Let s talk about Capnography

Similar documents
Monitoring, Ventilation & Capnography

Capnography in the Veterinary Technician Toolbox. Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA

Practical considerations in anaesthetising exotic species. By Keith Simpson BVSc MRCVS AMIIE(Electronics).

Chapter 4: Ventilation Test Bank MULTIPLE CHOICE

Capnography. The Other Vital Sign. 3 rd Edition J. D Urbano, RCP, CRT Capnography The Other Vital Sign 3 rd Edition

UNIQUE CHARACTERISTICS OF THE PULMONARY CIRCULATION THE PULMONARY CIRCULATION MUST, AT ALL TIMES, ACCEPT THE ENTIRE CARDIAC OUTPUT

I Physical Principles of Gas Exchange

TV = Tidal volume (500ml) IRV = Inspiratory reserve volume (3,000 ml)

Lung Volumes and Capacities

The physiological functions of respiration and circulation. Mechanics. exercise 7. Respiratory Volumes. Objectives

II. Set up the monitor

PICU Resident Self-Study Tutorial The Basic Physics of Oxygen Transport. I was told that there would be no math!

Selecting and Connecting Breathing Systems

By: Aseel Jamil Al-twaijer. Lec : physical principles of gas exchange

Respiratory Physiology Gaseous Exchange

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

Section Two Diffusion of gases

Medical Instruments in the Developing World

Part 1: Inspiratory and expiratory pressures

RESPIRATORY PHYSIOLOGY, PHYSICS AND PATHOLOGY IN RELATION TO ANAESTHESIA AND INTENSIVE CARE

APNOEA AND PRE-OXYGENATION

ALVEOLAR - BLOOD GAS EXCHANGE 1

EMS INTER-FACILITY TRANSPORT WITH MECHANICAL VENTILATOR COURSE OBJECTIVES

Collin County Community College. Lung Physiology

A CO 2 Waveform Simulator For Evaluation and Testing of Respiratory Gas Analyzers

BREATH-BY-BREATH METHOD

Indications for Mechanical Ventilation. Mechanical Ventilation. Indications for Mechanical Ventilation. Modes. Modes: Volume cycled

Volumetric Gas Measurements Measurement Site Considerations

Selecting the Ventilator and the Mode. Chapter 6

LUNG CLEARANCE INDEX. COR-MAN IN Issue A, Rev INNOVISION ApS Skovvænget 2 DK-5620 Glamsbjerg Denmark

RESPIRATORY GAS EXCHANGE

RESPIRATORY REGULATION DURING EXERCISE

Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo

Vienna, Austria May 2005 MONITORING GAS EXCHANGE: FROM THEORY TO CLINICAL APPLICATION

DOWNLOAD OR READ : VENTILATION BLOOD FLOW AND DIFFUSION PDF EBOOK EPUB MOBI

Initiation and Management of Airway Pressure Release Ventilation (APRV)

Respiratory System Physiology. Dr. Vedat Evren

Monitoring. Suzie Ward March 2013

Recitation question # 05

Unit II Problem 4 Physiology: Diffusion of Gases and Pulmonary Circulation

RESPIRATORY PHYSIOLOGY, PHYSICS AND

Human gas exchange. Question Paper. Save My Exams! The Home of Revision. Cambridge International Examinations. 56 minutes. Time Allowed: Score: /46

1.2 The structure and functions of the cardio-respiratory system Learning objectives

Tter person TERM PAPER. Date: 30/4/ MEDICAL VENTILATOR

How does HFOV work? John F Mills MBBS, FRACP, M Med Sc, PhD Neonatologist Royal Children s Hospital. Synopsis

Respiration (revised 2006) Pulmonary Mechanics

Advanced Ventilator Modes. Shekhar T. Venkataraman M.D. Professor Critical Care Medicine and Pediatrics University of Pittsburgh School of Medicine


bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance

Chapter 37: Pulmonary Ventilation. Chad & Angela

VT PLUS HF performance verification of Bunnell Life-Pulse HFJV (High Frequency Jet Ventilator)

Name: Oasis: Questions EPCP. Professional Development: ETCO2 Monitoring

Pulmonary Circulation Linda Costanzo Ph.D.

Public Assessment Report Scientific discussion. Lung test gas CO (He) AGA, 0.28%, inhalation gas, compressed (carbon monoxide, helium) SE/H/1154/01/MR

Physiology (3) Pulmonary Function Test:

INTRODUCTION TO BI-VENT (APRV) INTRODUCTION TO BI-VENT (APRV) PROGRAM OBJECTIVES

Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 6th Edition by Cairo

VENTILATION AND PERFUSION IN HEALTH AND DISEASE. Dr.HARIPRASAD VS

Mechanical Ventilation

Determination of the Frequency Response of an End Tidal CO2 Analyser

The Physiologic Basis of DLCO testing. Brian Graham Division of Respirology, Critical Care and Sleep Medicine University of Saskatchewan

3100A Competency Exam

CHAPTER 3: The respiratory system

Figure 1. A schematic diagram of the human respiratory system.

Respiratory Physiology. Adeyomoye O.I

Respiratory System Lab

LAB 3: RESPIRATORY MECHANICS

McHENRY WESTERN LAKE COUNTY EMS SYSTEM FALL 2014 CONTINUING EDUCATION MANDATORY FOR ALL PRIMARY AND PROBATIONARY ALS SYSTEM PROVIDERS.


CARBON DIOXIDE ELIMINATION FROM SEMICLOSED SYSTEMS

VENTILATORS PURPOSE OBJECTIVES

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Diffusing Capacity: 2017 ATS/ERS Standards for single-breath carbon uptake in the lung. Susan Blonshine RRT, RPFT, FAARC, AE-C

BIOLOGY 12: UNIT J - CHAPTER 15 - REVIEW WORKSHEET RESPIRATORY SYSTEM

Gas exchange measurement in module M- COVX

April KHALED MOUSA BACHA. Physiology #2. Dr. Nayef AL-Gharaibeh. Pulmonary volumes & capacities

PULMONARY FUNCTION TESTING CORE

CHAPTER 3: The cardio-respiratory system

Respiratory Signs: Tachypnea (RR>30/min), Desaturation, Shallow breathing, Use of accessory muscles Breathing sound: Wheezing, Rhonchi, Crepitation.

PROBLEM SET 8. SOLUTIONS April 15, 2004

Respiratory Physiology. ED Primary Teaching

Table of Contents. By Adam Hollingworth

Standard Operating Procedure

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

RESPIRATORY PHYSIOLOGY. Anaesthesiology Block 18 (GNK 586) Prof Pierre Fourie

Errors in Monitoring. BWH Clinical Conference 10/06/04. Copyright 2004, James H Philip, all rights reserved.

Respiratory system & exercise. Dr. Rehab F Gwada

Chapter 17 The Respiratory System: Gas Exchange and Regulation of Breathing

PROBLEM SET 9. SOLUTIONS April 23, 2004

Circulatory And Respiration

Pressure Controlled Modes of Mechanical Ventilation

Classification of Mechanical Ventilators

PROBLEM SET 7. Assigned: April 1, 2004 Due: April 9, 2004

Respiration. Figure 22: Schematic representation of the respiratory system

(a) (i) Describe how a large difference in oxygen concentration is maintained between a fish gill and the surrounding water.

WHY BUY AN SAV03? BENEFITS SEE WHAT OUR CUSTOMERS THINK!

Respiratory System Review

Hypoxia Following Rapid Decompression to 18,288 m (60,000 ft) Attributable to Alveolar Hypoventilation

Respiratory Physiology 2

SUMMARY OF PRODUCT CHARACTERISTICS

Transcription:

Let s talk about Capnography This is one of a series of articles by Keith Simpson BVSc MRCVS MIET (Electronics) discussing the practical aspects of some common monitoring techniques. Capnometry is the measurement of the levels of exhaled carbon dioxide, which can be measured by a capnometer, which displays the numerical value only. The actual trace is observed on a capnograph and is referred to as a capnogram. Measurement of exhaled CO 2 can be very informative of the patient s condition if you are aware of what is being measured and what deviations from the normal represent. Before getting too involved in the physics and physiology of capnography some explanation of nomenclature and conventions might be helpful. PetCO 2 is an accurate reflection of the PaCO 2 and normal values are expected to be of the order of 35-40mmHg. Now what does all that mean!!? PetCO 2 is an abbreviation for the partial pressure of end-tidal CO 2 and PaCO 2 is an abbreviation for the partial pressure of arterial CO 2. But what is partial pressure, and isn t it the same as the percentage? Well, no it isn t the same. Partial pressures are a means of expressing a media (normally a gas) as a fraction of another gas. Because the lungs are directly exposed to the atmosphere gas pressures can be related to atmospheric pressure. Atmospheric pressure is nominally 760mmHg (millimetres of mercury). All the partial pressures of the gases that make up air will add up to 760mmHg. For example, say for arguments sake air is 21%oxygen, and 79% nitrogen then the partial pressure of oxygen plus the partial pressure of nitrogen must equal the total pressure, which is 760mmHg. Oxygen in this instance would have a partial pressure of 160mmHg and nitrogen would be 600mmHg. Now it s no coincidence that 160/760 is 21% because that s how you convert from partial pressure to percentage. So now when we look at the above statement we see that the normal partial pressure of CO 2 in expired breath is 35mmHg or35/760 x 100% = 4.6%. The easiest way to remember it is that 1% is equivalent to approximately 8 mmhg. Different machines will display the results differently and some allow you to change between percentage and partial pressures depending on your preference. Sidestream versus Mainstream These terms are frequently talked about and deserve some explanation. They refer to the position of the CO 2 sensor. In a sidestream device a portion of the patient s breath is sucked off down a tiny tube for analysis inside the main unit. This has several implications. CRN:4694235; VAT No 585 6341 12. Managing Director: Keith Simpson BVSc MRCVS MIET(Electronics) Page 1 of 9

Firstly it takes time for the gas to arrive at the unit so the patient s breathing movement seem to be out of phase with the capnogram. Depending on the breathing rate and the sidestream withdrawal rate, the capnogram could be a breath or two behind the patient. Secondly because some gas is removed from the airway there is a limit on the low-end resolution. Many capnometers withdraw around 200mls/minute, which is excessive if you have a small animal with a minute volume of less than 500mls/minute. Some capnometers allow you to adjust the withdrawal rate for small animals. This is a help but if the animal has a rapid breathing rate (which the small ones invariably do) distinction of the breaths becomes lost and the capnometer gives the wrong result. This is the major unavoidable limitation of sidestream technology. In a mainstream device the sensor sits right next to the patient and measures the CO 2 levels that pass through the airway to the patient. With a mainstream device the capnogram follows exactly the patient s breathing pattern. When the patient breaths out the capnogram shows a rise in CO 2. It doesn t matter how small the patient is ( as long as the tidal volume exceeds the dead space) because there is no gas withdrawn and no dilution effect. These units are nicer to work with but command a much higher price. The downside to a mainstream device is that the patient needs to be intubated, whereas you can use a sidestream device via a nasal tube or a face mask. Before going too far let s look at a typical capnogram from a CO 2 monitor: Expiration Inspiration III II β 0 I Normal patient CRN:4694235; VAT No 585 6341 12. Managing Director: Keith Simpson BVSc MRCVS MIET(Electronics) Page 2 of 9

This is a time capnogram. There are other ways of depicting the expiration of CO 2 but for now we will stick with a time capnogram which means that time passes from left to right and the height indicates the CO 2 level. Without getting too technical here the phases of the graph are subdivided into the expiratory phase comprising, Phases I-III plus the alpha angle and the inspiratory phase comprising phase 0 and the beta angle. Phase I represents exhalation of air within the anatomical dead-space and because this is just air that has been sucked in and blown out again it has the same composition as room air. Then air from the lungs begins to be exhaled and the CO 2 level rises and more or less plateau s before falling during inspiration. We ll look at what each phase represents in more detail later. So how can capnography help? There are two areas where capnography gives us vital information. Firstly, we have the peak end-tidal CO 2 value, which is simply a numerical expression of the maximum amount of CO 2 detected in that breath. Secondly, and more subtly is the variations within the capnogram itself which give information on the way CO 2 is being eliminated from the lungs. The combination of these two pieces of information is where the real value of capnography lies. What are we actually measuring? On the face of it, it looks very simple. We are just measuring the CO 2 produced by the lungs. However, when you start looking at this more closely you realise that what is being measured is the composite exhalation of CO 2 after mixing in the trachea and that because the different parts of the lungs are emptying at different rates and are exposed to differing ventilation perfusion ratios, the actual levels being exhaled vary over the course of the breath, between breaths and with posture. As a quick example, in obese or pregnant patients the effect of diaphragmatic/thoracic compression results in a terminal emptying of the alveoli in excess of the normal. For this reason there is often an upturn at the end of the CO 2 profile. The end-tidal statement is important. The assumption made is that the last portion of breath at the end of the tidal volume comes from and is representative of the alveoli. Because alveolar CO 2 (PACO 2 ) is a close approximation to arterial CO2 (PaCO2) and because end-tidal CO 2 (PetCO 2 ) is a close approximation to alveolar CO 2 we can use end-tidal CO 2 as an indicator of arterial CO 2. That way we don t have to take blood to assess the arterial CO 2 level. Capnography gives us a simple way of monitoring arterial CO 2. CRN:4694235; VAT No 585 6341 12. Managing Director: Keith Simpson BVSc MRCVS MIET(Electronics) Page 3 of 9

When we look at the screen of a typical capnograph we see something like this: Figure 1.01 typical display Capnograph machine We have a CO 2 value, a respiratory rate and a capnogram. The value in using a capnograph is not just with looking at the end-tidal CO 2 value (which of course is helpful) but in understanding exactly what that means and in understanding the capnogram as well. CO 2 value. This is the peak or maximum measured CO 2 value in the last breath. This value may be averaged with preceding values or may be a report of the actual last breath measured, depending on the machine. Either way it is just the peak value and in the same way that the systolic blood pressure reading only tells you part of the story so does the PetCO 2 value. Because it s the peak value you don t know how that value is derived or produced. If we go back to our pregnant patient and compare with our normal we see two different capnograms. This graph is an exaggeration of the effect but it does show the principle involved. CRN:4694235; VAT No 585 6341 12. Managing Director: Keith Simpson BVSc MRCVS MIET(Electronics) Page 4 of 9

45mmHg PetCO2 30mmHg Time Obese/pregnant patient What we see is an upturn at the end of expiration that increases the PetCO 2 value by 15mmHg. If we were just looking at the PetCO 2 value this could be misleading because it might seem a bit high. But by looking at the waveform we can see that the average end tidal CO 2 value is 35mmHg and only rises momentarily to 45mmHg because of the extra air being forced from the alveoli. In extreme cases this could rise higher without there necessarily being a cause for concern, as long as the plateau phase (phase III) was normal. The point behind this is that you need to look at the waveform as well as the PetCO 2 value. The increase in this end-tidal value is interesting. As the lungs collapse during expiration their volume decreases, but the addition of CO 2 is relatively constant so the effective CO 2 concentration rises. Also there is late emptying of alveoli with a low ventilation/perfusion ratio which therefore have a higher CO 2 concentration. In normal patients this results in a positive slope to phase III and in obese patients gives us the late emptying effect seen above. What do the phases represent? Phase I. This represents the expiration of gas from anatomical dead space. Phase II. Here alveolar gas is mixing with dead space gas Phase III. Expired gas consists almost entirely of alveolar gas. This phase typically has a positive slope. Phase 0. Inspiration. Alpha angle. The angle between phase II and phase III. The rate of transition from phase II to phase III is an indicator of the ventilation/perfusion ratio of the lungs. CRN:4694235; VAT No 585 6341 12. Managing Director: Keith Simpson BVSc MRCVS MIET(Electronics) Page 5 of 9

Phase III is the most important as it provides information on how the lungs are emptying and indicates the V/Q status of the lungs. One point that may not be immediately clear is that as the lungs empty blood is continually delivering CO 2 to the alveoli. These alveoli therefore have increasing amounts of CO 2 in them so phase III has a positive slope. Also note that the situation in a dog and a horse is different. With the slow heart rate in a horse perhaps only one pulse perfuses the lungs during expiration whereas with a dog 3 or 4 pulses may perfuse the lung during expiration. This will result in different profiles between the species. What else can the Capnograph tell us? Rebreathing If a patient is rebreathing its own exhaled gas then the CO 2 levels will rise. Inhaled air will not be free of CO 2 so the baseline will start to rise. The PetCO 2 will also rise but it is more apparent from the capnogram than from the numerical value. This can be extremely valuable for ventilated patients or patients connected to a rebreathing anaesthetic circuit. Rising baseline indicative of rebreathing CRN:4694235; VAT No 585 6341 12. Managing Director: Keith Simpson BVSc MRCVS MIET(Electronics) Page 6 of 9

If the effect is slower which it typically is, you will see something similar to the next diagram: CO 2 Waveform does not return to baseline. Some monitors will show this as a rising inspiratory CO 2 value Cardiac output If all other parameters are stable then changes in CO 2 can indicate cardiac output. A fall in cardiac output and pulmonary flow will result in a fall in PetCO 2 because CO 2 is simply not being delivered back to the lungs at the normal rate. Conversely a rise in cardiac output will be associated with better alveolar perfusion and a rise in PetCO 2. This effect can be clearly seen during procedures that affect pulmonary flow such as during an exploratory thoracotomy and can be very helpful to the anaesthetist. A represents a fall in CO 2 due to reduced cardiac output A CRN:4694235; VAT No 585 6341 12. Managing Director: Keith Simpson BVSc MRCVS MIET(Electronics) Page 7 of 9

Ventilation/perfusion ratio or V/Q ratio The ventilation/perfusion ratio is a ratio intended to give an indication of how well areas of lung are performing. Values are rarely referred to, anaesthetists preferring to talk about normal, low or high V/Q ratios. The nominator is Ventilation so as Ventilation increases the V/Q ratio increases. A ratio is used because both ventilation and perfusion are elements of successful lung function. A well ventilated but under-perfused lung (high V/Q) will have a low PetCO 2, and conversely a poorly ventilated but well perfused lung (low V/Q) will have a high PetCO 2 level. It is more informative to talk about areas of lung and their V/Q ratios than the lung as a whole because different areas of the lung have differing V/Q ratios. This is the whole essence of determining or interpreting the final capnogram. It is further complicated because the ventilation to a lung area may be adequate and the perfusion of lung area may be adequate, but not at the same time so there is still a V/Q mismatch (temporal mismatch). A spatial mismatch occurs when different areas of lung have differing V/Q ratios. The main points to remember are that the longer an alveolus holds its gas, the higher its CO 2 content will be and that the lower the V/Q ratio for an alveolus the higher its CO 2 content will be. Late emptying alveoli contribute to the rising slope of phase III and by looking at the overall pattern of phase III much information can be learned about lung function and its overall V/Q ratio. Summary 1) End-tidal CO 2 is used as an indicator of arterial CO 2. The two are not equal but PetCO 2 follows PaCO 2 very closely. 2) When evaluating a patient s end-tidal CO 2, look at the capnogram as well as the value 3) Sidestream technology has limitations with very small patients. This will also apply to mainstream devices depending on the dead space they represent. 4) The actual end-tidal CO 2 value tells only part of the story. 5) Read the end-tidal value in association with the capnogram. 6) A capnograph can give us additional information on rebreathing and cardiac output. 7) Understanding the physiology behind the production of the capnogram enables prediction of the causes of changes in the capnogram. 8) The area of capnography is a fascinating new area and there are features of capnography that are beyond the scope of this article. CRN:4694235; VAT No 585 6341 12. Managing Director: Keith Simpson BVSc MRCVS MIET(Electronics) Page 8 of 9

The capnometer and capnograph are relatively new instruments in the field of veterinary medicine but they have the potential to provide an awful lot of information about our patients in new ways and also in faster ways than previous instruments. Using them with an understanding of the principles involved will enhance our care of anaesthetised patients. For further details on this subject or Vetronic Services Products please don t hesitate to contact us on the below details: Tel: 01626 365505 Fax: 0870 129 4705 Email: enquiries@vetronic.co.uk Web: www.vetronic.co.uk CRN:4694235; VAT No 585 6341 12. Managing Director: Keith Simpson BVSc MRCVS MIET(Electronics) Page 9 of 9