the wedge T41029.1.220 32 Figure 17: Mounting the film holding device T40040 33 Figure 18: Coupling of the plastic hose of the water reservoir 34 6 D850.131.03/01 en

Intended Use Intended Use The MP3-P Therapy Beam Analyzer system T41029 is a computer-controlled measuring system for recording dose distributions (depth dose curves and profiles) in order to check the emitted irradiation of particle accelerators (such as a cyclotron or synchrotron). For filling or emptying the MP3-P Therapy Beam Analyzers the SCANLIFT carriage and reservoir is used. The basic system consists of the following components: Perspex tank T41029.1.500 with moving mechanism and locking coupling NOTE Please observe the information given in the user manuals supplied with the SCANLIFT carriage and reservoir, the dual channel electrometer TANDEM XDR, the TBA CONTROL UNIT, the TBA CONTROL PENDANT, the PC and the ionization chambers. NOTE The corresponding software is the only means for running and analyzing measurements. Follow the instructions given in the corresponding user manual. TBA CONTROL UNIT T41013 TBA CONTROL PENDANT T41031 SCANLIFT carriage and reservoir T41024 MP3-S positioning device T41002.1.016 Dual channel electrometer TANDEM XDR T10037 Bragg Peak chamber Type 34070 Thin-window Bragg Peak chamber Type 34080 The basic system can be expanded with additional accessories (see section 7, Order Information). D850.131.03/01 en 7

Safety Information Safety Information This is the safety alert symbol. It is used to alert the user to potential hazards. Obey all safety messages that follow this symbol to avoid possible bodily injury or equipment damage. All safety messages consist of the following components: Safety alert symbol and signal word Type of danger Source of danger Consequence Measures to prevent hazard Signal Words DANGER Indicates an imminent hazard. If not avoided, the hazard will result in death or serious injury. WARNING Indicates a hazard. If not avoided, the hazard can result in death or serious injury. CAUTION Indicates a potential hazard. If not avoided, the hazard could result in minor injury or product / property damage. Safety Information DANGER Operation in areas where an explosion hazard may occur or in oxygen-enriched atmospheres Explosion Hazard! The product is not suitable for operation in areas of risk where an explosion hazard may occur. Explosion hazards may be caused by the use of combustible anaesthetics, skin-cleansing agents and disinfectants. Furthermore the product is not suitable for application in oxygen-enriched atmospheres. The atmosphere is considered to be oxygen-enriched when more than 25 % of oxygen or nitrous oxide is added to the ambient air. WARNING Improper handling. Patient Hazard! The product is a medical electrical device and must only be handled by persons who are trained in the use of such equipment and are capable of applying it properly. The operator must be trained in the use of the device. NOTE Provides useful information to assure that you get the most from your equipment. 8 D850.131.03/01 en

Safety Information WARNING Electricity is a source of risk, particularly when the product is not in perfect operating condition or when it is operated inappropriately. Shock Hazard! Strictly observe the following warnings. Failure to do so may endanger the lives of the patient, the user and other persons involved. Before using the product, the user must ascertain that it is in correct working order and operating condition. Before putting the device into operation, visually inspect all connection cables for signs of damage. Damaged cables and connectors must be replaced immediately. When disconnecting the device from the power line, first remove the plug from the wall outlet, then disconnect the power cord from the device. Devices on which moisture condensation has developed as a result of temperature changes must not be switched on unless completely dry. Liquids must not enter the product. If liquids have entered the product, it must be thoroughly inspected before being used again. The devices are IEC 61140 protection class I equipment. They may be put into operation only when connected to a properly installed power outlet with earthing contact. All devices of a system must be connected to the same electric circuit. Devices which are not connected to the same circuit must be electrically isolated (use RS232 interface with galvanic insulation). WARNING Exclusion of operation in the patient environment: Neither the product nor any peripheral devices may be operated in the patient environment (see Figure 1). Exclusion of operation as device with patient contact: The device is not intended for use in direct contact with the patient. Neither the device nor any peripheral device may have contact to the patient. Never touch the patient and open connectors of the device at the same time. Exclusion of operation as controlling instrument: The device is only designed for use as a measuring device. The device must not be used to control radiodiagnostic equipment or radiotherapy units. Use of peripheral devices: Peripheral devices (PC, printer) may only be connected if they meet the requirements of standard UL 60950-1 or IEC 60950-1 or of standard IEC 61010-1. Devices may be connected to other devices or to parts of systems only if it has been ascertained that this connection does not impair the safety of the patient, the operator or the environment. If the device specifications do not contain information as to connecting the device to other equipment, you must consult the manufacturer of the other equipment or an expert about the effects of the connection on the patient, the operator or the environment. Always observe standard IEC 61010-1. D850.131.03/01 en 9

Safety Information WARNING Operation in conjunction with particle beams that activate the material of the product. Risk to Persons! Certain types and energies of particle beams may activate the material of the product. In these situations it must be ascertained that there are no persons in the vicinity of the product until the radiation of the activated material has decayed. WARNING Hazards originating from other system components. Patient Hazard! Equipment Damage! Observe the safety information provided in the user manuals of the system components. WARNING Magnetic and electrical fields are capable of interfering with the proper performance of the device. Equipment Failure! For this reason make sure that all external devices operated in the vicinity of the product comply with the relevant EMC requirements. X-ray equipment, MRI devices, radio systems, cell phones, etc. are possible sources of interference as they may emit higher levels of electromagnetic radiation. Keep the product away from these devices and verify its performance before use. 10 D850.131.03/01 en

Safety Information CAUTION Use of the product without observing the user manual. Bodily Injury! Equipment Damage! Always use the product in compliance with the user manual. Otherwise, the intended protection can be reduced. Use the product only in conjunction with the products approved for this purpose by PTW and/or the products listed in the section "Intended Use". Handle the product with care to avoid equipment damage. CAUTION Operation under inadequate ambient conditions. Equipment Damage! Before connecting the device to the power line, make sure that line voltage and frequency are equivalent to the ratings indicated on the nameplate of the device. Set up the device in a location which affords sufficient ventilation. The air gaps of the device must not be obstructed. Always observe the ambient conditions as indicated in the "Technical Specifications". CAUTION Operation in conjunction with particle beams. Equipment Damage! Continuous irradiation with a pencil beam through the entrance window at a fixed position can cause a local discoloring of the material. If such a discoloring appears, the position of the beam traversing the entrance window should be shifted (e.g., laterally by 15 mm). Continued irradiation through the original position can lead to radiation damage of the entrance window material. Cracks can occur. CAUTION Improper handling of cables and connectors. Equipment Damage! To avoid damage to the cables and connectors, observe the following points. Do not kink the cables. Observe the minimum bend radius of the cables. Never exert pressure on the cables. Do not step on the cables. Do not roll trolleys over the cables. Do not pull or twist the cables. Disconnect the cables from the devices during transport and when the devices are not in use. Do not let the cables hang down unrestrained. The connectors must always be clean. Do not allow the connectors to lie on the floor. Always protect connectors when pulling them through cable conduits. D850.131.03/01 en 11

Safety Information NOTE Set up the device so that the operator has a clear, unobstructed view of the control panel. NOTE Do not position the device so that it is difficult to operate the disconnecting device. Symbols on Product and Nameplate Symbol Description Please refer to the user manual! The product bears the CE-mark. Manufacturer and date of manufacture Reference number Serial number Separate collection of electrical and electronic equipment! (refer also to the section "Disposal of the Product") Labeling according to "Administration on the Control of the Pollution caused by Electronic Information Products (ACPEIP)" (China RoHS) (refer also to the Appendix) Figure 1: Definition of patient environment 12 D850.131.03/01 en

Operating Manual The Components of the MP3-P System Operating Manual 1 The Components of the MP3-P System Figure 2: MP3-P System with accessories for measurements with a measuring and a reference detector D850.131.03/01 en 13

Operating Manual The Components of the MP3-P System 1.1 Perspex Tank The moving mechanism as well as several ancillary devices (refer to section 2) are attached to the Perspex tank. The tank (Figure 3) is filled with water. The water level should remain approx. 20 mm below the top edge of the tank. Horizontal and vertical lines on the tank allow it to be easily leveled. As an alternative, you can use the circular bubble level that is part of the MP3-P accessories. Additional marks at the bottom and on the walls of the tank allow it to be aligned, using the accelerator laser system. The Perspex plates are glued together. On the inside of the tank, a special sealing agent protects the glue from penetrating water. Figure 3: MP3-M Perspex tank with junction box and moving mechanism (top: front view; below: rear view) 14 D850.131.03/01 en

Operating Manual The Components of the MP3-P System 1.2 Moving Mechanism 1 2 3 4 5 6 7 CAUTION Improper handling. Risk of injury! Do not reach into the Perspex tank while the moving mechanism is working. Pay attention that hairs or cloths of the user and other persons involved do not touch the rotating spindle. The moving mechanism is made of stainless steel and is permanently installed on the tank. It consists of three arms with the following designations: A = horizontal arm, fixed, B = moving vertical arm and C = moving horizontal arm with slider. Figure 4: 8 Connections at the junction box The moving mechanism is suitable for both horizontal and vertical radiation. Holding devices for detectors to move in the field are screwed to the slider of the C-arm. The slider and the arms are moved by stepper motors that permit a minimum step width of 0.1 mm. The reproducibility of the geometric positioning is also ± 0.1 mm. 1 without function 2 without function 3 Control cable to the control unit 4 Motor cable A 5 Motor cable B 6 Motor cable C 7 Motor cable to the control unit 8 Control pendant The moving range limits can be adjusted for each axis and stored in the control unit to ensure that the detector does not hit the Perspex walls. The components of the moving mechanism, particularly the guides and moving parts, are not adversely affected by water. Bending or contortion due to water absorption or corrosion are thus excluded. D850.131.03/01 en 15

Operating Manual The Components of the MP3-P System 1.3 Positioning Device The positioning device allows the Perspex tank to be aligned, using the laser system of the accelerator and the lines on the walls of the tank. The positioning device has three adjustable legs (8) that allow the height to be adjusted by ± 10 mm. Additionally, the three adjusting screws (5) allow the tank to be adjusted horizontally by ± 10 mm, or by approx. 1 on a vertical axis (micro-adjustment). A mechanism allows the tank to be rotated by 45 or 90 (refer to Figure 5 for center of rotation). Horizontal alignment of the tank is easy when it is filled to the horizontal lines and the water surface is used as a level. 1 2 3 4 5 6 7 8 Figure 5: Positioning device for tank alignment 1 Transportation lock 2 Center of rotation 3 Plate 4 Locking device 5 Adjusting screw (3 pieces) 6 Washer 6.4 (4 pieces) 7 Screw M6x16 (4 pieces) 8 Adjustable leg (3 pieces) 16 D850.131.03/01 en

Operating Manual The Components of the MP3-P System 1.4 SCANLIFT Carriage and Reservoir CAUTION Improper handling. Equipment damage! If you are pumping water, you must not remove the plastic hose between SCANLIFT and Perspex tank. The positioning device is screwed together with the Perspex tank to the triangle holder of SCANLIFT (refer also to section 2). For mounting and handling of SCANLIFT please refer to the user manual of SCANLIFT. 1.5 Control Unit and Control Pendant The MP3-P system is operated via the control unit and the control pendant. The control unit (TBA CONTROL UNIT ) is an interface that connects the MP3-P water phantom to the computer. It supplies the power for the stepper motors and controls the detector movement. The control pendant (TBA CONTROL PENDANT) can be connected either to the control unit or to the junction box (at the Perspex tank). The control pendant indicates the detector coordinates A, B and C and allows the detector to be moved at two different speeds (10 mm/s and 50 mm/s). Additionally, the limits for the detector movement, the null point in the central beam and the reference points can be determined via the control pendant. Please note that some of the control pendant functions are available only when it is directly connected to the junction box at the Perspex tank (refer to the user manual of the control unit and the control pendant). Therefore it is recommended to connect the control pendant to the junction box. D850.131.03/01 en 17

Operating Manual Assembly of the System 2 Assembly of the System NOTE You can use the supplied tools to assemble the system. Use only the supplied stainless steel screws to attach the different components (e.g. the arms of the moving mechanism). All components must be of the same connection system (M). 2.1 Assembling SCANLIFT, Positioning Device, and Perspex Tank refer to Figure 6 NOTE For the assembly please observe also the information given in the SCANLIFT user manual. Place the base plate (2) on the positioning device. Mount the base plate onto the positioning device from below using four M6x16 screws (3) and washers. Mount the two strips of the mounting kit (6) on the bottom of the Perspex tank using two M6x16 screws (7) and washers. Place the Perspex tank (1) on the base plate (2). Pay attention that the water connection of the Perspex tank and the water connection of the SCANLIFT are located on the same side. Otherwise, the movement areas declared in the technical specifications are not to be reached (limited to hose length). Mount the Perspex tank onto the base plate using six M6x22 (5) screws and washers. Put the SCANLIFT (12) into operation according to the instructions given in the SCANLIFT user manual. Place the positioning device (8) on the SCANLIFT triangle holder (9). Make sure that its feet are in the notches of the triangle holder. Mount the positioning device onto the triangle holder from below using three M6x16 screws (10) and washers. Remove the transportation locks (refer to Figure 5 (1)). 18 D850.131.03/01 en

Operating Manual Assembly of the System 1 4 5 6 2 7 8 3 9 10 11 12 Figure 6: Assembling SCANLIFT, positioning device, and Perspex tank 1 Perspex tank 2 Base plate 3 Screw M6x16 and washer (4 pieces) 4 Nipple for water connection at Perspex tank 5 Screw M6x22 and washer (6 pieces) 6 Strip of the mounting kit (2 pieces) 7 Screw M6x16 and washer (4 pieces) 8 Positioning device 9 Triangle holder of SCANLIFT 10 Screw M6x16 and washer (3 pieces) 11 Water hose of SCANLIFT 12 SCANLIFT carriage and reservoir D850.131.03/01 en 19

Operating Manual Assembly of the System 2.2 Assembling of the Junction Box and the Moving Mechanism refer to Figure 7 up to Figure 9 Mount the junction box (T41013.1.100) on the Perspex tank as shown in Figure 3, using M4x40 screws and washers. Place the A-axis (5) on the supports (3) to the right and left of the angle pieces (4) on the Perspex tank and secure the axis with a swivel washer and an M6x16 screw (1) at each end, as shown in Figure 7. Check that the two bevel gear wheels engage properly in the centering shoulder and adjust, if necessary, by turning the threaded control shaft of the C-axis. Mount the C-axis on the B-slider (6), using four M4x10 screws (9). Plug the three connectors of the motor cables A, B and C into the corresponding sockets at the junction box. Hook the B-axis (5) onto the conical bolt of the A-slide (3), at the same time guiding the supporting rolls (7) over the support profile (6) at the bottom of the Perspex tank, as shown in Figure 8. Mount the B-axis on the A-slider, using two M5x16 screws (2). Do not yet tighten the screws. Align the B-axis vertically. To do so, use one edge of guide rail B and the vertical crosshair line of the Perspex tank. Now tighten the two M5x16 screws (2). Remove the M3x12 screws (8) to loosen the cable holder at the top and back of the A-slider. Secure the two motor cables B/C (10) with the cable holders (9) and tighten the two M3x12 screws (Figure 8). Place the C-axis (4) on the B-slider (6), the centering shoulder (8) engaging in the centering bore (7) and the catch pin (1) in the groove (2) (Figure 9). 20 D850.131.03/01 en

Operating Manual Assembly of the System 1 2 3 5 4 6 Figure 7: Mounting the A-axis 1 Screw M6x16 (2 pieces) 2 Washer (2 pieces) 3 Support (2 pieces) 4 Angle 5 A-axis 6 Perspex tank D850.131.03/01 en 21

Operating Manual Assembly of the System 8 9 10 1 11 2 3 12 4 5 6 7 13 Figure 8: Mounting the B-axis 1 Gear box B 2 Screw M5x16 (2 pieces) 3 Conical bolt 4 Slider B 5 B-axis 6 Supporting profile 7 Supporting rolls 8 Screw M3x12 (2 pieces) 9 Cable holder (2 pieces) 10 Motor cable B/C 11 Slider A 12 A-axis 13 Crosshairs 22 D850.131.03/01 en

Operating Manual Assembly of the System 1 2 3 6 7 8 9 4 10 5 Figure 9: Mounting the C-axis 1 Catch pin 2 Groove 3 Slider C 4 Axis C 5 Threaded control shaft 6 Slider B 7 Centering bore 8 Centering shoulder 9 Screw M4x10 (4 pieces) 10 Axis B D850.131.03/01 en 23

Operating Manual Installation of the System for Measurement 3 Installation of the System for Measurement NOTE You can use the supplied tools to install the system. All components must be of the same connection system (M). 3.1 Quickstart (Workflow) Position SCANLIFT (with mounted positioning device and Perspex tank). Mount the measuring detector on the moving mechanism according to section 3.2. Connect the measuring detector according to section 3.3. Mount the reference detector and connect it according to section 3.4. Mount further measuring equipment: Inhomogeneous phantom T43031 according to section 3.5 Hemisphere T41029.3.231 according to section 3.6 Wedge T41029.1.220 according to section 3.7 Film holding device T40040 according to section 3.8 Align the Perspex tank by using the laser system of the accelerator. Connect SCANLIFT to the Perspex tank according to section 3.9 Fill the Perspex tank with distilled water (refer to section 3.10). Adjust the water level by means of the adjustable legs (by comparing the water line with the horizontal lines or by using the circular bubble level). Check the height setting again in this position and, if necessary, correct it by means of the adjusting screws. Connect all cables between TANDEM XDR, TBA CONTROL UNIT, TBA CONTROL PENDANT and PC (if required) according to section 3.11. Connect the following devices with the power cord to the power line: TBA CONTROL UNIT TANDEM XDR SCANLIFT CAUTION Inaccurate orientation of the measuring detector or detectors. Erroneous Measurement! Observe the effective points of measurement of the detectors specified in the respective user manual. Position the measuring detector by using the TBA CONTROL PENDANT and check or set the limits and zero point. 24 D850.131.03/01 en

Operating Manual Installation of the System for Measurement 3.2 Mounting Detectors on the Moving Mechanism 3.2.1 Bragg Peak Chamber Type 34073 and Bragg Peak Chamber Type 34070 CAUTION Improper use in water. Measuring error! With the Bragg Peak chamber Type 34073 the measuring volume can be reduced by 0.5 % from a water depth of 30 cm. CAUTION Confusion of the chambers. Improper use in water. Equipment damage! Use following holders for the Bragg Peak chambers: Bragg Peak chamber Type 34073 with holder T41029.1.200 and Bragg Peak chamber Type 34070 with holder T41029.1.250 Select chamber and holder. Observe the designation at type labels. Secure the holder on the C-slider with the two M4x10 screws. horizontal mounting refer to Figure 10 vertical mounting refer to Figure 11 Insert the Bragg Peak chamber as shown in Figure 10 or Figure 11 as far as it will go, and secure it with the two clamping screws. The Thin-Window Bragg Peak chamber Type 34080 is not watertight and may not be used in water. 1 2 3 4 5 6 Figure 10: Horizontal mounting of the Bragg Peak chamber 1 Bragg Peak chamber 2 Screw M4x10 (2 pieces) 3 Clamping screw (2 pieces) 6 C-slider 4 Holder 5 C-axis D850.131.03/01 en 25

Operating Manual Installation of the System for Measurement 4 5 6 1 2 3 Figure 11: Vertical mounting of the Bragg Peak chamber 1 Bragg Peak chamber 2 Holder 3 Clamping screw (2 pieces) 4 C-slider 5 C-axis 6 Screw M4x10 (2 pieces) 26 D850.131.03/01 en

Operating Manual Installation of the System for Measurement 3.3 Connecting the Detectors 3.3.1 Bragg Peak Chamber Type 34073 and Bragg Peak Chamber Type 34070 Attach the plug holder T4316/U161 to the Perspex tank. If required, connect the ionization chamber to the extension cable T2954/K3-6. Clamp the plug connection of detector cable and extension cable in the plug holder T4316/U161. Connect the detector cable or the extension cable to detector input labeled FIELD on the rear side of the TANDEM XDR. D850.131.03/01 en 27

Operating Manual Installation of the System for Measurement 3.4 Mounting and Connecting the Reference Detector The reference detector can be mounted in the following modes: Mounting at the center of the entrance window of the Perspex tank Mounting at another position using a standard reference detector holder As reference detector you can use the following chambers with the appropriate holders: Bragg Peak chamber Type 34073 with holder T41029.1.210, Bragg Peak chamber Type 34070 with holder T41029.1.260 and Thin-Window Bragg Peak chamber Type 34080 with holder T41029.1.260 3.4.1 Mounting the Reference Detector at the Center of the Entrance Window of the Perspex Tank Insert the reference detector into the holder as shown in Figure 12 as far as it will go. Make sure the side labeled "Focus" faces the radiation source. Observe the slot provided for the detector cable. Secure the reference detector using the two clamping screws. Mount the holder with the reference detector on the outside of the Perspex tank in front of the entrance window (Figure 13) using the four M6x16 screws. Connect the reference detector to detector input labeled REF on the rear side of the TANDEM XDR. If required, you can use an extension cable T2954/K3-6. 1 2 3 Figure 12: Mounting the reference detector 1 Holder for reference detector 2 Reference detector 3 Clamping screw (2 pieces) 28 D850.131.03/01 en

Operating Manual Installation of the System for Measurement 1 2 3 Figure 13: Mounting the reference detector holder 1 Screw M6x16 (4 pieces) 2 Holder with reference detector 3 Entrance window of the Perspex tank D850.131.03/01 en 29

Operating Manual Installation of the System for Measurement 3.4.2 Mounting the Reference Detector at another Position Using a Standard Reference Detector Holder CAUTION Improper handling. Erroneous Measurement! Ensure that the complete ionization volume of the reference chamber is positioned within the radiation field and does not collide with the moving mechanism. CAUTION Inaccurate orientation of the detector. Erroneous Measurement! Observe the direction of beam for the detector specified in its user manual. CAUTION Improper handling. Equipment damage! Lay and fix the detector cable in such a way that the cable gets irradiated as little as possible. When laying the detector cable, please make sure that enough cable will be available for all possible positions of the detector and that the cable cannot be squeezed. For use of chambers T31010 or T31013 as reference detector Slide the chamber into the guide tube such that the chamber protrudes at the front of the tube. Lock the chamber with the clamping device. Connect extension cable to the chamber and to the detector input REF on the rear of the TANDEM XDR. Secure the chamber connector with the clamping screw. For use of Bragg Peak chambers T34070 or T34080 as reference detector Mount the reference detector holder T4316/U561 to the upper edge of the Perspex tank wall. Secure the rod at the holder. Insert the chamber into the holder. Lock the chamber with the clamping screw. Connect the extension cable to the chamber and to the detector input REF on the rear of the TANDEM XDR. Secure the chamber connector with the clamping screw. NOTE This chamber type is only used for Proton beam or Particle beam. The chamber has to be positioned in the central beam. Mount the reference detector holder T4316/U171 to the upper edge of the Perspex tank wall. Secure the guide tube at the holder. 30 D850.131.03/01 en

Operating Manual Installation of the System for Measurement 3.5 Mounting the Inhomogeneous Phantom T43031 3.6 Mounting the Hemisphere T41029.3.231 1 2 3 1 2 3 4 5 Figure 14: Mounting the inhomogeneous phantom T43031 1 Screw M6x16 (4 pieces) 2 Inhomogeneous phantom T43031 with holder T41029.1.240 3 Perspex tank Mount the inhomogeneous phantom T43031 on the holder T41029.1.240 according to the inhomogeneous phantom user manual. Mount the holder with the inhomogeneous phantom (2) on the outside of the Perspex tank (3) in front of the entrance window using the four M6x16 screws (1). Figure 15: Mounting the hemisphere T41029.3.231 1 Screw M6x16 (4 pieces) 2 Holder T41029.1.230 3 Hemisphere T41029.3.231 4 Screw M6x12 (4 pieces) 5 Perspex tank Remove the hemisphere T41029.3.231 from the inhomogeneous phantom T43031 according to the inhomogeneous phantom user manual. Mount the hemisphere (3) on the holder T41029.1.230 (2) using the four M6x12 screws (4). Mount the holder (2) with the hemisphere (3) on the outside of the Perspex tank (5) in front of the entrance window using the four M6x16 screws (1). D850.131.03/01 en 31

Operating Manual Installation of the System for Measurement 3.7 Mounting the Wedge T41029.1.220 3.8 Mounting the Film Holding Device T40040 Unscrew the six M6x20 screws and remove the mounting angle (for vertical mounting) and the holder from the film holding device according to the film holding device user manual. You will need four M6x20 screws for mounting the film holding device on the Perspex tank. Mount the two strips T41029.1.271 (3) on the outside of the Perspex tank besides the entrance window (5) using the four M6x16 screws (4). Mount the film holding device T40040 (2) on the two strips T41029.1.271 (3) using the four M6x20 screws (1). 1 2 3 Figure 16: Mounting the wedge T41029.1.220 1 Screw M6x16 (4 pieces) 2 Wedge T41029.1.220 with holder 3 Perspex tank Mount the wedge T41029.1.220 with the holder (2) on the outside of the Perspex tank (3) in front of the entrance window using the four M6x16 screws (1). 32 D850.131.03/01 en

Operating Manual Installation of the System for Measurement 1 2 3 4 5 Figure 17: Mounting the film holding device T40040 1 Screw M6x20 (4 pieces) 2 Film holding device T40040 3 Strip T41029.1.271 (2 pieces) 4 Screw M6x16 (4 pieces) 5 Entrance window of the Perspex tank D850.131.03/01 en 33

Operating Manual Installation of the System for Measurement 3.9 Connecting SCANLIFT 3.9.1 Preparing SCANLIFT refer to Figure 18 Put the hose clip onto the open tubing end of the water hose on the top of the SCANLIFT. Plug the coupling into the hose. Move the hose clip on the hose near to the coupling. Secure the coupling on the hose by fastening the hose clip. 3.9.3 Disconnecting SCANLIFT from Perspex Tank CAUTION Improper handling. Equipment damage! If you are pumping water, you must not remove the plastic hose between SCANLIFT and Perspex tank. Remove the water hose from the Perspex tank. To do this, pull back the unlocking bush of the coupling and then remove the coupling (refer to Figure 18). 3.9.2 Connecting SCANLIFT to the Perspex Tank Fit the coupling of the open tubing end of SCANLIFT on the nipple of the Perspex tank (Figure 6). Make sure that the nipple fully snaps into the coupling. 1a 1 2 3 Figure 18: Coupling of the plastic hose of the water reservoir 1 Coupling a Unlocking bush 2 Hose clip 3 Water hose of SCANLIFT 34 D850.131.03/01 en

Operating Manual Installation of the System for Measurement 3.10 Filling with Water Please refer also to the instructions in the SCANLIFT user manual. 3.10.1 Initial Filling of the System CAUTION Improper handling. Equipment damage! Before you fill the Perspex tank, make sure that the water and the Perspex tank are at room temperature and the water hose is connected. NOTE Use only distilled water to fill the system. Add an anti-corrosion fluid recommended by PTW-Freiburg (PTW-Nr. L999010) to one filling. Follow the instructions of the manufacturer for the dosage of the anti-corrosion fluid. The anti-corrosion fluid has no effect on the absorption and scatter characteristics of highenergy radiation. PTW recommends the following procedure for initial filling of the system: Fill the Perspex tank up to the top horizontal mark with distilled water from a canister or a supply line. Then let the water flow into the SCANLIFT water reservoir: To start the emptying process briefly press once the WATER key on the SCANLIFT control pendant. To stop the emptying process press the STOP key. 3.10.2 Pumping Process CAUTION Improper handling. Equipment damage! Damage to building! Watch all pumping processes so that you can switch off the pump as soon as the Perspex tank has been completely filled or drained. When filling the Perspex tank the default setting for pumping at SCANLIFT of 4 minutes is too long and the Perspex tank would run over. Thus filling has to be done imperatively under visual inspection and the pump has to be stopped in time by pressing the STOP key. CAUTION Improper handling. Equipment damage! Make sure that the SCANLIFT pump never runs dry. If the pump runs dry, stop it immediately. Add additional water to the SCANLIFT water reservoir if necessary. PTW recommends filling additional water into the Perspex tank up to the maximum filling level in order to avoid bubbles and turbulences. D850.131.03/01 en 35

Operating Manual Installation of the System for Measurement Pumping from SCANLIFT Water Reservoir into the Perspex Tank To start the pumping process from SCANLIFT water reservoir into the Perspex tank briefly press once the WATER key on the SCANLIFT control pendant. To stop the pumping process press the STOP key. Pumping from the Perspex Tank into SCANLIFT Water Reservoir To start the pumping process from the Perspex Tank into SCANLIFT Water Reservoir briefly press once the WATER key on the SCANLIFT control pendant. To stop the pumping process press the STOP key. 3.10.3 Draining the System CAUTION Improper handling. Equipment damage! The inclination required to completely drain the Perspex tank can be attained by adjusting one of the leg levelers of the positioning device accordingly. Do not tilt the tank manually. First empty the Perspex tank by draining the water from the Perspex tank into the SCANLIFT water reservoir. To start the emptying process briefly press once the WATER key on the SCANLIFT control pendant. To stop the emptying process press the STOP key. Move the SCANLIFT to a suitable drain and use the screw plug underneath the SCANLIFT to drain the water. CAUTION Improper handling. Equipment damage! After use, the Perspex tank should be drained to prevent deformation of the walls and undue stress on the seams. The Perspex tank may only be filled with water continuously for 12 hours maximum in order to avoid a damage of the Perspex tank due to the hygroscopic character of PMMA. The Perspex tank should not be filled again for further 12 hours. This allows the water that was incorporated in the PMMA to emit. 36 D850.131.03/01 en

Operating Manual Installation of the System for Measurement 3.11 Connecting the Control Unit and Control Pendant CAUTION Direct or scattered radiation Equipment Damage! Do not expose the TANDEM XDR, the TBA CONTROL UNIT, and the TBA CONTROL PENDANT to direct radiation. The devices should be installed in the treatment room only for the duration of the measurement. Do not leave them in the treatment room for prolonged periods of time to prevent damage due to scattered radiation. CAUTION Direct or scattered radiation. Erroneous Measurement! In order to avoid influence of the radiation on the measurement, position the TANDEM XDR, the TBA CONTROL UNIT, and the TBA CONTROL PENDANT as far from the radiation as possible. Follow these steps to connect the TBA CONTROL UNIT: Front Panel CONTROL PENDANT socket: connection for TBA CONTROL PENDANT NOTE It is also possible to connect the TBA CONTROL PENDANT at the junction box of the Perspex tank (socket on the underside of the junction box). Please note that some of the control pendant functions are available only when it is directly connected to the junction box at the Perspex tank (refer to the user manual of the control unit and the control pendant). Therefore it is recommended to connect the control pendant to the junction box. Rear Panel DOSEMETER socket: connection of TANDEM XDR via signal cable T10006.1.002 Power supply: connection for power cord RS232 socket: connection of TBA CONTROL UNIT to PC via interface cable (T22373/K67) MOVING MECHANISM sockets: connection of control cable (T43164/K1) and motor cable (T43164/K2) to junction box (T41013.1.100) of Perspex tank D850.131.03/01 en 37

Operating Manual Installation Check 4 Installation Check Before starting the MP3-P system, please check the following points carefully: Are the connectors of the control cable (T43164/K1) and of the motor cable (T43164/K2) between TBA CONTROL UNIT and junction box (T41013.1.100) at the Perspex tank properly connected on both sides? When the devices, e.g. TANDEM XDR or TBA CONTROL UNIT, have been connected or switched on, you will get the following indications: Power LED at the TANDEM XDR is illuminated. Power LED at the TBA CONTROL UNIT is illuminated. Are the motor cables of the moving mechanism connected to the correct sockets at the junction box? Is the interface cable (T22373/K67) between TBA CONTROL UNIT and PC connected on both sides? Is the TBA CONTROL PENDANT connected to the junction box (or to the control unit)? Are the detectors connected to the TANDEM XDR? Are the following devices connected with the power cord to the power line? TBA CONTROL UNIT TANDEM XDR SCANLIFT 38 D850.131.03/01 en

Operating Manual Error Messages and Troubleshooting 5 Error Messages and Troubleshooting If problems occur, please check the installation as outlined in section 2. The following list of possible problems may be a useful guideline for troubleshooting. NOTE When contacting our Service team, please give the full serial number of your device. For detailed information on the individual components, please refer to the corresponding user manuals. For control pendant operating instructions and troubleshooting tips, please refer to the user manual of the control unit and the control pendant. 1. The Power LED at the TBA CONTROL UNIT is not illuminated. 2. No information on the TBA CONTROL PENDANT display. 3. An axis does not respond when you push one of the direction buttons. Check whether the power cord is connected. Is the control unit turned on? Check the fuses in the cold appliance socket on the back of the device. Is the control pendant connected? When the control pendant is connected to the junction box: Is the control cable T43164/K1 properly connected between control unit and junction box? Is the POWER LED at the control unit illuminated? Refer to 1. If the control pendant reports a message, please refer to the user manual of the control pendant. Check the axis limits. If upper and lower limit are identical, the axis cannot be moved. For configuration of the limits, refer to the user manual of the control pendant. D850.131.03/01 en 39

Operating Manual Error Messages and Troubleshooting 40 D850.131.03/01 en

Technical Manual Technical Specifications Technical Manual 6 Technical Specifications Only values with specified tolerances or limits are guaranteed. Values without tolerances are for information purposes only. Description Manufacturer Use Electromagnetic compatibility Perspex tank Material Wall thickness side walls and bottom window Outside dimensions Inside dimensions Window dimensions Window position Deflection of the window with filled tank Max. water quantity Weight Mounting of special accessories MP3-P Therapy Beam Analyzer, L981403 PTW-Freiburg computer-controlled system for measuring dose distributions (depth dose curves and profiles) in order to check the emitted irradiation of particle accelerators (such as a cyclotron or synchrotron) suitable for operation in an industrial electromagnetic environment according to IEC 61326-1 PMMA 18 mm 5 mm 484 mm x 498 mm x 386 mm 448 mm x 480 mm x 350 mm 250 mm x 250 mm middle of moving range of B-axis and C-axis < 1.0 mm approx. 72 l approx. 30 kg (Perspex tank with moving mechanism and junction box) in front of the window, max. 15 kg D850.131.03/01 en 41

Technical Manual Technical Specifications Moving mechanism Moving range A-axis Moving range B-axis Moving range C-axis Reproducibility Positioning accuracy Step interval Max. cable length Positioning device Adjustments Vertical with a travel of Horizontal in the plane Pivoting around vertical axis Swiveling to positions Support plate material Outside dimensions Overall height in middle position Outside dimensions of the support plate Weight Effect of electromagnetic disturbances Rated range of use Temperature Relative humidity Atmospheric pressure Maximum operating altitude Environmental conditions for transport and storage Temperature Relative humidity Atmospheric pressure 350 mm 380 mm 250 mm 0.1 mm 0.5 mm 0.1 mm 40 m (between control unit and water phantom) 10 mm 10 mm approx. 1 0, 45 and 90 5 mm aluminum, anodized 571 mm x 669 mm 117.5 mm 536 mm x 634 mm approx. 22 kg no effect (+10... +40) C (10... 80) %, no condensation (max. 20 g/m³ absolute humidity) (700... 1060) hpa 3000 m above sea level (-20... +60) C (10... 85) %, no condensation (max. 20 g/m³ absolute humidity) (600... 1200) hpa 42 D850.131.03/01 en

Technical Manual Order Information 7 Order Information MP3-P basic equipment MP3-P Perspex tank with moving mechanism TBA junction box MP3-P accessories Cover, ball-shaped screwdriver SW 3, hexagon head screwdriver (SW 2.5, 3, 4, 5), circular bubble level, Fat Staburags NBU 12K, anti-corrosion fluid locking coupling T41029.1.512 MP3-P mounting kit TBA CONTROL UNIT TBA CONTROL PENDANT TBA control cable TBA motor cable SCANLIFT (incl. control unit) MP3-S positioning device, swiveling Bragg Peak chamber Thin-window Bragg Peak chamber Chamber holder for T34070 / T34080 Reference chamber for T34070 / T34080 TBA reference chamber holding device Bragg peak reference chamber holder Extension cable 'M6m HD' TBA chamber plug holding device TANDEM XDR Signal cable Interface cable RS232 TBA trolley Base plate L981403 T41029.1.500 T41029.1.150 T41013 T41031 T43164/K1-4 T43164/K2-4 T41024 T41002.1.016 TM34070-2,5 TM34080-2,5 T41029.1.250 T41029.1.260 T4316/U171 T4316/U561 T2954/K3-6 T4316/U161 T10037 T10006.1.002 T22373/K67-30 L656004 T20015.3.001 D850.131.03/01 en 43

Technical Manual Order Information Accessories Linear detector holder Bragg peak chamber 2.5 cm³ Chamber holder for type 34073 Reference chamber holder for type 34073 Inhomogeneous phantom Holding device for hemisphere PMMA wedge for MP3-P Film holding device T21004 TM34073-1,08 T41029.1.200 T41029.1.210 T43031 T41029.1.230 T41029.1.220 T40040 44 D850.131.03/01 en

Service Manual Cleaning Service Manual WARNING Improper execution of service tasks. Hazards to Persons! Equipment Damage! The following service tasks must only be performed by specially trained staff. Further service tasks may only be carried out by PTW-Freiburg or by persons authorized by PTW-Freiburg. 8 Cleaning 8.1 General Information on Cleaning WARNING Liquids have entered the product. Shock Hazard, Erroneous Measurement! The product must be thoroughly inspected by service personnel before being used again. CAUTION Disinfection of the surface with disinfectants on a phenol base or peroxide compounds. Equipment Damage! Do not use disinfectants on a phenol base or peroxide compounds to disinfect the surface. The product cannot be sterilized or completely disinfected. Clean the product simply by wiping it down with a dry or slightly moistened cloth. Use water or a mild soap solution. Alternatively, you can use a common disinfection agent for medical instruments which is specified in the list of disinfectants of your national hygiene institute (e.g., VAH in Germany). If your country does not provide such a list, we recommend either a solution on an aldehyde base or a solution with a quaternary ammonium compound. D850.131.03/01 en 45

Service Manual Cleaning 8.2 Device Surfaces First of all, disconnect the MP3-P system from the power line, before attempting to clean the device surfaces. Wipe the product down. Liquids must not be allowed to enter the product. Do not apply spray to the product or the connectors. 8.3 Connection Cables Clean the cables as follows: disconnect the cables from the devices, pulling on the plug, not on the cable for cleaning, rub the cables down with a cloth moistened with soap water or with disinfectant never immerse the cable in liquid! 8.4 Connectors Do not immerse the connectors in liquids! Do not let liquid enter the connectors. 8.5 Perspex Tank The Perspex tank is drained by pumping the water into the SCANLIFT water reservoir. The inclination required to completely drain the Perspex tank can be attained by adjusting one of the leg levelers of the positioning device accordingly. Do not tilt the tank manually. The supporting profile and the angle are adjusted by PTW-Freiburg. Do not remove them. For cleaning, use a mild cleaning agent suitable for plastic material or soap water. After cleaning, thoroughly remove all remains of the cleaning agent. You should coat the Perspex tank for storage with the delivered cover. 8.6 Moving Mechanism The shafts and toothed wheels of the moving mechanism should be lubricated with the supplied grease at intervals of 1 to 2 years or when necessary (use small amount of grease only!). The connectors must not become dirty. Clean the connectors only with a soft brush. Do not blow into the connector. 46 D850.131.03/01 en

Service Manual Preventive Maintenance 9 Preventive Maintenance In the following you will find a list of the maintenance measures and inspections necessary for the product. Check before each use Before each use, visually inspect the device and the cables for signs of mechanical damage. If damages or malfunctions are identified, the device must be repaired before it is used again. Technical Inspection of the Measuring System The system must be inspected at regular intervals according to national regulations. It is recommended to perform a technical inspection of the measuring system every 2 years at PTW-Freiburg or a qualified calibration laboratory. Inspections must also be performed after repairs or after each influence which may have changed the behavior of the device. Repair Repairs may only be carried out by PTW-Freiburg or by persons / companies authorized by PTW-Freiburg. Safety inspections Only regularly inspected devices are fail-safe. To preserve the functional security and operational safety, a safety inspection is to be executed at regular intervals according to national regulations. These inspections must only be performed by independent persons with adequate training and experience. It is recommended to execute the safety inspections every 2 years. D850.131.03/01 en 47

Service Manual Storage 10 Storage 11 Disposal of the Product To preserve a constant evenness of the plates made of PMMA (e.g. holder for inhomogeneous phantom), pay attention that these plates are stored horizontally and allow sufficient time for temperature equalization. The typical lifetime of the MP3-P Therapy Beam Analyzer system is about 10 years. At the end of the product life the system components must be disposed of in compliance with the applicable waste control regulations. The different materials must be separated and recycled as appropriate. The MP3-P Therapy Beam Analyzer system does not contain hazardous materials. The electronic components must be recycled according to local regulations. 48 D850.131.03/01 en

Literature Literature [1] Council Directive 93/42/EEC concerning medical devices (Medical Device Directive - MDD) [2] Council Directive 97/43/EURATOM on health protection of individuals against the dangers of ionizing radiation in relation to medical exposure [3] IEC 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use; Part 1: General requirement [4] IEC 61326-1 Electrical equipment for measurement, control and laboratory use - EMC requirements Part 1: General requirements [5] IEC/CISPR 11 Industrial, scientific and medical (ISM) radio-frequency equipment - Radio disturbance characteristics - Limits and methods of measurement. [6] IEC 60950-1 Information technology equipment - Safety Part 1: General requirements [7] IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and essential performance [8] IEC 60601-1-1 Medical electrical equipment Part 1: General requirements for safety; 1 st Collateral Standard: Safety requirements for medical electrical systems D850.131.03/01 en 49

Appendix: China Electronic Industry Standard Compliance Appendix: China Electronic Industry Standard Compliance 附录 : 中华人民共和国电子产业标准 This Supplement concerns China Electronic Industry Standard Compliance 此附录涉及中华人民共和国电子产业标准的相关规定 The following product pollution control information is provided according to SJ/T11364-2006 Marking for Control of Pollution caused by Electronic Information Products. 根据 SJ/T11364-2006 标准规定的 电子信息产品污染控制标识要求 特提供以下有关产品污染控制方面的信息 1. Explanation of Pollution Control Label 污染控制标识说明 This symbol indicates the product contains hazardous materials in excess of the limits established by the Chinese standard SJ/T11363-2006 Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products. The number in the symbol is the Environment-friendly Use Period (EFUP), which indicates the period during which the toxic or hazardous substances or elements contained in electronic information products will not leak or mutate under normal operating conditions so that the use of such electronic information products will not result in any severe environmental pollution, any bodily injury or damage to any assets. The unit of the period is "Year". In order to maintain the declared EFUP, the product shall be operated normally according to the instructions and environmental conditions as defined in the product manual, and periodic maintenance schedules specified in Product Maintenance Procedures shall be followed strictly. Consumables or certain parts may have their own label with an EFUP value less than the product. Periodic replacement of those consumables or parts to maintain the declared EFUP shall be done in accordance with the Product Maintenance Procedures. This product must not be disposed of as unsorted municipal waste, and must be collected separately and handled properly after decommissioning. 该标识表明本产品含有的有毒有害物质超出 SJ/T11363-2006 标准规定的 电子信息产品中有毒有害物质的限量要求 标识中的数字为本产品的环保使用期限 (EFUP), 表明在正常使用的条件下, 电子信息产品内含的有毒有害物质或元素不会发生外泄或突变, 用户使用该电子信息产品不会对环境造成任何严重污染或对人身 财产造成任何严重损害的期限 单位为年 为保证所声明的环保使用期限, 应按产品手册中所规定的指示和环境条件进行正常使用, 并严格遵守产品维护程序中规定的定期维护和保养日程 产品中的耗件或某些零部件可能具有单独的标识, 其环保使用期限有可能短于产品本身的环保使用期限 应按产品维护程序定期更换这些耗件或零部件, 以保证所声明的整个产品的环保使用期限 本产品在使用寿命结束后不可作为普通生活垃圾处理, 必须另行收集并作妥善处理 50 D850.131.03/01 en