A little technical and safety...

Similar documents
Welcome to Flogas. Metered Estates. You would never know you were off the grid. Metered Estates Welcome Pack.indd 1 18/01/ :48

LPG TANK INFORMATION An energy company that puts

Welcome to Calor Information on your business gas supply

Module 6. Tightness Testing

Summary of the MRA LPG Codes of Practice

Using propane cylinders safely

GAS FRYER Instruction Manual Model #5099NS

Bottled Gas. Using LPG safely. for the way you want to live

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

WARNING: FOR OUTDOOR USE ONLY

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

Types 749B and R130 Changeover Manifolds

User Manual for the Mars Calibration Bench

Method Statement: Testing Dry Riser System

User Information Sheet 028

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures

INSTALLATION OPERATION MAINTENANCE

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Entertainer Portable BBQ

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Emergency Situation Assessment

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

VAPOMATIC ANESTHETIC VAPORIZER

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised

Regulator from 1800 B series

ACS.CoNGLP1 SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC NATURAL GAS TO LPG GENERIC

MAINTENANCE AND SAFETY OF CNG REFUELLING STATIONS

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Management Plan for Compressed Gas

for the of and the EM55-1

HOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)

Cylinder Exchange Training Manual

Budget Range Operators Handbook

Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

Standard Gas Countertop Griddle

MANUAL BE SERIES Test Benches

Safe Work Instructions For Oxygen Acetylene Equipment

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

Owner s Manual for Assembly, Operating & Maintenance of

Warning: NEVER ALTER TEST EQUIPMENT

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

User Information Sheet 015

DSEAR- Storage, Use and handling of gas cylinders guidance.

Model 420-HY Pressure Regulating Hydrant Valve

Important: Retain these instructions for future use.

R E D I C O N T R O L S

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

Facilities and Estates. Natural Gas: Standard Operating Procedure. Document Control Summary. Contents

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

OPERATING INSTRUCTIONS AND OWNER S MANUAL READ AND FOLLOW ALL INSTRUCTIONS

1200B2 Series Service Regulators. Instruction Manual

System Pressure Manager Standard & System Pressure Manager Plus

Gas Countertop Hot Plates

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

Draft. Not yet Approved

General Precautions for handling compressed gases

Transferring and Storage

CITY OF THIBODAUX GAS AND WATER DISTRIBUTION DIVISION

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

INSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS

CITY OF THIBODAUX GAS AND WATER DISTRIBUTION DIVISION

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

PRESSURISED PAINT CONTAINER

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

GAS BBQ 4 burner. instructions for. model no: BBQ10

Working Environment Safety Assessment

Safety instructions and operating manual

Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

Owner's Manual and Instructions

1800C and 1800C-HC Series Service Regulators

R600 and HSRL Series Instruction Manual

Code AWC20HP Air Compressor

New Hampshire Public Utilities Commission CFR 49 Part 192 Regulations. MINIMUM Pipeline Safety Regulations

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

R122H, R222, R232A, and R232E Series Instruction Manual

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Peninsula Dental Social Enterprise (PDSE)

Fire Safety Hot Work Permit Policy/ Procedures

Residential and Small Commercial

September 2018 Pressure Test

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

J Air and Water Kit Instructions Part# 02584

VERTICAL AIR COMPRESSORS

Installation, commissioning and servicing instructions

OPERATION MANUAL NTF-15

Bermad Pressure Reducing. Model: 42T

STANDARD OPERATING PROCEDURE

Installation, commissioning and servicing instructions

OPERATION MANUAL NTF-60 Plus

OCTOBER 2017 ISSUE Page 1 of 7

Tri-Tech Medical Inc.

CODE OF GUIDANCE. For the Storage of Full & Empty LPG Cylinders and Cartridges. Page 1

Liquid Oxygen- Helios & Helios Marathon A Guide for Patients in the Home

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

Bermad Model:

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Overview EUSSAM12. Carry out tightness testing and direct purging of gas installations

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Transcription:

A little technical and safety...

Please familiarise yourself with the contents of this booklet as it references the safety of your tank installation and safe supply of LPG. Please also keep to hand a note of our emergency number should you need it which is noted on page 4. How to read your tank gauge 40% When your tank reaches 40%, On-Call customers should place an order. Contents How to read your tank gauge 03 In case of a leak 04 Turning off your gas supply 05 In case of a fire 06 Access and changes to the site 07 Tank and equipment responsibilities 07 Your Flogas Installation 08 Tank safety equipment 10 20% The red indicates that you still have nearly ¼ tank of gas. Top-Up customers who reach 20% shouldn t worry, but should let us know by calling us on: 0800 574 574. 85% No LPG Tank can be filled beyond 85%. The extra space is needed for the gas to expand. Your contents gauge can be found to the side of the hood or under the inspection hatch of an underground tank. 02 03

In case of a leak In the unlikely event of a leak from your tank, the following action should be taken: 1 Extinguish all possible sources of ignition within 7.5 meters of the leak if you suspect the leak to be outside. If you suspect the leak to be indoors extinguish any sources of ignition within the property. 2 Do not operate any electrical equipment. This includes switches. Turning off your gas supply In certain situations you may require turning off your gas supply. For your own safety as well as others, you should familiarise yourself with the operation of the emergency control valve illustrated below. This is normally located outside the property at the point of entry. TO TURN OFF YOUR GAS SUPPLY PLEASE FOLLOW THE STEPS ELOW: 1 Turn off all appliances taps and pilot lights. 2 Turn the emergency control valve to the off position (when the valves handle points across the pipe). 3 Do not smoke. 4 Turn off all gas appliances, where safe to do so. 5 6 Increase ventilation if the leak is indoors by opening windows and doors. A leak in LPG piping can be stopped by closing the emergency control valve on the tank. Emergency Control Valve in the on position Emergency Control Valve in the off position IN ORDER TO ISOLATE THE GAS SUPPLY FROM THE TANK, FOLLOW THE STEPS DETAILED ELOW: 1 Open the hood or inspection hatch on the tank. 2 Identify the service isolation valve illustrated below. 3 Close the valve by turning clockwise. 7 Call Flogas 24 hour emergency number immediately on 0345 720 0100. Your gas supply should be isolated at the property. 04 05

In case of a fire If there is a fire at the property irrespective of the cause, the following action should be taken: 1 2 Dial 999 requesting the fire brigade immediately and tell them that a Flogas LPG (propane) vessel is located on the premises. Turn off the supply of gas on the tank if possible, without taking any risk to your own safety. 3 Remove everyone from the area to a safe distance. 4 Call Flogas 24 hour emergency number immediately on 0345 720 0100. Access & changes to the site Flogas require access at all times to be able to inspect your tank. We ask that you please notify us if any access or structural changes are made to the site that may impede deliveries of gas, servicing or the general safety of your tank. Tank & equipment responsibilities The below diagram highlights in purple the responsibilities of Flogas, while shaded in blue is the area our customers are responsible for. Flogas are responsible for the LPG installation up to (but not including) the first stage regulator. Customers are responsible for the pipework, first and second stage regulator and appliances. Service 1st Stage Regulator Pressure Relief Valve 2nd Stage Regulator with UPSO/OPSO Emergency Control Valve 06 07

Your Flogas installation CARING FOR YOUR INSTALLATION Caring for your installation is essential; please be aware that if you do not look after the installation properly you may be faced with potential liability (civil and /or criminal). Failure to comply with the points listed below may result in you as the customer being financially responsible for any remedial work. Please familiarise yourself with your responsibilities below: You must not interfere or modify the installation or any part of it. You must keep the area within a radius of 3 meters of the tank clear of weeds, rubbish and/or combustible materials and take such other security precautions as may be required and notified to you by us or by a fire prevention officer or the local authority from time to time. (Please note that chlorate based weed killers should NOT be used, as they can be a fire hazard.) You must not erect or allow any other person to erect any building and/or structure whether of a permanent or temporary nature (including outbuildings, sheds, garages, conservatories, greenhouses, walls or rockeries) nor allow any deep rooted shrubs, trees or hedges to grow within 3 meters of the tank. Where the tank is stored below ground you must not permit any hard standing to be constructed over the place where the tank is buried. If your tank is underground, please take care when mowing your lawn not to catch the inspection hatch. You must contact a Flogas representative before erecting any overhead cables. You must not detach, alter, cover up, remove or otherwise interfere with any identification, instructions, warnings, trade marks or any other signs on the installation. You must not allow anyone to smoke or have any source of ignition within three meters of the tank. You must not paint the installation as this may affect the amount of heat absorbed by the sun. Please make yourself aware of the route the pipework takes and avoid putting anything in the ground that might damage it. If you are unsure please contact us for advice. You are responsible for all costs relating to works required following the failure or subsidence of the tank base or anchor slab. For underground installations changes should not be made that will direct surface water towards, or prevent water draining from, the tank area. Surface water drainage should be maintained to ensure water does not build up in the valve chamber. The customer will be responsible for all costs relating to the failure of the gas supply and the replacement of any water damaged equipment (this includes all costs relating to Flogas not being able to refill the tank whilst the valve chamber is flooded with water). PROTECTING AND INSURING THE INSTALLATION Please protect the installation from theft, damage and/or other risks of loss and/or harm including without limitation, vandalism and damage caused by fire. Please remember that you are responsible for the safekeeping of the installation. It is a requirement that the tank and fittings are adequately insured against any damage or loss which may occur to them including without limitation risks such as fire, theft, accidental damage and personal injury. As a valued contracted customer, Flogas will make sure that all necessary insurance is in place free of charge. We shall also carry out all routine maintenance and all repairs which are required due to the fair wear and tear and/or any inherent defects or faults in the tank and fittings and shall comply with any laws, regulations and/or orders for the time being in force. In order that our records are kept up to date and allow us to ensure the safe management of your account, we would ask you to contact Flogas when the term of your current Agreement is coming to an end. 08 09

Tank safety equipment There are numerous items of safety equipment included in and on your tank to make it as safe as possible. Included amongst these is the under pressure shut off/ over pressure shut off device (UPSO/ OPSO). This safety device is designed to shut down the supply of gas to your property in the event of a problem. Please familiarise yourself with the following information. OPSO This device will operate when there is an increase in gas pressure. If the OPSO has operated, Flogas should be contacted. UPSO This device will operate when there is a fall in gas pressure. This can occur if you isolate the supply at the tank, or, if the tank becomes empty. Unlike with the OPSO, resetting this device can be done safely and easily by you. There are two possible types of system, please check to see which one is relevant to your tank and then follow the related directions. SYSTEM A: Service Pressure Relief Valve 1st Stage Regulator 2nd Stage Regulator with UPSO/OPSO A Emergency Control Valve If the indicator stem in the window at the top is showing red, then it is closed and needs to be reset: 1 To do this, ensure that the gas is turned on at the tank. 2 Ensure that all gas appliances are turned off. 3 Ensure your emergency control valve A is turned to the off position. (See page 5) 4 Remove cap by unscrewing to expose the indicator/reset stem. 5 Pull stem (please do not push) and hold for a few seconds to allow the system to recharge. The stem should stay in this position when released. Gas Inlet If the UPSO has operated the indicator stem will appear red in the cap window OPSO REG/RELIEF/UPSO SECOND STAGE REGULATOR Gas Outlet 6 Replace the cap. 7 Open the emergency control valve slowly. (See page 5) 8 Re-light any permanent pilots and check that all appliances will light to confirm that the gas supply has been re-established. 9 If the gas supply does not re-establish itself then check that all the appliances are turned off and repeat the above procedure. 10 If after two attempts the gas supply has not been re-established or you have any doubts or difficulties, please contact Flogas for further advice. SYSTEM : Service Pressure Relief Valve When the device has operated, the following procedure should be followed in order to reset it: 1 Ensure that the gas is turned on at the tank. 2 Ensure that all gas appliances are turned off. 3 Ensure your emergency control valve A 4 Remove cap by unscrewing to expose the reset stem. is turned to the off position. (See page 5) 5 Pull stem (please do not push) and hold for a few seconds to allow the system to recharge. The stem should stay in this position when released. 6 Replace the cap. 1st Stage Regulator A Emergency Control Valve 2nd Stage + USPO 7 Open the emergency control valve slowly. (See page 5) 8 Re-light any permanent pilots and check that all appliances will light to confirm that the gas supply has been re-established. 9 If the gas supply does not re-establish itself then check that all the appliances are turned off and repeat the above procedure. 10 If after two attempts the gas supply has not been re-established or you have any doubts or difficulties, please contact Flogas for further advice. Please note that the UPSO device can sometimes be located on the tank itself. Red or lack cover cap 10 11

Experts in energy So you don t have to be Contact us: 0800 574 574 or visit our website www.flogas.co.uk Connect with us on Rayns Way, Watermead usiness Park, Syston, Leicester, LE7 1PF