Intrinsic safety 101 hazardous locations

Similar documents
1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

Session #: Selection of Explosion Protected Equipment for Hazardous Locations

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres

NZQA registered unit standard version 3 Page 1 of 6

Explosion Protection Technology Pty Ltd

Electrical Equipment and Installations in Hazardous Areas. Univerza v Ljubljani Fakulteta za elektrotehniko

IE073: Intrinsic Safety, Galvanic Isolation and Zener Barriers Technology & Applications

IECEx OPERATIONAL DOCUMENT

Understanding safety life cycles

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus

The Software. Hazardous distance

RTD temperature probes

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Dangerous Substances & Explosive Atmospheres Regulation 2002 The Basics. Richard Cowen Dip SH, Dip RSA, CMIOSH, MIIRSM, FRSPH, GI Fire E

Explosion Protection Technology Pty Ltd

A Unified Marking System for Ex Equipment

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS

TECHNOLOGY GUIDE NO. 12

ENGINEERING STANDARD FOR HAZARDOUS AREA SECOND EDITION JANUARY 2016

TechNote FM APPROVAL: HAZARDOUS LOCATION EQUIPMENT CLASSIFICATION

WHITEPAPER: ATEX IN PRACTICE (EXPLOSION PROTECTION)

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Hazardous (Classified) Locations

Safe Work Practices / Procedures / Instruction CONFINED SPACE

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

A study on the relation between safety analysis process and system engineering process of train control system

Rockhampton Office Brisbane Office Tarong Site. Barron Gorge Hydro PS Kareeya Hydro PS Mica Creek PS

II 2G EEx ia IIC T6. Ignition protection class

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Hot Work Program. University of Wisconsin-Platteville Reviewed 4/2016

Wireless I/O, Connecting Remote Sensors in a Wide Range of Environments

CERTIFICATE OF COMPLIANCE

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities.

NZQA unit standard 7145 version 9 Page 1 of 5. Design and maintain effective ventilation systems for an underground coal mine

Describe Flammable Gas Measurement

Hafner-Pneumatik presents: General information on ATEX 95 & Products for explosion hazardous environment from the Hafner range

Instruction Manual for Intrinsically Safe - Reed Switches

Pressure switch KP-E. Data sheet

AIDGC PRESENTATION MARCH 2006 HAZARDOUS AREAS STANDARDS & CLASSIFICATION

The Best Use of Lockout/Tagout and Control Reliable Circuits

LOCKOUT/TAGOUT PROGRAM

NZQA unit standard version 3 Page 1 of 8. Manage the mine ventilation system at an extractive site

FLAMMABLE & COMBUSTIBLE LIQUIDS PROGRAM

Certificate of Compliance

Protocol for Confined Space Entry Requirements

Recognition, Evaluation, and Control of Hazards

THE PETROLEUM INDUSTRY Code of Practice

CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS IN GAS UTILITY AREAS. Gerry Pickens

BASIC NATIONAL ELECTRIC CODE APPLICABLE TO MEASUREMENT. Gerry Pickens. Atmos Energy 810 Crescent Centre Drive Franklin, TN 37067

Key Technology, Inc. Confined Space Entry Program. July, 2017

The Omron STI Hazardous Location

TABLE OF CONTENTS PART 2 - CONFINED SPACES

INOGATE Technical Secretariat UK Experience European Standards Implementation Key Expert Phil Winnard Session 2 Georgia, October 2015

Inductive slot sensor

Pioneers. Ex-ENGINEERING. Quality

Flammable Environments Guideline

Preventive Maintenance

flammable dust II 1D or II 1/2D or II 1/3D Level measuring devices and silo equipment for the potentially explosive atmospheres

NZQA unit standard New US 1Non-coal of 7145 version 1 Page 1 of 5

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

SOP. Working in Confined Spaces

PROCEDURE FOR INITIAL AND PERIODIC INSPECTION POTENTIALLY EXPLOSIVE ATMOSPHERES (HAZARDOUS AREA) ORIGINAL EDITION

NZQA unit standard version 5 Page 1 of 5. Describe, develop, and maintain basic ventilation systems for an underground coal mine

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

COLD-WEATHER APPLICATION OF GAS MIXTURE (SF 6 /N 2, SF 6 /CF 4 ) CIRCUIT BREAKERS: A UTILITY USER S PERSPECTIVE SUMMARY

Technical Data. Dimensions

Operating Instructions

Implementation of Electrical and Instrument Installation in Hazardous Area Classification

Design Guideline Planning fieldbus segments in safe and hazardous areas

Explosive Environment Review

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

SAFETY MANAGEMENT MANUAL Confined Space Entry

Material Safety Data Sheet

Installation of Ballast Water Management Systems

Technical Data. Dimensions

Wired Communication in Confined Space

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

FUEL TANK SAFETY / EWIS CONTINUATION TRAINING

Tool Box Talk. Confined Space Entry New Construction Standard (2015)

"CONFINED SPACE ENTRY"

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

HSE guidelines. SMay 2015 ELECTRICAL SAFETY HSE LIFE THE NATIONAL OIL&GAS INDUSTRY STANDARD FOR PROFESSIONALS

Innovation Electrical Industry

ATEX and explosive atmospheres

Arc Flash. Safety 21

Arran LED Floodlight Luminaire

SWMS No 009 Samark North Qld Pty Ltd ABN : Electrical Contractors License C37121 Page 2 of 4

"CONFINED SPACE ENTRY... A REFRESHER PROGRAM"

Advances in Low Voltage Motor Control Center (MCC) Technology Help Reduce Arc-Flash Hazards and Minimize Risks

State University of New York College at Oneonta

Pressure Switches Application Guideline

CARRIAGE OF DIRECT REDUCED IRON (DRI) BY SEA CHANGES TO THE IMO CODE OF SAFE PRACTICE FOR SOLID BULK CARGO

Electrical Safety Work Practices

Improve Process Reliability

NZQA Expiring unit standard version 7 Page 1 of 8. Demonstrate knowledge of safe working practices in telecommunications.

Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers TABLE OF CONTENTS

Transcription:

Intrinsic safety 101 hazardous locations Protection methods, containment, segregation, and prevention By Robert Schosker This article answers the question, Why worry about hazardous locations? The area classifications for the U.S. and the European (the International Electrotechnical Commission [IEC] standard) approaches are described and contrasted, including protection methods, containment, segregation, and prevention. What is intrinsic safety? Intrinsic safety (IS) has been around a long time. It is the concept of limiting ignition-capable energy to below that of the hazardous material a process may be working with. IS, as most people call it, was born out of the ashes of a horrible mining accident in the U.K. in 1913. The explosion was caused by a low-voltage signaling system that was used to advise the surface crew that coal cars were ready to be brought to the surface. The ensuing research revealed that the most important factor in determining the safety of an electrical circuit is the energy stored in the circuit. The concept of intrinsic safety was born. So why do we worry about hazardous locations? Many explosions are the result of limited knowledge by employees, which can be directly related to inadequate training, lack of documentation, and questionable safety measures. These disastrous results may have been prevented with proper training, new instrumentation, inspection, maintenance, or revised safety procedures. Of course, even if the plant takes these steps, an explosion could still happen; however, every effort to reduce residual risk is a benefit. Residual risk is the risk left over after all other forms or mechanical means of risk reductions have been taken. A hazardous area is an area containing (or likely to contain) an ignitable concentration of flammable gas, vapor, or dust, where an electrical spark of sufficient power will cause an explosion. However, an explosion can only occur when an oxidizer, the hazardous substance (gas, vapor, or dust), and energy (thermal or electrical) are present at the same time. These three groups comprise what is known as the hazardous location ignition triangle. If any one of these groups is removed, an explosion cannot happen. As we will discuss throughout this article, intrinsic safety is a method of protection that removes one of these groups from the ignition triangle. The article will first answer some basic questions about hazardous locations. We already know why we worry, but what are we worrying about? What is a hazardous location? What or who defines a hazardous location? What is the difference between zones and divisions? These are all very good questions, and ones that are often asked. We already know that a hazardous location is an area that contains or is likely to contain an ignitable concentration of flammable

gas, vapor, or dust. Once we have determined that a hazardous area exists, then we classify that area using either zones or divisions. Although the physical principles of explosion protection are the same worldwide and are not differentiated, the procedures determined by national legislation in the approximately 100-year history of explosion protection have resulted in various solutions. Each solution has a unique perspective on how to classify a hazardous area. Divisions, mainly a North American approved method of classifying an area, use four categories: class, division, group, and temperature. They are commonly seen like this: The categorization of these areas is carried out in North America in accordance with the National Electrical Code NFPA 70, article 500. Class I, II, or III represent the form of the hazardous material you must deal with. Division is a categorization by the probability that these materials will be present in a potentially hazardous quantity (Division 1 and Division 2). The division is commonly the perimeter or designated area of the hazardous material.

Furthermore, classes of hazardous areas are divided into subgroups depending on the type of flammable gas or vapor present. Finally, apparatus installed directly in a hazardous area must be classified for the maximum surface temperature that the device will produce under normal operation or in the event of a fault. The maximum surface temperature must be below the minimum ignition temperature of the gas present.

The graphical representation below illustrates the concept of division-based areas. In Europe, the zone method of area classification is used. The European zone practice is described in IEC/EN 60079-10. In accordance with this standard, any area where there is a probability that flammable gas or dispersed dust may exist must be classified into one of the following areas:

The European zones then require that the apparatus be subdivided into two groups, according to IEC/EN 60079-0. These two groups in general terms indicate whether the apparatus is located above or below ground. And as with divisions and gas groups, there are subgroups of Group I and II within the zones. Each is associated with a certain number of gases having an ignition energy in the value reported and is represented by the gas referenced in the table below. Included in this comparison are the Class I and II division-based classifications.

A temperature code is also required just like divisions; however, the zone method is simplified. With both divisions and zones, the maximum surface temperature must be below the minimum ignition temperature of the gas present. The graphical representation illustrates the concept of zone-based areas. The article has explained hazardous areas and how those areas are classified, but what methods of protection exist for your hazardous areas? As previously mentioned, to reduce the risk of explosion, you must eliminate one or more of the components of the ignition triangle. There are three basic methods of protection: explosion containment, segregation, and prevention.

Explosion containment: the only method that allows the explosion to occur, but confines it to a well-defined area, thus avoiding the propagation to the surrounding atmosphere. Flameproof and explosion-proof enclosures are based on this method. Segregation: a method that attempts to physically separate or isolate the electrical parts or hot surfaces from the explosive mixture. This method includes various techniques, such as pressurization and encapsulation. Prevention: a method that limits the energy, both electrical and thermal, to safe levels under both normal operation and fault conditions. Intrinsic safety is the most representative technique of this method. The protection methods, based on the containment and segregation concepts, are methods that contain the explosion in order to prevent the energy source electrical or thermal from coming in contact with the potentially explosive mixture. In both cases, the use of appropriate enclosures and specific wiring and installation systems is required. The intrinsic safety method prevents the ignition of the explosive atmosphere, while simplifying the installation and use of the required apparatus that is connected to the electrical circuits directly located in a hazardous location. The choice of a specific protection method depends on the degree of safety needed for the type of hazardous area. The idea is to determine the best protection method based on the lowest probable degree of the simultaneous presence of an adequate energy source and a dangerous concentration level of an air/gas mixture. Of course, other important factors to consider include the size of the apparatus to be protected, the flexibility of the system, the possibility of needing to perform maintenance, and the installation cost. Respective of these factors, intrinsic safety has many advantages. So what is intrinsic safety? Intrinsic safety is based on the principle of limiting energy to a level below that required to ignite the hazardous gas or dust. The energy limitation also pertains to thermal energy as well. Therefore, in normal operation or in the event of a fault, no sparks or thermal effects may occur that could lead to the ignition of a potentially explosive atmosphere. It is one thing to understand intrinsic safety as a concept, but it has to be applied correctly to work. As shown in the illustration, there are three components to an intrinsically safe circuit:

The field device intrinsically safe equipment located in the hazardous location Intrinsically safe barrier or associated apparatus located in nonhazardous location Interconnecting wire between the two apparatus The example here is simple, because the fault combinations are few, and the knowledge of the apparatus safety parameters and cable characteristics are sufficient to verify the safety of the system. A more complex system (combinations of barriers or using multiple cables) requires a more detailed analysis because there are many fault combinations to verify, and they are not always evident. As mentioned above, more complex analysis may be required with intrinsic safety, but with this in mind, intrinsic safety has several advantages over the other methods of protection. They include allowing trained personnel to connect and disconnect circuits under live operation. They are guaranteed to be safe during short circuits or lead breakage. Intrinsic safety is the only ignition protection class that allows connectors to be opened and intrinsically safe apparatus to be removed and replaced by an equivalent device in a hazardous area. Intrinsic safety is also the only method that allows general-purpose wiring methods to be used in the hazardous area. These simple advantages also generate cost savings through installation and maintenance, because this method allows live maintenance with no need for plant shutdown. Intrinsic safety is also more reliable due to the use of infallible and derated components as prescribed by the standards. Intrinsic safety was born from the ashes of a horrific accident to become the most widely accepted method of protection. Not only does it limit voltage and current, but it provides a 50 percent safety margin even during fault conditions; no other method of protection can claim that. In the end, it is the end users who must determine the area of classification, the required process equipment, and the method of protection they want to use. If they decide to use intrinsic safety, I think they will find that it provides the best mix of an affordable system and the safety required. ABOUT THE AUTHOR Robert Schosker is the product manager for intrinsic safety, HART, signal conditioners, and surge protection for Pepperl+Fuchs. Since joining Pepperl+Fuchs in 1995, he has been focused on technology and productrelated support, and is involved in a wide range of activities and roles including certifications, sales, and marketing. He has been the key lead in many IS and HART projects resulting in the development of new products for intrinsic safety and HART infrastructure. Schosker holds a BSEE from the University of Akron. Direct questions or comments to pa-info@us.pepperl-fuchs.com.

Source: http://www.isa.org/intechtemplate.cfm?section=control_fundamentals1&template=/contentmanage ment/contentdisplay.cfm&contentid=94304