Basic layout 2016 IRRIGATION-MART. Check (Non- Leak) Valve. Friction Fit. Sprinkler. Figure 1 - Hanging Sprinkler & Check Valve Assembly

Similar documents
Pressure Compensating (PC) Spray Stakes

Putting it All Together: Making Sense of Drip Irrigation UC Master Gardener Conference August 24, 2017

How Do I Install My Garden Master Bucket Garden?

Blue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS

Agricultural Water: Part 2

Irrigation System Winterization and Pressurization Procedures

VOLUMATIC WATER REGULATOR

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

Valves. Controllers. Valves Two Types

INSERT PRESSURE FITTINGS PRODUCTS PRICE LIST PRICE GROUP DISCOUNT MULTIPLIER DESCRIPTION 05 PVC INSERT FITTINGS

Sanitizer Parts. Sanitizer Parts. Replacement Parts for Sanitizers

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Rain Barrel Set Up. Supplies: Most supplies are available at your local hardware stores.

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

Smart Water Application Technologies (SWAT) TM

Underground irrigation

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

PVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION

Corporation Stops Technical Bulletin

Vessel Installation and Operating Manual

Adjustable. Unloader Valve. O&M Manual. Part #

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

6900 Professional Parkway East, Sarasota, FL Phone Fax Certificate of Authorization #43 FL Lic.

FI-25V OWNER S MANUAL

Installation and Operating Manual

CO2 Tank Conversion Kit P.N , P.N , and P.N

VOLUMATIC WATER REGULATOR

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

TABLE OF CONTENTS TABLE OF CONTENTS ABOUT US 02 (405)

TurboDraft Fire Eductor

Installation Guide. buoy.ai

Installation Instructions for NP100 Series Nitrogen Control Panels

Turf-Tec Precipitation and Uniformity Gauges

Bermad Pressure Reducing. Model: 42T

icon i150 / i350 Installation / Operation Manual

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

TECHLINE HCVXR AND CV DESIGN GUIDE DRIPLINE FOR SUBSURFACE AND ON-SURFACE

INSTALLING AN INEXPENSIVE AIR LINE TO MEASURE WATER DEPTHS IN WELLS

Overhead Irrigation Installation Guide DOM Copyright First Tunnels Ltd 2012.

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

Single and Triple Rain Barrel Setup

Water Hammer In Irrigation Systems 1

Installation Manual. Model # SF-3W 9/16/03 REV 1. Arch Chemicals, Inc Lower River Road. P.O. Box 800 Charleston, TN PULSAR

Installation Instructions

Description Advanced Features Typical Applications

Geotech 1.66 Auto-Reclaimer

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

PRO SINK -R 1 and 2. Dilution system CONTENTS

Crystal Spring Feeder Protocols

Bladder Tank Installation & System Design Information

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Hoses and Lances 20,000 PSI

10 DRIP NOZZLE WATERING DRIP KIT Model / Model 46095

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

REVERSE OSMOSIS INSTALLATION Watermark 4 Stage

Hydrotherapy Jets System for a Fiberglass Pool

Y O U R W A Y IRRIGATION COMPONENTS. adritec.com

Office Use Only Fee Paid

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual

FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

Air Operated Hydraulic Pumping Systems to 50,000 psi

Geotech 1.66 Auto-Reclaimer Installation and Operation

PRESSURE DROP CHARTS

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

EFLOW GUIDE. IRRIGATE UP TO 200m 2 SUITS DOMESTIC ONSITE APPLICATIONS

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

Winter Shut Down Procedure

INSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS

CHEMICAL. Straight cut rod is provided in the materials listed below and includes nuts / washers.

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

TECHNICAL DATA. Q = C v P S

KFI Approved. High Pressure CO2 System Technical Datasheets

TECHNICAL DATA. Q = C v P S

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

TECHNICAL DATA OBSOLETE

Grangeville Country Club Golf Course

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Instructions for using TSI Model mm or 8025-CEN Fit Test Adapter Kit

TECHNICAL DATA. Q = C v P S

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

1020 Industrial Drive, Orlinda, TN fax

Floor Drinking Systems

Combination Air Valve Model

DESIGN DATA. Dry 105a. September 5, 2008

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

US / 1400 Bubblers 1800 SAM-PRS 1800 SAM- PRS-45

USER GUIDE EMERGENCY PUMP KIT ULTRAFILTRATION ULTRAFILTRATION SYSTEMS. safe drinking water ULTRAFILTRATION UNIT FOR USE WITH:

Installation Guide & Owner s Manual. Model V4700. Water Filtration for Dental & Medical Instrument Washing Equipment

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 3035 INSTRUCTION MANUAL

Transcription:

The essentials of a highly uniform, light precipitation, hanging sprinkler system to suppress dust in such areas as arenas, barns, and industrial plants. Basic layout s that have a discharge rate of roughly 0.31 gallons per minute (GPM) at a pressure of 30 psi (at the nozzle) are installed overhead on a grid. The sprinklers should be installed about 5 feet apart along the sprinkler laterals (hose or pipe), and the laterals/lines can be anywhere from 12 to 18 feet apart. The laterals closest to the sides of the area should be 7-10 feet from the edge; the sprinklers at the ends of the laterals should be 7-10 feet from the ends of the area. Check (Non- Leak) Valve Friction Fit Figure 1 - Hanging & Check Valve Assembly The inlet ends of all the sprinkler laterals are connected to a header manifold (hose or pipe); the far ends of all the sprinkler laterals are closed, or connected to a flushing manifold if the water quality is poor. All the sprinklers may be operated at the same time if sufficient water flow and pressure is available. If there is not sufficient water and pressure to operate all the sprinklers at one time, individual sprinkler laterals or groups of laterals can be operated using manual valves, or 24 VAC valves operated by a basic irrigation controller. Each group of sprinklers that operate at the same time is called a zone. Figure 2 A TYPICAL LAYOUT: 80 x 160 Area; 6 lines; 29 heads spaced at 5 apart per line; 8.99 gpm per line; 174 heads and 54 gpm total 2

Hose and pipe sizing 2016 IRRIGATION-MART The diameter/size of hose/pipe should be selected according to the maximum flow rate (GPM) it carries; the greater the flow rate, the larger the diameter of hose/pipe required. Maximum flow rate Number of sprinklers Dia. of hose/pipe 2 GPM 6 sprinklers 0.5 4 GPM 12 sprinklers 0.75 8 GPM 25 sprinklers 1 20 GPM 65 sprinklers 1.5 Since each sprinkler has a discharge rate of roughly 0.31 GPM at 30 psi, the flow rate of any sprinkler lateral is the number of sprinklers on that lateral multiplied by 0.31 GPM. The flow rate of any zone is the total number of sprinklers multiplied by 0.31 GPM. To limit the size of sprinkler laterals required when runs are long, they can be supplied from a header manifold located near the center of the sprinkler line. Zone sizing It is important to know dependable flow rate the of water source (in GPM) and at a pressure of at least 45 psi (nozzle pressure, plus elevation loss, plus friction loss; this is discussed in more detail below under Operation and Control). This flow rate is the determining factor for how many sprinklers can be operated at one time. Sometimes it is more economical to design/operate a system using several zones even if the water source is sufficient to allow fewer zones. assembly The basic element of the system is the sprinkler. Each sprinkler should be equipped with a check valve, to prevent the system from draining and forming wet spots. The sprinkler may fit into an adapter as a friction fit. To assemble, twist the sprinkler in a screwing fashion while pressing it into the adapter. This friction fit is able to withstand at least 60 psi of pressure, although the actual operating pressure will be much lower. The sprinkler can be attached to the sprinkler lateral in several ways, chiefly determined by whether the lateral is Polyethylene (PE) hose or Polyvinyl Chloride (PVC) pipe. Polyethylene hose systems Little experience is required to install a system using polyethylene hose for the laterals. Only use Linear Low Density (LLDPE) hose, which is soft and resists UV radiation. The hose should be opaque (so algae will not grow in it). Black LLDPE hose is commonly used. Some LLDPE hose has an outer layer that is a different color (e.g., white); the color is for aesthetic reasons. 3

The LLDPE hose itself should be hung/suspended in such a way that it is relatively straight, not sagging excessively. It can be attached to a rigid structural member in the roof, or attached to a high tensile wire. Hanging sprinkler assemblies attach to the hose using barbed fittings. A hole is punched into the hose and the barbed fitting is inserted into the hole. LLPDE Hose Drop Tubing Weight LLDPE HOSE Check Valve Figure 3 - Polyethylene Hose Assembly PVC pipe systems For systems using PVC pipe as the laterals, each sprinkler is adapted to a threaded tee (slip x slip x FPT) installed on the pipe. All threaded fittings should be sealed with Teflon tape. The PVC pipe itself must be hung in such a way that it is straight, not sagging excessively, and so that the sprinklers are vertical. The pipe can be attached to a rigid structural member in the roof, or to a high tensile wire. PVC Tee 1/2 MPT Nipple 1/2 FPT x Friction Adapter Check Valve Figure 4 - PVC Pipe 4 Figure 5 - PVC Pipe Assembly

Operation and control Pressure Regulation The sprinkler system is designed to operate at about 30 psi at the nozzle. A pressure regulator will reduce the downstream pressure to a given pressure value. While it might seem reasonable to use a 30 psi pressure regulator, in fact, most control system components (like the pressure regulator) are commonly installed below eye level for easy access. Since the sprinklers are typically mounted much higher than this, more than 30 psi pressure will be required to both elevate the water to the installed height of the sprinklers, to account for friction losses, and to supply the sprinkler nozzle with 30 psi. To perform an exact calculation for required pressure, the important conversion factor is 2.31 ft. per psi. Most often a 40-50 psi pressure regulator is suitable. Filtration Most water sources can be used to supply the sprinklers, but using dirty water sources such as lakes, streams, and ponds, can be demanding. A 120 mesh or finer screen filter is recommended for all water sources, even for community/municipal supplies. Valves Dust control sprinkler systems can be operated by manual valves, or by 24 VAC automatic valves and an irrigation controller. If the water source is dirty, care must be taken in selecting automatic valves to assure that they can operate in dirty water conditions. Figure 6 - Valve, filter, & pressure regulator assy. Figure 7 - ANOTHER TYPICAL LAYOUT: 60' X 120' area; 4 lines of 21 heads and 6.51 gpm each; 84 heads and 26 gpm total 5