MEDICAL BREATHING CIRCUIT SCAVENGER SYSTEM USER S MANUAL / INSTRUCTIONS

Similar documents
NITRONOX SCAVENGER SYSTEM USER S MANUAL / INSTRUCTIONS

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Yoke Block Instruction Manual

Yoke Block Instruction Manual

MOBILE E TANK STAND INSTALLATION AND INSTRUCTIONS

USER INSTRUCTIONS. S I L - C O N N - K I T S m a l l e r h o s e t o F l o w m e t e r L a r g e r h o s e t o V a c u u m C o n t r o l D e v i c e

PORTER INSTRUMENT COMPANY, INC.

NITRONOX USER S MANUAL

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

Porter Conscious Sedation Flowmeters and Bag Tee (Accessory)

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

STANDARD FLOWMETER USER S MANUAL

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref Rev.

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

AND OPERATION INSTRUCTIONS

Nitrous Oxide / Oxygen FLOOR MOUNTED OUTLET STATION Installation and Instructions

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

CSA Sample Draw Aspirator Adapter Operator s Manual

Model ASSEMBLY and OPERATING INSTRUCTIONS

MXR FLOWMETER USER S MANUAL

AUTOVENT 4000 VENTILATOR

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

DIGITAL MXR-D FLOWMETER USER S MANUAL

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

453 Series Steam Heated Vaporizing Regulator

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

Mirage Vista Nasal Mask

O-Two Self-Study Guide. Equinox Relieve

USER S MANUAL / INSTRUCTIONS

FLANGED TWO-PIECE BALL VALVES

Table Top and Convertible Anesthesia Machine Models: M3000 and M3100 (SHOWN WITH OPTIONAL EQUIPMENT)

RK-IR Sample Draw Aspirator Adapter Operator s Manual

M5400 Operators Manual

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

SOTR Special Operations Tactical Respirator

CPR MEDICAL DEVICES INC. OPERATING MANUAL

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

UNIVERSAL MASK TEST SYSTEM

AIR INLINE METAL SHEAR

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

FLANGED TWO-PIECE BALL VALVES

This document to be used with Hurley traditional Davits

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

Rev. B. Operating Instructions

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

Digital MDM Operations Manual

RG2200 BC Integrated Octopus

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Pressure Regulator. Instructions for Use

MODEL CALIBRATION GAS DELIVERY SYSTEM

45A, Armthorpe Road, Brampton, Ontario, Canada, L6T 5M4. Made in Canada by O-Two Medical Technologies Inc.

Instruction Manual No. 742, 8/98

U S E R M A N U A L. (CGA 870 Connection)

RAM 4021 Operation Manual

Invacare Twilight II Nasal Mask

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Pressure Regulators. Instructions for Use

Model 687 Mouse Ventilator User s Manual. Model 687 Mouse Ventilator

S&S. Installation Instructions: S&S Stealth Air Cleaner Kit for Harley-Davidison Models With Stock Cable Operated Delphi EFI

2000 lb manual winch

User manual. ZX trolley.

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

Oxygen Usage Best Practice Guide

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

Accu-Tab Systems 1000 Series by Axiall Corporation

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

AIR/OVER HYDRAULIC JACK 20 TON

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Nitrogen Supply System

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

User Manual. Quantos Automated Dosing Liquid Module

RGC-IR Remote Gas Calibrator for IR400

200 PSI COMPRESSORS - MODEL NUMBERS

100C Air Compressor Kit

COMPACT METAL bender 99826

Micro Dial-Flowmeter. Instructions for Use

Oxygen Dialflow Meter. Instructions for Use

IMPORTANT SAFETY INSTRUCTIONS

6 digital caliper with case

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Transcription:

MEDICAL BREATHING CIRCUIT SCAVENGER SYSTEM USER S MANUAL / INSTRUCTIONS Examination All components should be removed from their respective shipping containers and examined. Any omissions and/or damage should be reported to your Porter dealer immediately. User Responsibility The Medical Breathing Circuit Scavenger System (with Porter disposable Medical Breathing Circuit) is designed for use with Nitronox HD Inhalation Analgesia System (Refer to Instructions FM-1308), or an Analgesia Conscious Sedation Flowmeter (Refer to Analgesia Conscious Sedation Device Instructions) to perform in accordance with specifications herein when installed, operated and maintained as instructed in this manual. It should be carefully read and understood prior to operation and use of the scavenger system. Warnings (administration of N 2 O/O 2 conscious sedation analgesia) The Scavenger System is intended to be used by medical personnel trained in its use and the use of nitrous oxide and oxygen for medical applications. An EXPLOSION hazard exists when flammable agents are exhausted into the vacuum system (Page 5). The Scavenger Interface is supplied with a removable foam flow resistor. This foam resistor must be REPLACED every six months to help prevent the possibility of increased resistance due to particle entrapment (Page 8). Use Scavenging: Medical workers are exposed to N 2 O during administration of N 2 O/O 2 conscious sedation analgesia. Controls are effective in the patient treatment area to achieve low levels of ppm (parts per million) exposure. Controls include System Maintenance, Ventilation and Work Practices. Your accessory Scavenger System is an important part of the system of controls in medical settings. Warning: When using a single use full face mask or mouthpiece dispose of mask after use to prevent patient cross-contamination. When using sterilizable mask, follow manufacturer s sterilization instructions. Warning: Use patient observation to prevent over sedation. If a patient becomes over sedated when being delivered 100% oxygen [during an apparent loss of nitrous oxide supply], it is a definite indication of crossed lines. If crossed lines are suspected, remove the mask immediately and encourage mouth breathing. Deliver pure oxygen only if the oxygen source is independent from the suspected crossed lines area. FM-1330 Rev B 04/2018 www.porterinstrument.com/medical

Medical Breathing Circuit Scavenger System - Description The Medical Breathing Circuit Scavenger System is an Interface for the removal of patient exhaled O 2 / N 2 O gas mixtures generated from the Nitronox Inhalation Analgesia System or the Conscious Sedation Flowmeter System and Medical Breathing Circuit. The exhaled gases are routed through the Interface to a vacuum system. The Scavenger and vacuum systems provide dilution and disposal of mixed waste gases. The Scavenger System consists of components necessary to transfer patient exhaled gas mixtures to the source of vacuum. Fig. 1.1 Interface Ambient opening (foam resistor) Scavenger Interface Drain Valve Fig. 1.2 Nitronox Fig. 1.3 Porter MXR Fig. 1.4 19mm Hose The system components are: Fig. 1.5 Sentry Sedate Fig. 1.6 Gas Output Sentry Sedate A Scavenger Interface (Fig. 1.1) to connect the vacuum system with the Scavenger System. It contains: o Orifices to limit vacuum pressure and flow. o Opening to ambient to help prevent over/under pressurization from patient exhaust. o A valve to automatically drain any internal condensation. A Nitronox Demand Valve Mount (Fig. 1.2) to seal the exhaust ports of the Demand [breathing] Valve, or A Flowmeter with Bag Tee (Fig. 1.3) to deliver the Conscious Sedation mixture to the Medical Breathing Circuit (using Breathing Circuit tee. ). A corrugated magenta 19mm hose (Fig. 1.4) with one way valve to connect the Medical Breathing Circuit to the Interface. The hose is an integral part of the disposable Medical Breathing Circuit. The Interface is typically connected to the center post on a Mobile Cart or Wall (see FM-916 for E-Stand and FM-1346 for 2-Cylinder Mobile Cart). For Sentry Sedate see FM-1274 (see Fig. 1.5, Fig. 1.6; Note: A Porter Bag Tee attaches to the Gas Output Bulkhead prior to attachment of the Medical Breathing Circuit.). 2

Medical Breathing Circuit Scavenger System - Description The gas flow path through the Scavenger System starts with patient exhalation from the mask into the coaxial tubing of the disposable Medical Breathing Circuit and then to the tee of the Medical Breathing Circuit through the one-way valve into the 19 mm scavenger hose. The flow path is one-way directional and reinforced with a one-way valve. The hose leads the gas into the Scavenger Interface. The Interface is open at the top to ambient via a foam resistor. In addition, the Interface contains an internal pathway for gas passage permitting waste gas to follow a preferential path to vacuum. From the internal pathway of the Interface, the waste gas flows through a ball-type control valve to a calibrated orifice contained within the barbed vacuum connector. The final gas path is through the vacuum hose to the vacuum outlet. If vacuum flow through the calibrated orifice exceeds the exhaled flow from the patient, room air will be drawn from ambient into the vacuum system via the Scavenger Interface. Also the internal volume of the Interface acts as a surge chamber to absorb a short duration of excessive patient exhalation flow. During this short duration, excess gas will fill the Interface allowing time for the vacuum flow to exhaust the gas during the next patient inspiration. Control of scavenging vacuum flow to the vacuum source through the orifice is provided by the ball control valve. The ball valve adjusts the scavenging vacuum flow between an upper (maximum) and a lower (minimum) limit. Higher vacuum flows assist in scavenging higher levels of patient exhalation flow. An automatic relief valve is provided in the bottom of the Interface to prevent condensation from causing a water seal of any internal gas passages. This is feature operates only when condensation occurs. 3

Installation Options Mobile Stand Mount Connect the cylindrical Scavenger Interface to the center column assembly of the Mobile Stand (Figs. 2.1, 2.2). Use the mounting clips of the Interface to position the assembly on the column. Orient the Interface assembly vertically with open end (foam resistor) up and condensation relief drain valve down. Fig. 2.1 Fig. 2.2 Wall Mount: Fig. 3 1. Hold the Scavenger Interface against the wall in the desired mounting location. The 19 mm magenta corrugated hose is 2 ft. long (61 cm) and must connect to the Analgesia Conscious Sedation Device output and the Scavenger Interface. 2. Mark four mounting-hole locations on wall using the Interface mounting plates as templates. 3. Drill four holes in the locations marked: Note: For dry wall or plaster, use a suitable screw attachment method to secure against pushing and pulling of hose connections. For wooden studs, drill appropriate pilot hole, 1-1/2 inches (4 cm) deep to accept mounting screws. 4. Insert appropriate receptacle (not provided) in hole, if necessary. 5. Mount the Scavenger Interface using four screws (not provided) in the prepared locations (Fig. 3). Note: Mounting installation must be done on both the top and the bottom brackets. Fig. 3 Scavenger Wall Mount 4

Scavenger Interface Mounted on Sentry Sedate Use of template / kit Fig. 3.1 On front cover Fig. 3.2 Screws inside cover (place caps) Fig. 3.3 1. If holes are not pre-drilled, use LB-730 Plastic Template to align with Front Cover and mark hole locations and drill appropriate pilot holes or use the self-tapping feature of the included mounting screws (See Fig. 3.1). 2. The Scavenger Interface mounts on the Front Cover of the Sentry Sedate using 4 screws through mounting plates and 4 holes in Front Cover (See Fig. 3.2) 3. Protective caps for the screw ends inside the cover are provided (See Fig. 3.3 Hose Connections: Fig. 4 1. Connect the 19 mm magenta corrugated scavenger hose of the disposable Medical Breathing Circuit to the Interface (Fig. 4.1). 2. Connect vacuum hose between the vacuum source inlet (using appropriate connection such as DISS, QUICK Connect, etc.) and the barbed outlet connector on the Interface. Push the tubing on the barb so that two to three barbs are covered. Note: Hold the barbed outlet while pushing tubing onto barb to reduce excess strain. 19mm Hose Connection (remove cap) Barbed Outlet Connection (remove cap) Warning An explosion hazard exists when flammable agents are exhausted into the central vacuum system.1 Fig. 4.1 Fig. 4 5

Operation 1. Connect Wall, Mobile E-Stand, or Sentry Sedate gas supplies [O 2 and N 2 O] to Nitronox or Flowmeter. Connect vacuum source to Scavenger Interface barb. 2. Ensure Interface black lever valve is in the on [open] position before beginning procedure. For best scavenging vacuum flow, turn the ball valve lever to the vertical (full on position; 6 o clock) (Fig. 5). Note: With the ball valve lever in the full on position, the vacuum flow should accommodate the exhaust gas from all normal breathing patterns (30 35 LPM, maximum). 3. If the overall demand for vacuum is overloading the central system, the ball valve may be slightly Fig. 5 throttled to reduce vacuum flow by turning the ball lever to the 7 to 8 o clock position. Note: With the lever in the mid 7 to 8 o clock position, the ball valve will still allow a vacuum flow of 8 to 12 LPM, minimum. Minimal flow position is 9 o clock. 4. Removal of ball valve lever to lock-in adjustment position: Remove holding screw and ball valve lever after adjustment to full on position [eliminates inadvertent lever position change]. To place lever back again for adjustment capability, take care to slide into full on, 6 o clock position and assure lever range is from 6 o clock to 9 o clock. 5. The Interface is designed so that condensed water vapor should discharge from the bottom, if its volume exceeds 40 to 50 cc/ml. 6. Read and follow the directions in the Instructions FM-1329: Using the Porter Medical Breathing Circuit with Nitronox (Demand Flow) or with Analgesia Conscious Sedation (Continuous Flow) Devices. Maintenance Cleaning We recommend the use of an approved disinfectant or surface wipe for the dental / medical environment for cleaning the outside of the Scavenger System. Do not spray disinfectant directly onto housing. Spray disinfectant into disposable towel and wipe unit thoroughly removing excess disinfectant to eliminate buildup. CAUTION: Introduction of moisture or other contaminants into this device may result in defective operation. CAUTION: Never oil or grease any part of this system (minimize fire or explosion potential). Field Replacement Foam Resistor 1. Replacement of the foam flow resistor PN 61962300 (refer to Figure 1.1) approximately every six months. Warning The foam flow resistor is to be replaced approximately every 6 months to help prevent the possibility of increased resistance due to particle entrapment. 2. Pull the foam resistor (one inch, diameter, by six inches, long) from the top center hole of the Interface cylinder with the use of forceps or needle nose pliers. 3. Insert a new foam resistor into the Interface top-center hole until the top of the foam resistor reaches the lower edge of the horizontal vent holes. Replacement Parts: Contact Porter or your authorized Porter Dealer 6

Development of Delivery Protocols It is the responsibility of the medical establishment and the medical professional to develop and establish specific delivery protocols. The Nitronox Inhalation Analgesia System is designed to deliver a fixed concentration of 50% nitrous oxide and 50% oxygen on the demand flow [self-administration] principle. The Conscious Sedation Flowmeter with Bag Tee is designed to deliver a variable concentration of nitrous oxide and oxygen on the continuous flow principle. The medical professional will turn on and observe the operating indicators of the device. In order to receive the analgesic, the patient may assist [Nitronox: will selfadminister] by holding the face mask firmly in place during the procedure. With the face mask sealed every time the patient takes a breath, the patient will receive the full effect of the mixed gas through the face mask [Nitronox: the patient inhalation will open the demand valve]. Common procedures conducted with Nitrous Oxide Oxygen Analgesia Conscious Sedation. Ideal for minimally invasive procedures where there is a desire for pain management to reduce anxiety or to deliver minimal sedation. The Nitronox Inhalation Analgesia System and the Conscious Sedation Flowmeter delivery is considered transient (less than 60 minutes) in terms of continuous use when providing Analgesia (pain management), or Minimal Sedation. However, a procedure or medical condition that occurs over the course of many hours, also is considered to be using transient delivery, in that, given administration techniques, the patient will be unlikely to hold the face mask to the face continuously for over 60 minutes. For example, a woman in labor may safely use conscious sedation (typically using a Porter Demand Flow Nitronox device) in a transient self-administration mode over the course of several hours as secondary labor and end labor stages are experienced. The upper limit of the number of hours of this described transient delivery is at the determination of the medical professional. Patient Population (Adult and Pediatric): Used to deliver a gas mixture to a conscious spontaneously breathing patient who is awake, alert and cooperative and requires relief from minimal to moderate pain and is under the continuous supervision of a healthcare professional. Age/Weight limitations: see Relative Contraindications (at the determination of medical professional). Note: Porter recommends the use of a disposable full face mask (DEHP-free and Latex-free) that is biocompatible for medical use. Follow manufacturer s instructions. The disposable mask materials have been chosen by the medical device manufacturers of the masks intended for medical usage. Many establishment protocols also call for the use of a bacterial filter. Follow manufacturer s instructions. 7

Continuous Flow vs. Demand Flow Devices Equipment to deliver nitrous oxide and oxygen analgesia conscious sedation are often categorized as demand flow or continuous flow devices. The Conscious Sedation Flowmeter is a continuous flow device, while the Porter Nitronox is a demand flow device. Specific delivery protocols will be established for the two categories of equipment. The differences center around self-administration for demand flow devices vs. direct administration by medical professionals for continuous flow devices. Also, continuous flow devices typically allow the administration of variable concentrations of nitrous oxide and variable flow rates of delivered mixture. However, some establishments have developed specific protocols for delivery with continuous flow devices, where the medical professional is able to adjust to deliver various percentage mixes, where, with supervision, the delivery could be described as selfadministration, in that the patient will hold the full face mask to the face. Do not use a strap with the full face mask. *Basic Delivery Technique [for Continuous Flow Applications with variable percentage delivery]: Practice titration. Titration is a method of administering a substance by adding definitive amounts of a drug until an endpoint is reached. For nitrous oxide / oxygen (N 2 O) / O 2 ) sedation, N 2 O is given in incremental doses until a patient has reached a comfortable relaxed state of sedation. The ability to titrate N 2 O is a significant advantage because it limits the amount of drug to that which is required by the patient. If titration is done properly, the patient does not receive any more of the drug than is necessary. The amount of N 2 O required by a patient on any given day or time varies. 1 For information on titration, a most valuable resource for the practitioner is the Handbook of Nitrous Oxide and Oxygen Sedation 1, written by Clark and Brunswick and published by Mosby (www.mosby.com). This text is a concise and contemporary guide for nitrous oxide / oxygen administration. SIDE EFFECTS & CONTRAINDICATIONS The medical professional should establish proper evaluation of Side Effects & Contraindications for the individual applications. 8

Scavenger System Specifications Note: Porter may apply technical advances whenever it is desirable. Specifications are subject to change WITHOUT NOTICE. Porter should be contacted for current information. Materials of Construction - Plastics: ABS, PVC, Polyethylene, Nylon Dimensions: Diameter Length Scavenger Interface 2-1/2 (6.4 cm) 20 (50.8 cm) Scavenger Hose (19 mm) 19 mm, ID 24 (61 cm) Vacuum Hose 3/8 (9.5 mm), ID As Required Vacuum Source: Pressure -10 to -21 Hg (-250 mm to -533 mm Hg) Interface Flow: Ball Valve Full Vertical Ball Valve 45º Position (Max. Flow) 30 35 LPM (Min. Flow) 8 12 LPM Relief Valve (Condensation): Relief Volume Retention Volume 40 50 cc/ml 5 10 cc/ml Ambient Temperature Limits: Minimum 40ºF (5ºC) Maximum 140ºF (60ºC) 9

CERTIFICATE OF WARRANTY THIS WARRANTY IS GIVEN IN PLACE OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE. Under no circumstances shall Parker Hannifin Corporation be liable for incidental or consequential damages as those terms are defined in the uniform commercial code. Parker Hannifin Corporation, Porter Instrument warrants that each product or part shall be free from defects in workmanship and materials, under normal use and with appropriate maintenance, for one (1) year from the date of delivery to customer unless otherwise specified in writing. All rubber and plastic parts and accessories are warranted under the same conditions for a period of ninety (90) days from date of purchase. No statement or claim about the product by any employee, agent, representative, or dealer of Parker Hannifin Corporation shall constitute a warranty by Parker Hannifin Corporation or give to rise to any liability or obligation of Parker Hannifin Corporation. Parker Hannifin Corporation shall not be liable for any damage, injury or loss arising out of the use of the product, whether as a result of a defect in the product or otherwise, if, prior to such damage, injury or loss, the product was (1) damaged or misused; (2) repaired, altered or modified by persons other than Parker Hannifin Corporation; (3) not installed in strict compliance with applicable codes and ordinances; or (4) not installed by an authorized Parker Hannifin Corporation dealer. Parker Hannifin Corporation's obligation for breach of this warranty, or for negligence or otherwise, shall be strictly and exclusively limited to the repair or replacement of the product or part. This warranty shall be void on any product on which the serial number has been altered, defaced or removed. ORDERS All orders are to be made through authorized Parker Hannifin Corporation distributors. All billing will be done through said distributors. Direct orders will be handled through the authorized local dealer as determined by Parker Hannifin Corporation. RETURNS All returned merchandise will be handled through the local Parker Hannifin Corporation distributor. No returns will be accepted unless authorized in writing by Parker Hannifin Corporation and accompanied by the original shipping invoice. All returns are subject to restocking charge. Policies subject to change without notice. The Quality System for Porter Instrument is certified to ISO 13485. The scope of our registration is: The design, manufacture, distribution and servicing of Nitrous Oxide Oxygen Sedation Flowmeters, Gas Scavenging Systems, Gas Distribution Systems for use by a physician, dentist or licensed Healthcare Professional. Visit our website: www.porterinstrument.com for additional information. To download a User s Manual: www.porterinstrument.com/resources-dental choose Manuals tab This product complies with the Medical Directive (93/42/EEC). A Declaration of Conformity in accordance with the directive has been made and is on file. European Communities should contact the Authorized Representative listed below regarding any Medical Device Directive (MDD) inquiries. Contact Name: Parker Hannifin Ltd Instrumentation Products Division Mailing Address: Riverside Road, Pottington Business Park Barnstaple, EX 31 1NP, England Phone +44 (0) 1271-313131 Fax: +44 (0) 1271-373636