S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

Similar documents
S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

TP1 and TP2 Temporary Cone Shaped Strainers

PV4 and PV6 Piston Valves

DF1 and DF2 Diffusers

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

S and SF Inverted Bucket Steam Traps

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

TSS21 Sealed Thermostatic Steam Tracer Trap

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Dri-Line Mk3 Monnier Compressed Air Drain Trap

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

FV Flash Vessel Installation and Maintenance Instructions

AVC32 Carbon Steel Air Vent for Steam Systems

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

CP10 Sensor Installation and Maintenance Instructions

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

AVM7 Stainless Steel Thermostatic Air Vent

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

DCV6 Disc Check Valve

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

CA10S, CA14 and CA14S Air and Gas Traps

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

CVS10 Sanitary Check Valves

CA44, CA44S, CA46 and CA46S Air and Gas Traps

APT14, APT14HC and APT14SHC Spares 2

MF2M Monnier Miniature Compressed Air Filter

CS10-1 Stainless Steel Clean Steam Separator

Manual Actuated Boiler Blowdown Valves

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

SRV66 Sanitary Pressure Reducing Valve

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

TW Temperature Control Valve

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions

Airodyn, BRair and BRoil Compressed Air Drain Traps

MFP14-PPU (Vented) Automatic Packaged Pump Units

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

ML3M Monnier Miniature Compressed Air Lubricator

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

BCV31 DN40 - Blowdown Control Valve

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

PC10HP Pipeline Connector (ASME 600)

Spirax Compact FREME Flash Recovery Energy Management Equipment

SRV2S Pressure Reducing Valve

M70i ISO and M80i ISO Stainless Steel Ball Valves for Sanitary Systems Installation and Maintenance Instructions

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

BRV71 and BRV73 Pressure Reducing Valves

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

Vane Flow Switches Colima FLU Series

BCV31 DN20 - Blowdown Control Valve

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

BDV1 and BDV2 Blowdown / Depressurisation Valves

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

M111 Spiraflo Transducer

BPT13 Balanced Pressure Thermostatic Steam Traps

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions

SCA Series Inverted Bucket Steam Traps

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

Thermocirc Installation and Maintenance Instructions

QuickHeat TM Packaged Heat Exchanger Solutions

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

RJ check valves Installation and Maintenance Instructions

BDV60 Blowdown Vessel Installation and Maintenance Instructions

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

BSA and BSAT Bellows Sealed Stop Valves Installation and Maintenance Instructions

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

595-K/L and 596-K/L Series Self Operated Valves Installation and Maintenance Instructions

Standard Pressure Powered Pump Packaged Units to Size 3 x 2 Type PPEC, PTC & PTF with vented and ASME coded receivers

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

LP31 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance

PC3000, PC3001 and PC4000, PC4001 Pipeline Connectors

STERI-TROL Clean Service 'S' Series Two-port Control Valves DN15 (½") to DN100 (4")

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

SRV461S and SRV463S Stainless Steel Direct Acting Pressure Reducing Valves

LP10-4 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance IM-P402-92

PC3_ and PC4_ Pipeline Connectors

BCVi43 Blowdown Control Valve

Transcription:

PREVIOUS REFERENCE NO. IMP02355 0231150/13 IMF0501ENISS2 CMGT S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6. Maintenance 7. Spare parts Copyright 2018 IMF0501ENISS2 CMGT 1 Printed in France

2 IMF0501ENISS2 CMGT

1. Safety information Safe operation of these products can only be guaranteed if they are properly installed, commissioned, used and maintained by qualified personnel (see Section 1.11) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. Warning The inspection plug gasket on the S2, S3, S12 and S13 and the bottom cover gasket on the S5 and S6 contain a thin stainless steel support ring which may cause physical injury if not handled and disposed of carefully. 1.1 Intended use Referring to the Installation and Maintenance Instructions, nameplate and Technical Information Sheet, check that the product is suitable for the intended use/application. The products listed below comply with the requirements of the Pressure Equipment Directive (PED) and carry the when so required. The products fall within the following Pressure Equipment Directive categories: mark S1 S2 S3 S5 and S6 16 bar g 16 bar g 16 bar g 50 bar g Product Group 1 Gases Group 2 Gases Group 1 Liquids Group 2 Liquids DN15 DN20 SEP SEP SEP SEP DN25 2 1 SEP SEP DN32 DN40 1 SEP SEP SEP DN50 2 1 SEP SEP DN40 1 SEP SEP SEP DN50 DN80 2 1 SEP SEP DN100 DN150 3 2 2 SEP DN200 2 1 2 SEP DN15 SEP SEP SEP SEP DN20 DN25 2 1 SEP SEP DN32 DN50 3 2 2 SEP IMF0501ENISS2 CMGT 3

S7 and S8 S12 S13 14 bar g Product 20 bar g and 23 bar g 25 bar g 25 bar g 25 bar g Group 1 Gases Group 2 Gases Group 1 Liquids Group 2 Liquids DN65 DN125 3 2 2 SEP DN150 DN200 4 3 2 SEP DN250 DN350 4 4 2 SEP DN65 DN80 3 2 2 SEP DN100 DN150 4 3 2 SEP DN200 DN300 4 4 2 SEP DN350 4 4 2 1 DN65 DN80 3 2 2 SEP DN100 DN150 4 3 2 SEP DN200 DN250 4 4 2 SEP DN300 DN350 4 4 2 1 DN32 DN40 1 SEP SEP SEP DN50 2 1 SEP SEP DN40 1 SEP SEP SEP DN50 DN80 2 1 SEP SEP DN100 DN125 3 2 2 SEP DN150 DN200 3 2 2 SEP i) The product has been specifically designed for use on steam and compressed air which are in Group 2 of the above mentioned Pressure Equipment Directive. ii) Check material suitability, pressure and temperature and their maximum and minimum values. If the maximum operating limits of the product are lower than those of the system in which it is being fitted, or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence, ensure a safety device is included in the system to prevent such overlimit situations. iii) A number of products are supplied for the intention of the end user (or agent thereof) modifying the flange configuration from that supplied. It is the responsibility of the organisation carrying out the modification to do so in accordance with the internationally recognised flange standards and to ensure that the design rating and operation of the product are not compromised. Spirax Sarco will not be held responsible for any unapproved modification or consequential liability resulting in failure to observe these requirements. iv) Determine the correct installation situation and direction of fluid flow. v) Spirax Sarco products are not intended to withstand external stresses that may be induced by any system to which they are fitted. It is the responsibility of the installer to consider these stresses and take adequate precautions to minimise them. vi) Remove protection covers from all connections and protective film from all nameplates, where appropriate, before installation on steam or other high temperature applications. 4 IMF0501ENISS2 CMGT

1.2 Access Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting to work on the product. Arrange suitable lifting gear if required. 1.3 Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. 1.4 Hazardous liquids or gases in the pipeline Consider what is in the pipeline or what may have been in the pipeline at some previous time. Consider: flammable materials, substances hazardous to health, extremes of temperature. 1.5 Hazardous environment around the product Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery. 1.6 The system Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? Dangers might include isolation of vents or protective devices or the rendering ineffective of controls or alarms. Ensure isolation valves are turned on and off in a gradual way to avoid system shocks. 1.7 Pressure systems Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that the system has depressurised even when the pressure gauge indicates zero. 1.8 Temperature Allow time for temperature to normalise after isolation to avoid danger of burns. 1.9 Tools and consumables Before starting work ensure that you have suitable tools and/or consumables available. Use only genuine Spirax Sarco replacement parts. 1.10 Protective clothing Consider whether you and/or others in the vicinity require any protective clothing to protect against the hazards of, for example, chemicals, high/low temperature, radiation, noise, falling objects, and dangers to eyes and face. 1.11 Permits to work All work must be carried out or be supervised by a suitably competent person. Installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal 'permit to work' system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post 'warning notices' if necessary. IMF0501ENISS2 CMGT 5

1.12 Handling Manual handling of large and/or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done. 1.13 Residual hazards In normal use the external surface of the product may be very hot. If used at the maximum permitted operating conditions the surface temperature of some products may reach temperatures of 300 C (572 F). Many products are not selfdraining. Take due care when dismantling or removing the product from an installation (refer to Section 6 'Maintenance instructions'). 1.14 Freezing Provision must be made to protect products which are not selfdraining against frost damage in environments where they may be exposed to temperatures below freezing point. 1.15 Disposal Unless otherwise stated in the Installation and Maintenance Instructions, this product is recyclable and no ecological hazard is anticipated with its disposal providing due care is taken. 1.16 Returning products Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to Spirax Sarco they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous. 1.17 Working safely with cast iron products on steam Cast iron products are commonly found on steam and condensate systems. If installed correctly using good steam engineering practices, it is perfectly safe. However, because of its mechanical properties, it is less forgiving compared to other materials such as SG iron or carbon steel. The following are the good engineering practices required to prevent waterhammer and ensure safe working conditions on a steam system. Safe Handling Cast Iron is a brittle material. If the product is dropped during installation and there is any risk of damage the product should not be used unless it is fully inspected and pressure tested by the manufacturer. 6 IMF0501ENISS2 CMGT

Prevention of water hammer Steam trapping on steam mains: 30 50 metre intervals Gradient 1:100 Gradient 1:100 Steam Steam Trap set Trap set Trap set Condensate Condensate Condensate Steam Mains Do's and Don'ts: Flow Flow Steam Steam IMF0501ENISS2 CMGT 7

Prevention of tensile stressing Pipe misalignment: Installing products or reassembling after maintenance: 1 3 7 1 3 5 6 4 4 2 2 8 Do not over tighten. Use correct torque figures. Flange bolts should be gradually tightened across diameters to ensure even load and alignment. Thermal expansion: Guides Short distance Fixing point Axial movement Axial movement Guides Guides Limit rods Small lateral movement Large lateral movement Medium distance Fixing point Limit rods Small lateral movement Large lateral movement Guides 8 IMF0501ENISS2 CMGT

2. General product information 2.1 General description The products detailed are all baffle type separators used for the removal of entrained liquids in steam, compressed air and gas systems. We recommend the fitting of insulating jackets to improve the performance of the separator. Note: For additional product data see the following Technical Information Sheets. Type Material Pressure rating Sizes Connections TI reference S1 SG iron PN16 ½", ¾" and 1" Screwed TIP12801ENISS1 S2 Cast iron PN16 1¼", 1½" and 2" Screwed TIP12901ENISS1 S3 Cast iron PN16 DN40 DN200 Flanged TIP13101ENISS1 S5 Carbon steel PN50/ASME 300 DN15 DN50 S6 Austenitic stainless steel 316L PN50/ASME 300 DN15 DN50 Screwed and Flanged Screwed and Flanged TIP13301ENISS1 TIP13401ENISS1 S7* Carbon steel PN16 and PN40 DN65 DN350 Flanged TIP13502ENISS1 S8* Austenitic stainless PN16 and PN40 DN65 DN350 Flanged TIP13601ENISS1 S12 SG iron PN25 1¼", 1½" and 2" Screwed TIP13001ENISS1 S13 SG iron PN25 DN40 DN200 Flanged TIP13201ENISS1 * Note: The S7 and S8 separators are designed and manufactured in accordance with EN 13445:2002 'Unfired Pressure Vessels'. S3 S13 S1 S2 S12 Fig. 1 Fig. 2 Fig. 3 S5 S6 S7 S8 Fig. 4 Fig. 5 IMF0501ENISS2 CMGT 9

3. Installation Note: Before actioning any installation observe the 'Safety Information' in Section 1. Referring to the Installation and Maintenance Instructions, body markings, nameplate (if fitted) and Technical Information Sheet, check that the product is suitable for the intended installation. 3.1 Check materials, pressure and temperature and their maximum values. If the maximum operating limit of the product is lower than that of the system in which it is being fitted, ensure a safety device is included in the system to prevent overpressurisation. 3.2 Determine the correct installation situation and the direction of fluid flow. 3.3 Remove protective covers from all connections and the protective film from all nameplates, where appropriate, before installation on steam or other high temperature applications. 3.4 The separators may be lagged if required. Important installation note for the S1, S2, S3, S12 and S13 separators: Install in a horizontal pipeline with the drain directly below. To ensure that any separated liquid is drained away quickly, a suitable liquid drainer or steam trap must be connected to the drain. Isolation valve S13 separator Strainer Float trap Fig. 6 Separator on a steam line 3.5 Installation for the S5 and S6 Install in a horizontal pipeline with the drain directly below. To ensure that any separated liquid is drained quickly, a suitable liquid drainer or steam trap must be connected to the drain connection. A float type trap is recommended. For those steam systems where air can be present, air can collect in the upper portion of the separator. In this situation a suitable air vent should be connected to the air vent connection. If an air vent is not being fitted then the connection must have the plastic transit protection plug removed and must have a carbon steel class 3000 lb plug fitted. 10 IMF0501ENISS2 CMGT

S5 separator Isolation valve Strainer Float trap Fig. 7 3.6 Installation for the S7 and S8 Install in a horizontal pipeline with the drain directly below. All sizes are fitted with support brackets which can be used to minimise piping loads. Each bracket has two drilled holes. To ensure that any separated liquid is drained quickly, a suitable liquid drainer or steam trap must always be connected to the drain connection. A float type trap is recommended. For those steam systems where air can be present, air can collect in the upper portion of the separator. In this situation a suitable air vent should be connected to the air vent connection. If an air vent is not being fitted then the connection must have the plastic transit protection plug removed and a carbon steel class 3000 Ib plug fitted. Air vent S7 separator Isolation valve Strainer Fig. 8 Separator on a steam line FT or CA trap IMF0501ENISS2 CMGT 11

4. Commissioning After installation or maintenance, ensure that the system is fully functioning. Carry out tests on any alarms or protective devices. Fig. 9 Heat transfer processes and valve protection Fig. 10 Compressed air distribution 5. Operation Separators are designed to gather together small droplets of entrained liquids and then separate them from the gas/vapour flow. The relatively heavy droplets impinge on the internal baffles and are then directed to the separator drain connection and removed from the system using a steam trap, or when used on air or gas distribution system, a liquid drainer. 12 IMF0501ENISS2 CMGT

6. Maintenance Note: Before actioning any maintenance programme observe the 'Safety information' in Section 1. Warning There are no internal components that require maintenance. 4 * Fig. 11 S1 Table 1 Recommended tightening torques Separator Item Size or mm N m (lbf ft) S1 4 ½" ¾" 1" 7/16" ½" 9/16" ¼" UNF x ¾" 5/16" UNF x ¾" 3/8" UNF x ¾" 12 28 40 14 32 50 (9 (21 (30 10) 24) 37) IMF0501ENISS2 CMGT 13

2 * Warning There are no internal components that require maintenance. Fig. 12 S2, S3, S12 and S13 Table 2 Recommended tightening torques Separator Item Size or mm N m (lbf ft) S2 2 2" S3 2 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 46 A/F 46 A/F M56 M56 150 150 165 165 (110 (110 S12 2 2" 46 A/F M56 150 165 (110 121) S13 2 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 46 A/F 46 A/F 46 A/F M56 M56 M56 150 150 150 165 165 165 (110 (110 (110 121) 121) 121) 121) 121) 14 IMF0501ENISS2 CMGT

Support bracket 5 * Fig. 13 S5 and S6 Fig. 14 S7 and S8 Table 3 Recommended tightening torques Separator Item Size N m (lbf ft) S5 S6 5 DN15 DN50 46 A/F 180 200 (133 150) 7. Spare parts There are no spare parts required or available for these components. IMF0501ENISS2 CMGT 15

16 IMF0501ENISS2 CMGT