Analyte G2 Excimer Laser Ablation System Site Preparation Guide

Similar documents
Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

ver #. (Indicate version number) (Current Date of Version)

Varian 325-MS LC/MS Quadrupole Mass Spectrometer Pre-installation Instructions

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Customer Responsibilities

CUNY ASRC Photonics Spectroscopy Facility User Policies

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

Preparing Your Laboratory for the Optima 7300 V and 8300 ICP-OES Spectrometers

Technical Operating Instructions for Magnum Cutting Systems. for online instructions

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Columbus Instruments

Avio 500 ICP-OES. ICP-Optical Emission Spectroscopy PREPARING YOUR LAB. Preparation Checklist. Suitable Working Area

BGA244 Binary Gas Analyzer

Installing ASI Umbilical Delivery Systems

Laboratory Personal Protective Equipment & Hazard Assessment Tool

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

UltraLo 1800 Alpha Particle Counter

Department of Electrical Engineering & Computer Science. Electrical Safety. for Staff and Students in EECS Instructional Laboratories

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

EGL-12 OIL-LESS COMPRESSOR

Material Handling and Storage of compressed gases and Air equipment

Lecture Demonstrations Safety Manual & New Staff Induction

92831 TEL: (714) FAX:

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

SAFETY AND OPERATION MANUAL

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Laboratory Ventilation. Environmental, Health, and Safety

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

RPS900W Redundant Power Supply. Installation Guide.

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

DEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

TABLE OF CONTENTS PART 2 - CONFINED SPACES

Basic & Controlled Atmosphere Glove Boxes

92831 TEL: (714) FAX:

Discovery HP-TGA 75/750. Site Preparation Guide

Your local gas generation partner. Precision series Modular gas generation solution for GC.

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

KARL SUSS MJB3 UV400 Mask Aligner Standard Operating Procedure

Discovery SDT 650. Site Preparation Guide. Revision G Issued December Page 1

CONFINED SPACE PROGRAM

Varian 240-MS GC/MS Ion Trap Mass Spectrometer Pre-installation Instructions

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

HumiSys HF High Flow RH Generator

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

USER MANUAL LTH-255A Hand Piece

M5400 Operators Manual

This training does not attempt to cover all safety regulations or precautions.

DEEPSEA. SeaLite Lumos POWER & LIGHT. Operator s Manual Ruffin Road San Diego, CA USA.

23.1 Functions, Basic Configuration, and Interfaces

Standard Operating Procedure - First Draft for Review Only- StarWeld Ultra DX

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

MODEL GENERA PURGE TURBINE INSTR DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

Laboratory Safety Committee

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

GAS FUEL VALVE FORM AGV5 OM 8-03

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Radiation Producing Machines Radiation Safety Training for X-ray Diffraction Units

Safety in the Laboratory

PS Plasma 375 Plasma Cutter Kit Assembly & Operating Instructions

In Vivo Scientific, LLC INSTRUCTION MANUAL

Agilent Auxiliary Gas Module AGM 2. User s Guide

General Precautions for handling compressed gases

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Test Facilities Experiment Review

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure

Best Practice Guide, Servomex 2700

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

Standard Operating Procedure (SOP) Compressed Gas Cylinders (Original SOP from Eastern Washington University)

Safety Data Sheet. Zero Air 1 PRODUCT AND COMPANY IDENTIFICATION. Manufacturer NorLab a division of Norco 898 W. Gowen Rd.

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

490 Micro GC Site Preparation Checklist

Instructions for Cleaning & Maintaining Air Compressor

Vision Painting Inc Safety Management System

Gas delivery systems. How to ensure uninterrupted high quality gas delivery from the source to the apparatus? Dr. Gastons Vereskuns Trakai,Lithuania

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Customer Responsibilities

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

NovelBright LED Illuminator

PURPOSE OF THE POLICY

Precision Hydrogen (All B&W Screen Models)

Piped Air SCBA Refilling System Standard

Operations Manual D , Rev A May Rosemount CT5100 Continuous Gas Analyzer

Operating Instructions Part No

Confined Space Entry Policy

780S Ultra High Purity Series

ETT Olfactometer: Getting started guide 2013a. ETT Olfactometer quick start

OPERATING INSTRUCTIONS FOR PRO HE HELIUM ANALYZER DANGER

For additional information about our solutions, please visit our web site at US/Pages/HomePage.

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

PROCESS ANALYSERS. SERVOPRO PureGas. Gas Purifier. Operator Manual. Part Number: A Revision: 0 Language: UK English

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Transcription:

Analyte G2 Excimer Laser Ablation System Site Preparation Guide Manual Part Number 6100-0003 Rev 2.6 2013-2017 Teledyne Technologies Incorporated. All rights reserved. Printed in USA.

Product Overview The Analyte G2 excimer laser ablation system is a complete, high performance, excimer laser ablation workstation in a compact package that is designed for high energy density 193 nm operation. All materials required for interfacing with an ICP-MS are provided, except for the laser gases, the carrier gases, and their respective containers with pressure regulators. This document describes how to prepare your laboratory for the Analyte G2. Please review this document in its entirety and provision for the Analyte G2 prior to its arrival. The Analyte G2 laser ablation system will arrive in a single wooden crate measuring 135 x 80 x 160 cm that weighs 584 kg gross. A pallet jack or forklift is required. Move the crate to a dry, clean area immediately upon arrival and maintain room temperature. Installation is performed by trained service engineers from Teledyne Photon Machines. Safety Considerations Before the Analyte G2 arrives, all laboratory personnel should become familiar with this safety information. Your organization may also have specific requirements; provide this information to the person responsible for laser safety (this person is usually called a Laser Safety Officer). Overview INJURY HAZARD The Analyte G2 contains internal components that present severe electrical and radiation hazards. Improper operation or servicing can result in death, blindness, other injury or material damage. Only qualified personnel should operate or service this equipment. It is important to read the following safety precautions in detail to prevent bodily injury and damage to the Analyte G2 laser ablation system or any interfacing devices. Use only as specified. Potential health and safety hazards are discussed in greater detail in the remainder of this section, including but not limited to: Eye Damage from Direct or Reflected Laser Beam Exposure Skin Damage, including increased risk of cancer, from Direct or Reflected Laser Beam Exposure Fire Danger from Laser Beam and Electrical Components Electrical Shock Hazard Inhalation Hazard and Stored Energy Hazard from Compressed Gases Laser light poses safety hazards that are not associated with conventional light sources. Special precautions must be observed when operating, maintaining, or servicing the Analyte G2. The safe use of high-powered lasers requires that each operator be fully trained and that all personnel working in proximity to the laser are aware of the dangers involved. Teledyne Photon Machines assumes no liability related to use of this product. 2

Optical Safety Lasers are classified by the US Food and Drug Administration according to the health hazards associated with exposure to their emitted beam, based on power and wavelength. Class 1 lasers are considered eye-safe and require no special safety measures during operation or maintenance. Class 4 lasers can produce instantaneous and permanent blindness or serious injury to the eye or skin and require stringent safety measures during operation and maintenance. The Analyte G2 falls under both of these categories, depending on the mode in which it is used. The Analyte G2 utilizes excimer laser sources which can produce high-intensity laser beams in the ultraviolet (UV) portion of the spectrum. The specific wavelengths produced is 193 nm. The Analyte G2 meets the requirements for Class I laser device when all panels are closed. Safety interlocks prevent operation with panels opened or removed. To ensure safe operation, the interlocks must never be defeated. With any portion of the housing removed, or the sample chamber removed or disassembled, the Analyte G2 can emit Class 4 laser radiation. INVISIBLE RADIATION HAZARD Infrared and ultraviolet radiation are invisible, so the hazard they present is not immediately obvious. Direct or reflected exposure to infrared, visible, or ultraviolet laser beams can cause blindness or vision impairment without warning. Reflected energy can be dangerous whether specular or diffuse. It is extremely important that anyone who might be exposed to direct or reflected Class 4 laser radiation wear suitable safety glasses. Skin Exposure Safety Laser radiation is a high-intensity beam of well-collimated light that can propagate substantial distances without substantial loss of intensity. The radiation emitted is nonionizing under normal circumstances, but can cause thermal damage to tissue due to radiation absorption. Generally, the maximum permissible radiation exposure for skin is several times greater than for the eye. Safety measures with regard to radiation hazards are therefore based mainly on dangers to the eye, but exposure to the skin should be carefully avoided as well. Direct or reflected laser radiation can cause burns as well as an increased risk of cancer. INJURY HAZARD Use the system only when all safety features are working. When operated as designed with the laser enclosure closed, the Analyte G2 meets Class 1 laser safety requirements and so requires no special precautions. However, the device contains internal components categorized as Class 4. Conformance to Class 1 is maintained by design features and safety systems which normally prevent exposure to these hazards. The Analyte G2 is a Class 4 device when these features are disabled or inoperative. 3

Fire Safety The energy of the excimer lasers used in the Analyte G2 at any of the wavelengths involved is sufficient to produce a spark or explosion hazard if directed carelessly. The laser beam or its reflection can ignite combustible or volatile substances such as solvents. If non-oxidizing gas purge is used, the purge gases will generally prevent combustion in the sample chamber, and the safety features built into the Analyte G2 should prevent laser energy from propagating outside the device. Electrical Safety There are no user-serviceable electrical parts in the laser power supplies or other components of the Analyte G2. The manufacturer must carry out service procedures on power supply electronics. General rules of electrical safety should be followed at all times. Most maintenance procedures which require removal of portions of the protective housings, such as cleaning optical components, require no operation of the Analyte G2 laser system and they should be conducted only after the following steps are completed: 1 Turn the laser system off. 2 Unplug the AC power cord at both ends and remove it. 3 Allow 5 minutes for the internal capacitors to discharge. ELECTROCUTION HAZARD The laser head and power supply of the Analyte G2 contain electrical circuits operating at lethal levels of voltage and current. Do not operate the laser system with either power supply or laser head covers removed except during maintenance procedures described in this manual. Compressed Gas Safety INHALATION HAZARD The laser ablation system uses pressurized gas containing fluorine, which is toxic and corrosive and may cause serious injury if inhaled. Provide adequate ventilation at all times. Learn and follow your laboratory s safety policy for caustic gases. If a gas release is suspected, do not enter the room without protective equipment including self-contained breathing apparatus. COMPRESSED GAS HAZARD All compressed gases are potentially hazardous because of the high pressure stored inside the cylinder. A sudden release of pressure can cause injuries by propelling a cylinder or whipping a line. This product is intended for use only by qualified operators who have been trained in safe laboratory practices and compressed gas handling. Safety Features The following safety features are incorporated into the Analyte G2 and conform to government regulations to provide safe laser operation. With any safety issues, please contact Teledyne Photon Machines for resolution of difficulties or assistance with repairs. 4

Beam Delivery Housing The standard Analyte G2 excimer laser beam is entirely enclosed by a protective housing which prevents access to radiation in excess of Class I limits and blocks stray radiation. The excimer laser beam exits the laser into the light-tight safety enclosure and is fully contained. The enclosure has redundant interlocks which should not be defeated. If a defect in the enclosure or the interlocks is suspected, operation should not continue until the defect is repaired. Laser Housing The electrical components associated with the excimer laser used in Analyte G2 are enclosed in a protective housing that limits exposure to dangerous electrical hardware. The covers should be removed only by trained personnel performing maintenance. Interlocks The Analyte G2 features the following interlocks which prevent operation in specific unsafe conditions: Remote Interlock Tripped This interlock allows the user to disable the system based on some remote triggering event, such as a door opening. The use of this interlock is optional. Translucent Safety Shield The interlock secured to the safety shield will activate whenever the safety shield is opened or removed. Applicable Regulations Laser Classification Government standards and regulations specify that laser-based products be classified according to the output power or energy, and laser wavelength. The standard Analyte G2 is supplied as a Class 1 device, while non-standard configurations are available as Class 4 devices. These non-standard systems are identified by model numbers other than those covered by this manual and will be clearly labeled as Class 4 devices. In either case, the excimer laser incorporated into the Analyte G2 is classified as Class IV based on 21 CFR, subchapter J, part II, section 1040-10(d) and Class 4 based on EN 60825-1, Clause 9 of the European Community Standards. General Laser Safety Teledyne Photon Machines recommends that laser users become more familiar with laser safety practices and the applicable regulations than is possible by reading this manual. The American National Standards Institute (ANSI) publishes a good overview titled American National Standard for the Safe Use of Lasers (ANSI Z136.1-2014). This publication provides recommendations for the safe use of lasers and laser systems that operating at wavelengths between 180 nm and 10 µm. The publication is available from: Laser Institute of America 12424 Research Parkway, Suite 125 Orlando, FL 32826 (407) 380-1553 www.laserinstitute.org/publications/safety_bulletin/laser_safety_info/ 5

Site Requirements Environment The Analyte G2 is an analytical instrument intended for use in a laboratory environment. Dust and humidity can result in degradation of the optical components having an adverse effect on the performance of the system. Maintain humidity of < 60%. For optimal performance room temperature should be kept within 68 to 75 Fahrenheit (20 to 24 Celsius). Electrical The Analyte G2 requires a single power cord. The power supply is fused and power distribution to all electronics is internal to the system. The power outlet should be located within 2 meters of the system. NOTE Please indicate the preferred connector type when you schedule installation. There are various configurations; if you do not specify a connector type, the power cable will be sent with the standard connector shown below. POWER: 210 to 240 VAC 50/60 Hz 10A STANDARD U.S. CONNECTOR 3 pole, L6-20P NEMA (specify alternative connector if needed). SHOCK HAZARD The Analyte G2 is designed for use with grounded electrical outlets only. This is an important safety feature. Operating the system ungrounded will result in an increased risk of electrical shock and equipment damage. 6

Space The Analyte G2 is a self-contained mobile workstation on locking roller casters. The premix gas bottle and helium gas bottles (not provided see page 9) are mounted within the cart. Overall dimensions are shown below. The distance between the Analyte G2 and ICP-MS should be kept to a minimum to ensure efficient transport of the entrained analyte from the sample chamber to the torch. NOTE Vent the 125 mm OD exhaust ports from the laser to outside of the room if desired. Keep in mind that the cables and tubing could create a trip hazard. Place the laser ablation system away from high-traffic walkways. 7

Computer An integrated computer with 22 flat screen monitor is provided. The system operates from the integrated ICP-MS host computer. The computer uses the Microsoft Windows 10 operating system. Ventilation The exhaust system must support a flow rate of 2800 L/m (100 cfm). Exhaust air comes from two sources: 100 L/m (3.5 cfm) cooling air exhaust from the laser, and 2667 L/m (94.2 cfm) from the gas cabinet. The exhaust system should be attached using flexible hoses having an inner diameter of approximately 125 mm. If the hosing run is longer than 3 m, an additional exhaust booster fan may be needed. The exhaust can be vented to the room; however, venting the air to the outdoors or into a filter system as a safety precaution is recommended. The heat generated by the laser is less than 150 watts. The exhaust air contains small amounts of ozone, which is produced in all high voltage switching systems. The O 3 concentration is less than the OSHA Permissible Exposure Limit (PEL) of 0.1 ppm. In addition, the exhaust air can contain corrosive and hazardous gases in the rare event of damage to the laser chamber, laser window/mirror or the gas system. The laser ablation system uses pressurized gas containing fluorine, which is toxic and corrosive and may cause serious injury if inhaled. Follow your laboratory s safety policy for caustic gases. 8

Gas Requirements You must supply the necessary gas sources. NOTE INSTALLATION CANNOT BE SCHEDULED UNTIL THE LASER GASES ARE ON-SITE. DELIVERY TIME CAN BE AS LONG AS 4 TO 6 WEEKS. There are three separate gas systems associated with the laser ablation system: 1) gases associated with the laser itself; 2) beam purge gases; 3) sample gases carrying analyte to the MS. These systems are completely isolated from each other. Note that the He and ArF bottles mentioned below for the laser must be purchased with the size, purity, and fitting style specified. Alternative sources, bottles, or grades cannot be used as a substitute for the dedicated laser He bottle that goes inside the laser system. Laser Gases The ATLEX short pulse excimer laser used in the Analyte G2 requires two dedicated gas bottles for operation: ArF laser gas and He flush gas. These bottles remain permanently attached to the laser. Provisioning for the correct gas bottles is an essential part of site preparation. All required plumbing and regulators are included with the Analyte G2 for these Laser Gas and Flush Gas bottles only. This plumbing extends into a small, closed gas cabinet below the laser where the two small gas bottles reside. If bottles other than the size listed are purchased, they will not fit into this cabinet and the system cannot be installed. CAUTION Use only the specified gas. Linde Electronics and Specialty Gases is the only factory approved premix laser gas supplier. Gases provided by other suppliers can result in serious damage to the laser and will void the warranty. Linde Electronics and Specialty Gases A division of Linde Gases N.A. LLC 1 Greenwich St. Suite 100 Stewartsville, NJ 08886 www.lindepremiumproducts.com 9

customerservice.esg.us.lg@linde.com phone 1-800-932-0624 The supplier maintains a specific stockpile of gas for Teledyne; when ordering, be sure to mention that you are a Teledyne customer. Certified Laser Gas ATL ArF 2 mixture in a 7 liter steel bottle with DIN #14 connector Linde PN 24099405 Excimer Grade Fluorine ATL ARF-2 DIN 477 No 14 for Premix Cylinder Size 030 Liters: 1000 Psig: 2000 NOTE If you are re-installing an older laser ablation system, with an ATL laser serial number less than 130204, order PN 24086541 Excimer Grade Fluorine ATL ARF-1 (ArF 1 ). Flush Gas Helium (UHP 99.999%) in a 7 liter steel bottle with DIN #6 connector Linde PN: 24086592 Excimer Grade Helium RG DIN 477 No 6 for Helium Cylinder Size 030 Liters: 1000 Psig: 2000 Other Required Gases Beam Purge Gas Approximately 2 L/min of nitrogen gas (UHP >99%) is channeled through the optical train when the laser is firing to suppress the formation of ozone and minimize absorption of 193 nm laser light in air. The N 2 pressure must be regulated at the tank down to 30 psi max. NOTE ¼ O.D. 1/8 I.D. Tygon tubing should be used to connect to the Swagelok connector of the rotameter provided with the system. The rotameter regulates the 2 to 3 L/min to the optical train. The user must supply a regulator for their purge gas bottle as well as tubing to connect to the Swagelok fittings on the back of the Analyte. 10

ICP-MS Sample Carrier Gas The convention is to channel helium gas (99.998% purity) into the sample chamber and supplement this with argon make-up gas using a Y junction (provided) after the sample chamber. Both gases should be made available (0.1 to 2 L/min) on site at the time of installation. When using argon as make up gas the Y junction is typically located just before the torch. The Analyte G2 comes with mass flow controllers to regulate the supply of helium through the sample chamber. However, the argon make up gas must be regulated by a mass flow controller as well. Often the ICP-MS has an auxiliary supply of argon that is suitable for this purpose. An optional mass flow controller can be provided with the Analyte G2 or added during installation. Contact the Teledyne Photon Machines dealer for additional information. If the mass flow controllers used to regulate the argon make-up gas is supplied by Teledyne Photon Machines then the pressure from the gas tanks / cylinders to the mass flow controllers must be regulated at the tank down to 30 psi max. NOTE Use ¼ OD 1/8 I.D. Tygon tubing to connect purge gas and carrier gas to the Swagelok connectors provided with the system. The user must supply regulator(s) for their carrier gas bottle(s), and tubing to go from the regulator(s) to the Swagelok connectors on the back of the Analyte. Tubing and a torch bulb to go from the Analyte to the ICP-MS are provided. Optional Nitrogen Gas Supply If the optional low-flow N 2 mass flow controller is installed, then a regulated supply of N 2 needs to be available for connection. Getting Help Teledyne Photon Machines is a brand of Teledyne CETAC Technologies. If you need further assistance, contact us at: Teledyne Photon Machines Customer Service & Support 366 Gallatin Park Drive Bozeman, MT 59715, USA Phone (406) 586-2667 Fax (406) 600-9744 Email robin.jones@teledyne.com http://www.cetac.com 11

Site Prep Checklist & Installation Scheduling Form Please satisfy the items in this checklist then return the form to schedule installation of your Analyte G2 laser ablation system. 210 240VAC outlet with mating connector readied ArF 2 premix gas received from Linde Helium flushing gas received from Linde Helium carrier gas supply, including 2-stage regulator with 1/4" OD or 6 mm OD to laser ablation system N 2 purging gas supply, including 2-stage regulator with 1/4" OD or 6 mm OD to laser ablation system Argon make-up gas supply regulated by ICP nebulizer line or external mass flow controller Crate inspected for damage (notify factory if any) Crate moved to the lab or just outside of lab Mass spectrometer(s) confirmed operational Location of Equipment: User Name Institution Street City State / Country Postal Code Key Contact Telephone Email Mass Spec Make/Mode I certify that all installation requirements listed above have been met and that the laboratory is prepared for the installation. Signature: Date: Please sign and email this form to robin.jones@teledyne.com