Variable Area Flow Meters. VS Series

Similar documents
Measurement of Low GAS & Liquid Flows

KOBOLD KSM FLOWMETER. User Instructions

Glass tube flowmeters Series 2000

Level transmitter LT 100

Liquid level switch BM 34

GA24 Technical Datasheet

Flowmeter. Original operating manual DFM

Features. Up to 6 switch points Minimum degree of protection IP65 Optional temperature sensor PT1000 or thermostat Potted electrical contacts

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Solenoid valves VZWF, force pilot operated

Expansion Thermometers Stainless Steel Series, Model 70

VA40 - VA45 Technical Datasheet

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Gas density monitor With integrated transmitter Model GDM-100-TI

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

Instruction Manual Contact Pressure Vacuum Gauge

THE EXPERT IN LEVEL AND FLOW

FVA Trogflux variable area flowmeter. Operating Instructions. MECON GmbH 05/2013 OI_FVA_Trogflux_EN

High-performance submersible pressure transmitter For level measurement Model LH-10

SPD310/SPD360 Air Differential

Installation and Operating Instructions Bypass Flow Meter DST

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

L21S/SR/ST Glass Level Gauges

Variable Area Flow Meters

High-performance submersible pressure transmitter For level measurement Model LH-10

Pressure Transmitters 36 F-27839

Instruction Manual Differential Pressure Transmitter

How to specify a product. Process Sensors and Mechanical Instruments

JUMO dtrans p30 Pressure Transmitter

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Bourdon tube pressure gauges for chemical applications EN 837-1

Pressure Reducing Valve DMV 750 set range: bar

Variable area flowmeter F VA 250

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Operating instructions for variable area flow meter with needle valve. Model: UVR/UTR

Instruction presentation Special valves

Orifice Plate Flow Meter

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Technical Information. Overview Rotameter. TI 1R1A0-E-H 4th edition

Mechanical Pressure Measurement

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Liquid level instruments BM 24 /BM 51

Installation and Operation Manual

The number of revolutions is proportional to the passed volume. The rotation is transferred to a mechanical index, which indicates this volume.

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

WATER METERS.

FVA Tubux M30 Variable Area Flowmeter. Operating Instructions. MECON GmbH 07/2013 OI_FVA_Tubux_M30_EN

Bourdon tube pressure gauge for diaphragm seals

Compact pressure switches for gas and air

Pressure Reducing Valve DMV 755

Magnetic Level Gauges

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Mass Flow Meter (MFM) for Gases

Pressure Reducing Valve DMV 750

STAD. Balancing valves DN (MD60, MD61, MD62)

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Technical Information Conducal CLY421

Old documentation - Only for your information! Product is not available anymore!

RMG Meßtechnik GmbH. Publication No E

PTFE-SINGLE GLASS FLOW METERS

SonoMeter 30 Energy Meters

2/2-Way Solenoid Control Valve

Proportional pressure regulators VPPE

Process Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.

AVPQ/AVPQ-F, PN 16. Application

Mass Flow Controller (MFC) for Gases

SITRANS P measuring instruments for pressure

Electronic Turbine Meter TERZ 94

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

Drum-Type Gas Meters Series TG (Wet-Test)

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Armatures for analytical probes

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

Tightness control TC. Product brochure GB 3 Edition AGA

Pressure Switch for gas and air GGAO-A4

Magnetic level switch type MR783 Instruction Manual

Expert Hydrostatic Level Transmitters

[Instruments for vacuum measurement, checking and adjustment] 3

Instructions Manual. Variable area flowmeter 60 M-1. Series. instrumentation for fluids. Technical Data. C-MI-60M1 Rev.: 0 English Version

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

AVP-F. p setting range (bar) Code No. 003H6200

STA. Double regulating valves DN 15-50

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Seated valves VRB 3, VRG 3

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

Transcription:

Variable Area Flow Meters VS Series

Precise measuring in water flow Design and function VS series fl ow meters operate with the fl oat principle. A fl oat is located in a conical plastic tube. The fl oat rises and falls as the medium passes depending on fl ow. The current fl ow is indicated on the scale at the top of the fl oat. These instruments use a water scale in l/h and a % scale as standard. Optional air scales are also available for various operating pressures. Monitoring of the fl ow rate is facilitated by two adjustable indicators. Limit switches are available as accessories. Advantages Unbreakable and corrosion resistant Radially extendable Special self-adhesive scales for liquid and gaseous media Check rail for accessories (limit switches) Size (DN), measuring range and material marked on tube Floats and stops generally made of PVDF Measuring ranges 1.5...60.000 l/h Dimensions VS1... L = 335 mm G DN dm L z Lm dü 1½ 25 32 335 341 385 60 2 32 40 335 341 393 72 2¼ 40 50 335 341 403 83 2¾ 50 63 335 341 417 103 3½ 65 75 335 341 429 122 VS3... L = 165...200 mm G DN dm L z Lm dü ¾ 10 16 165 171 199 35 1 15 20 185 191 223 43 1½ 25 32 200 206 250 60 Installation instructions The fl ow meters should be installed in a vertical position and free of stress in the pipe system An inlet and outlet section must be provided; inlet about 10 x DN, outlet about 5 x DN Notes on use Hydraulic shocks must be avoided as these can damage the instrument Install the instrument with care, the tube must not come into contact with solvents Ensure that the plastic union nuts are tight prior to use -2-

Technical data Series VS11... VS12... VS13... VS32... VS33... General data Accuracy Class 4 according to VDE/DIN 3513, page 2 Nominal pressure rating 20 C PN 10 Medium temperature 0...60 C 0...100 C 0...40 C Materials Tube PA PSU PVC Float PVDF O-ring EPDM Measuring accuracy VS1... and VS3... Flow rate in % 10 20 30 40 50 60 70 80 90 100 Total error of measured value in % 13.00 8.00 6.33 5.50 5.00 4.67 4.43 4.25 4.11 4.00 Total error of range in % 1.3 1.6 1.9 2.2 2.5 2.9 3.1 3.4 3.7 4.0 VS1... Type VS1 25 A... VS1 25 B... VS1 32 C... VS1 32 E... VS1 40 D... VS1 40 F... VS1 40 G... ] ] ] ] ] ] ] ] ] ] ] ] ] VS1 50 G... VS1 50 H... VS1 50 I... VS1 65 J... VS1 65 K... VS1 65 L... Nominal size Measuring range l/h (water) DN 25 50...500 100...1000 DN 32 150...1500 250...2500 DN 40 200...2000 300...3000 600...6000 DN 50 600...6000 1000...10000 Pressure drop mbar* 22.84 22.84 24.99 24.99 1500...15000 28.23 DN 65 2000...20000 45.67 3000...30000 8000...60000 47.24 VS3... Type VS3 10 P... VS3 10 Q... VS3 10 R... VS3 10 T... VS3 15 S... VS3 15 U... VS3 15 V... VS3 VS3 VS3 VS3 25 U... 25 W... 25 A... 25 B... * within total measuring range * within total measuring range ] ] ] ] ] ] ] ] ] ] ] Nominal size Measuring range l/h (water) DN 10 1.5...15 2.5...25 5...50 10...100 DN 15 8...80 15...150 20...200 DN 25 15...150 30...300 50...500 100...1000 Presure drop mbar* 4.51 4.38 8.12 VS1... series (L = 335 mm) VS3... series (L = 165...200 mm) -3-

Measuring ranges in air VS1... Series (L= 335 mm), pressure range 0...4 bar 0 bar 1 bar 2 bar 3 bar 4 bar Type Nominal size m³/h STP* m³/h STP* m³/h STP* m³/h STP* m³/h STP* VS1 25 A... VS1 25 B... DN 25 1.5...14 2.5...29 3...20 4...41 3...24 5...50 3...28 5...58 4...31 6...65 ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] VS1 32 C... VS1 32 E... VS1 40 D... VS1 40 F... VS1 40 G... VS1 50 G... VS1 50 H... VS1 50 I... VS1 65 J... VS1 65 K... DN 32 4...45 7...79 DN 40 6...58 9...108 17...174 DN 50 17...175 29...301 53...405 DN 65 55...545 80...758 6...63 10...111 9...82 13...152 24...246 24...247 41...425 75...572 78...770 113...1072 VS1... Series (L = 335 mm), pressure range 5...8 bar VS3... series (L = 165...200 mm), pressure range 0...5 bar VS3 10 P... VS3 10 Q... VS3 10 R... VS3 10 T... VS3 15 S... VS3 15 U... VS3 15 V... VS3 25 U... VS3 25 W... VS3 25 A... VS3 25 B... DN 10 0.01...0.55 0.2...0.95 0.5...1.9 0.8...3.0 DN 15 0.6...2.8 1.4...5.6 1.5...7.0 DN 25 1.0...6.5 1.5...11 3...18 6...30 7...77 12...136 11...100 16...186 30...301 30...302 51...520 92...700 96...942 139...1311 8...90 14...158 12...116 18...216 34...348 34...350 58...602 106...810 110...1090 160...1516 9...100 16...177 14...130 21...241 39...389 39...392 65...674 119...907 124...1220 180...1697 5 bar 6 bar 7 bar 8 bar Type Nominal size m³/h STP* m³/h STP* m³/h STP* m³/h STP* VS1 25 A... VS1 25 B... DN 25 4...34 7...71 5...37 7...76 5...39 8...82 4.5...42 7.5...87 VS1 32 C... VS1 32 E... VS1 40 D... VS1 40 F... VS1 40 G... VS1 50 G... VS1 50 H... VS1 50 I... VS1 65 J... VS1 65 K... DN 32 10...110 18...193 DN 40 15...142 23...264 42...426 DN 50 42...428 72...737 130...992 DN 65 135...1335 197...1857 0 bar 1 bar 2 bar 3 bar 4 bar 5 bar m³/h STP* m³/h STP* m³/h STP* m³/h STP* m³/h STP* m³/h STP* 0.15...0.80 0.25...1.3 0.7...2.7 1.0...4.2 0.8...4 2...8 2...10 1...9 2...15 4...25 8...44 * standard conditions for temperature and pressure, 0 C, 0 bar positive pressure 11...119 19...209 16...153 24...286 45...461 45...463 77...797 141...1073 146...1444 212...2008 0.17...0.9 0.3...1.6 0.8...3.4 1.2...5.4 1.0...5.0 2...10 3...13 1.5...11 2.5...18 5...30 10...54 12...127 20...223 17...164 26...305 49...492 49...495 83...851 150...1146 156...1542 227...2145 0.20...1.1 0.4...1.9 1.0...3.8 1.4...6.4 1.2...5.6 3...12 3...15 2...13 3...22 5...35 12...62 0.25...1.20 0.4...2.1 1.2...4.2 1.6..7.0 1.4...6.4 3...13 4...17 2...14.5 3...24 6...40 12...70 12...135 21...237 18...174 27...324 51...522 51...525 87...903 159...1215 165...1635 240...2274 0.25...1.3 0.5...2.4 1.2...4.6 1.6..7.4 1.4...7.0 3...14 4...18 2...16 4...26 6...44 15...75-4-

VS3... Series (L = 165...200 mm), pressure range 6...10 bar 6 bar 7 bar 8 bar 9 bar 10 bar Type Nominal size m³/h STP* m³/h STP* m³/h STP* m³/h STP* m³/h STP* VS3 10 P... VS3 10 Q... VS3 10 R... VS3 10 T... DN 10 0.26...1.45 0.5...2.5 1.2...5.0 2.0...8.0 0.30...1.5 0.5...2.7 1.4...5.4 2.0...8.8 0.3...1.6 0.6...2.9 1.4...5.8 2.0...9.0 0.3...1.7 0.6...3.0 1.6...6.0 2.0...10 0.35...1.8 0.6...3.2 1.6...6.4 2...10 VS3 15 S... VS3 15 U... VS3 15 V... DN 15 1.5...7.5 3.5...15 4...20 1.5...8.0 3.5...16.5 5...21 1.5...8.5 4...17 5...23 2.0...9.0 4...18 5...23 2.0...9.5 4...19 5...25 VS3 25 U... VS3 25 W... VS3 25 A... VS3 25 B... DN 25 2...17 4...28 8...48 15...80 2.5...18 4...30 8...50 15...85 2.5...19.5 4...33 8...54 20...90 3...20 5...34 8...56 20...95 3...21 5...35 10...60 20...100 ] ] ] ] ] ] ] ] ] ] ] * standard conditions for temperature and pressure, 0 C, 0 bar positive pressure. Limit switches Application The limit switches VSK1 and VSK2 serve for external monitoring of limited fl ow rates on our variable area fl ow meters. They are fi tted on the check rail on the fl ow meter and can be adjusted to any switching point on the respective scale. Switching states Function The magnet in the fl oat closes or opens a reed contact encapsulated in the limit switch. The switching function is bistable. This means that switching state is also maintained when the magnetic fl oat is at a distance from the contact. Important to note when retrofi tting limit switches is that the standard fl oat must be replaced with a magnetic fl oat. Technical data Switching voltage max. 230 V AC / DC Switching capacity max. 10 W / 12 VA Switching current max. 0.5 A Contact resistance 200 mohm Insulation resistance 10 11 Ohm Ambient temperature 0...55 C Degree of protection IP 65 according to DIN 40050 Switching hysteresis 1-2 mm fl oat travel min. limit switch VSK1 max. limit switch VSK2 Switching states and order code Limit switches Float Order code below above min. limit switch VSK1 max. limit switch VSK2-5-

Order code VS1... Ordering example VS11 25 A 11 W0 Tube material PA Trogamid PSU PVC Nominal size and measuring range l/h water Float Scale DN 25 DN 32 DN 40 DN 50 DN 65 50...500 100...1000 150...1500 250...2500 200...2000 300...3000 600...6000 600...6000 1000...10000 1500...15000 2000...20000 3000...30000 8000...60000 Standard with magnet (for use with limit switches) Water l/h and % Air 0 bar Air 1 bar Air 2 bar Air 3 bar Air 4 bar Air 5 bar Air 6 bar Air 7 bar Air 8 bar VS11 VS12 VS13 25 A 25 B 32 C 32 E 40 D 40 F 40 G 50 G 50 H 50 I 65 J 65 K 65 L 11 21 W0 00 10 20 30 40 50 60 70 80-6-

VS3... Ordering example VS32 10 P 11 W0 Tube material PA Trogamid PVC Nominal size and measuring range l/h water VS32 VS33 DN 10 DN 15 DN 25 1.5...15 2.5...25 5...50 10...100 8...80 15...150 20...200 15...150 30...300 50...500 100...1000 10 P 10 Q 10 R 10 T 15 S 15 U 15 V 25 U 25 W 25 A 25 B Float Scale Standard with magnet (for use with limit switches) Water l/h and % Air 0 bar Air 1 bar Air 2 bar Air 3 bar Air 4 bar Air 5 bar Air 6 bar Air 7 bar Air 8 bar Air 9 bar Air 10 bar 11 21 W0 00 10 20 30 40 50 60 70 80 90 Z0-7-

Our Production and Sales Range Flow Sensors without moving Parts Turbine Flow Sensors Flow Switches Pressure Gauges and Pressure Sensors Industrial Thermometers Electronic Digital Thermometers, Dial Thermometers Measuring Instruments Temperature Sensors Your competent partner for measurement and control Calibrators, DKD-Laboratory...measurement...control...calibration Phone: 0700 CALL SIKA Phone: +49 5605 803-0 Fax: +49 5605 803-54 E-Mail: info@sika.net Internet: http://www.sika.net Struthweg 7-9, 34260 Kaufungen P. O. Box 1113, 34254 Kaufungen Germany Durchfl ussmessgeräte_vs_e 01/2011