SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

Similar documents
BS Series Basket Strainer

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

INSTRUCTIONS PARTS LIST

FloWash. Industrial Filter Cart

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

TITAN FLOW CONTROL, INC.

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Installation Instructions JATCO Environmental Protection Tank Model J-7000

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

Yoke Block Instruction Manual

Yoke Block Instruction Manual

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

HIGH RATE BASKET STRAINER

Model ASSEMBLY and OPERATING INSTRUCTIONS

Eaton Filtration, LLC

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Accu-Tab PowerBase 3012AT by Axiall Corporation

A N C H O R T A B S N O R T H W E S T ANCHOR TAB VF. Patented. User Instructions

Rescue Ladder Basic Kit Model: LDR-BAS-CTS 18ft (5.48m)

PART Q CONTROL OF HAZARDOUS ENERGY (LOCKOUT-TAGOUT)

Accu-Tab PowerBase 3070AT by Axiall Corporation

Lockout/Tagout Training Overview. Safety Fest 2013

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

CONTENTS AIRBERTH OWNER S MANUAL I 3

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

GREIG FILTERS, INC. OPERATION MANUAL

Safety Selector Valves Dual Pressure Relief Device System

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Rescue Ladder Basic Kit Model: FS-EX243 18ft (5.48m)

AIR INLINE METAL SHEAR

Rescue Ladder Model: KT ft (5.48m)

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Eaton Filtration, LLC

Installation, Operation and Maintenance Manual

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

Rescue Ladder Model: CTB LDR-RSC 18ft (5.48m)

Accu-Tab PowerBase 3140AT by Axiall Corporation

Installation and Operating Manual

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Shell & Tube. JATCO Inc. Operating Manual

BLADDER TANK PROPORTIONING SYSTEM PRE-PIPED

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

8675/8677/8678 OWNER S MANUAL

Model 9201E Tempered Water Blending System

Accu-Tab Systems 2000 P Series by Axiall Corporation

Float Operated Level Controllers

T1-Titanium HVLP Siphon Feed Spray Gun

WHEATLEY Series 500 Swing Check Valve

Interface Devices, Inc. Hydraulic Mini Mule

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Hazardous Energy Control/Lockout

GALISO SOAP OPTION FOR PCT-ADW-D

INSTALLATION AND OPERATION MANUAL CHEMICAL BYPASS FEEDER General Instructions Regarding All Models

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

EQUIPMENT Operation Manual. Loctite Stainless Steel Poppet Valve Part Number

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Vessel Installation and Operating Manual

Energy Control Procedures Lockout/Tagout 29 CFR

444C DUAL PERFORMANCE VALUE PACK

Horizontal Bladder Tanks

Nitrogen Supply System

FRYSAFE COOKING OIL FILTRATION I&O MANUAL

453 Series Steam Heated Vaporizing Regulator

Accu-Tab Systems 1000 Series by Axiall Corporation

BINKS SG-2 PLUS TM ROTARY 2 QT. PRESSURE CUP

Model MTB-ASME Vertical Bladder Tanks

Vertical Bladder Tanks

LOCKOUT/TAGOUT PROGRAM

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Siphon vessel / Priming aid

Tsunami Breathable Air System

Model MTB-ASME Horizontal Bladder Tanks

Installation, Operation & Maintenance Manual

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

Model MTB-ASME Vertical Bladder Tanks

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

OFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS

Air Consumption Recommended Usage Siphon Feed

4-in-1 Professional Inflator Kit

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

1700ESL Kamvalok Coupler

RG2200 BC Integrated Octopus

S&S. Installation Instructions: S&S Stealth Air Cleaner Kit for Harley-Davidison Models With Stock Cable Operated Delphi EFI

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Transcription:

Now you can safely control your filtering process BROCHURE C1 SAFEsystem TM Safety Apparatus Filter Enhancement Available on Individual, Duplex or Multi-Housing ASME Code filter systems. Filtration Systems Division of Mechanical Mfg. Corporation TM

Is employee safety a primary concern? Promoting safety in the workplace is every employer s responsibility, providing safer filtration equipment is ours! You can now reduce employee exposure to potentially hazardous filtering processes with the unique and exclusive SAFEsystem option. This equipment upgrade prevents the filter vessel from being accidentally opened while in service. In addition, the vessel cannot be pressurized until both the filter lid and Safety Shield are closed. The SAFEsystem is designed to assure user compliance as a safeguard against misuse or improper operation of our filtration equipment. Our patented equipment option is available when ordering any Filtration Systems ASME Code individual, duplex or multi-housing system. Features Protective Safety Shield with Viewing Window and Retractable Locking Pin The stainless steel Safety Shield covers the entire lid and is hinged to the body of each filter vessel. This design feature protects operators from side spray, should they accidentally pressurize the filter system without properly securing the lid of the vessel. The Safety Shield has a polycarbonate viewing window for monitoring the upstream pressure and temperature gauges. A retractable locking pin mechanism prevents unintentional closure of both the Safety Shield and filter vessel lid. Filtration Systems Ball Valves All filter vessels with the SAFEsystem upgrade utilize two stainless steel, full-port, three-piece ball valves with Teflon seats and gaskets. Functioning as shut-off valves, they isolate the housing from the filtering process. Individually valved vessels on duplex or multi-housing systems operate independently, allowing continuous service during media removal and replacement. Dual-Valve Linkage Mechanism The dual-valve linkage mechanism coordinates with the Safety Shield and prevents the vessel from inadvertently being opened until the inlet and outlet valves are closed, isolating the vessel from the fluid stream. Operated by a 90-degree turn of the handle, this mechanism opens and closes both the inlet and outlet valves simultaneously. The inlet and outlet valves feeding the vessel cannot be reopened until the lid and Safety Shield are returned to the closed position. 1

TM SAFEsystem Features PROTECTIVE SAFETY SHIELD WITH VIEWING WINDOW RETRACTABLE LOCKING PIN VENT VALVE DUAL-VALVE LINKAGE MECHANISM INLET DRAIN VALVE (NOT SHOWN IN THIS VIEW) FILTRATION SYSTEMS BALL VALVES OUTLET DRAIN VALVE LOW-PROFILE, HORIZONTAL OUTLET When in the closed position, the dual-valve linkage ensures that the vessel is off-line and safe to open. If either the vessel lid or Safety Shield is left open, the filter will not operate. Inlet and Outlet Ball Valves shown in closed position, illustrating the vessel is off-line. Safety Shield is open, allowing access to the lid of the housing for media change. Inlet and Outlet Ball Valves shown in open position, illustrating the vessel is on-line. Vessel is now pressurized and operational. Note: To ensure proper operation, the SAFEsystem upgrade is available on new equipment only. Existing housings in the field cannot be retrofitted with this upgrade. 2

SAFEsystem Features and Equipment (stainless steel) Protective Safety Shield with Viewing Window and Retractable Locking Pin Filtration Systems Ball Valves, two per vessel Dual-Valve Linkage Mechanism Low-Profile Horizontal Outlet Proximity Switch Bracket Thermometer, one per vessel 1/4 Ball Valve, one per vessel (Lid Vent Port) 1/4 Ball Valve, one per vessel (Inlet Drain Port) 3/4 Ball Valve, one per vessel (Outlet Drain Port) Pressure Gauges, two per vessel (Upstream/Downstream) SAFEsystem Instruction Guide Retractable Locking Pin Mechanism Front View A Front View B A) Close-up view showing the retractable Locking Pin Mechanism in the locked position, preventing accidental closure of the Safety Shield and the Vessel Lid. B) Close-up view showing the spring-loaded, Locking Pin Mechanism released, allowing closure of the Safety Shield and/or the Vessel Lid. 3

Auxiliary Valve Ports Vent Valve The 1/4 vent valve serves as a vacuum breaker, promoting faster gravity drainage when used in conjunction with the inlet and outlet drain valves. Inlet Drain Valve The 1/4 upstream drain valve is located on the inlet elbow. After taking the vessel off-line, isolating it from the fluid stream, any unfiltered residual liquid may be drained from this port. During operation the upstream drain can also be used for sampling pre-filtered liquid. Outlet Drain Valve The 3/4 outlet drain valve, located at the base of the filter, allows users to collect any filtered liquid remaining in the vessel after it is taken off-line and prior to opening the housing for media replacement. During operation the downstream drain can also be used for sampling filtered liquid. Low-Profile Horizontal Outlet The low-profile outlet is a one-piece investment casting exclusive to the Filtration Systems product line and is an integral part of the SAFEsystem. This design feature lowers the working height of our equipment, eliminating the need for a step stool or ladder when changing filter bags. Lower working height means easier filter bag change-out for operators. As a result, ergonomic-related injuries and accidental spills may be reduced. Proximity Switch Bracket All SAFEsystem vessels include a bracket and contact for installation of a proximity switch (user furnished) to deactivate the pump. The use of a proximity switch can prevent a pump from being turned on accidentally. 4

Safety Information Checklist for Safe Operation of Pressurized Liquid Filters Filtration Systems filter vessels are designed to filter liquids under pressure, in accordance with the temperature and pressure restrictions stamped on the nameplate. The SAFEsystem upgrade does not alter the pressure and temperature specifications of our filter housings or modify standard operating procedures. 1) Follow the Instructions in the Installation, Operating & Safety Manual for Liquid Filter Housings and Filter Bags. Save both the Manual and Instruction Guide for review by all personnel who use this equipment. 2) Wear protective garments, splash protection, eye protection and respirators, as required. 3) Before pressurizing a filter vessel, always make sure you have fastened the lid hardware. 4) O-Rings are subject to wear and should be checked each time the filter vessel is opened. Replacement of O-Rings should be done prior to pressurization of the filter vessel. Be certain that the O-Ring material is both chemically and thermally compatible with the liquid being filtered. Liquid compatibility includes all materials in contact with the liquid under elevated pressures and temperatures. 5) Always relieve pressure in and to the system before loosening the lid hardware or opening the vessel lid. 6) In certain operating environments, static electrical charges or sparks may cause combustion or explosion of volatile materials. Properly ground equipment as required. 7) Removing filter media from packaging may also produce static electrical sparks. To avoid risk of combustion or explosion, never open static packaging in or around areas containing potentially flammable or explosive materials, liquids or gases. 8) Dispose of filter media properly. A filter bag that has been used with a hazardous liquid may contain residual amounts of this material and should be handled with the same safeguards that would be used in handling hazardous and/or toxic material. Media should be disposed of in accordance with federal, state and/or local laws or requirements. Improper use of pressurized filter vessels may result in injury or property damage. Any misuse or modification to our products will void both the manufacturer s warranty as well as the ASME certification of ASME Code vessels. Safety information does not by itself eliminate any danger. Information or warnings are not a substitute for proper accident prevention measures. Lethal Service Filtration Systems vessels are not designed for lethal service. Lethal Service refers to vessels containing lethal substances, poisonous gases or liquids of such a nature that a very small amount of the gas or vapor of the liquid (mixed or unmixed) is dangerous to life when inhaled. In addition, substances of this nature that are stored under pressure, or may generate pressure if stored in a closed vessel, are considered lethal. Product Identification All Filtration Systems filter vessels have a unique serial number that can be identified by our factory. Nameplates, specifying both the serial number and maximum allowable pressure and temperature rating are permanently affixed to all housings. Product Specifications With over 30 years of industry expertise and proven performance, Filtration Systems offers quality products at responsible prices. We continually strive to improve our products through ongoing research and development; therefore, we reserve the right to change specifications without notice. Intellectual Property As with all Filtration Systems patented products, the SAFEsystem offers exclusive manufacturing technology designed to complement our equipment. This company is committed to protecting its patents, trademarks, and proprietary rights from those who would wrongfully use them. The SAFEsystem is patented. SAFEsystem, Zero-Bypass and Filtration Systems are trademarks of Mechanical Mfg. Corporation. Accufit and Ultrafit are registered trademarks of Mechanical Mfg. Corporation, Filtration Systems division. Warranty Filtration Systems warrants our products to be free from defects in workmanship for a period of one year from the date of purchase, when used in accordance with our specific guidelines. Our only obligation and a customer s remedy, subject to our inspection and evaluation, shall be to replace the product or refund the purchase price. Limitation of Liability Filtration Systems shall not be held responsible or liable for any loss resulting from the resale, direct or indirect misuse, incidental or consequential damages, arising out of the use of this product. Manufactured by: Filtration Systems 1999 Mechanical Manufacturing Corporation Division of Mechanical Mfg. Corporation 10304 N.W. 50th Street Sunrise, FL 33351 USA Tel: 954-572-2700 Fax: 954-572-3401 http://www.filtrationsystems.com 5 FS/C1-99