LogIT Dissolved Oxygen Probe

Similar documents
Introduction The Smart Q Oxygen Adaptor enables an Oxygen electrode to be connected to an EasySense unit.

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

PRODUCT SHEET. Order probe only as RXPROBE02

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

DISSOLVED OXYGEN SENSOR BT34i

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Dissolved Oxygen/Temp Waterproof Tester

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

STERILIZABLE DISSOLVED OXYGEN SENSORS

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

Oxygen Sensor with Electrode

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Heavy Duty Dissolved Oxygen Meter

NEULOG OXYGEN LOGGER SENSOR GUIDE

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Aerobic Respiration. Evaluation copy

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

HI 9143, HI 9143M HI 9145

Dissolved Oxygen Sensor

Dissolved Oxygen Probe (Order Code DO-BTA)

12mm Dissolved Oxygen Sensor Care and Use Instructions

SS32L Dissolved O 2 Probe

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

Dissolved Oxygen Probe (Order Code DO-BTA)

Vinmetrica Dissolved Oxygen System User Manual

Dissolved Oxygen in Water. Evaluation copy. Table 1. Temperature Range ( C) Trout Smallmouth bass Caddisfly larvae

BI-680 Online Dissolved Oxygen Controller Instruction Manual

QUICK START GUIDE TO DRINKING WATER MONITORING

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

Unisense In Situ UniAmp Connector System

Experiment C-6 Gas Solubility

Radnoti Liver Perfusion System

D-OptoLogger Dissolved Oxygen Logger Operation Manual

Optical Dissolved Oxygen Meter

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

Instruction Manual MicroChem 2 Chlorine Probes Series CL4000

Free Chlorine Sensor For additional information, please visit our website at

Bante904 Benchtop Conductivity/Dissolved Oxygen Meter Instruction Manual

Columbus Instruments

HI 2314 HI 2315 HI 23151

OxyProbe II Instruction Manual

Instruction Manual SWIMMINGPOOLCHEMICALS.CO.UK

MEASUREMENT OF TOTAL PACKAGE OXYGEN (TPO) AT BOTTLING

OXYGEN CONSUMPTION AND TEMPERATURE IN THE AQUATIC ENVIRONMENT

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

MEC OEM. User Manual. Commercial in Confidence

TQC Bresle Chloride test 2008

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

MODEL GT820 OXYGEN SENSOR

OXYGEN CONSUMPTION AND TEMPERATURE IN THE AQUATIC ENVIRONMENT

Instruction Manual HI 9146 Dissolved Oxygen and Temperature Meter

T02.0.3X.6C-06 Page 1 of 6. Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP

MARTINI. instruments. THANK YOU FOR CHOOSING. Sales and Technical Service Contacts:

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Instruction Manual DO 6. Economy Hand-held Dissolved Oxygen Meter. 68X Rev 2 Apr 08. Technology Made Easy... Part of Thermo Fisher Scientific

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

A LAZAR LABORATORIES HANDBOOK DISSOLVED OXYGEN PRIMER

EC214 EC215 - EC215R Bench Conductivity Meters

Elcometer 138. Bresle Kit and Patches. Operating Instructions

SAUTER FK Version /2016 GB

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

ANALOX O2 PORTABLE OPERATORS MANUAL

Oxygen Measurement Systems High Reliability and Wide Application Coverage

PAPR Flow Tester. instructions. part no WARNING

Optical Dissolved Oxygen Meter

O2 Portable. User Manual

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Oxygen Meter User Manual

9A5N Solid State CW Paddle

Evaluation copy. Vapor Pressure of Liquids. computer OBJECTIVES MATERIALS

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

Fish Respiration and Q 10

OxiQuant S. Operating Instructions

Refillable ORP/Redox Probe: Model MTC30101 or MTC30103

New product release. Universal Rebreather Monitor (URBM) Single O2 cell and Dual HP package

130 SSP Soluble Salt Profiler

User Manual. MagnaMaster and ChloroMaster Electrolytic Chlorinator.

Quick Start Guide LIQ-QSG-499AOZ, Rev M July Rosemount 499AOZ. Dissolved Ozone Sensor

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Membrane covered optical CO 2 sensor

Vernier Optical DO Probe (Order Code ODO-BTA)

Elcometer 138. Bresle Kit and Patches. Operating Instructions

OPERATING INSTRUCTIONS Sherlock Chamber Testing System

PRECISION DISSOLVED OXYGEN MEASUREMENT SYSTEMS

Vapor Pressure of Liquids

PERME- OX2/230 Oxygen Transmission Rate test system

Experiment B-3 Respiration

Transcription:

LogIT Dissolved Oxygen Probe INTRODUCTION The LogIT Dissolved Oxygen Probe (DO2) has been designed especially for LogIT and is easy to set up and use. It features simple single control calibration and requires no battery as the membrane is polarised by an internal rechargeable cell. The unit is designed to measure 0 to 200% Saturation with automatic temperature compensation. It has also been specially designed to work alongside the LogIT ph Amplifier and standard ph electrode thus avoiding any interference problems which can occur with electrochemical devices. The probe itself is based on the Clarke cell principle using polarographic measuring technique. As such it uses a KCl electrolyte contained by a semi-permeable membrane. As with any polarographic oxygen sensor, the measurement is dependent upon temperature in two ways. The diffusion of oxygen across the membrane is temperature dependent and is expressed by the temperature coefficient of the membrane. This temperature variation is corrected in the LogIT adapter. In addition the solubility of oxygen in solution is temperature dependent and is expressed by means of a solubility coefficient. This also varies with dissolved salts. CONTENTS LogIT DO2 adapter LogIT DO2 electrode 3 membranes A 50 ml bottle of electrolyte (KCl solution) with easy pour lid Spare membranes and KCI is available as a separate kit (DCP ref D100107) Polishing paper (crocus paper) for anode. EXAMPLE APPLICATIONS Effect of temperature change on respiration rates e.g. of locusts, yeast or maggots Oxygen in fermentation Change in oxygen content of inhaled and exhaled air Oxygen levels in ponds in relation to depth Photosynthesis. ASSEMBLY OF ELECTRODE Seal Anode Cathode Membrane Holder Rubber Sleeve 1

1. Hold membrane module in a vertical position and fill to half full with electrolyte. Ensure that no bubbles are trapped in the electrolyte. 2. If bubbles are trapped simply flick the module with a finger to dislodge them. 3. Ensure electrode is clean and free from grease 4. Hold electrode vertically down and screw membrane module up until the electrolyte is emitted. Very slowly screw the membrane module up until it is almost completely fitted. Then unscrew slightly to release any pressure. Finally screw membrane fully onto the electrode until it is just tight. Do not over tighten. 5. Check that the membrane is not pressurised. It should not be bulging out away from the cathode. 6. If the electrode is not going to be used immediately place the rubber cover provided on the end to protect the membrane - see Care and Maintenance instructions. USING THE SENSOR Carefully remove the rubber cover on the membrane if fitted, if difficult to remove gently twist in a clockwise direction to avoid unscrewing the membrane holder. The membrane is very thin and care should be taken not to damage it. The LogIT Dissolved Oxygen Probe does not use batteries, the membrane being polarised by an internal rechargeable cell, so the adapter has to be charged before use. However, all electrodes of this type require polarising and so the LogIT sensor is designed to charge and polarise at the same time - this process takes approximately 10-20 minutes, depending on the initial state. To charge/polarise the sensor you simply plug it into a data logger and ensure that the data logger is on. To charge the interface and take readings for calibration follow the instructions for the data logger you are using. In air the reading will be constant. In water the diffusion of oxygen through the water will cause a stir effect. This means that if the water is not stirred the reading will fall as a depletion layer is formed around the electrode. LIVE - Real Time logging (connected to computer) If a CheckIT display is available plug it into the LIVE, connect the sensor and charge/calibrate as per instructions. When charged/calibrated connect the LIVE to the computer and run your logging software as normal. If a CheckIT is not available connect the LIVE to the computer in the normal way for logging and run the data logging software you use. Select the software s Test mode (if available) - this ensures that the LIVE remains on as the computer displays a readings constantly taken from LIVE. If your software does not have a test facility you will need to log data, using bars or graph. 2

DataMeter 1000 - Real Time and remote data logging If running on internal batteries ensure that you turn the DataMeter on by holding down the Green key (puts DataMeter in meter mode, indicated by a flashing m in the bottom left corner of the display). Connect the sensor and charge/calibrate as per instructions. Before you commence remote data logging quickly turn DataMeter off using the red button then turn it on by pressing any button - this takes the DataMeter out of meter mode so that the DataMeter will automatically turn off when not collecting a sample from the sensor. With real time logging simply connect the DataMeter to your computer and run your logging software as normal. NB When using DataMeter on a power pack it will also charge and polarise the DO2 adapter and electrode, even if DataMeter is switched off. LogIT SL - Real time and remote logging If a CheckIT display is available plug it into the LogIT SL and turn it on by holding down the Green key (puts LogIT SL in meter mode, indicated by a flashing m in the bottom left corner of the display). Connect the sensor and charge/calibrate as per instructions. Before you commence remote data logging quickly turn LogIT SL off using then red button then turn it on by pressing the green button and the commence logging. With real time logging simply connect the LogIT SL to your computer and run your logging software as normal. If a CheckIT is not available connect LogIT SL to the computer in the normal way for logging and run the data logging software you use. Select the software s Test mode (if available) - this ensures that the LogIT SL remains on, as the computer displays a readings constantly taken from LogIT SL. If your software does not have a test facility you will need to log data, using bars or graph. CALIBRATION To calibrate only one adjustment is required for 100%. When first connected the sensor will over-range but after several minutes the reading will fall below 200%. It will continue to fall for about 10-20 minutes as the electrode polarises, however the reading will be substantially stable after a few minutes. Allow the sensor and the adapter to stabilise for some minutes before taking readings. Note that no harm will come to the adapter or electrode if it is left charging or polarising for an extended period of time. The recommended method is to calibrate the sensor within air which is saturated with water. This can be achieved by placing a sponge, which has been soaked in water, in the bottom of a beaker or container and then holding the sensor slightly above the sponge - do not touch the sponge (a retort stand is ideal to hold the sensor while adjustment is made). Allow the reading to settle as the temperature equalises through the sensor then adjust to read 100%. Adjustment can be made by inserting a small screwdriver through the hole in the adapter unit and turning until a reading of 100% is achieved - be careful not to over-turn the control. The unit is then calibrated. An alternative to the above method is to place the polarised electrode into a beaker of water that is being constantly stirred. Allow the reading to settle for several minutes as the temperature equalises through the sensor. Then carefully adjust the sensor control as above so that the reading is 100%. 3

See Using the Sensor section on how to view the readings and charge/polarise the sensor with specific LogIT data loggers. LOGGING During logging LogIT SL or DataMeter automatically powers up, takes a reading and then sleeps until the next sample - this also helps to top up the rechargeable battery. However after a prolonged time the rechargeable cell will fall below the critical charge level the polarisation voltage will decay. This means that as the LogIT wakes up the sensor will start to repolarise and the readings will be too high - this effect will increase over the logging period. The adapter is designed to last for at least 24 hours during logging provided it is fully charged at the start of the logging period. The precise time available for logging depends on the state of charge at the start and the logging rate etc. NB If DataMeter 1000 is connected to a mains pack, or it is in meter mode, the rechargeable cell in the adapter will be constantly charged. The same is true for a LogIT SL/LIVE and CheckIT in meter mode. IMPORTANT -CARE AND MAINTENANCE The electrolyte should be replenished regularly if in constant use or if the probe is only used occasionally it should be changed before calibration. Ensure that the cathode tip is not scratched or damaged as this will effect the electrode performance. Treat the membrane carefully as it is fragile. No grease, oil or organics should come into contact with the membrane. Avoid contact with the membrane to prevent punctures. The membrane does not need to be stored wet. If not used for long periods it is best stored disassembled and dry which will prolong its life considerably or it can be stored in 1m KCl solution. Over a period of use the silver anode is plated with silver chloride, black in colour, which needs cleaning off. This can be done with crocus paper ( very fine emery paper). Do not clean the cathode in this way as it must not be scratched. The probe and cable are water proof but the LogIT adapter is not so do not expose it to liquid or steam. Never disassemble the probe or adapter other than to change the membrane and clean the anode. Only use the special LogIT Dissolved Oxygen Probe with this adapter. FAULT FINDING Fault Possible Cause Remedy No Response Split membrane Replace membrane & electrolyte Sluggish response Electrolyte depletion Replace electrolyte Excessive output Stretched membrane Replace membrane & electrolyte High zero reading Air bubbles in electrolyte Replace electrolyte Should you have any difficulty please contact DCP technical support by telephone, fax, email (support@dcpmicro.com) or check the support pages on the DCP website (www.dcpmicro.com). 4

UPGRADING - Software, DataMeter 1000 and CheckIT As this sensor was newly developed (July 1998) you may require an upgrade to your software and/or CheckIT display and DataMeter 1000. LogIT brand products require Version i to support this product. If, when using the sensor for the first time, your software displays mv or UNKNOWN SENSOR, DataMeter 1000 displays??? or CheckIT displays mv then they require upgrading. Free Internet upgrades DataMeter and some software updates (including Insight and LogIT PC DOS) can be downloaded free from the DCP website at www.dcpmicro.com Upgrades by post LogIT brand products - please return the item(s) directly to DCP and mark your package for the Upgrade Department. Upgrades are free of charge but we can only upgrade 1 CheckIT per Dissolved Oxygen Probe purchased. If returning hardware please ensure it is sent by secure / registered post as we cannot accept any liability for non arrival of your equipment. These upgrades are only valid for UK customers - for overseas support and information please contact your supplier. Third party software (eg Insight, RM Investigate) have to be returned directly to the publishers, but please see our web site for some updates. SPECIFICATION Cathode: Gold Anode: Silver Range: 0-200% Saturation Temperature Range: 5 C to 45 C with auto. temp. compensation Temperature Coefficient: 1.5% / C Polarising Time: 20 minutes Accuracy: Nominal +/- 7% Dimensions: Custom Clarke cell 12mm OD x 105mm length Cap diameter 18mm OD, overall length 180mm Cable Length: 1 metre Designed & Manufactured in Great Britain DCP Microdevelopments Limited Edison House, Bow Street Great Ellingham, Norfolk NR17 1JB GREAT BRITAIN Tel: (01953) 457800 FAX: (01953) 457888 www.dcpmicro.com email: info@dcpmicro.com By David Hagan, David Palmer, Steve Gallagher 2000 DCP Microdevelopments Limited, Great Britain. 5 DP2407981