Biochemistry Laboratory I CHEM 4401 Pipetting & Scales

Similar documents
Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Pipetting Small Volumes

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

MOLEBIO LAB #1: Microquantity Measurement

Real World Metric System

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

Using a micropipette to transfer exact liquid measurements in scientific experiments By: Nicole Hume

Pipetting and Determining Protein Concentration

How to Measure R7.1. Reference. I. Linear dimensions

MULTICHANNEL. Labnet International, Inc.

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

The use of the analytical balance, and the buret.

Inquiry Module 1: Checking the calibration of a micropipette

Pipettor. User Manual

Experiment 1 Use of Micropipettes: measuring volume accurately

BASIC LABORATORY TECHNIQUES (Revised )

Improving Pipetting Techniques

Experiment #2. Density and Measurements

How to Use: 1. Hold the pipette like you are going to shake hands with it.

BASIC LABORATORY TECHNIQUES (Revised )

LABORATORY EXERCISE I METRIC SYSTEM OF MEASUREMENT

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

SOP-111 Pipetting Small Volumes

Operating Instructions. Rainin Classic Manual Pipette

Lab Equipment ANALYTICAL BALANCE

Measuring Mass and Volume

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Fisherbrand. Finnpipette INSTRUCTIONS FOR USE PARK LANE Pittsburgh PA

LABORATORY TECHNIQUES. Pouring Liquids

CHM250 Calibration and Measurement Lab. Balance Calibration

Purpose. Introduction

CHM Introductory Laboratory Experiment (r17sd) 1/13

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Adjust the Volume Display

Chapter 2. Pipetting techniques. Guide to Pipetting

Gel Loading Practice MiniLab

ali-q TM Gravimetric Verification Procedure

Experiment 1 Basic Laboratory Operations

Good Pipetting Practice

VOLUMETRIC TECHNIQUES

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

Measurements. Metric System

Any laboratory is equipped with specific tools, equipment,

Improve pipetting results in pharmaceutical formulation by using MICROMAN E

A N F G J I C D D L A B C D E F

EXPERIMENT 1 BASIC LABORATORY TECHNIQUES AND TREATMENT OF DATA MEASUREMENTS

Technical Procedure for General Laboratory Equipment

RayPette Plus Autoclavable Pipette. User Manual

CHEM 321 Experiment 1

Recording Significant Figures

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

Hands-On Experiment Density and Measurement

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

The pipettes cover a volume range from 0.1µl to 10ml.

APPENDIX A CORRECT USE OF DIGITAL PIPETTES

Standard Operating Procedure. Air Displacement Pipette Calibration

Other languages available on our website:

BASIC LAB SKILLS: EIGHING BALANCE AND BUNSEN

Title of Manual: Specimen Collection Document Number: GPA To provide the proper collection protocol for Candida Vaginitis testing.

Transferpette. Lightweight precise rugged reliable!

Transferpette. Lightweight precise rugged reliable!

Target Density Lab SCIENTIFIC. Density Inquiry Lab Activities. Introduction. Concepts. Materials. Safety Precautions. Preparation

Calibration of Volumetric Glassware

Experiment 1 Introduction to Some Laboratory Measurements

Transferpette -8/-12

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

product manual H-1200 & H-1250 Universal and Portable Penetrometers

OXYTEMP Instructions 1

Technique Sheet 16. Using the Metric Ruler

Corning Step-R. Repeating Pipettor. Instruction Manual

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

R: The Ideal Gas Constant Pre-Lab Assignment

Laboratory Activity Measurement and Density. Average deviation = Sum of absolute values of all deviations Number of trials

1. Determining Solution Concentration

Transferpette. Single and Multichannel Pipettes

Thermo Scientific F1-ClipTip Single Channel Multichannel

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

The Ideal Gas Constant

Objective To identify a pure liquid substance using the physical properties of solubility, density, and boiling point.

EXPERIMENT 2. Laboratory Procedures INTRODUCTION

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

Basic Flows in a Microfluidic Device

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!

In case of emergency or accident: 1. Call the instructor immediately. Describe the nature of the accident or injury.

Solvent System Walkthrough

CALIBRATION AND ADJUSTMENT

Ch. 2: Tools of the Trade

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

User s Manual. Digital micro pipette for liquid handling CERTIFIED ISO9001

EXPERIMENT 1 TOOLS FOR LAB MEASUREMENT

00 Experiment: Basic Lab Techniques, Compliance of GLP and Calibration of Glassware

A Flexible, Multi-Purpose, Multi-Detector HTS Automated Platform

Transcription:

Biochemistry Laboratory I CHEM 4401 Pipetting & Scales Pipettors are one of the most basic, and most used, instruments in the biochemistry laboratory. pipettors are used to transfer small volumes of liquids, usually between 0.2 microliters (ul) and 1 milliliter (1 ml, 1000 ul). They are easy to use, but require care as they are rather expensive (~$ 250 apiece). The first thing to learn about pipettors is what liquids are NOT to be pipetted. These include strong acids, bases and very non-polar substances, all of which can damage the internal gears, gaskets and pistons. If in doubt, ALWAYS ask your instructor if it would be appropriate to use the pipettor for a given substance. Operation We will use three different pipettors, which differ in the range of volume they will pick up and dispense. The first one is known as the P-20, the 20 indicates that 20 microliters (ul) is the maximum volume it can dispense. The second is the P-200, which handles volumes between 20-200 ul and the third is the P-1000, which operates with volumes from 200-1000 ul (1 ml). The P-20 and P-200 pipettors use the same tips, which are in the smaller tip boxes and are often either yellow or clear. The P-1000 uses a larger tip, which is typically blue or clear. They are found in their own, larger tip boxes. In order to pick or dispense any volume, the pipettor must have a tip on the end of the shaft. This is done by grasping the pipettor and inserting the shaft into the open end of the appropriate tip, while it is in the box. Slight pressure from your hand on the pipettor will seat the tip. After deciding if a pipettor is the appropriate instrument for transferring a reagent, the most important thing to know about pipettors is what the values on the different pipettors mean. As indicated, the P- 20 pipettor pipets volumes between approximately 1-20 ul. If you look on the dial of the pipettor you will see a column of three values: top, middle and bottom. The top value is gauged in tens of microliters. It can have the values of 0 1 or 2, which represent ranges of 1-10, 10-20 or 20 ul, respectively. The middle value is guaged for individual microliters and the bottom value for tenths of microliters. To set a volume of, say, 14.5 ul you would turn the plunger knob on the pipettor handle until the top value is 1 (for 10) the middle value is 4 (which added to 10 makes 14) and the bottom value is.5. To set a volume less than 10 ul, you would turn the plunger knob until the top value read zero and then dial in the volume desired.

The P-200 and P-1000 operate in the same manner, except for the P-200 the 0, 1 or 2 values in the top of the column represents ranges of 0-100, 100-200 or 200 ul, respectively. The middle value represents tens of microliters and the bottom value individual microliters. You will notice that values on the bottom are hashed off in 0.2 ul increments. The P-1000 can have a reading of either 0 or 1 in the top of the column, representing a 0-1000 ul range. The middle value represents hundreds of microliters and the bottom value is gauged in tens of microliters, hashed off into 2 ul increments. Much as for the P-20, setting a pipetting volume on either the P-200 or P-1000 involves dialing the plunger knob to the desired value. Here are some examples P20 (1 to 20 ul volumes) 17.5 ul would read 2.2 ul would read 0.8 ul would read 1 0 0 7 2 0 5 2 8 P200 (20 to 200 ul volumes) 175 ul would read 24.6 ul would read 102 ul would read 1 0 1 7 2 0 5 4(.6 hash mark) 2 P1000 (200 to 1000 ul) 612 ul would read 1000 ul would read 920 ul would read 0 1 0 6 0 9 1(.2 hash mark) 0 2 To review pipettor operation : 1. The volume desired is dialed in to the pipettor by rotating the handle plunger knob (top). 2. An appropriate pipettor tip is seated onto the shaft using slight pressure on the pipettor. 3. The handle plunger knob is depressed by the thumb to the first stopping (resistance) point. 4. The tip of the pipettor tip is inserted into the liquid you wish to transfer. Slow release of pressure by your thumb draws liquid into the pipet tip. 5. The pipettor is transferred to the container where the liquid is to be dispensed. Gently insert the liquid-containing tip into the solution where it is to be dispensed. If the tube, container,etc. is empty, touch the pipet tip to the wall of the container near the bottom.

6. Depress the plunger to the very end to completely dispense the liquid. Do not release pressure on the plunger while the tip is still in the container containing the dispensed solution. This may cause solution to be drawn back into the tip, or splash out. 7. Remove the pipettor from the solution. At this point it is OK to gently release pressure on the plunger (NO Snap Releases!). 8. Eject the used tip into the waste container by depressing the button below the plunger on the top of the pipettor Procedure Practice pipetting technique by following the directions on the next page. Turn in your sheet to your Laboratory instructor when you are finished

Use ordinary tap water for all pipetting operations Biochemistry Laboratory I CHEM 4401 Pipettors & Pipetting (10 pts) 9. Which pipettor would you use to transfer the following volumes? (0.5 pt each.) Volume pipettor 650 ul 0.18 ml 68 ul 0.95 ul 110 ul 0.4 ml 7.5 ul 10.Pipet the above volumes of water onto a weigh boat on one of the analytical balances (tare between each measurement to record accurate values). Record the mass of each pipetted amount below. (0.5 pt each) Volume mass 220 ul 0.85 ml 68 ul 195 ul 19.5 ul 0.075 ml 350ul 11.Read each column below. The top cell indicates pipettor. The next three cells show the volume reading on the pipettor. Indicate in the bottom cell the value of this volume reading, in microliters (ul). (0.5 pt each.) P-20 P-1000 P-200 P-1000 P-200 P-20 1 0 0 0 1 0 9 9 5 8 8 9 5 3 7 0 2 1