K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

Similar documents
K16.10 EDGE DOOR HANDLES K16 DOORS

H11.13 PIVOTS SERIES 490 H11 HORIZONTAL AND VERTICAL PIVOT WINDOWS

OCEAN - Wellness Line

F13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS

Tapped Hole (.375) Tapped hole 15 (.594) (.391±.004) Frame 19±0.2 (.750±.008) 12.7±0.2 (.500±.008) 19±0.2 (.750±.008) R S 4 x Ø 5.4 (.

Technical information for hinges

Aluminium & Stainless Steel

PRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M

PRODUCT CARD WALL MOUNTED FIXED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,00 TO 2,25 M

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

DOUBLE SAFETY: NO PANIC, NO BACTERIA

Lever handles and door knobs for framed doors

HLS TM 7 Series* Multipoint Hardware System. Edition 2

HLS 9000 Swing Door Handle Edition 4

DICTATOR "DIREKT" Gate Closer

hockey hockey Integral Weighted Goals Aluminium Goals Fence Folding Goals Premier Hockey Goals Folding Wheelaway Goals

Product: Aluminium Door Edge Guard

Salice 4100 Tower Bolt

Product: Aluminium Door Edge Guard

Kestrel Aluminium Systems Limited. Product Manual Section 10 Thermal Framing System. Manual Version

PCB accessories. PCB handle C. PCB retainer C. Order Information. Note. Order Information

FLUID - Panic Exit Device

Lock Descriptions. Cost Categories. Suitability

DICTATOR "DIREKT" Gate Closer

Aluminium. Overview. Door stops. Pull handles. Cabinet knobs. Card frames. Cable box. Numerals. Indicators. Budget lock roses.

Slide and Turn System SF25

These instructions are to be left with the user

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions

DEADBOLT SETS, MECHANICAL FEATURES

Installation Guide Wall Mounted Angled Flagpole

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Pneumatic spool valve islands

ALUMINIUM TANK AND COMPENSATOR - SERIES 09

FIRST TEAM SPORTS, INC Storm Portable Series Assembly Instructions

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

10.2. Basketball Single Post System

Retractable Security Cover for a Swim Spa

Dear Tennis friends. Furthermore we offer: fair prices reliable delivery times technical know-how high product quality

10.2. Basketball Single Post System

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted.

Order No Projection Backboard

Fire- & smoke- tight sliding door FST High quality for demanding architecture

02 Push-to-Close Latch

SERIES A24 RAISED RIB

Hydraulic Punch Drivers

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

3b Technical information

8MAY15 US RACK, Inc Falcon Drive, Madera, CA

Extension Platform. Base Platform. Crossover. Exit railing. Exit Railing

The M-UPPT is an universal punch tool. Different punch inserts can be easily switched out. Pin to fix and remove inserts

DEADLATCHES LK-2100 SERIES ASSEMBLY DETAILS LK R-RH

HARDWARE. Push / Pulls... A Pivots... A Hinges, Locks and Cylinders... A Handles, Locks and Accessories... A4...

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

A. TO PREPARE THE MACHINE FOR USE.

INDUSTRIAL HOSE REEL suitable also for out-door workplaces. Made in Italy

3M Telecommunications Solutions for Networks. Quante QSA (= LSA plus) System Catalogue. Innovation

Encore PE 50-lb Feed Hopper

Aluminium Stainless steel

Pneumatic valve islands

GACELA roller runners

NHR-X-X Encore Feed Hoppers

Freshware have a comprehensive range of products for window

The CompacSas BAH airlock is the ideal solution for transforming an existing door into an airlock

MultiWoody design Mario Cucinella

Bike-Shell Model 301P

Straightaway 130. Sliding & Folding Door Systems. Product Overview. Features. Technical Specifications. Coburn Product Data Sheet

WELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Skylight Rollers For Velux windows

CFSW. Hinges with built-in safety multiple switch

Slide and Turn System SF35

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

door fittings >> Make any door look special with Croft fittings. Lever Furniture

Simple, handleless, good: Push to open for hinges

NHR Powder Feed Hopper


Telescopic winch handle Speedfriend"

SLAT & LOUVRE FENCING

SHEET 2: VERTICAL INSTALLATION

SERIES E30 RAISED RIB

DETAILS. Finishing: metal frame: epoxy powder coating RAL 7016 dark-grey or RAL 9006 silver-grey rails-clamps-wheels-bolts: galvanised material

Flagpole Selection Guide

3M InCa Individual Cross-Connection Cabinets

BOAT WINDOWS AND SHOWERS Price List June 2017 Tel/Fax:

Horizontal Bladder Tanks

UniSas BA. Physical single-person detection. Models: UniSas BA9, UniSas BA12. Energy savings. Eco-design. Recyclable product. Manual Attack Resistance

CamRT Sun Top Bimini Installation Instructions

Hoist Ring Forged Hoist Ring Machined Hoist Ring (Metric) Hoist Ring Swivel Shoulder Eyebolts JD Weld-On Alloy Lifting

Vertical Bladder Tanks

Adjustable Broaching Head 3. Fixed Braoching Heads 4. Broaching Bits Hexagonal 5. Broaching Bits Square 6. Broaching Bits Torx 7

Operating & Maintenance MANUAL

Keel-stepped and deck-stepped masts,

Technical Datasheet. Rigid & Retractable Pendants. Rigid Pendant

Crosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

3190A NEO-ANGLE DOOR INSTALLATION INSTRUCTIONS. Series MODEL NO

CLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division

REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID

INSTALLATION INSTRUCTIONS

BREATHERS VE Series. The best-selling traditional breather type, with hydraulic valve.

Transcription:

K13 DOORS K13.12 FACE FIXED PANIC EXIT DEVICE 01.03.2018 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com

CONTENTS 1. Base set n 5701-1... K13.12.03 2. Additional locking sets n 5701-3 and n 5701-3B... K13.12.04 3. Door handles... K13.12.05 3.1. Door handle n 5701-20 K13.12.05 3.2. Turn knob n 5701-21 K13.12.05 3.3. Door handle n 82000-26 K13.12.05 3.4. Square spindles K13.12.06 4. Accessories... K13.12.07 4.1. Push bar n 5701-... K13.12.07 4.2. Cylinders K13.12.07 4.3. Keeps K13.12.08 4.4. Additional connection rod n 5701-4 K13.12.09 4.5. Set cover sections n 5701-7 for additional set K13.12.10 5. Combinations... K13.12.11 6. Installation instructions... K13.12.12 6.1. Assembly K13.12.12 6.2. Assembling order K13.12.13 6.3. Profile preparations K13.12.14 6.4. Detail bottom keep K13.12.16 6.5. General notes and instructions K13.12.16 K13.12.02

1. Base set n 5701-1 General characteristics Base set for profile cylinder, steel zinc plated, to be mounted on the inside of the door. The panic exit device is CE marked in accordance with the European standard EN 1125:2008. Code 377B1322AA. Covers steel coated. The base set is available in 3 colours: white, grey or black coated, to specify when ordering. Other RAL colours on request. Latch, steel nickel plated. The latch at the hinge side of the door is pushed inside and covered when mounting the set. Therefore the set can be used for left hand as well as for right hand doors. See drawing below. Operating devices The lock can be operated on the outside by a door handle: see page K13.12.05. Note: when operating the panic exit device with locked door, the door will still be locked after closing. The base set cannot be used with cylinder on the inside. Operation on the outside by a door handle with or without half cylinder. Dimensions K13.12.03

2. Additional locking sets n 5701-3 and n 5701-3B Vertical rods with latch bolts for additional top and bottom locking points. N 5701-3: with top and bottom latch bolts. N 5701-3B: with lateral latch bolts. The set contains: 1x top locking device 1x bottom locking device 2x connection rod 2x keep 5x guiding piece screws and accessories Rods and covers steel coated. Latches steel nickel plated. The set is available in 3 colours: white, grey or black coated, to specify when ordering. Other RAL colours on request. Axis of push bar Axis of push bar n 5701-3 n 5701-3B Guiding pieces: The guiding pieces are mounted with a maximum spacing of 300 mm. See drawing on the right hand side. K13.12.04

3. Door handles 3.1. Door handle n 5701-20 K13.12 Handle with long backplate to be mounted on the outside of the door. Finish: Door handle n 5701-20: base in zinc alloy, cover plate and grip in aluminium, anodised or polyester powder coated in more than 450 RAL colours. Door handle n 5701-20 (in stainless steel): base in zinc alloy, cover plate and grip in stainless steel. 3.2. Turn knob n 5701-21 Turn knob with long backplate on the outside. Finish: similar to door handle n 5701-20. 3.3. Door handle n 82000 Door handle with spring on short backplate on the outside. Due to the aluminium cover the fixing screws are always concealed. Finish: polyester powder coated in more than 450 RAL colours. The square spindle of 8 mm, steel zinc plated must be ordered separately. K13.12.05

3.4. Square spindles The square spindles of 8 mm must be ordered separately. Door handle n 5701-20 Turn knob n 5701-21 Door handle n 82000 Profile depth Profile depth Profile depth Spindle length Order code 35 to 45 mm 115 V48-115 45 to 55 mm 125 V48-125 55 to 65 mm 135 V48-135 60 to 70 mm 140 V48-140 70 to 80 mm 150 V48-150 80 to 90 mm 160 V48-160 90 to 100 mm 170 V48-170 Profile depth Spindle length Order code 35 to 45 mm 115 V18-115 45 to 55 mm 125 V18-125 55 to 65 mm 135 V18-135 65 to 75 mm 145 V18-145 75 to 85 mm 155 V18-155 85 to 95 mm 165 V18-165 90 to 100 mm 170 V18-170 Notes: The square spindles of handles 5701-.. are provided with a slot and are fixed by a grub screw in the slotted part of the spindle. All square spindles are also available in large scalement package (G) per 50 pieces. Ordering example: GV48-115. K13.12.06

4. Accessories 4.1. Push bar n 5701-... Available in different lengths. Types: Steel, white or black coated, to specify when ordering. Other RAL colours on request. Aluminium, grey anodised. Stainless steel. When ordering please add the characters INOX to the order code. Order code Length L (mm) 5701-1000 1000 5701-1200 1200 5701-1500 1500 4.2. Cylinders Half cylinder n 880-10-.. for control from the outside. 0 or 9 mm D = Profile depth With door handle n 5701-.. D (mm) A (mm) B (mm) Order code 45-50 80 70 880-10-70 50-55 85 75 880-10-75 55-60 90 80 880-10-80 60-65 95 85 880-10-85 65-70 100 90 880-10-90 70-75 105 95 880-10-95 75-80 110 100 880-10-100 80-85 115 105 880-10-105 With door handle n 82000 D (mm) A (mm) B (mm) Order code 54-59 80 70 880-10-70 59-64 85 75 880-10-75 64-69 90 80 880-10-80 69-74 95 85 880-10-85 74-79 100 90 880-10-90 79-84 105 95 880-10-95 84-89 110 100 880-10-100 89-94 115 105 880-10-105 K13.12.07

4.3. Keeps Side and top keep n 5701-9 Keep in zinc alloy with cover in synthetic material. The set contains the fixing screws for both installation on aluminium as on PVC profiles. The keep is included in the base set n 5701-1 and the additional set n 5701-3(B). Installation on aluminium Installation on PVC The keep is reversible in accordance with the depth difference of the profiles (dimension 12.2 mm or 8.9 mm). Flush profiles Rebated profiles Bottom keep n 5701-8 Keep in zinc alloy with cover in stainless steel. The keep is mounted on the floor or the sill. The keep is included in the additional set n 5701-3. K13.12.08

Keeps for PVC profiles Keeps in stainless steel. The keep can be mounted at the side or at the top. N 5701-5 For a depth difference between frame and vent section of 15 to 17 mm. The keep is supplied with 4 packers, 1 mm thick. Depth difference = 15 mm : 4 packers Depth difference = 16 mm : 2 packers Depth difference = 17 mm : 0 packers N 5701-5B and 5C For a depth difference between frame and vent section of 19 and 21 mm. n 5701-5B n 5701-5C 4.4. Additional connection rod n 5701-4 Additional connection rod for doors with vent height over 2650 mm. Maximum vent height 3600 mm. The connection rod, in steel coated, is connected to the top rod of set n 5701-3 or n 5701-3B. The guiding piece is included in the set. The set is available in 3 colours: white, grey or black coated, to specify when ordering. Other RAL colours on request. K13.12.09

4.5. Set cover sections n 5701-7 for additional set The upper cover section must be shortened in accordance with the door height. The set is available in 3 colours: white, grey or black coated, to specify when ordering. Other RAL colours on request. Note: Not possible with the additional connection rod n 5701-4 Front view Side view K13.12.10

5. Combinations Single doors n 1 n 2 n 3 n 4 n 5 n 6 n 7 n 8 n 9 Double doors n 4 n 1 n 4 n 2 n 4 n 3 n 4 n 7 n 4 n 8 n 4 n 9 Notes: Do not use the additional locking set n 5701-3B on the second leaf of double doors. The mechanism can not be operated with only a cylinder on the outside! N 1 : base set n 5701-1 without control from the outside N 2 : base set n 5701-1 + handle outside n 5701-.. or n 82000-26 N 3 : base set n 5701-1 + handle outside n 5701-.. or n 82000-26 + half cylinder outside n 880-.. N 4 : base set n 5701-1 without control from the outside + additional locking set n 5701-3 N 5 : base set n 5701-1 + additional locking set n 5701-3 + handle outside n 5701-.. or n 82000-26 N 6 : base set n 5701-1 + additional locking set n 5701-3 + handle outside n 5701-.. or n 82000-26 + half cylinder outside n 880-.. N 7 : base set n 5701-1 without control from the outside + additional locking set n 5701-3B N 8 : base set n 5701-1 + additional locking set n 5701-3B + handle outside n 5701-.. or n 82000-26 N 9 : base set n 5701-1 + additional locking set n 5701-3B + handle outside n 5701-.. or n 82000-26 + half cylinder outside n 880-.. K13.12.11

6. Installation instructions 6.1. Assembly Notes: 5a 5 6a The set can be used left hand as well as right hand, simply by covering the latch at the hinge side with a plastic cover (1c). If the set is used with a set of vertical rods, the plastic clip at top of the steel cover must be removed to slide in the rod. 6 5b The set is illustrated for a left hand open out door (see illustration). 8 7 Right hand door OUTSIDE Left hand door 6b 1d 1b INSIDE 1a 9 4b 1 1c 2 Sets and parts: Base set n 5701-1 (1) Rod n 5701-... (2) Set of rods n 5701-3 or n 5701-3B including: additional bottom locking point (3) connection rod (4) additional top locking point (5) connection rod (6) guiding pieces (7) Handle n 5701-.. or 82000-26 (8) Cylinder n 880-.. (9) 4 7 Attention: 4a 3 3b The set can be operated from the outside: with door handle with door handle and cylindre The lock is not cylinder-operated: it is not possible with a cylinder only on the outside. 3a K13.12.12

6.2. Assembling order Note: These instructions are for a left hand open out door. 1) Cut out the opening for cylinder and handle and drill 4 holes ø3.5 mm in the vent section in accordance with the dimensions on the drawing. 2) Drill 4 holes ø3.5 mm at the hinge side of the door in the same way and at the same height as the left hand middle device. 3) Cut off the push bar (2) to the correct length. 4) Position the left hand middle lock (1) and fix it to the vent section by 4 screws. 5) Slide in the push bar (2) in the cavity of the left hand lock (1) and fix it. 6) Position the right hand lock (1 ) while the right hand side of the push bar (2) is engaged. Fix the lock to the vent section by 4 screws. 7) Screw the right hand side of the push bar. 8) Drill the 4 (or 5 for the top locking point) fixing holes ø3.5 mm for the bottom locking point (3) in accordance with the dimensions on the drawing. 9) Position the bottom locking point (3) on the fixing holes and fix it by 4 screws (or 5 for the top locking point) screws. 10) Cut off the connection rod (4) to the correct length. Slide the rod into the plate opening of the bottom locking point mechanism (see drawing). At the same time, slide the fixing ring (4a) on the connection rod without fixing it. First, screw the rod to the middle lock with a brass screw (4b). Then, slide the ring against the plate with the opening and fix it. 11) Top locking point (5) : as instruction 8. 12) Position the top locking point (5) : as instruction 9. 13) Connection rod (6) : as instruction 10. 14) Position keep (1a) for the middle lock and drill 2 holes ø3.5 mm. 15) Fix keep (1a) by 2 screws. 16) Top keep (5a) : as instruction 14. 17) Fix keep (5a) by 2 screws. 18) Close the door to position the bottom keep (3a) opposite the latch (see illustration). Drill the 2 holes ø5 mm. Place the 2 plugs and fix the keep. 19a) Installation door handle 5701-..: - drill 3 holes D = ø4.2 mm. - place and fix the base + mount the cover plate. 19b) Installation door handle 82000-26 (8): - drill 2 holes D = ø4.2 mm. - place and fix the base + mount the cover plate. Fixing holes door handle: - 5701-..: A = 21.5 mm B = 118.5 mm - 82000-26: A = 21.5 mm B = 0 mm 20) Place cylinder (9) and fix it (screw is not included). 21) Before fixing the covers, we advise you to check the operation of the panic exit device. 22) Place the covers (1b, 3b, 5b) and fix them by 2 little countersunk screws. 23) Position the guiding pieces (7) above and below the middle lock: drill two holes ø2.3 mm and fix the guiding piece by two screws. Quantity and position guiding pieces: see page K13.12.04. K13.12.13

6.3. Profile preparations With additional locking set n 5701-3 Frame profile edge Notes: The position of the panic exit device relative to the frame profile is indicative and depends on: the available space the rotation circle of the door The position of the keeps depends on: the available space to screw the keep flush or rebated door the use of thickness plates the rotation circle of the door Floor level K13.12.14

With additional locking set n 5701-3B Frame profile edge Notes: The position of the panic exit device relative to the frame profile is indicative and depends on: the available space the rotation circle of the door The position of the keeps depends on: the available space to screw the keep flush or rebated door the use of thickness plates the rotation circle of the door Floor level K13.12.15

6.4. Detail bottom keep Connection rod 4 SIDE VIEW Vent section Bottom locking point 3 Keep 3a TOP VIEW Vent section Frame 6.5. General notes and instructions Check the gaskets do not effect the operation of the panic exit device. The panic exit device can only be installed on glass doors provided that the glass is tempered or laminated. The components and keeps must be firmly fixed on the sections. After the installation, please check that the latches are fully retracted when operating the push bar so that the door can be opened. For the satisfactory operation of the panic exit device, please follow strictly the installation instructions. To ensure a satisfactory operation, we advise you to execute monthly the following check-ups yourself: Examine and operate the panic exit device to check the good working of the device and all its parts. Check if the latches are retracted by operating the push bar, even at low pressure, and if the latches have a free passage when opening the door. After the installation, please give a copy of these installation and maintenance instructions to the user. K13.12.16