Jacksonville District Master ************************************************************************** USACE / CESAJ

Similar documents
UNIFIED FACILITIES GUIDE SPECIFICATIONS

DIVE PLAN SUBMITTAL FORM

University System of Maryland (USM) Dive Plan Approval Form To be submitted to the USM Scientific Diving Safety Officer

MOTION NO. M Contract Amendment for Systems Construction Management Consultant Services

AGREEMENT BETWEEN THE U.S. FISH AND WILDLIFE SERVICE AND THE U.S. ARMY CORPS OF ENGINEERS FOR CONDUCTING FISH AND WILDLIFE COORDINATION ACT ACTIVITIES

USF/FIO Dive Plan Approval Form To be submitted to both the: Keys Marine Lab & the USF/FIO Scientific Diving Office

Processing Requests & Petitions For Streets To Be Improved/Chip Sealed

UNIFIED FACILITIES GUIDE SPECIFICATIONS

2012 INDUSTRY DAY Society of American Military Engineers - Omaha Post

GOM Diving Safety Work Group. Recommended Minimum Dive Team Manning 3/18/2016

The Facts about Water Tank Diving Evaluations. Jennifer Coon, CSP, CHMM, CET Safety Director Tank Industry Consultants

UK ADC Ltd. Association of Diving Contractors. Inland / Inshore Diving Supervisors Certification Scheme

MONOPLACE HYPERBARIC CHAMBER EMERGENCY PROCEDURES April 2006

HAZARDOUS WASTE OPERATIONS AND EMERGENCY RESPONSE (HAZWOPER)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SWIM POOL MANAGEMENT City of Blue Springs, Missouri

AS/NZS :2013. Training and certification of occupational divers AS/NZS :2013. Part 5: Dive supervisor. Australian/New Zealand Standard

UNIFIED FACILITIES GUIDE SPECIFICATIONS

IMCA Competence Assessment Portfolio June 2013

AS/NZS :2013. Training and certification of occupational divers AS/NZS :2013. Part 2: Surface supplied diving to 30 m

Application form session

Department of the Interior Departmental Manual

SECTION LEAD-PAINT REMOVAL

ADCI Consensus Standards - GAP Analysis Rev. 6 and 6.1 April 2, 2014

DIVING SERVICES UK COMMERCIAL & RESCUE DIVING CONTRACTORS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

ROLE DESCRIPTIONS BY COMPETENCY LEVEL

Diving Operations Procedure

DETAIL SPECIFICATION HOSE ASSEMBLIES, ELASTOMERIC HYDRAULIC FLUID, FUEL, AND OIL RESISTANT, GENERAL SPECIFICATION FOR

QUALITY ASSURANCE SPECIFICATION NONDESTRUCTIVE EXAMINATION PAGE 1 OF 7

NYSPHSAA State Championship Site/ Facility Bid GIRLS TENNIS 2020, 2021, 2022

SIERRA-SACRAMENTO VALLEY EMS AGENCY PROGRAM POLICY REFERENCE NO. 474

ADCI COMMENTS ON USCG NPRM TO 46 CFR PART 197 SUBPART B

SPECIFICATIONS - DETAILED PROVISIONS Section Butterfly Valves C O N T E N T S

ST. LUCIE COUNTY, FLORIDA

City of Conway Mayor s Office 1201 Oak Street Conway, AR Invitation and Bid

REQUEST FOR PROPOSAL NW Barry Road Kansas City, MO Park Hill School District Grandstand Installation

REQUEST FOR BIDS For Intake Tunnel Project Bid Notice

Hazardous Materials Management. Presented by. James E. Roughton, MS, CSP, CRSP, CHMM.

Date of Site Visit: Project Site Location: Contract Number: Task Order Number: Contractor s Name: Contractor s Address: Prepared by: Signature: Date:

Contractor/Visitor Safety Orientation UNBC

ABSTRACT PLANT FILES SHOULD BE REVIEWED PERIODICALLY TO ASSURE COMPLIANCE. IF A PROBLEM EXISTS, PLEASE NOTIFY THE TACA SAFETY COMMITTEE.

Reviewing Hyperbaric Oxygen Services: Consultation Guide

BID SPECIFICATIONS. Tablets FOR. Hardeman County Schools

Savannah River, Georgia and South Carolina

AAUS Scientific Diving History and Regulations

2.0 Dates and Times Tests to be carried out starting Monday 28 Nov for completion Friday 2 Dec.

FOREST SERVICE HANDBOOK NATIONAL HEADQUARTERS (WO) WASHINGTON, DC

DIVE ADMINISTRATION (5AD) Checklist

Onshore Supervisor Pathway Information for Students. ADAS Diploma of Hyperbaric Operations (Diving supervision)

Common Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits

UNDERWATER VEHICLES, SYSTEMS AND HYPERBARIC FACILITIES 2002

Bowling Green Area Convention & Visitors Bureau REQUEST FOR PROPOSALS REVISED 9/2017

Town of Berwick Maine. Request for Proposal Ambulance Services. July 1, June 30, 2014

Ontario Recreational Canoeing and Kayaking Association

Request for permission to work on a public sewer S106 (part 2 application form) 2018/19

San José State University Kinesiology Dept. Scuba Diving Kin , Fall 2015

EM Global Initiatives in diving, Balder Life Extension Project & Decommissioning Opportunities

1. The Middletown Public Schools will have defibrillators in each school building.

MARINE EMERGENCY ACTION PLAN FOR MARINE RESEARCH

Remove Bell definition. Add Closed Bell and Open Bell.

SAFE WORK METHOD STATEMENT (SWMS)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION BUTTERFLY VALVES

Assessment of Academic Ability EXAMINATION PRACTICE PAPER. This paper must not be used for actual examinations. DCTAS Development

SWMS No 012 Samark North Qld Pty Ltd ABN : Electrical Contractors License C37121 Page 2 of 6

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR DIGITAL MULTIMETER, GREENLEE MODEL DM-40

SAFETY IN COMMERCIAL DIVING PRACTICES: A COMPARISON OF THREE (3), FOUR (4), AND FIVE (5) MAN DIVE TEAMS

Subj: HYPERBARIC OXYGEN TREATMENT IN NAVY RECOMPRESSION CHAMBERS

NRA MANUAL OF CONTRACT DOCUMENTS FOR ROAD WORKS

DATA ITEM DESCRIPTION

Australian/New Zealand Standard

Hazardous Waste Operations and Emergency Response (HAZWOPER)

NOAA DIVING PROGRAM MINIMUM STANDARD FOR DECOMPRESSION DIVING USING OPEN-CIRCUIT SCUBA EQUIPMENT

Contractor OHS Induction. AOHS-05-GUI September 2016

December MTS Houston Luncheon. Hoover Offshore Oil Pipeline System (HOOPS) GA-A244 Bypass and Wye Inspection

Emergency Medical Services Agency Public Safety AED Service Provider Guide

DAN EUROPE PROCEDURES FOR THE MANAGEMENT OF DIVING ACCIDENTS AND PAYMENT OF CLAIMS CONCERNING MEMBERS OF DAN EUROPE

UNIFIED FACILITIES GUIDE SPECIFICATIONS

This guidance applies to those individuals who perform acid cleaning or chemical treatment aboard Marine Depot Maintenance Command Yermo CA.

ADOPTED REGULATION OF THE BOARD OF WILDLIFE COMMISSIONERS. LCB File No. R Effective December 23, 2013

SWMS No 001 Samark North Qld Pty Ltd ABN : Electrical Contractors License C37121 Page 2 of 5

Abu Dhabi EHSMS Regulatory Framework (AD EHSMS RF)

ARLINGTON COUNTY, VIRGINIA. County Board Agenda Item Meeting of May 19, 2018

East Branch Dam Safety Modification Project

Annacis Island Wastewater Treatment Plant OUTFALL PROJECT

1. HISTORY: This issue publishes a revision of this publication.

MANUFACTURING TECHNICAL INSTRUCTIONS - SAFETY FALL HAZARD CONTROL REQUIREMENTS SERIES & NO. SMI - 157

DRAFT. October 17, 2014 File No Mr. Brendhan Zubricki Town Administrator Essex Town Hall 30 Martin Street Essex, MA.

TRAFFIC IMPACT STUDY CRITERIA

University of Cincinnati. Radiation Safety Committee Operations Guidelines Statement of Policy (RSC Guidelines) RSC Guidelines (revision 5)

Section 33 TABLE OF CONTENTS Hazardous Waste Operations and Emergency Response (HAZWOPER) 33.A General

MINIMUM COURSE CONTENT FOR Recreational Scuba Instructor Trainer Certification

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Scottish Hyperbaric Medical Service Strategic Context and Overview

Water Tank Inspection Standards & Guidelines

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Revised Safety Plan. Page 1. Penna. Prepared by Penna. October, 20100

Transcription:

USACE / DEPARTMENT OF THE ARMY 01 35 25 (Apr 2006) U.S. ARMY CORPS OF ENGINEERS JACKSONVILLE DISTRICT LOCAL MASTER GUIDE SPECIFICATION SECTION TABLE OF CONTENTS DIVISION 01 - GENERAL REQUIREMENTS SECTION 01 35 25 OWNER SAFETY REQUIREMENTS - DIVING 10/13 PART 1 GENERAL 1.1 SUMMARY 1.1.1 Related Section 1.2 REFERENCES 1.3 SAFETY AND HEALTH REQUIREMENTS MANUAL 1.4 DEFINITIONS 1.5 SUBMITTALS 1.6 DIVE PLAN 1.6.1 Dive Plan Reviewer 1.7 MEETINGS 1.7.1 Phase Meetings PART 2 PRODUCTS (NOT APPLICABLE) PART 3 EXECUTION 3.1 EMERGENCY MEDICAL TREATMENT 3.2 DIVING OPERATIONS 3.2.1 Dive Operations Execution -- End of Section Table of Contents -- SECTION 01 35 25 Page 1

USACE / DEPARTMENT OF THE ARMY 01 35 25 (Apr 2006) U.S. ARMY CORPS OF ENGINEERS JACKSONVILLE DISTRICT LOCAL MASTER GUIDE SPECIFICATION SECTION 01 35 25 OWNER SAFETY REQUIREMENTS - DIVING 10/13 NOTE: Master 01 35 25 (K3) was developed after UFGS 01 32 39 was required for use in all contracts. It covers Diving Safety requirements specific to Jacksonville District (K3). 01 35 25 is for use for all contracts that have work over water or may require underwater inspection. It is applicable to all Dredge jobs. Use e-mail for suggested changes. Comments are encouraged and should be directed to: Construction Division, Quality Assurance Branch POC Mr. Bruce Tappmeyer, 904-232-3835. or 01 35 25 is for use by both District in-house and A/E Designers. NOTE: Brackets are used for designer choices or when text must be supplied. During Preliminary Design PDT Specifiers and Construction field personnel must identify when Diving will be required. Make section site and project work specific. Specifiers, make section, clear, concise, correct and complete, editing out items not applicable to project. PART 1 GENERAL 1.1 SUMMARY Section covers job specific underwater diving requirements and dive safety. 1.1.1 Related Section Section 01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS. SECTION 01 35 25 Page 2

1.2 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only. U.S. ARMY CORPS OF ENGINEERS (USACE) EM 385-1-1 Safety and Health Requirements Manual 1.3 SAFETY AND HEALTH REQUIREMENTS MANUAL EM 385-1-1, is available at http://140.194.76.129/publications/eng-manuals/. One copy will be provided to Contractor at a Preconstruction Conference (refer to Section 01 30 00 ADMINISTRATIVE PROCEDURES. 1.4 DEFINITIONS Use definitions found in EM 385-1-1 in transmitted dive plan submittal items. Dive Supervisor - A person with specialized training or experience in Dive safety. 1.5 SUBMITTALS NOTE: Refer to Section 01330 SUBMITTAL PROCEDURES for Government office identifier designations. The importance of an item in the project should be one of the primary factors in determining if a submittal for the item should be required. Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES. Submit the following preconstruction submittal items no later than 20 calendar days after award or 5 calendar days after Notice to Proceed, whichever is later: SD-01 Preconstruction Submittals Dive Operations Plan; G, RO Refer to paragraphs DIVE PLAN, DIVING OPERATIONS, and DIVE OPERATIONS below. SD-07 Certificates Dive Personnel Qualifications; G, RO Qualifications, and training certificates of dive personnel. Annual diver physicals shall conform to the requirements of EM 385-1-1, 30.A.10. Contractor shall submit only a statement from a licensed physician that states the diver is "Fit To Dive". SECTION 01 35 25 Page 3

1.6 DIVE PLAN Submitted physician statement shall contain at a minimum the diver name, examination date, physician's name, physician's signature, physicians' medical license number, and physicians telephone number. The signing physician shall be an MD or an OD. Submitted statement shall not contain divers Personal Health Information (PHI) or Personal Identification Information (PII). Dive plan shall address all requirements of Section DIVING OPERATIONS of EM 385-1-1. See paragraph DIVE OPERATIONS below. An approved Dive Plan and Safe Practices Manual is required on all projects with work on, or over water; see paragraph DIVING OPERATIONS below. 1.6.1 Dive Plan Reviewer Dive Plans shall be submitted by Contractor to Contracting Officer in accordance with Section 01 33 00 SUBMITTAL PROCEDURES. Dive Operations Plans are "District Office (DO)" secondary reviewed by Jacksonville District Diving Coordinator or his Alternate. Dive Coordinator: Mr. Bruce Tappmeyer W 904-232-3835, Fax 904-232-1590 Bruce.A.Tappmeyer@usace.army.mil Alternate Dive Coordinator: Mr. Jim Vecchitto W 904-232-3808, Fax 904-232-2147 James.J.Vecchitto@usace.army.mil. When a transmittal with a Dive Plan submittal item is delivered to Resident Engineer, send a copy directly to: Delivery Address: U.S. Army Corps of Engineers - Jacksonville District ATTN: -CD-Q (Mr. Tappmeyer) 701 San Marco Blvd Jacksonville, FL 32207-8175 Mailing Address is PO Box 4970 U.S. Army Corps of Engineers - Jacksonville District ATTN: -CD-Q (Mr. Tappmeyer) PO Box 4970 Jacksonville, FL 32232-0019 1.7 MEETINGS 1.7.1 Phase Meetings Each Dive shall be treated as a "definable feature of work" in accordance with accepted Quality Control Plan. Perform a Preparatory and Initial Phase meeting for all Dives. SECTION 01 35 25 Page 4

PART 2 PART 3 PRODUCTS (NOT APPLICABLE) EXECUTION 3.1 EMERGENCY MEDICAL TREATMENT Arrange with local authorities for emergency dive medical response, treatment and evacuation to medical facility and nearest hyperbaric chamber. Provide map with route directions to nearest hospital and hyperbaric chamber in dive plan Emergency Management Plan required by EM 385-1-1. 3.2 DIVING OPERATIONS NOTE: Include paragraph in all contracts where work is on, or over water. Submit a Dive Operations Plan when work is performed on or over water. No matter if a dive is actually planned or only required as a contingency (i.e., most dredging projects) submit a Diving Operations Plan for Contracting Officer's approval. Dive Operations Plan shall cover all requirements in Section DIVING OPERATIONS of EM 385-1-1. Dive Operations Plan consists of a "Safe Practices Manual" describing Contractor's diving program and a "Dive Plan" describing site specific information of proposed dive or contingency dive. Safe Practices Manual, Dive Plan and revisions shall have cover sheets signed and dated by Contractor. When diving is subcontracted, cover sheets shall also be signed and dated by diving contractor's principal or authorized representative. 3.2.1 Dive Operations Execution Execute dives in accordance with approved Dive Operations Plan submittal; Section DIVING OPERATIONS of EM 385-1-1. Contractor shall submit completed daily dive logs at the end of each dive day. Daily dive logs shall be faxed to District Dive Coordinator 904-232-1590 or his authorized representative. Contractor shall use COE form ENG 4615 and ENG 4616 to record daily diving activities. -- End of Section -- SECTION 01 35 25 Page 5