Portable Gas Analyzers

Similar documents
973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Mathieu Guertin. Morgan Schaffer Inc. Canada. Director Europe, Russia and Africa. A cost effective strategy for smart grid technology adoption

Columbus Instruments

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

Additel 761 Automated Pressure Calibrators

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Gas-Detection Instruments

ADT 761 Automated Pressure Calibrator

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Additel 761 Automated Pressure Calibrators

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

FPG8601 Force Balanced Piston Gauge

Pneumatic high-pressure controller Model CPC7000

Model Description

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Discovery HP-TGA 75/750. Site Preparation Guide

Pneumatic high-pressure controller Model CPC7000

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

BUBBLER CONTROL SYSTEM

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Online DGA-monitoring of power transformers

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

IRwin Methane Leak Detector. Innovation makes the difference

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

SF 6 Product Guide. Gas Analysis Instruments and Accessories

Autocalibration Systems for In Situ Oxygen Analyzers

490 Micro GC Site Preparation Checklist

For additional information about our solutions, please visit our web site at US/Pages/HomePage.

Discovery SDT 650. Site Preparation Guide. Revision G Issued December Page 1

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Automatic Test and Calibration Station

Your local gas generation partner. Precision series Modular gas generation solution for GC.

TM8 On-Line Gas Chromatography DGA Monitor Site Preparation Guide Model TMx Series

The. «Modular Alliance» Gas Generators. ALLIANCE, the partnership that keeps the gas flowing. One step ahead!

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Ultima. X Series Gas Monitor

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Nonrefillable Cylinders

Pneumatic High-Speed Pressure Controller Model CPC3000

MEDICAL EQUIPMENT CATALOG

Technical Information Conducal CLY421

780S Ultra High Purity Series

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

Power Transformer Maintenance. Maintenance Practices & Procedures for Substation Class Distribution Power Transformers

6890 GC Site Preparation

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2. premium version

Pressure Automated Calibration Equipment

High Pressure Breathing Air Compressors

Autocalibration Systems For In Situ Oxygen Analyzers

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

Micro Motion 7812 Fiscal Gas Density Meter

Digital deadweight tester Model CPD8500

OXYBABY - MOBILE HAND HELD GAS ANALYSER

ISO INTERNATIONAL STANDARD

EnCal 3000 Gas Chromatograph Commissioning and Maintenance Manual Biogas and THT-Devices

BUBBLER CONTROL SYSTEM

HumiSys HF High Flow RH Generator

Discovery TGA 55, TGA 550, TGA Site Preparation Guide

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Portable Oxygen Concentrator. Give your patients more freedom with mobile oxygen on demand

The New PHD 4 Portable Helium Detector

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

TM8 On-Line Gas Chromatography DGA Monitor Operation & Maintenance Guide Model TMx Series

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

628 Differential Pressure Decay Leak Tester

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user.

CalCheck. Instrument User Manual V1.8

VT650. Gas Flow Analyzer. Technical data. Key benefits and features:

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

Industrial pressure controller Model CPC4000

Varian 240-MS GC/MS Ion Trap Mass Spectrometer Pre-installation Instructions

Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

CAPITAL CONTROLS SERIES NXT3000

Dräger Mine Refuge Chamber MRC 5000 Innovative, portable life support system

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

VT900. Gas Flow Analyzer. Technical data. Key benefits and features:

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

Transcription:

Portable Gas Analyzers

Accuracy Matters To make informed decisions on site, you need fast and reliable data. Myrkos portable gas analyzers provide lab quality DGA data. Where you need it, when you need it: In remote locations or whenever on-site diagnosis is required To confirm monitoring data When frequent oil testing is required on aging transformers Myrkos is the most accurate portable gas analyzer on the market: Lowest detection limits Proven gas chromatography (GC) technology Minimizes human error in sampling, extraction and measurement Built-in diagnostics and solubility coefficients Interference-free measurement of 9 gases in all common oil types Extraction and gas measurement technologies recognized by ASTM 3612 Method C and IEC 60567 standards Standard Warranty PPMreport Software Myrkos portable gas analyzers include PPMreport software, which transforms DGA results into useful transformer diagnoses, generates DGA reports in PDF format and exports data to Morgan Schaffer s advanced diagnostic software, Inside View.

Speed and Ease of Use Matter Accurate results in just 2 minutes Everything you need in one convenient carrying case On-screen oil sampling and gas extraction instructions Single syringe used for sampling, gas extraction and gas measurement Daily calibration 7-hour battery life Myrkos Field Package Easy portability, set-up and operation Maximizes operator productivity 7 hours of cordless operation Over 40 hours of operation between carrier gas refills Flexible data management and analysis using on-board controller (included) Myrkos Lab Package Lab quality results Maximizes throughput of laboratory DGA analyses Enables laboratories to optimize resources and minimize cost per sample Integrates easily into any laboratory QMS and standard procedures

We did it first. We still do it best. More than 50 years of DGA expertise. Cost Reduction Also Matters Myrkos portable gas analyzers are an effective cost reduction tool: Confirm the presence of faults in the event of a monitor alarm Minimize downtime on false alarms Optimize maintenance schedules Monitor condition of transformers known to have faults Diagnose critical equipment during re-energizing or commissioning Allow cost-effective diagnosis of smaller transformers Inside View diagnostic software Inside View, the most comprehensive DGA and dielectric oil diagnostic software on the market, integrates data from any brand of online monitor or portable analyzer and oil testing lab. Centralize data for fast and easy accessibility Perform accurate oil test data interpretation Deploy a configurable health index Receive only necessary alerts

DGA Accuracy. Where you need it. When you need it.

Accuracy in everything we do. Morgan Schaffer s commitment is not limited to our equipment. We also ensure excellence in all of our activities: On-time delivery Superior technical support Responsiveness and customer service Repair services Quality assurance across the board For more information about Calisto online DGA monitors or to request a demo unit, please contact us at: Head Office Morgan Schaffer USA 8300 Saint Patrick Street Suite 150 LaSalle, Quebec, Canada H8N 2H1 Tel: 1.514.739.1967 Toll-Free: 1.855.861.1967 Fax: 1.514.739.0434 E-mail: sales@morganschaffer.com 101 Henderson Drive Sharon Hill, Pennsylvania, USA 19079 Tel: 1.215.279.5915 Toll-Free: 1.855.861.1967 E-mail: sales@morganschaffer.com Accreditations Morgan Schaffer is ISO/IEC 17025:2005 accredited in Canada by the Canadian Standards Council for the tests listed on its scope of accreditation. Morgan Schaffer USA accreditation is forthcoming. Morgan Schaffer is ISO 9001:2008 certified. 2015 Morgan Schaffer Inc. All rights reserved. The Morgan Schaffer logo is a trademark of Morgan Schaffer Inc. www.morganschaffer.com

PORTABLE GAS ANALYZER Technical Specifications Myrkos Instrument Performance Measurement technology Dual-channel gas chromatograph Micro-machined injectors and TCD detectors Shake Test sampling and gas extraction 1 Gases measured H 2 (hydrogen) CH 4 (methane) C 2 H 6 (ethane) C 2 H 4 (ethylene) C 2 H 2 (acetylene) CO (carbon monoxide) (carbon dioxide) O 2 (oxygen) N 2 (nitrogen) Gas-in-oil* measurement range H 2 : 5-60,000 ppm Other fault gases: 1-60,000 ppm O 2 : 60-100,000 ppm N 2 : 500-100,000 ppm Gas-in-oiI* repeatabiiity 2 H 2 : greater of ±2 ppm or ±2% : greater of ±10 ppm or ±2% Other fault gases: greater of ±2 ppm or ± 2% O 2 : ±60 ppm or ±2% N 2 : ±500 ppm or ±2% Gas-in-oil* accuracy 3 H 2 : greater of ±5 ppm or ±6% : greater of ±10 ppm or ±6% Other fault gases: greater of ±2 ppm or ±6% O 2 : ±60 ppm or ±6% N 2 : ±500 ppm or ±6% *Gas-in-oil specifications encompass instrument-to-instrument, syringe-to-syringe and gas extraction method uncertainties. Resolution Measurement time Calibration Sampling Sample integrity Gas filtering Communication and Data Connectivity All gases: 1 ppm 2 minutes Morgan Schaffer CALGAS with NIST traceability 100 ml Shake Test syringe for oil samples 10 ml glass syringe for gas samples from relay, tank or PTFE membrane Room temperature injection Used as directed, individual syringes ensure no gas loss and no cross-contamination Automatic line purging with internal sampling pump Disposable oil traps (5 μm) Replaceable particle trap (10 μm) Direct or networked TCP/IP Ethernet Interface software Morgan Schaffer PPMreport TM (Windows XP / Vista / Windows 7 / Windows 8 / Windows 10) provides instrument control, data acquisition, data management, DGA diagnostic tools and customizable PDF reports. DGA data management and diagnostics Inside View diagnostic software integrates DGA data from monitors and portable analyzers with laboratory oil quality data. Diagnostic tools for fleetwide transformer health management (sold separately).

Operation Power supply Gas requirements Operating temperature range (standard) 0 to 50 C Storage temperature range 0 to 75 C Humidity range Elevation range Cooling Maintenance Expected operating life Construction Width x Height x Depth Weight Enclosure Ruggedness Conformities Directives In-line power adaptor with IEC 60320/Cl 4 receptacle / Power supply Input: 100-240 VAC, 50/60 Hz, 100 W, 1Ø / Output: 24 VDC, 6.2 A 8 ft power cord with IEC 60320/Cl 3 to NEMA 5-l 5P 99.999% He, 80 psig 5-95% RH non-condensing Up to 4,500 m (15,000 ft) Forced air convection Annual visual inspection 10 years 250 x 155 x 420 mm (9.8 x 6.1 x 16.5 in.) 10 kg / 22 lbs Cast aluminum frame, aluminum covers, powder coat paint, carrying handle Drop-tested to 1 m Low Voltage Directive 2006/95/EC Directives EMC Directive 2004/108/EC CE Marking Safety IEC / EN 61010-1: 2001 EMC rating IEC 61326-1: 2005 / EN 61326-1: 2006 CISPR 11: 2003 / EN 55011: 1998 + A1: 1999 + A2: 2002 Standard Package Myrkos Analyzer Myrkos Calibration Kit Myrkos Oil Sampling Kit Myrkos Squirt Method Kit Other Accessories Warranty Myrkos Portable DGA Analyzer PPMreport TM interface software, certificate, user manual Gas-tight glass syringe (10 cc) NIST traceable CALGAS cylinder (500 cc) Micro-flow regulator with dial gauge trap for air run Shake Test syringe (100 cc) Myrkos Oil Sampling Kit bag of oil traps (25/bag) trap for Shake Test Squirt stopper Squirt tube Shake Test syringe holder Tool and connection kits Morgan Schaffer s Myrkos analyzer is backed by a 30-month standard warranty. Service and Support On-site commissioning assistance and on-site maintenance program available upon request. Notes 1 - The Shake Test Method is a variation of ASTM D3612-02 Method C and is also described in the international standard IEC 60567. 2-95% confidence interval 3-95% confidence interval in comparison with Morgan Schaffer s ISO/IEC 17025 accredited laboratory. Product improvements since the writing of IEC 60567: 2005 have led to the improved accuracy specifications provided here. Continuing research and improvements may result in specification or appearance changes at any time. www.morganschaffer.com 2015 Morgan Schaffer Inc. All rights reserved. The MS Morgan Schaffer logo is a trademark of Morgan Schaffer Inc. Myrkos_Inst_Spec_EN2015

PORTABLE GAS ANALYZER Technical Specifications Field Package Standard Field Package (in addition to the Myrkos Instrument) Carrying case Li-ion rechargeable battery Made of high-performance HDPE Press and pull latches, padlockable Rugged in-line wheels and telescopic handle Rain, immersion and vibration proof 795 x 518 x 310 mm (31.3 x 20.4 x 12.2 in.) 24 VDC operation 7 hours autonomy 1.4 kg (3.1 lbs) Cycle life > 300 cycles LCD state of charge indicator Includes a charge control module with a universal power adaptor Includes the battery to Myrkos power cable Miniature portable controller Carrier gas module (helium 99.999% min.) Shake Test syringe carrying case (for 2) Shake Test syringe carrying case (for 6) 10.1 in. screen size 6-cell Li-ion battery, 10.5 hours autonomy Preloaded with PPMreport TM, support documentation and instrument method file Back-up files provided on SD card 1.5-foot RJ45 crossover patch cable 42 hours of helium autonomy Built-in quick-connect port for O 2 -N 2 measurements Removable for easy off-site refill Holds 2 fully-extended Shake Test syringes Fits inside the Myrkos carrying case Includes the squirt kit and one trap Holds 6 fully-extended Shake Test syringes Protects syringes against damage High-pressure filling line Connection kit to refill the carrier gas module (with CGA 580) Safety relief valve preset to 1,800 psig Other accessories Operation Set-up Instrument protection Weight Shake Test syringe holder support 5 additional Shake Test syringes 3 additional oil trap bags (25/bag) Set-up and operation guide Intuitive and ergonomic design Large plateau for convenient operation using miniature portable controller Includes a lid stay to prevent unintended closing during operation Manual reset over-temperature protection 27.8 kg (61.5 lbs)

PORTABLE GAS ANALYZER Technical Specifications Standard Lab Package (in addition to the Myrkos Instrument) Syringe shaker Automated Shake Test sample extraction Safe syringe clip-on installation Holds up to 3 Shake Test syringes One-button 2-minute operation with automatic stop 110/220 VAC 50/60 Hz 0 2 -N 2 measurement bench top kit Built-in ergonomic extraction gas port with shut-off valve 4-ft ⅛ in. copper connection line with brass tee Lab Package Shake Test syringe carrying case (for 6) Two-stage helium pressure regulator Holds 6 fully extended Shake Test syringes Protects the syringes against damage CGA 580 connection High-pressure output stability (preset to 80 psig) 4-ft ⅛ in. copper connection line with one-way valve Other accessories Options and Accessories Shake Test syringe 5 additional Shake Test syringes 3 additional oil trap bags (25/bag) Method compliant with ASTM D3612-02 and described in IEC 60567 standard 100 cc, individually serialized 12 VDC/120 VAC vehicle inverter Pure sine, 300 W connects to standard vehicle 12 VDC source On-site training session 1-day on-site training session provided by Morgan Schaffer qualified personnel Extended warranty Consumables Spare Parts Extended warranties from 3 to 5 years available NIST traceable CALGAS cylinder (500 cc), suitable for 200 calibrations Bag of oil traps (25/bag) Li-ion rechargeable battery (Field Package only) Support for the Shake Test syringe holder (Field Package only) Battery charger w/universal AC adaptor (Field Package only) Gas-tight glass syringe (10 cc) trap for air run trap for Shake Test 3-way valve stopcock (20/bag) Head Office 8300 Saint-Patrick Street, Suite 150 LaSalle, Quebec, Canada H8N 2H1 Tel: 1.514.739.1967 Toll-Free: 1.855.861.1967 Fax: +1 514.739.0434 E-mail: sales@morganschaffer.com Morgan Schaffer USA 101 Henderson Drive Sharon Hill, Pennsylvania, USA 19079 Tel: 1.215.279.5915 Toll-Free: 1.855.861.1967 E-mail: sales@morganschaffer.com Accreditation Morgan Schaffer is ISO/IEC 17025:2005 accredited by the Standards Council of Canada for the tests listed on the scope of accreditation. Morgan Schaffer USA accreditation is forthcoming. Morgan Schaffer is certified ISO 9001:2008 www.morganschaffer.com 2015 Morgan Schaffer Inc. All rights reserved. The MS Morgan Schaffer logo is a trademark of Morgan Schaffer Inc. Myrkos_Field-Lab_Spec_EN2015